| 1 | Notes : (i) The work consists of 04 jobs as under:- JOB (A) : SO(K)/14/2022-23/LBW,JOB (B) : SO(K)/02/2022-23/SPL REP E/M, JOB (C) : SO(K)/17/2022-23/SPL REP E/M & JOB (D) : SO(K)/15/2022-23/LBW(ii) Please refer schedule \"A\" notesbefore quoting the tender.(iii) Amount of Schedule of Credit shall be deducted off line by the department. B&R ITEMS FOR JOB \"A\" |
| 2 | Complete removal of existing PVC tiles /sheets, of any description in any position including cleaning, wire brushing, watering, removal of debris upto 1500mtr distance complete all as specified and as directed |
| 3 | M&L for 2mm thick polymer natural / synthetic anti static flooring fire retardant compression moulding conductive flooring having electrical resistance floor surface to earth between 50 kilo Ohms to 2.5 mega Ohms measured with wet electrode in accordance with details contained inSTEC pamplet No 7 fixed over and includingcopper strip grid work using 50mm x 0.5mm thick forming 0.9sqm grid, joints of copper strips, brazed on the existing surface including cleaning & preparation of surface by pasting with suitable adhesive.The copper grid provided with diagonal earthing.The earthing resistance shall not exceed one ohm.The copper strip work shall be fixed to the existing floorat the 0.6m to 0.9m all as per manufacturer instructions complete all as specified and as directed. |
| 4 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed. |
| 5 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight,mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,also including powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts, hooks & eyes, peg stays and handles, concealed star lock for aluminium window, Mortice lock vertical type size 100mm 04 lever for door, rubber beading suitable for fixing 4mm / 5mm thick glass in aluminium window / doorsincluding connected items,with and including making good to the disturbed portion with its original specificationscomplete all as specified and directed. |
| 6 | M&L in repairs double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other plart made of mild steel heavy duty and fixed complete all as specified and directed. |
| 7 | M&L 4 mm thick plain glass sheets ordinary quality in any size, each pane n.exc 0.5 sqm fixed with rubber beading or oil putty for windows/doors/partition etc complete all as specified and directed. |
| 8 | M&L 12mm thick prelaminated particle board, exteriorgrade, prelaminated both sides with deocrativelaminationfixed with screws to timber frame work complete all as specified and directed. |
| 9 | E&M ITEMS FOR JOB \"A\" |
| 10 | Supply, fixing, stringing and drawing submain wiring with 4 run of single core 10 Sqmm PVC insulated and unsheathed, multi stranded FRLS copper conductor cable using colour code for phase RED, YELLOW, BLUE and neutral black with and including 1 x 10 Sqmm PVC insulated and unsheathed copper conductor multistranded cable in green colour connected to common earth point and connected to earth dolly, drawn through suitable size of PVC conduit heavy grade with and including all accessories etc compete all as specified and directed.NOTE:-4 runof 10 sqmm, 1 run of 10 sqmm earth continuity conductor and suitable size of PVC conduit and accessories shall be measured and paid as one length. |
| 11 | S&F in repairs MCB SPN distribution board sheet steel, phosphorised powder painted MCB DBs with busbar neutral link, earth bar and DIN rail conforming to IS, 4 way double door, 230 volts, 50 HZ, AC complete all as specified and directed. |
| 12 | S&F in repairs TPN MCB 415 V 50 Hz 10 KA confirming to IS 8828 of rating 63 Ampcomplete all as specified and directed. |
| 13 | S&F Copper strip 32 x 6mm with saddles and fixing screws including insulators on wall complete all as specified and directed.Note : Rate of Insulators deemed to be included in quoted rate of the item. |
| 14 | E&M ITEMS FOR JOB \"B\" Note : BOQ Serial Item No 2.01 to 2.06 shall be taken on ledger charge & RV issued. |
| 15 | Supply only Metallic body exhaust fan 300 mm sweep, single phase, 900 RPMcomplete all as specified and directed. |
| 16 | Supply only Metallic heavy duty exhaust fan 380 mm sweep, single phase, 900 RPMcomplete all as specified and directed. |
| 17 | Supply only Metallic heavy duty exhaust fan 450 mm sweep, single phase, 900 RPMcomplete all as specified and directed. |
| 18 | Supply only Pedestal fans air circulators 400mm sweep heavy duty, 230V, 50Hz, with all accessories complete all as specified and directed. |
