}

E-Tender For Electrical Work For Mru Lab., rishikesh-Uttarakhand

All India Institute Of Medical Sciences has published E-Tender For Electrical Work For Mru Lab.. Submission Date for this Tender is 12-07-2023. Electrical Maintenance Tenders in rishikesh Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

38379605
E-Tender For Electrical Work For Mru Lab.
Open Tender
Indian
Uttarakhand
Rishikesh
12-07-2023

Tender Details

E-Tender For Electrical Work For Mru Lab. 1 Supply And Fixing Dlp Pvc Trunking Of Size 105 Mm X 50 Mm, Non Flame Propagating With Electrical Insulating Characteristic, Ip 40, Ik 07 Wall Surface Fixing Type, Complete With Cover , Cover Joint , Base Joint , Internal Angles , External Angles, Flat Angles , End Covers Etc. As Required And Directed By Engineering Incharge. 2 Supplying And Fixing Suitable Size Modular Plate And Cover On Existing Dlp Pvc Trunking Of Size 105 Mm X 50 Mm , Including Providing And Fixing 3 Pin 6 / 16 Amps 2 Module Socket Outlet And 20 Amps, One Way 1 Module Switch, Connection Etc. As Required. 3 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Dlp Trunking / Surface / Recessed Steel / Pvc Conduit As Required.3X4 Sq Mm 4 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Dlp Trunking / Surface / Recessed Steel / Pvc Conduit As Required.6X4 Sq Mm 5 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Dlp Trunking / Surface / Recessed Steel / Pvc Conduit As Required.9X4 Sq Mm 6 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required 7 Wiring For Light / Power Plug With 4X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Alongwith 2 Nos. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 8 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B 9 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.2 X 10 Sq.Mm +1X6 Sq.Mm Earth Wire 10 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.4 X 10 Sq.Mm +2 X 6 Sq.Mm Earth Wire 11 Supplying And Fixing Of Flexible Db With 3 Row Of 14 Module , Suitable For Incomer Mccb Upto 160 Amp 4P, Ip 43, Ik 09 With Metal Door As Per Iec 61439-3 , Suitable For Flush Mounting And Surface Mounting , Completely Flexible To Organises The Distribution As Per Requirements With Shrouded Neutral And Earth Bars, Prefitted Masking Sheet, Reversible Door For Ip 43, Din Bar For Mounting Mcb’S ( But Without Mcb’S Andincomer ) As Required. 12 Providing And Fixing 4 Pole , 16 Ka , 160 A , 415V Mccb With Thermomagnetic Release And Terminal Spreaders, Adjustable Sensitivity And Tripping , Option For In Built Or Add On Module For Earth Leakage Protection In Existing Db Including Drilling Holes In Db, Complete With Connections, Testing And Commissioning Etc. As Required.& As Directed By Engineering Incharge. 13 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . & As Directed By Engineering Incharge. 8 Way ( 4+24 ) Double Door 14 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.& As Directed By Engineering Incharge.Single Pole 15 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.& As Directed By Engineering Incharge.Double Pole 16 Supplying And Fixing Following Rating, Four Pole, 415 V, Mcb / Mccb In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.& As Directed By Engineering Incharge. 63A 16Ka 4P 17 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Includingearthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) & As Directed By Engineering Incharge 12 Way Double Door 18 Supply , Installation, Testing And Commissioning Of 2X2 Led Panel Light With Following Specifications, Including Connection, Wiring With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required.Main Housing: Crca, Internal Wiring:- Industrial Grade Copper Wire , Hardware:- Ss / Ms Ingress Protection:- Ip20, Lumen Maintenance:- 50000Hr@70, Operating Temperature:- ( 0-50 ) Deg. C, Rated Voltage & Frequency:- 240, 50 Hz Ac, Wattage:- 36 Watt, Pf: >=0.95, Ithd :- <10%, Luminous Efficacy ( Lm / W ) :- >=120, Cct:- >5700K, Cri :- >80, Operating Voltage:- 140V -300V, Lumen ( Lm ) :- 4000-4400, Surge Protection :- >=2Kv , Size Mm:- L 595Mm X W 595 Mm X H ( 60 To 80 ) Mm, Mounting:- Suitable For Armstrong / Grid Ceiling, Driver Location: External. 