| 1 | Taking down old damaged SGSW/UPVC/RCC pipes from existing lines including necessary excavation as per requirement of old fitted in trenches & S&F 150 mm dia RCC NP3 pipe laid and jointed complete includingproviding 150 mm thick cement concrete (1:4:8) type D-2 using 40mm grade stone agg as in bed for pipes incl packing under and huaunching against the sides of pipes after they are laid tested complete all as specified and directed . |
| 2 | Taking down old damaged SGSW/UPVC/RCCpipes from existing lines including necessary excavation as per requirement of old fitted in trenches & S&F 200 mm dia RCC NP3 pipe laid and jointed complete includingproviding 150 mm thick cement concrete (1:4:8) type D-2 using 40mm grade stone agg as in bed for pipes incl packing under and huaunching against the sides of pipes after they are laid tested complete all as specified and directed . |
| 3 | Taking down old damaged SGSW pipes from existing lines including necessary excavation of old fitted in trenches & S&F UPVC underground drawings pipe (UDS) type \"B\"200mm dia with wall thickness 4mm (min) and pressured 4 KN /Mtr Sq jointed in cement solvent completeincluding providing cement concrete (1:4:8) type D-2 using 40mm grade stone agg as in bed for 200mm bore pipes incl packing under and huaunching against the sides of pipes after they are laid tested complete all as specified and directed . |
| 4 | All as per item srl No 03 above but 160 mm dia complete all as specified and directed . |
| 5 | Cutting into existing manholes for connecting new drains, making good to pipe and making good of broken manhole. |
| 6 | M&L Cleaning of existing sewage pipe lines 100mm/150/ 160/ 200mm internal dia,blockage of bathroom/toilet kitchen by cleaning the Nahani traps/gully traps,blockage of WC Indian or European washing thoroughly grating of trap,CI waste pipes by opening the clearing eyes,removing all the mud/sludge and getting out including cleaning of SGSW or CI or UPVC pipes upto first manhole, Cleaning of CI pipes of any dia from first floor to ground floor upto trap and Ist manhole along the wall, floor, at any depth inciuding manholes by removing the manhole covers of any type / size and cleaning by manually asrequierd at site from manholes and well flushing with water after cleaning including getting out sludge if any and liquid materals from connecting manholesdeposited in sewar line removing the solids and sludge to anydistanceand reinstatingthe manhole cover to its oiginal postion (cost of removal of sludge/liquid material from sewage lines and manholes in same line is incl. in rate of this item and rate quoted also includes for keeping particular sewage line which is undertaken once for cleaning, functional for full contract period) complete all as specified and directed by Engr-in-ChargeNote:- (a) Contractor/supervisor take complaint from JE concernedall day and ensure to resolve all complain. with in same day. (b) Contractor shall make himself aquainted with the area & the complain received daily in general.No claim however shall be entertained in regard to any incorrect assesment or increase in complains due to unforescen reason.(c) All complains need to be cleared with in same day only. (d) No payment shall be made for Sundays & holidays. However department shall not give major work on these days and only major work requiringfull day job of one mazdoor is required than department shall allow leave on another dy in compensation. No extra claim,however,shall be entertained in this regard. |
| 7 | (e)Contractor will deploy sufficent mazdoor(skilled or unskilled) daily to attendday to day complaint as mentioned above.The details of the mazdoor shall be submitted by the contractor to GE through Engineer-in-Charge.Insurance of mazdoor within 15 days commencement of work along with insurance from Govt Agency.Mazdoor will reportdailyor as required to Supervisor who will distribute complain after takingJE incharge from Subdivisonat 0900 hrs and departafterattending all complaints. Incase of non attending complaints in same day ,recovery @250 per complaints will be recovered from contractor.(f) The contractor shall provide adequate tools,plants,clothing kit etc to rectify the complaints.(g) The sludge obtained during rectifying the complaints shall be deposited & dispose suitably all as specified and directed . |
| 8 | M&L Cleaning of existingseptic tank/soakage well/ manholes/ lines and de-sluding /de-watering of septic tank and soakage well of any size and depth by removing the manhole covers of any type / size and cleaning by means of hydraulic jet pressure/pumping machine asrequierd makingit fully functionalto the entire satisfaction of Engr -In- Charge at site, from manholes and well flushing with water after cleaning including getting out sludge if any and liquid materals from connecting manholesdeposited in sewar line removing the solids and sludge to anydistanceand reinstatingthe manhole cover to its oiginal postion (cost of removal of sludge/liquid material from sewage lines and manholes in same line is incl. in rate of this item and rate quoted also includes for keeping particular sewage line septic tank and soakage well which is undertaken once for cleaning, functional for full contract period) complete all as specified and directed .Note:- (a) The contractorshall bailout entire blocked sewage in septic tank,soakage well,line etc and all as directed by Engr-in-Charge. (b) Contractor shall make himself aquainted with the area & the complain received daily in general.No claim however shall be entertained in regard to any incorrect assesment or increase in complains due to unforescen reason.(c) Contractor will deploy sufficent mazdoor(skilled or unskilled)to attend complaint as mentioned above. Incase of non attending complaints sufficent time as decided by Engr-in-Charge but not more than 3day ,recovery @ 1000 per day will be recovered from contractor. (d) The contractor shall provide adequate tools,pressure pump for cleaning blocked lines and pumping bailing out machine & storage tank for sludge.(e)The sludge obtained during rectifying the complaints shall be deposited & dispose suitably all as specified and directed. |
