| 1 | Dismantling of RCC postsor struts of any section including taking out embedded portion and making good of disturbed ground (posts embedded in natural ground) etc complete all as specified and directed |
| 2 | All as per item above here-in-before but posts embedded in concrete. |
| 3 | Dismantling chain link fencing of any type fixed in any situation including flat iron MS round bars, mounted on nuts & bolts etc complete all as specified and directed |
| 4 | M/L for providing PCC (1:4:8) type C2 using (40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed |
| 5 | S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed |
| 6 | Supply only, chain link fencing of MS galvanized fencing, any size or type complete all as specified and directed |
| 7 | Fixing only chain link fencing including line wires, any mesh , size and type fixed to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed Note : Supply only chain link fencing and line wire will be measured and paid separately. |
| 8 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed to other, or screwed both ends, each screwed end to be fitted with washers and hexagonal or square nut length of bolt exc 10cm but n.exc 20cm long and dia of neck 11 to 15mm complete all as specified and directed |
| 9 | M&L Mild steel round bars, 10mm dia cut to length wearied and securing chain link fencing to fencing posts complete all as specified and as directed |
| 10 | S&Fgalvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing\"s and straining and fixing to any type of standard rails straining bolts including, securing and tying at crossings with and provisions of galvanised mild steel wire staples or steel pins etc as directed (each line wire to be measured). |
| 11 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or othercovering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and as directed |
| 12 | Dismantling structural steel work including doors, gates but excluding framedtruss etc complete all as specified and as directed |
| 13 | M&L for preparation of new steel surfaces and apply two coats ofsynthetic enamel paint over a coat of red oxide primer over 10 cm in width or girth of surfaces complete all as specified and directed. |
| 14 | Supply and Laying at different locationfor spread & levelled in layers not exceeding 15cm thick (Spreadthickness) to a true surface only nominal size graded coarse aggregate of gauge 40 mm deposited complete all as specified and as directed |
| 15 | Supply and Laying at different locationfor spread & levelled in layers not exceeding 15cm thick (Spreadthickness) to a true surface only nominal size graded coarse aggregate of gauge 20 mm deposited complete all as specified and as directed |
| 16 | Demolition of stone masonary of any description and in any position, built in cement mortar, including all quoins, arches and pillars etc complete all as specified and as directed |
| 17 | M&L for squared rubble walling Jodhpur type brought upto course well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and as directed |
| 18 | M&L for squared rubble walling Jodhpur type brought upto course well bonded, bedded and solidly hearted built in cement mortar (1:6) but except stone complete all as specified and as directed |
| 19 | Extra over of hammer dressing to face stone with maximum depression on face from straight edge not exc 20mm and dressing face bed and joints as specified to squared rubble walling jodhpur type brought upto cources complete all as specified and as directed |
| 20 | Racking out joints/pointing to square rubble masonryJodhpur type regular coursed built in cement mortar complete all as specified and as directed |
| 21 | M&L for keyed pointing to square rubble masonryJodhpur type regular course in CM (1:3) complete all as specified and as directed |
| 22 | M&L for applyingtwo coats of cement base paint over a coat of primer on walls including preparation of newly plastered/ pointed surface complete all as specified and as directed |
| 23 | M&L PCC (1:3:6) type C1 using 20mm graded aggregate as in coping including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed |
| 24 | M&L Broken glass coping on top of walls in CM 1:3 complete all as specified and as directed |
| 25 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness(below or above ground level) etc complete all as specified and as directed |
| 26 | M&L for75 mm thick PCC , (1:4:8) type D-2, (using40mm graded stone aggregate) as in sub base for floor complete all as specified and as directed |
| 27 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed |
| 28 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed |
| 29 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), includingmaking drainage opening wherever required complete all as specified and as directed |
| 30 | Dismantling floor, hearth or wall tilingof any description and in any positionincluding cement mortarbedding (but not backing) complete all as specified and directed. |
| 31 | M&L for Rubberised Chequered cement concrete tiles 30cmx30cmx25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigment, in floors, over and including 15 mm thick screed bed orbedding layer of cement mortar (1:6)complete all as specified and directed. |
| 32 | Demolition of ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling built in cement mortar, including all quoins, arches and pillars etc complete all as specified and as directed |
| 33 | M&L for Pre-cast cement concrete (1:5:10) using 20 mm graded stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in CM 1:6, complete all as specified and directed. |
| 34 | M&L for Pre-cast cement concrete (1:5:10) using 20 mm graded stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in CM 1:6, complete all as specified and directed.(but except blocks) |
| 35 | M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces complete all as specified and directed. |
| 36 | M&L for PCC 1:3:6 using 20mm graded stone aggregate as in surface channelsand drains complete all as specified and directed. |
| 37 | M&L for 15 mm thick rendering in cement mortar 1:4 on stone masonry surface (Internally) of walls mixed with WPC, as per manufacturer’s direction and finished the surface even and smooth without using extra cement complete all as specified and as directed |
| 38 | Supply only integral water proofing compound. |
| 39 | M&L for 15 mm thick rendering in cement mortar 1:6 on stone masonry external surface of wallsfinished the surface even and smooth without using extra cement complete all as specified and as directed |