| 19 | Supply only Pedestal fans air circulators 450mm sweep heavy duty, 230V, 50Hz, with all accessories complete all as specified and directed. |
| 20 | Supply only Pedestal fans air circulators 750mm sweep heavy duty, 230V, 50Hz, with all accessories complete all as specified and directed. |
| 21 | Supply only electric water heater (White), storage type steel body with copper inner tank and heatuig element upto 2KW capacity 25 Ltr, BEE 5 star rated complete with all acecesires such as satey valve, thermostate, NRV, connection piece etc complete all as specified and directed. |
| 22 | E&M ITEMS FOR JOB \"C\" |
| 23 | Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixture and fittings such as switches, sockets complete. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls complete all as specified and directed. |
| 24 | Disconnecting and taking down carefully Split/Window type air conditioning unit of Capacity 1.5 Ton/2 Ton, electrically / mechanically and lowering to the ground from any position, transporting to AGE E/M-II Store yard for safe custody complete all as specified and directed. |
| 25 | Disconnecting Carefully Water cooler and Deep freezer of any type/size electrically / mechanically and transporting to AGE E/M-II Store yard for safe custody complete all as specified and directed. |
| 26 | Supply, install, testing and commissioning of Air Cooled Invertor Split typeAir Conditioner min 3 star rating of capacity 1.5 ton, electric driven (230 volts, 50 Hz,single phase supply), comprising of indoor unit, wall mounted, material of construction of indoor unit ABS, outdoor unit material of cabinet GI sheet 1.0 mm thick, powder coated, Condensor copper tubingtype including copper tubing and connection cable complete between indoor and outdoor with the following specification complete all as specified and directed. a) Rated cooling capacity (Min-Max) (Watts)-5010 (1296-5158)b) Air flow Volume (Wet CFM) (High/Medium/Low) -400/318/250c)Noise level Indoor (High/Medium/Low) dB(A) -42.7/36.8/31.6d) Compressor type-Inverter Rotary with 10 year warranty.e) Refrigerant type-R-32 (Eco Friendly)f) Remote type-Cardless LCD Display. |
| 27 | Supply, install, testing and commissioning of Air Cooled Invertor Split typeAir Conditioner min 3 star rating of capacity 2.0 ton, electric driven (230 volts , 50 Hz,single phase supply), comprising of indoor unit, wall mounted, material of construction of indoor unit ABS, outdoorunit material of cabinet GI sheet 1.0 mm thick, powder coated, copper tubing condensor type including copper tubing and connection cable complete between indoor and outdoor with the following specification all as specified and directed by Engineer-in-charge. Make- Carrier/Daikin/Hitachi/Voltasa) Rated cooling capacityWatts(Min-Max) -6350 (1772 -6624)b) Air flow Volume (Wet CFM) (High/Medium/Low)-576/501/399c)Noise level Indoor (High/Medium/Low) dB(A)-46.63/43.7/37.7d) Compressor type-Inverter Rotary with 10 year warranty.e) Refrigerant type-R-32 (Eco Friendly)f) Remote type-Cardless LCD Display.Note for Item No: Copper cable, Copper tubing of dia 1/2\" for suction line and 1/4\" discharge lineincluding thermal insulation and other brass fitting (between indoor and out door unit mindistance 3.0 mtrs and condensed water drainage pipe system is inclusive of quated rate and more than 3.0 Mtrs will be measured and paid separetely under relevent item of schedule. |
| 28 | S&F Copper tubing of dia 1/2\" for suction line including thermal insulation and other brass fitting, fixing into wall etc complete all as specified and directed. |
| 29 | S&F Copper tubing of dia 1/4\" for discharge line including thermal insulation and other brass fitting, fixing into wall etc complete all as specified and directed. |
| 30 | S&F powder coated iron stand for supporting the outer unit set of two of split air conditioning including all accessories required for fitting/hanging the stand into the wall complete all as specified and directed. |
| 31 | Supply, installation, commissioning of Energy efficient water cooler fully stainless steel, electric driven , single phase, having approx storage capacity 80 ltrs and nominal cooling capacity of 40 liters per Hour with RECIP Compressor working on R-134 (a) refrigerant complete all as specified and directed. |
| 32 | Supply, Installation and commissioning of glass top Deep freezer, electric driven (Single phase) of capacity 400 Ltrs or nearhigher size, double door, min 3 star working with latest Eco friendly refrigerant complete all as specified and directed. |
