Supply Of Iron And Steel Materials, Fabrication & Erection Of Structure, Providing Earth Mat & Earth Electrode, Erection Of Equipments, Cable Laying And Termination Etc For Enhancement Of 400 / 110Kv Ict Capacity From 2X200 Mva To 3X200 Mva At Alamathy 400 / 230-110Kv Ss-Supply, Fabrication And Sand Blastingwith Zinc Painting Of Ms Channel Various Size & Ms Angle Various Size , Including Cost Of Transport & Other Incidental Charges. 2 Supply Of Ms Flat Varioussize For Earthmat & Earth Raisers ( 75 X12mm, 65 X 10Mm, 50 X 8Mm & Etc. ) Including Cost Of Transport & Other Incidental Charges. 3 Supply Of Ms Rod 40Mm Round ( 10M / 6M Length ) For Earth Electrode, Including Cost Of Transport & Other Insitental Charges. 4 Labourcharges For Erection Of Structure - Light Section ( Sectionalweight Below 14Kg / Mtr ) 5 Labour For Erection With Own Crane Arrangement And Connecting Link Rod, Sf6 Gas Filling And Other Consumables And As Directed By The Field Engineer - Sf6 Circuit Breaker 400 Kv 6 Labour For Erection With Own Crane Arrangement And Connecting Link Rod, Sf6 Gas Filling And Other Consumables And As Directed By The Field Engineer- Sf6 Circuit Breaker 110 Kv 7 Labour For Erection With Own Crane Arrangement Including Providing Holes Wherever Required, Fixing Junction Box & Other Consumables As Directed By The Field Engineer - 400Kv Ct 8 Labour For Erection With Own Crane Arrangement Including Providing Holes Wherever Required, Fixing Junction Box & Other Consumables As Directed By The Field Engineer - 110Kv Ct 9 Labour For Erection Of Ab Switches, Including Cost Of Lubricant, Consumable And Wiring ( If Necessary ) Allignment, Checking Of Operation By Both Manual And Electrical ( If Necessary ) And As Directed By The Field Engineer - Withdouble Earth Motor Operated 400 Kv 10 Labour For Erection Of Ab Switches, Including Cost Of Lubricant, Consumable And Wiring ( If Necessary ) Allignment, Checking Of Operation By Both Manual And Electrical ( If Necessary ) And As Directed By The Field Engineer - With Singleearth Motor Operated 400 Kv 11 Labour For Erection Of Ab Switches, Including Cost Of Lubricant, Consumable And Wiring ( If Necessary ) Allignment, Checking Of Operation By Both Manual And Electrical ( If Necessary ) And As Directed By The Field Engineer - Withoutearth Motor Operated 110 Kv 12 Labour For Erection Of Las Including Fabrication Of Base If Required - Station Type 400 Kv 13 Labour For Erection Of Las Including Fabrication Of Base If Required - Station Type 110 Kv 14 Erection Of 400 Kv Strung Bus Using Quad Moose Conductorand Erection Of 2 X 25 Nos.Anti Fog Disc Including Jumbers Providing Form Existing Bus To New Erection Bus As Directed By Field Engineer ( 1Span X 12Run ) With Supply Of Sutable Spacer Clamp, Fixing Bolted Type Double Tension Fitting With Corona Ring, Arcing Horns ( Adjustable Plate & Spring On One Side & Fixed On Another Side ) , Yoke Plate ( Top - Adjustable, Bottom - Fixed ) , Double Anchring With Fittings 15 Erection Of 400 Kv Strung Bus Using Twin Moose Conductor And Erection Of 2X 25Nos Anti Fog Disc As Directed By Field Engineer ( 1Span X6run ) With Supplyofsutable Spacer Clamp, Fixing Bolted Type Double Tension Fitting With Corona Ring, Arcing Horns, ( Adjustable Plate & Spring On One Side & Fixed On Another Side ) , Yoke Plate ( Top - Adjustable, Bottom - Fixed ) , Double Anchring With Fittings 16 Erection Of 400Kv Strung Bus Linking Arrangement Using Twin Moose Condutor And Erection Of 1 X 25 Nos. Anti Fog Disc Insulators With Supply Ofsutable Spacer Clamp, Bolted Type Suspension Fitting With Double Anchoring Points, Corona Ring, ( Adjustable Plate & Spring On One End & Fixed On Another End ) , Yoke Plate ( Top - Adjustable, Bottom - Fixed ) , With Fittings & Accessories Suitable For Twin Moose And 17 Erection Of 110 Kv Strung Bus Using Quad Moose Conductor And Erection Of 2 X 25 Nos.Anti Fog Discincluding Jumbers Providing Form Existing Bus To New Erection Bus ( 1Span X 12Run ) With Supply Offixing Bolted Type Double Tension Fitting With Corona Ring, ( Adjustable Plate & Spring On One Side & Fixed On Another Side ) , Yoke Plate ( Top - Adjustable, Bottom - Fixed ) , Double Anchring With Fittings 18 Erection Of 110 Kv Strung Bus Using Twin Moose Conductor And Erection Of 2 X 10 Nosanti Fog Disc Insulatorsas Directed By Field Engineer ( 1Span X 6Run ) With Supply Of Sutable Spacer Clamps, Fixing Bolted Type Double Tension Fitting With Corona Ring, Arcing Horns, ( Adjustable Plate & Spring On One Side & Fixed On Another Side ) , Yoke Plate ( Top - Adjustable, Bottom - Fixed ) , Double Anchring With Fittings 19 Erection Of 110 Kv Strung Bus Linking Arrangement Using Twin Moose Condutor And 1 X 10 Nos. And Erection Of Anti Fog Disc Insulators With Supply Ofsutable Spacer Clamp, Bolted Type Suspension Fitting With Corona Ring, ( Adjustable Plate & Spring On One End & Fixed On Another End ) , Yoke Plate ( Top - Adjustable, Bottom - Fixed ) , With Fittings & Accessories Suitable For Twin Moose 20 Supply Of Seating Block For 3 Al. Bus Confirm To Latest Is. 21 Supply Of T - Clamp For Double Moose To Single Moose ( 450 Mm Spacing ) Confirm To Latest Is. 22 T - Clamp For Double Moose To Single Moose ( 225 Mm Spacing ) 23 Supply Of T- Clamp For Single Moose To Single Moose Confirm To Latest Is. 24 Supply Of T - Clamp For Double Moose To 4 Alu. Bus Confirm To Latest Is. 25 Supply Of T - Clamp For Double Moose To 3 Alu. Bus Confirm To Latest Is. 26 Supply Of Switch End Clamp For Twin Moose Confirm To Latest Is. 27 Supply Of Seating Block For 4 Al. Bus Confirm To Latest Is. 28 Supply Of 4 Bus To Bus Jointing Clamp Confirm To Latest Is. 29 Supply Of Corona Bell For 4 Alu. Bus For 400 Kv Confirm To Latest Is. 30 Supply Of Corona Bell For 3 Alu. Bus For 110 Kv Confirm To Latest Is. 31 Supply Of 400 Kv Spacer For Quad Moose Rigid Type ( 450Mm Spacing ) Confirm To Latest Is. 32 Supply Of 400 Kv Spacer For Twin Moose Rigid Type ( 450Mm Spacing ) Confirm To Latest Is. 33 Supply Of 110 Kv Spacer For Quad Moose Rigid Type ( 225 Mm Spacing ) Confirm To Latest Is. 34 Supply Of 110 Kv Spacer For Twin Moose Rigid Type ( 225Mm Spacing ) Confirm To Latest Is. 35 Supply Of Bay Marshalling Box- Ac Junction Box ( Frp ) 36 Supply Of Bay Marshalling Box- Dc Interlock Box ( Frp ) 37 Erection Of 400 Kv, 4 Aluminium Bus Withbend As Per Field Condition 38 Erection Of 110 Kv, 3 Aluminium Bus With Bend As Per Field Condition 39 Provoding Joints For Al. Bus Bar 4 Where Ever Necessary As Per Field Condition By Suitable Al. Welding 40 Provision Ofjumpers & Droppers With Twin Moose ( On Normal Condition ) 41 Provision Of 110 Kv Jumpers & Droppers