| 1 | AGE E/M SCHEDULE - SHILLONG CANTTTaking down and dismantling of street/security/posttop light fittings of any type size and model (FTL, HPSV, MVL, MH,floodlight , LED Fittings etc), and check at the site in the presence of MES rep, repaire at the site with replacement of spare parts ( wire, drivers, choke etc) and refixing after cleaning and testing. If not found repaireble than depositing the same to MES store yard for replacementas directed by Engr in Charge complete.Note :- The Quoted rates shall to be included for the following :-(a) As the above work is required to be carried out for repair/maint of street/security/posttop light fittings entire Cantt area Shillong , hence complaints of the US street/security/posttop light fittings to be handed over daily basis (if received) for different units locations and repairs to be carried out on the same day or next day or as directed by Engr-in-Charge.(b) The contractor shall depute adequate well knowledge electrician and helper (As per the complaint) with all connected tools on daily basis (if required) with suitable vehicle & T&P arrangement to repairs and attend the complaints in various units under AOR of GE Shillong and manage all spares included in this CA in advance or as directed by Engr-in-Charge. (c) Non attending the complaints with in 48 hrs Rs 100/- per day per complaints shall be recovered. |
| 2 | Supply and fixing of driver for LED luminary suitable for single phase 45 wattscomplete incl taking out of fitting from pole and refixing after repair complete all as per existing specification Make as per fitting fixed at site complete all as specified and as directed. |
| 3 | Supply and fixing of driver for LED luminary suitable for single phase 60 wattscomplete incl taking out of fitting from pole and refixing after repair complete all as per existing specification Make as per fitting fixed at site. |
| 4 | Supply and fixing of driver for LED luminary suitable for single phase 25 wattscomplete incl taking out of fitting from pole and refixing after repair complete all as per existing specification Make as per fitting fixed at site. |
| 5 | Supply and fixing of driver for LED Bollard 08 watt complete incl taking out of fitting and refixing after repair complete all as per existing specification Make as per fitting fixed at site. |
| 6 | Supply and fixing of driver for LED Bollard 09 watt complete incl taking out of fitting and refixing after repair complete all as per existing specification Make as per fitting fixed at site. |
| 7 | Supply & fixingin repair Gate / Post Top lantern LED lights fitting of capacity 20 W die-cast aluminium body, 20 watt LED 3000/5700K and toughened glass complete with all accessories incl taking out old unserviceable onecomplete all as specified and as directed. |
| 8 | Supply & fixingin repair Gate / Post Top lantern LED lights fitting of capacity 40 W die-cast aluminium body, 40 watt LED 3000/5700K and toughened glass complete with all accessoriesincl taking out old unserviceable onecomplete all as specified and as directed. |
| 9 | Supply & fixingin repair Garden light/LED Bollard LED lighs fitting of capacity 09 W die-cast aluminium body, 09 watt LED 3000/5700K and toughened glass complete with all accessories incl taking out old unserviceable onecomplete all as specified and as directed. |
| 10 | Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD, high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete suitable for GI bracket of dia 43 mm all as directed by Engr-in-Charge (Note : 03 years warranty certificate to be provided by Contarctor) |
| 11 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD, high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete suitable for GI bracket of dia 43 mm all as directed by Engr-in-Charge |
| 12 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp fixed on wall/roof/pole/floor/highmast with the help of nuts, bolts , washers and clamps etc all as directed by Engr-in-Charge |
| 13 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed. |
| 14 | Excavation in trenches not exceeding 1.5m wide and exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed. |
| 15 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in hard/dense soil complete all as specified and as directed. |
| 16 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. |
| 17 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. |
| 18 | M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set /Pole/ FPB etc including fair finish even and fir to exposed surfaces without using extra cement complete all as specified and as directed. |
| 19 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed. Note :- Only punned down sand shall be measured. |
| 20 | M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. |
| 21 | Dismantling/taking out carefully of old LT cable of any size type or core and kept aside for reuse / rerouting / jointing / replacementetc complete all as specified and as directed. |
| 22 | Dismantling/taking out carefully of old bricks any size type kept aside for reuse / rerouting / jointing / replacementetc complete all as specified and as directed. |
| 23 | Layingonlyserviceablebricksforprotectionofcable obtainedduringexcavationfromitemNo. 73 above complete all as specified and as directed.e. |
| 24 | M & L laying or passing through pipe LT UG XLPE insulated, armoured heavy duty 1100 volts grade with aluminumstranded conductor of cross sectional area 16 sq mm 4corecomplete all as directed. |
| 25 | All as per Item No 75 here and above but 10 sqmm 4 core complete all as specified and as directed.Make:- HAVELLS/KEI/Polycab |
| 26 | All as per Item No 76 here and above but 10 sqmm 2 core complete all as specified and as directed.Make:- HAVELLS/KEI/Polycab |
| 27 | Supply and fixing/laying40mm bore, steel tubings,galvanised, light grade with all fitting laid across road , in trenches or across PCC drain oralong electric pole or floor/wall etcfor protection of cableincluding taking down old unserviceable one complete all as specified and as directed. |
| 28 | Dismantling existingsteel poles/ struts, any size carefully for reuse including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish complete all as specified and as directed. |
| 29 | M & L for Steeltubular swagedpolescompletewithcastiron/MSbaseplate , finialtaperplug , bolts , nuts & screwsasspecifiedtype 410 SP-22 , 8.5 meter long complete including PCC (1:3:6) type C2 (using 40 mm stone graded stone aggregate in foundation and copying with PCC (1:2:4) type B1 (using 20mm stone aggregate) complete all as specified & directed.Note: PCC anti climbing device, cross arms insulator, ACSR conductor and earth work measure and paid separately) |
| 30 | S&F in repair GI Bracket of dia 40 mm light grade with 1.2 mtr length including fixing the fitting removed for changing the bracket and connection with existing wire etc complete all as specified and as directed. |
| 31 | Supply and fixingPVC Insulated and sheathed three core Heavy duty cables 1100 volts 03 core having multi stranded aluminium conductor service cable size 4 sqmm complete all as specified and directed. |
| 32 | Supply & Fixing junction box inrepair made of polycarbonate with IP 65 degree of protection , dust proof, water tight, light weight, acid resistant, corrosion proof inslated & shock proof, fire retardant, self extinguishing, halogen & silica free non-toxic material, UV resistant, with internally ebbedded gasket fitted with required connector/terminals for upto size 25 sqmm 4 core cable and with openable front including Glands and Street light connection incl taking down old unserviceable one complete all as specified and as directed. |
| 33 | Supply and fixing in repair of street light timer panel made of polycarbonate body including Digital Timer Switch, 40/63A 3 phase Contactor, MCB and wiring if any required with min 1 Sqmm copper conductor cable and instrument wiring with 1.5 Sqmm fine, terminal blocks etc incl taking out old unserviceable one complete all as specified and as directed. |
| 34 | Supply & Fixing in repair of power contactor three pole 40/63 Amp 415 Volts din rail mounted type on existing panel complete all as specified and as directed.. Make BCH/Siemen/Scinder/L&T |
| 35 | Supply & Fixing in repair ofDigital TimerSwitch (Crono time switch) 110-240V AC 1 C/O - 2 Module on existing panel complete all as specified and as directed. |
| 36 | Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron wire of 4 sqmm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 15 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, Chequred plate cover plate of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar, funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SRR part 1 including testing on completion all as specified and directed. incl demolition to existing one complete. |