19 Supply, Installation, Testing And Commissioning Of 15 Watt Round Light With Following Specifications, Including Connection, Wiring, Ceiling Cutting With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required.Cut Out Size :- 180-185 Mm, Internal Wiring :- Industrial Grade Copper Wire, Hardware :- Ss / Ms , Ingress Protection :- Ip20, Lumen Maintenance :- 50000Hr@70, Operating Temperature :- ( 0-50 ) Deg. C, Rated Voltage & Frequency :- 240, 50Hz Ac, Wattage :- 15 Watt , Pf :- >=0.95, Ithd :- <10%, Cct :- >5700K, Cri :- >80, Operating Voltage : 140V -300V, Lumen ( Lm ) :- :- 4000-4400, Surge Protection:>=2Kv , Mounting :-Recess , Driver Location :- External 20 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 21 Supplying And Laying 6 Swg G.I. Wire At 0.50 Metre Below Ground Level For Conductor Earth Electrode, Including Connection / Termination With Gi Thimble Etc. As Required. 22 Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nutbolt & Spring Washer Spaced At 50Mm ) 23 Fabrication, Supply , Installation , Testing And Commissioning Of Indoor Floor Mounted Type Feeder Panel With Following Specifications: Crca Sheet Of 1.6 Mm, Grey Color With 1000 A Bus Bar Incomer With Suitable Size Cable Alley Chamber For Incomer Cable , Suitable Size 1000 A Bus Bar Chamber And Suitable Size Cable Alley Channel For Outgoing, 4 Nos Outgoing With 1 No. 630 4P / 50 Ka Mccb & 3 Nos 400 4P / 50 Ka Mccb With Suitable Size Bus Bar.4 Nos Digital ( 3 Line Vaf+ Pf ) Meter On Outgoing Feeder With Suitable Size Cts And Other Accessories Complete With All Connection Etc. As Required. Drawing Should Be Approved By Engineering Incharge. 24 Fabrication, Supply , Installation , Testing And Commissioning Of Outdoor Stand Mounted Feeder Panel With Following Specifications : Crca Sheet Of 1.6 Mm, Grey Color With 400 A 36Ka / 3P Mccb 415 V Incomer With Neutral Bar , Suitable Size Bus Bar 3 Nos Outgoing 2 Nos 200 Amp 25Ka / 3P Mccb 415 V And 1Nos 100 Amp 25Ka / 3P Mccb 415 V With Suitable Size Bus Bar.1 Nos Digital ( 3 Line Vaf+ Pf ) Meter On Incomerwith Suitable Size Cts And Other Accessories Complete With All Connection Etc. As Required. Drawing Should Be Approved By Engineering Incharge. 25 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 3.5 X 400 Sq Mm ( 82 Mm ) 26 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 4 X 35 Sq Mm ( 32 Mm ) 27 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required.Above 185 Sq. M And Below 400 Sq Mm 28 Disconnecting The 4X3½x400 Sq. Mm Cable From Existing Panel Including Removing Gland Andlugs From Existing Panel And Cutting 4X3½x400 Sq.Mm Cable Andremoving Cable Approx.60 Meter From Existing Masonry Trench And Kept In Safe Place As Directed By Engineering Incharge. 29 Supplying Of 4 Core 35 Sq.Mm Copper Conductor, Xlpe Insulated , Pvc Tape Inner Sheathed , Armour ( Glavanised Wire ) 1100 V Grade As Per Is 7098 ( Part 1 ) 1988. 30 Supplying Of 3.5 Core 400 Sq.Mm Aluminum Conductor, Xlpe Insulated, Pvc Tape Inner Sheathed, Armour ( Glavanised Wire ) 1100 V Grade As Per Is 7098 ( Part 1 ) 1988. 31 Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With 25 / 32 A 240 V C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required.

Key Value

Document Fees
Refer document
EMD
INR 34213.0 /-
Tender Value
INR 17.10 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail