| 1 | Cabling Related Works -UG XLPE Cable size 11kV 3C x 300 Sq.mm |
| 2 | Supply of 11 kV,XLPE insulated Aluminium Conductor, Armoured cable as per enclosed specification 3 core 300 sq. mm. |
| 3 | Straight Joint: HT push on/heat shrink type straight joint preferablyfor 11 kV XLPE 3Cx300 mm 2 Aluminium Conductor Armoured cable asspecified with connection of leads including cutting,stripping of cable, insulations,providing compression type terminals,crimping of lugs with suitable crimping tool.as per technical specification, approved drawings and scope of work. |
| 4 | Outdoor application: HT push on/heat shrink type end terminationpreferablyfor at switchgear end boxes, transformer( PAD/Pole mounted) for11 kV XLPE 3Cx300 mm 2 Aluminium Conductor Armoured cable as specified with connection of leads including cutting,stripping of cable, insulations,providing compression type terminals,crimping of lugs with suitable crimping tool, as per technical specification,approved drawings and scope of work. |
| 5 | Indoor application: HT push on/heat shrink type end terminationpreferablyfor at switchgear end boxes, transformer( PAD/Pole mounted) for11 kV XLPE 3Cx300 mm 2 Aluminium Conductor Armoured cable as specified with connection of leads including cutting,stripping of cable, insulations,providing compression type terminals,crimping of lugs with suitable crimping tool, as per technical specification,approved drawings and scope of work. |
| 6 | Cabling Related Works -UG XLPE Cable size 11kV 3C x 150 Sq.mm |
| 7 | Supply of 11 kV,XLPE insulated Aluminium Conductor, Armoured cable as per enclosed specification 3 core 150 sq. mm. |
| 8 | Outdoor application: HT push on/heat shrink type end terminationpreferablyfor at switchgear end boxes, transformer( PAD/Pole mounted) for11 kV XLPE 3Cx150 mm 2 Aluminium Conductor Armoured cable as specified with connection of leads including cutting,stripping of cable, insulations,providing compression type terminals,crimping of lugs with suitable crimping tool, as per technical specification,approved drawings and scope of work. |
| 9 | Indoor application: HT push on/heat shrink type end terminationpreferablyfor at switchgear end boxes, transformer( PAD/Pole mounted) for11 kV XLPE 3Cx150 mm 2 Aluminium Conductor Armoured cable as specified with connection of leads including cutting,stripping of cable, insulations,providing compression type terminals,crimping of lugs with suitable crimping tool, as per technical specification,approved drawings and scope of work. |
| 10 | 11kV, 3 Core 120+ 1 Core 95 sq.mm ( Insulated messenger) AB Cable |
| 11 | Supply of 11 kV, 3 Core 120 sq.mm + 1Core 95 sq.mm (Insulated messenger) ABC with all necessary accessories ( Heat shrinkable sleeves, Anchor clamp or dead end clamp for HT ABC, Suspension clamp suitable for HT ABC, Stainless steel strap, stainless steel buckles, cable ties UV plastic heavy duty around 250mm long, insulator piercing connector, suitable size bolt & nuts, materials required for earthing at required intervals etc. and excluding termination end kit ) as per technical specification and scope of works. |
| 12 | Supply of 11 kV, 3 Core 120 sq.mm ABC Termination end kit for 3 phases ( incl. all accessories) as per technical specification and scope of works. |
| 13 | 9 Meter GI Tubular Poles |
| 14 | A Pole (11 meter)Steel Galvanised |