| 37 | Taking down lumanaries of High Mast and servicing the motor, gear, Chain etc and restoring the lumanaries to top of the mast of pole, including charges for machinery/hydra required for fixing at top position complete all as specified and as directed. |
| 38 | S & Fix LED light strip type of 20 mtrs length complete all as specified and as directed. |
| 39 | M & L laying or passing through pipe LT UG XLPE insulated, armoured heavy duty 1100 volts grade with aluminumstranded conductor of cross sectional area 6 sqmm 4 core complete all as directed Make:- HAVELLS/KEI/Polycab |
| 40 | M & LWiring inrepair for circuit / submainwiringalongwithearthwirein and includingPVCconduitwithFRPVCinsulatedThree core copperconductor, 2 x 1.5 Sqmm for Line and Neutral and 1 x 1.5 Sqmm for Earthduly thimbled at both ends insurfacecompleteincludingnecessaryMSclamps aftertakingdownoldu/s wiringof anycondition. |
| 41 | Taking down and dismantling of street light fittings of any type size and model (FTL, HPSV,MVL,MH, floodlight , LED Fittings etc), and depositing the same to MES store yard for repair/replacement if any required or as directed by Engr in Charge complete. |
| 42 | Supply and fixing of driver for LED luminary suitable for single phase 45 wattscomplete incl taking out of fitting from pole and refixing after repair complete all as per existing specification Make as per fitting fixed at site. |
| 43 | Supply and fixing of driver for LED luminary suitable for single phase 60 wattscomplete incl taking out of fitting from pole and refixing after repair complete all as per existing specification Make as per fitting fixed at site. |
| 44 | Supply and fixing of driver for LED Bollard 08 watt complete incl taking out of fitting and refixing after repair complete all as per existing specification Make as per fitting fixed at site. |
| 45 | Supply and fixing of driver for LED Bollard 09 watt complete incl taking out of fitting and refixing after repair complete all as per existing specification Make as per fitting fixed at site. |
| 46 | Supply & fixingin repair Gate / Post Top lantern LED lights fitting of capacity 20 W die-cast aluminium body, 20 watt LED 3000/5700K and toughened glass complete with all accessories incl taking out old unserviceable oneall as directed. |
| 47 | Supply & fixingin repair Gate / Post Top lantern LED lights fitting of capacity 40 W die-cast aluminium body, 40 watt LED 3000/5700K and toughened glass complete with all accessoriesincl taking out old unserviceable oneall as directed. |
| 48 | Supply & fixingin repair Garden light/LED Bollard LED lighs fitting of capacity 09 W die-cast aluminium body, 09 watt LED 3000/5700K and toughened glass complete with all accessories incl taking out old unserviceable oneall as directed. |
| 49 | Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD, high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete suitable for GI bracket of dia 43 mm all as directed by Engr-in-Charge (Note : 03 years warranty certificate to be provided by Contarctor) |
| 50 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD, high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete suitable for GI bracket of dia 43 mm all as directed by Engr-in-Charge |
| 51 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 52 | Supply&Fixing inrepairGlowsignBoardinBluebasewithWhite lettersincludingframeworkwith 0.7mmthickGIplainsheetincludingerrectionatsiteatanyposition &testingcomplete. (Note: Necessarynut,bolt,washers , fastner , weldingetc &internallightingandelectricalwiringetcrequireddeemedtobeincludedintotheitemrate.) |
| 53 | M & L Two coat of Aluminium paint after preparation of old surface of Steel/Iron electric LT poles including pole fittings with two coat of Aluminium paint such as cross arms of any description anti climbing devices nut bolts etc and white weather coat paint of PCC coping and painting 05 Nos of strips ofeach 30cm height of Yellow & Black synthetic enamel paint alternatively above coping including numbering of poles as specified and as directed. |
| 54 | M&L for drilling holehorizontally road under ( min 1 mtr) pavement hardstanding by treanchless technology using ultra sound technique and necessary machine suitable andincluding 150 mm dia HDPEpipe complete . |
| 55 | S&F in repair galvanized Iron Bracket of dia 25 mm light grade with 1.2 mtr length including fixing the fitting removed for changing the bracket and connection with existing wire etc all as directed. |