| 33 | Supply, Installation Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & Designed for input voltage 170 V to 250 Volts with output voltage stabilized at 230 Volts with accuracy of plus or minus 2.5 % and of capacity 5KVA complete all as specified and directed. |
| 34 | M&L for Point wiring with1100 Volts, grade FRLS, 2.5 Sqmm. (nominal area) wire/cable for phase and neutral for 3 Pin 5, 3 pin 15 amp socket on independent board including PVC Caping Casing (medium duty)20 mm or higher size complete with all accessories with concealed pressed iron/steel suction box of thickness 1.2mm for mounting of switch socke combination with 3 mm thick plastic laminated sheet as top cover incl one 1.5 sqmm PVC insulated unsheathed multi stranded copper conductor cable, FRLS 1100 volts grade as earth continuity conductor upto common earth & connected to earth dolly complete all as specified and directed. |
| 35 | S&F Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flushtype universal SP 250 Volt AC complete all as specified & directed. |
| 36 | M&L for sub main wiringwith 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) drawing in and including 20 mm dia PVC Caping CasingIncluding one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 4.0 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain complete all as specified and directed. |
| 37 | S&F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 10 KA C series complete all as specified and directed. |
| 38 | S&F in repairs PVC Insulated unsheathed copper conductor 3 core 2.5 Sqmm round sheathed multicore industrial cable for voltage gradeupto 1100 complete all as specified and directed. |
| 39 | B&R ITEMS FOR JOB \"D\" (i) - (PROVN OF GARBAGE BIN) |
| 40 | Surface excavation n exc 30 cm deep and avg 15 cm deep and getting out in type of soil complete all as specified and directed. |
| 41 | Excavating in post holes (or similar holes) each n exc 0.5 cum getting out ,returning,filling in and ramming earth or broken rubble mixed with earth ,in layers n exc 25 cm ,watering and removing surplus soil to a distance n exc 50 m and making good surface in any type of soil complete all as specified and directed. |
| 42 | Excavation in trenches n.exc 1.5m wide & 1.5m depth and getting out in any type of soil complete all as specified and directed. |
| 43 | Returning filling in including spreading leveling watering & well ramming in layers n.exc 25cm thick complete all as specified and directed. |
| 44 | Removal of excavated material (soil) to a distance not exceeding 50mand depositing where directed at a level not exceeding 1.5meter above the starting point complete all as specified and directed. |
| 45 | M&L PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation,fillingand mass concrete complete all as specified and directed. |
| 46 | M&L for pre-cast cement concrete block masonry with solid blocks in 10cm in width in type B1 (1:2:4) using (20mm graded aggregate) and setting in mortar (1:6) complete all as specified and as directed |
| 47 | M&L for Cement Concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) as in foundation, fillings and mass,concrete complete all as specified and directed. |
| 48 | M&L for hard core broken stone of guage n exc 63mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 49 | M&L for PCC 1:4:8 type D-2, 100mm thick using 40mm graded crushed stone Agg as in sub base etc complete all as specified and directed. |
| 50 | M&L for Non skid colouredceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in floorsover & including screed bed or bedding layer 15 mm thick in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed. |
| 51 | M&L for Glazed ceramic tiles in vertical surface 350mmx250mm x7mm / 450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with & including 10 mm thick rendering or bedding layer in cement mortar 1:4 complete all as specified and directed. |
| 52 | M&L for chequered cement concrete tile 30cmX30cmX 20 to 25mm thick set jointed and pointed in neat cement siurry in floor with grey cement and pig ments overincluding 15mm thick screed bed or bedding layer of CM (1:6)complete all as specified and as directed. |
| 53 | M&L for PCC (1:3:6) type C1 using 20mm graded stone aggregatein coping bed black etc including necessary form work complete all as specified and directed. |
| 54 | S&F Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 Grade St-240 complete all as specified and directed. |