| 40 | M&L for plain cement concrete 1:2:4 using 20 mm graded crushed stone agg as in surface channel/drain and benching andManholes complete all as specified and as directed |
| 41 | Material and labour for plain cement concrete 1:3:6 type C-1using 20mm graded crushed stone agg as in coping of manhole including necessary form work complete all as specified and as directed |
| 42 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and as directed |
| 43 | Cutting and grubbing of bushes grass and tree surrounding manholes, Gully trap, bend, wall pipe, overhead tank and sewage line alignment, security fencing, building etc and levelling of ground around the manholes, sewage line and finish the surface of walland removing the waste material to a distance exc 50m and n exc 500m and clearing the site complete all as specified and as directedNote :-(i) All TP (likeJCB or else) and equipment’s are required for clearance of site, safety shall be arranged and made available by the contractor.(ii) All safety measures for workmen to do work shall be provided by the contractor. (iii) Any other existing govt assets(Like electric cables, water pipeline storm water drain boundary walls etc) are damages during the site clearance/excavation contractor should be repair at same time without any delay. (iv) Contractor (bidder) shall note understand that the rate quoted by him & in r/o of site clearanceitems shall be deemed included in quoted rate and no extra on this account is admissible. |
| 44 | Cleaning/ taking out sludge/ mud/ silt from manhole and septic tanks of any size, depth and capacity by manually or mechanically in foul condition including dewatering septic tank and manholes when ever required including removing of sludge/muds/siltin a closed container vehicle to a distance outside MD land and or buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and as directedNote:- Sludge/ muds/ silt including water shall be measured before taking out from manholes/ septic tank. |
| 45 | Cleaning of existing drain pipes 150mm to 300mm dia at any depth by rodding manually/ mechanically as required at site from manhole and well finishing after cleaning including getting out sludge if any and liquid materials from connecting manholes deposited in lines removing the solid and sludge to any distance place outside the defence land at their own cost andrefaxing manhole covers etc, the cost of removal shall be included in the quoted rate complete all as specified and directed by Engr-in-charge. |
| 46 | Removing blockage including cleaning of SGSW / PVC/ CI pipe upto and including 100 mm bore from kitchen/ bath/ wash hand basin/ urinal/ WC of any length upto gulley trap by rodding/choke remover manually or otherwise including removing & refixing of oval access door cover (up to 6.00mtr height) complete all as specified and as directed |
| 47 | Removing blockage including cleaning of SGSW / PVC/ CI pipe upto and including 100 mm bore in any length from gulley trap to 1st manhole by rodding / choke remover, manually or otherwise including removing & refixing manhole covers of 1st manhole complete all as specified and as directed |
| 48 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed |
| 49 | Demolition of cement concrete of any description and in any position not otherwise described for (such as in bed, haunching & packing of sewer lines, benching of manholes, copings etc.) complete all as directed and removal of debris outside the premises complete all as specified and as directed |
| 50 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and as directed Note:- Excavation and earth work shall be measured andpaid separately. |
| 51 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 200mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and as directedNote:- Excavation and earth work shall be measured andpaid separately. |
| 52 | S&F 150 mm bore Reinforced cement concrete pipes, ISI marked, one end socketed, class NP-2, laid in trenches and jointed in cement mortar (1:1) complete all as specified and as directed |
| 53 | M&L for Reinforced concrete pipes, 200mm bore, class NP-2, ISI marked laid in trenches and jointed in cement mortar (1:1) as specified complete with collars complete all as specified and as directed |
| 54 | M&LPCC 1:4:8 type D-2 (using 40 mm graded crused stone aggregate) as in bed to 150 mm bore salt glazed stone ware drain pipe includingpacking under and haunching against the side ofpipe after they are laid and tested complete all as specified and as directed |
| 55 | .-ditto- but 200mm dia |
| 56 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm soft/loose soil complete all as specified and as directed |
| 57 | Removing excavated material/soil not exceeding 50 meter and depositing where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed |
| 58 | S&F 450mm bore reinforced concrete pipes, class NP2, ISI marked, laid and jointed in cement mortar (1:1)complete with collars complete all as specified and as directed |
| 59 | S&F as in repair precast steel fibre reinforced concrete (SRFC) any colour 75-100 mm thick manhole cover with frames (ISI marked) of overall covered area not exceeding 1.00 Sqm with clear opening not less than 0.36 Sqm, any shape (round, square, rectangular etc) provided with suitable mild steel rims to prevent from chipping of edges and enable clear opening with provision of easy lifting hooks which are duly protected against corrosion laid over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directedNotes :- (i) The contractor or his represantative will report in complaint cell to receive the complaints in the morning by 0900hrs with necessary daily stores and are required to attend day to day complaints.(ii) The complaints should be attended/ completed within 48hours after receiving the complaint slip failing which penalty of Rs. 500/- will be recovered for each complaint per day from the contractor payment.(iii) The cost of masson, plumber & carpenter should be deemed to be included in the item rates quoted by the contractor nothing will be paid extra for hiring the skilled labour.(iv) All safety measures will be provided by contractor during the working period. If any accident occurs, only the contractor will be held responsible for all.(v) Work place in this subject work more than one story building if any scaffolding required no extra payment made to contractor. |