| 15 | Supply of galvanised Stay Set with 300x300x10stay anchor plates , 50x8mm stay clamp, stay guy insulator, nut bolts, 2 Nos turn buckle\"s, 1.8 m long, 20 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required by providing 0.2 cum cement concrete as per approved drawings, technical specification and scope of work. |
| 16 | 33/11 KV Substation Works- Common for fully outdoor substation |
| 17 | 33/11 kV, 8.0 MVA, 3 ph, 50 Hz, ONAN, Cu Wound, Outdoor Conventional type Power Transformer along with transformer oil, Buchholtz relay, breather, OTI & WTI, Marshalling Box, Conservator tank, oil level indicator, valves, 2 sets of 50x8 mm GS Neutral Earthing strips {(with braided conductor on bushing end), isolating link,isolation with insulators}, Vent explosion plug, control wiring between sensing equipment and marshalling box, cable supporting tray on the body of transformer, transformer wheels, LV/HV bushing, OFF Load tap changer etc as required as per technical specifications, approved drawings and scope of the work. |
| 18 | Gantry structures made of H-Beam 152x152 mm 37.1 kg 8 meter long, double MS Channel 100x50mm for bus bar supports (Beam), 65x65x6mm angle for cross arms/supporting structures and 50x8mm flats for clamps along with hardware items duly painted etc. as per technical specifications, approved drawings and scope of works. (OR) |
| 19 | Gantry structures made of Lattice structures of equal angles sections, flat as per approved drawings. State practices are to be adopted in the design. All structural steel members and bolts shall be galvanized after fabrication as per IS:4759 and zinc coating shall not be less than 610gm/sq. meter for all structural steel members. All L45x45x5 will have 23 mm back mark. All L50x50x6 will have 28mm back mark. 3.5mm spring washers are to be used under each nut, structural steel shall conform to IS 2026. All weld shall be 6mm filled weld unless specified otherwise. All nuts and bolts shall be of property class 5.6 of IS 1367. Plain washers shall be as per IS 2016 & spring washers shall be IS: 3063 as per technical specifications, approved drawings and scope of works. . |
| 20 | 36kV, 1250A, 25kA for 3 seconds, 3-ph,Outdoor typeVacuum Circuit breakeralong with100/1-1-1 Amps, Cl: 0.2S -5P20 / PX , 3 Nos outdoor type Current Transformers, Voltage Transformers with junction box (1 no junction box for 3 no of 1-phase CTs & VTs), NCT\"s, Jumpers, earthing, supporting structures, bi-metallic clamps,permanent maintenance platform, marshalling box etc required as per technical specifications, scope of works and approved drawings |
| 21 | 33kV, Indoor, Control & Relay panel along with E/F & O/C relayswith SCADA compatability, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc as per approved drawings, specifications and scope of works controlling |
| 22 | Power transformer 33 kV VCBwith Static Tri-Vector Energy Meter |
| 23 | 36kV, 630A, 25kA for 3 seconds, 3-ph double break center rotating type (DBCR), Gang Operated,isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications, scope of works and approved drawings |
| 24 | 9kV, 10kA, 1-ph Station Class Lightening Arrester with mounting platform, jumpering from bus bar, earthing connection using 50x6mm GS flat, hardware, etc as required as per technical specifications, approved drawings and scope of the works. |
| 25 | SCADA Compatible - 11kV, 5Panel Indoor set with 1 Incomer ( With CTs for Special Protection)Indoor type 12 kV, 1250 A (Incomer) and 630A (Outgoing), 25kA for 3 seconds, 3-ph,Vacuum Circuit breaker (VCB)along with 12 kV, 1-Phase, 400/5-5-5A,300/5-5-5A Cl: 0.2S -5P20 / PX Current Transformers & Voltage Transformers and required complete accessories including indoor cables termination kit ( incomer only) as per technical specifications, approved drawings and scope of the works. |