With Twin Moose ( On Lc Condition ) 42 Erection Of Under Hang Or Suspension Arrangement For 400 Kv With 25 Disc Insulators, Corona Ring With Fittings & Accessories 43 Erection Of Support Insulators For 400 Kv With Corona Ring 44 Erection Of Under Hang Or Suspension Arrangement For 110 Kv With 10 Disc Insulators, Corona Ring With Fittings & Accessories 45 Erection Of Support Insulators For 110 Kv 46 Labour, Machineries, Consumablefor Fabrication And Erection Of Earth Electrode As Directed By The Field Engineer 47 Labour Machineries, Consumables For Fabrication And Erection Of Earthmat& Earth Raisers. 48 Providing 140 / 150 Mm Dia Bore Including Labour Lead Lift Etc., In All Types Of Soils And Erection Of Earth Electrodes, Supply And Providing Of A4 Grade Bentonite Powder With 5 % Common Salt Mixed With Available Site Clay Soil 5 Kg / Mtr Depth In Earth Bore And Pouring Water And Tightening Of Earth Bore Up To Satisfactory Earth. 49 Labour For Erection Of Panel / Bmb - Simplex Indoor / Out Door 50 Labour For Laying And Termination Of Cable In Duct / Trunch Including The Cost Ofgland, Lugs And Alu.Tag, For Identification. Upto8core 51 Labour For Laying And Termination Of Cable In Duct / Trunch Including The Cost Ofgland, Lugs And Alu.Tag, For Identification. Above 8Core 52 Labour For Excavation & Refilling Of Trunch Of Avg. Width Of 0.3M & Avg Depth Of 0.8M For Earth Mat And Avg.Depth Of 0.4M For Laying Of Cable Below Fixed Yard Level & Any Of Size As Required. 53 Labour For Erection Of Led Light Fitting With Fixture And Fuse Box Including Wiring And Testing For Burning Condition Including The Cost Of 15 Amps 2Way Strip Connector And Other Consumables. 54 Labour Charges For Painting Earth Raisers By Green Enamal Painting And Wherever Required Including Cost Of Paint ( Dulex, Asian, Berger Prefered ) And Other Consumables As Directed By The Field Engineer 55 Hire Charges For Crane Provided For Any Erection Or Loading, Unloading Or Shifting Of Equipments Done By Department Or Contractor 56 Supply And Provision Of M8, M9, M 10, M 12, M 16Full Threaded Gi Bolt Nuts And Washers Of Various Sizes For Erection Of Insulators Or Any Other Purposes 57 Manufacturing & Supply Of Yard Light Box Of Size 200 W X 175 H X 150 D Mm Out Of 18 Swg ( 1.2Mm ) M.S.Sheet With Cable Entry Holes, Fixing Arrangements For Fuse Units And Mounting Clamps As Directed By The Field Engineer Including Cost Of All Materials. 58 Supply And Erection Of Led Lamp 72W Fitting With Fixture And Fuse Box Including Wiring And Testing For Burning Condition Including Cost Of 15 Amps 2Way Strip Connector And Other Consumables 59 Supply & Fixing Of Isi Mark Bakelite Hrc / Rewireable Fuse Holder In Panels / Boxes For Ac / Dc / Pt Circuits Wherever Required As Directed By The Field Engineer - 16Amps 60 Supply & Fixing Of Isi Mark Bakelite Hrc / Rewireable Fuse Holder In Panels / Boxes For Ac / Dc / Pt Circuits Wherever Required As Directed By The Field Engineer - 32Amps 61 Supply & Fixing Of Isi Mark Bakelite Hrc / Rewireable Fuse Holder In Panels / Boxes For Ac / Dc / Pt Circuits Wherever Required As Directed By The Field Engineer - 63Amps 62 Supply & Fixing Ofisi Mark Hrcfuse Without Holder Of Reputed Make In Panels / Boxes For Ac / Dc / Pt Circuits Wherever Required As Directed By The Field Engineer - 2 / 5 / 10Amps 63 Supply & Fixing Ofisi Mark Hrcfuse Without Holder Of Reputed Make In Panels / Boxes For Ac / Dc / Pt Circuits Wherever Required As Directed By The Field Engineer - 32Amps 64 Supply & Fixing Ofisi Mark Hrcfuse Without Holder Of Reputed Make In Panels / Boxes For Ac / Dc / Pt Circuits Wherever Required As Directed By The Field Engineer - 63Amps 65 Supply And Fixing Of Ac 3 Phase 4 Pole 415 V Isi Mark Changeover Switch Of Reputed Make As Required And As Directed By The Field Engineer - 63 Amps 66 Supply And Fixing Of Ac 3 Phase 4 Pole 415 V Isi Mark Changeover Switch Of Reputed Make As Required And As Directed By The Field Engineer - 100 Amps 67 Supply And Glanding Of Isi Markcable Glands Of Suitable Size Of Reputed Make Including Removing Insulation Of Cable And Providing Suitable Holes As Directed By The Field Engineer - 19Mm 68 Supply And Glanding Of Isi Markcable Glands Of Suitable Size Of Reputed Make Including Removing Insulation Of Cable And Providing Suitable Holes As Directed By The Field Engineer - 25Mm 69 Supply And Glanding Of Isi Markcable Glands Of Suitable Size Of Reputed Make Including Removing Insulation Of Cable And Providing Suitable Holes As Directed By The Field Engineer - 28Mm 70 Supply And Glanding Of Isi Markcable Glands Of Suitable Size Of Reputed Make Including Removing Insulation Of Cable And Providing Suitable Holes As Directed By The Field Engineer - 32Mm 71 Supply And Glanding Of Isi Markcable Glands Of Suitable Size Of Reputed Make Including Removing Insulation Of Cable And Providing Suitable Holes As Directed By The Field Engineer - 45Mm 72 Supply And Termination Of Cable Core End Including Cost Ofcable Socket , Lug, Ferrules, Strap Etc, As Per Cable Schedule And As Directed By The Field Engineer . 73 Fabrication, Supplyand Fixing Of Earth Electrode Identification Board Of Size300 X 250Mm Out Of 14 Swg ( 2Mm ) M.S.Sheet And 12Mm Dia Msround As Per Drawing Including Cost Of All Materials 74 Supply Of Godrej Make 6 Lever Navtal Lock With Triplicate Keys For Ab Switches And For Any Other Purpose Including The Cost Of Ring & Key Token 75 Supply And Providing Of 600Mm Mean Dia, 300Mm Height, 36Mm Thick Cement Collar For Identification Of Earth Electrode Location Includung 1 Primer Ans 2 Coat Of Colour Wash 76 Supplyandfixingof Flexible Copper Tape / Rope Forinterlinkingpanel Earthing And For Any Other Purpose On Any Sizes Including Cost Of Copper Lugs At Both Ends As Per The Direction Of Field Engineer. 77 Supply & Fixing Of Isi Make Dc Mcb In Panels / Boxes Of Reputed Make As Directed By The Field Engineer - 1Pole 16Amps 78 Supply & Fixing Of Isi Make Dc Mcb In Panels / Boxes Of Reputed Make As Directed By The Field Engineer - 2Pole 16Amps 79 Supply & Fixing Of Isi Make Dc Mcb In Panels / Boxes Of Reputed Make As Directed By The Field Engineer - 2Pole 32Amps 80 8 Metre Length Single Bracket Pole With Base Plate ( 250 X 250 X 6Mm ) 114.30Mm Od X 5.40Mm Thick X 4500Mm Length, 88.90Mm Od X 4.85Mm Thick X 1750Mm Length, 76.10Mm Od X 3.25Mm Thick X 1750Mm Length 81 8 Metre Length Double Bracket Pole With Base Plate ( 250 X 250 X 6Mm ) 114.30Mm Od X 5.40Mm Thick X 4500Mm Length, 88.90Mm Od X 4.85Mm Thick X 1750Mm Length, 76.10Mm Od X 3.25Mm Thick X 1750Mm Length 82 Gst For Bidders Within Tamilnadu 83 Sgst 84 Cgst 85 Gst For Bidders Outside Tamilnadu ( Igst )