| 55 | M&L for Framed work such as grills, gratings, sun shed etc with ends of bars shouldered and/or riveted or welded, or forged into spikes, framed guard bars, barred iron doors, ladders, farmed balastures, walk ways, railings, frame work of water tanks and similar work conforming to Fe-410-0 or Fe-310-0 complete all as specified and directed. |
| 56 | S&F Welded steel wire fabric n exc 4 kg per Sqm supplied and fixed complete to wood or steel members complete all as specified and as directed |
| 57 | S&F Pre-painted galvalume aluminium zink coating GI based corrugated steel sheet .50mm thick of colour as approved having tensile strenth of 550 Mps as in roof covering /clading to wall fixed with self taping screw complete all as specified and directed. |
| 58 | M&L for preparing new or previously untreated steel surface of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 59 | B&R ITEMS FOR JOB \"D\" (ii) - (PROVN OF FALSE CEILING AT BLDG NO P-68) |
| 60 | S&F for PVC False ceiling consisting of 600 mm x 600 mm, 10 mm thick prelaminated self design hollow PVC panel including frame work made using aluminium T section of size (25mm x 25 mm, 19 gauge or 1mm thick) in square pattern of grid size of 600 x 600 mm. The aluminium frame work is supported from the ceiling with the help of GI wire/6 mm dia GI (upto 1200 mm length) adjusting and maintain for proper level to roof salbs by means of ceiling cleats made out of GE flat 40x3 mm sie 60mm long and expansion hold fasterners 12.5mm dia 40mm long complete etc. The aluminium frame work is supported on side wall with the use of aluminium 25 mm X 25 mm angles complete all as specified and directed. |
| 61 | S&F 25mm thick boned mineral wool blanket slab made from glass density 24 Kg/ Cum and fixed as per manufacturer\"s instruction, complete all as specified and directed. |
| 62 | E&M ITEMS FOR JOB \"D\" (iii) - (PROVN OF VOLTAGE STABLIZER) |
| 63 | Supply, installation, testing and commissioning of static voltage stabilizer 100 KVA for automatic IGBT controlled ( unbalanced load), microprocessor based digital 3 phases, 4 wire, Air cooled, indoor type and designed for input variation between 360 V to 468 V with output voltage stabilized at 415 V with accuracy + 1 % (P-P) complete all as specified and directed with following:- (a) Type - IGBT static voltage stabilizer indoor(b) Rated Freq 50 HZ.(c) Wave form distortion: Nil.(d) Response time not to exceed 10 milliseconds.(e) Duty cycle: continuous 100 % loading at lowest input voltage for indefinite time.(f)Rate of correction: greater than 3000 volts/sec, the said voltage regulator should sense as well as correct any voltage sag/ fluctuation within 20 milliseconds, i.e. one wave form.(g) Overload capacity 125 %, it should be take startup load with high in rush currents.(h) Efficiency: greater than 96 % at 100 % and highest voltage input.(j) Type of load- Three phase unbalanced type.(k) Digital display voltmeter/ Ammeter.(l) Cooling type : Air cooled |
| 64 | BOQ serial Item No 4.23 contd:-(m) Protections :-(i) MCCB/MCB for overload and short circuit protection.(ii) Integral bypas and Manual bypass arrangement.(iii) Voltage regulations shall be performed by IGBT driven PWM invertor operating at aroung 20 KHZ switching frequency with typical voltage correction time 20 MS ( one cycle for 50 HZ supply)so that output voltage with the requirement of ITIC curve for regulated voltage supply to electronic machinery. (iv)Voltage regulation should be achieved by superimposition of PWM wave on incoming wave, without and break in the power path. |
| 65 | Supply, laying, jointing, connecting & testing intrenches XLPE/PVC insulated PVC sheathed cable of size 120 Sqmm x 3.5 core heavy duty1100 volts grade, aluminum conductor in trenches / ducts /on wall surface as complete all as specified and directed. |
| 66 | M & L earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mmthick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test pointincluding testing on completion & dismantling/ taking out old existing earthing complete all as specified and directed Note :-(i) GI strip & protection pipe upto 7.5 m is deemed to be inluded in quoted rate (ii) The earth chamber shall be constructed 50 cm away from the edge of earth pit & the cost of the same is deemed to be included in rate quoted for above items.(iii)The rates quoted are also deemed to be included for cost of new test point as specified. |