| 26 | SCADA Compatible - 11kV, 10 PanelsIndoor set with 2 Incomers, 2 Bus Couplers ( With CTs for Special Protection)Indoor type 12 kV, 1250 A (Incomer & Bus Coupler) and 630A (Outgoing), 25kA for 3 seconds, 3-ph,Vacuum Circuit breaker (VCB)along with 12 kV, 1-Phase,400/5-5-5A,300/5-5-5A Cl: 0.2S -5P20 / PX Current Transformers & Voltage Transformers and required complete accessories including indoor cables termination kits as per technical specifications, approved drawings and scope of the works. |
| 27 | ACSR Kundah |
| 28 | ACSR Wolf |
| 29 | Earth Wire 7/ 3.15 mm dia |
| 30 | 33kV Disc Insulator |
| 31 | Hardware fittings |
| 32 | Clamp Various Type |
| 33 | 11kV LA Station Class |
| 34 | 12mtr. A Pole |
| 35 | 3mtr. Channel with clamp |
| 36 | Bolt and nuts- Various sizes |
| 37 | Stay set complete |
| 38 | 3Cx300 sqmm UG Cable |
| 39 | 1Cx500 sqmm UG Cable |
| 40 | 19 Core 2.5 sqmm armored, stranded copper conductor, PVC insulated and PVC sheathed cable |
| 41 | 4 Core 2.5 sqmm armored, stranded copper conductor, PVC insulated and PVC sheathed cable |
| 42 | 4 Core 4 sqmm armored, stranded copper conductor, PVC insulated and PVC sheathed cable |
| 43 | 2 Core 4 sqmm armored, stranded copper conductor, PVC insulated and PVC sheathed cable |
| 44 | 12 Core 2.5 sqmm armored, stranded copper conductor, PVC insulated and PVC sheathed cable |
| 45 | 12 Core 4 sqmm armored, stranded copper conductor, PVC insulated and PVC sheathed cable |
| 46 | GI Strip 50 x6 mm |
| 47 | MS Rod 25mm |
| 48 | Miscellaneous |
| 49 | LT AB Cables |
| 50 | Supply of 3x95+1x70+1x16 (Insulated messenger) ABC with all necessary accessories ( Heat shrinkable sleeves, Anchor clamp or dead end clamp for LT ABC, Suspension clamp suitable for LT ABC, Stainless steel strap, stainless steel buckles, cable ties UV plastic heavy duty, insulator piercing connector, suitable size bolt & nuts, materials required for earthing at required intervals etc. ) as per technical specification and scope of works. |
| 51 | Pole PSC 9 Meters as per technical specification and scope of works. |
| 52 | Supply of galvanised Stay Set with 200x200x8 mm stay anchor plates , 50x8mm stay clamp, stay guy insulator, nut bolts, 2 Nos turn buckle\"s, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required by providing 0.2 cum cement concrete as per approved drawings, technical specification and scope of work. |
| 53 | Miscellaneous |
| 54 | LT UG Cables as per technical specification, approved drawings and scope of work. |
| 55 | 2C x 25 / 10 sq.mm LT XLPE UG Cable |
| 56 | 4C x 25 sq.mm LT XLPE UG Cable |
| 57 | 4C x 95 sq.mm LT XLPE UG Cable |
| 58 | 4C x 150 sq.mm LT XLPE UG Cable |
| 59 | 4C x 300 sq.mm LT XLPE UG Cable |
| 60 | suitable glands, lugs for 2C x 25 / 10 sq.mm |
| 61 | suitable glands, lugs for 4C x 25 sq.mm |
| 62 | suitable glands, lugs for 4C x 95 sq.mm |
| 63 | suitable glands, lugs for 4C x 150 sq.mm |
| 64 | suitable glands, lugs for 4C x 300 sq.mm |
| 65 | LT Feeder Pillars - Main & Mini |
| 66 | LT Distribution Feeder Pillars (Main) - 8 Way, 1200 Amps Busbar rating with 4 Poles , 3 Phase , 415V, 1000A2 Nos. Incomer HRC Fuse units and outgoing HRC Fuse units ( 3Ph +1N+E - 125,100,80,63,32 & 16 Amps ) andrated neutral links in suitable cubicle fitted for outdoor applications, as per technical specification, approved drawings and scope of work. |
| 67 | LT Distribution Feeder Pillars (Mini) - 8 way, 900 Amps Busbar rating with 4 Poles , 3 Phase , 415V, 630A 2 Nos. Incomer HRC Fuse units and outgoing HRC Fuse units ( 3Ph +1N+E - 100,80,63,50,32 & 16 Amps ) and rated neutral links in suitable cubicle fitted for outdoor applications, as per technical specification, approved drawings and scope of work. |
| 68 | Supply of 150mm Dia HDPE Pipe PN6, Grade 80 for LTCable as per detailed Technical Specification, approved Drawing & Scope of works for the below cables. |
| 69 | Miscellaneous |
| 70 | APFC Panel |
| 71 | Design, supply, installation, testing and commissioning of APFC panel 11kV,60KVAR, at DT locations up to 200 KVA Transformer capacity , 160A Incomer , 5 Nos. of Stage contactors as per technical specification, approved drawings and scope of work. |
| 72 | Design, supply, installation, testing and commissioning of APFC panel 11kV,120KVAR, at DT Locations above 200 KVA Transformer capacity , 315A Incomer , 10 Nos. of Stage contactors as per technical specification, approved drawings and scope of work. |
| 73 | DISTRIBUTION TRANSFORMERS & DISTRIBUTION BOARDS |
| 74 | 25kVA, 11 /0.433 kV , 3Phase , 50 Hz ONANCooledAluminium wound, Energy efficiency Level-1, Outdoor transformer having vector group of Dyn11, first fillof oil, Bushing on both HT & LT sides with standard fittings conforming to IS 1180 and AB Switch, Drop out fuses, earthing provision, LA\"s as per technical specification, approved drawings and scope of work. |
| 75 | 63kVA, 11 /0.433 kV , 3Phase , 50 Hz ONANCooledAluminium wound, Energy efficiency Level-1, Outdoor transformer having vector group of Dyn11, first fillof oil, Bushing on both HT & LT sides with standard fittings conforming to IS 1180 and AB Switch, Drop out fuses, earthing provision, LA\"s as per technical specification, approved drawings and scope of work. |
| 76 | 100kVA, 11 /0.433 kV , 3Phase , 50 Hz ONANCooledAluminium wound, Energy efficiency Level-1, Outdoor transformer having vector group of Dyn11, first fillof oil, Bushing on both HT & LT sides with standard fittings conforming to IS 1180, as per technical specification, approved drawings and scope of work. |
| 77 | 160kVA, 11 /0.433 kV , 3Phase , 50 Hz ONANCooledAluminium wound, Energy efficiency Level-1, Outdoor transformer having vector group of Dyn11, first fillof oil, Bushing on both HT & LT sides, off load tappings of +5% to -10% in steps of 2.5%with standard fittings conforming to IS 1180, as per technical specification, approved drawings and scope of work. |
| 78 | 200kVA, 11 /0.433 kV , 3Phase , 50 Hz ONANCooledAluminium wound, Energy efficiency Level-1, Outdoor transformer having vector group of Dyn11, first fillof oil, Bushing on both HT & LT sides, off load tappings of +2.5% to -5% in steps of 2.5%with standard fittings conforming to IS 1180, as per technical specification, approved drawings and scope of work. |
| 79 | 250kVA, 11 /0.433 kV , 3Phase , 50 Hz ONANCooledAluminium wound, Energy efficiency Level-1, Outdoor transformer having vector group of Dyn11, first fillof oil, Bushing on both HT & LT sides, off load tappings of +5% to -10% in steps of 2.5%with standard fittings conforming to IS 1180, as per technical specification, approved drawings and scope of work. |
| 80 | New LT Distribution Boards for 100kVA to 500kVA 3 Phase Distribution Transformers full load current up to 630Amps, as per technical specification, approved drawings and scope of work. |
| 81 | Miscellaneous |