| 9 | Disconnecting existing tanks, setting side for repairing cleaning and removing all scale and dirt etc. from tanks and from mouths circulating pipes and hoisting in same position of capacity upto and including 500 ltr and endorsed the word \"CLEANED ON WITH DATE with white paint including replacement of broken/unserviceable fitting such as Elbow Tee, socket, nipple of any size complete all as specified & directed |
| 10 | Disconnecting existing tanks, setting side for repairing cleaning and removing all scale and dirt etc. from tanks and from mouths circulating pipes and hoisting in same position of capacity exc 500 ltr but not exc 1000 ltr and endorsed the word \"CLEANED ON WITH DATE with white paint including replacement of broken/unserviceable fitting such as Elbow Tee, socket, nipple of any size complete all as specified & directed |
| 11 | Dismantling water tanks (capacity of tank exc. 250 ltr but n. exc. 500 ltr) and removing from site ,S&F Rotational moulded polyethelyne water storage tank three layered (cylindrical vertical with closed top hoisted fixed in position all as specified in SSR part-I, capacity of tank 500 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively 20mm GI pipe medium grade over flow pipe 15cm long and brass valve 20mm high pressure with polyethelyne float and fly nuts complete all as specified and directed. |
| 12 | Dismantling water tanks (capacity of tank exc. 500 ltr but n. exc. 1000 ltr) and removing from site,S&F Rotational moulded polyethelyne water storage tank three layered(cylindrical vertical with closed top hoisted fixed in position all as specified in SSR part-I, capacity of tank 1000 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively 20mm GI pipe medium grade over flow pipe 15cm long and brass valve 20mm high pressure with polyethelyne float and fly nuts complete all as specified and directed. |
| 13 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 14 | M&L for brick work in cement mortar 1:4 of old size sub class ‘B\" bricks straight or curved on plan exceeding 6mtr mean radius complete all as specified and directed. |
| 15 | All as per description of item 15 above but except bricks complete all as specified and directed |
| 16 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wallsbuilt in cement mortar 1:4 complete all as specified and directed. |
| 17 | Demolition of cement concrete unreinforced of any description in any position not otherwise specifically provided for complete all as specified and directed |
| 18 | M&L for PCC (1:3:6) type C-2 using 20mm graded crushed stone aggregate as surface channels and drain etc including necessary form work complete all as specified and directed. |
| 19 | M&L for PCC 1:4:8 type D-2 (using 40mm broken graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 20 | M&L for PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in coping PCC, block for hold fast including all necessary from work complete all as specified and directed. |
| 21 | S&F Doctor fixit Pidifin 2k high performance 2 component flexible Acrylic polymer modify cement base water proofing coating in two coat 1mm thick dry film mixed in ratio 2:1 by weight or 1.5:1 by volume product of M/S Pidilite Industry Limited Makers of Fevicol adhesive brand over 10mm thick rendering in cement mortar 1:4 mixed with liquid water proofing admixture of approved brand complete all as specifed & directed. |
| 22 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, complete all as specified and directed. |
| 23 | Providing precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs and similar articles including necessary moulds/formwork set in cement mortar (1:6) complete all as specifed and directed. |
| 24 | M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 25 | M&L for Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 26 | M&L for15mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and directed.complete all as specified and directed |
| 27 | Taking up or down GI pipes 20mm bore and connection including cleaning for refixing or removal un-serviceable pipe, S&F GI tube 20mm bore medium grade galvanized with all fitting and fixed to short length complete all as specified and directed. |
| 28 | Taking up or down GI pipe 15mm bore and connections, including cleaning for refixing or removal unserviceable pipe, S&F 15mm bore GI tubing medium grade galvanized ISI marked with all fittings complete on walls complete all as specified and directed. |
| 29 | S&F in repairs vitreous china wash down water closet (pedestal pattern) white including fixing bolts and connecting to drain pipe, including seat cover plastic flat bottom and MS Chromium plated hinging device and connection to flush pipe, anti syphonic pipe etc complete all as specified and directed. |
| 30 | S&F in repair vetreous China squatting pan Orissa pattern size 580 x 440mm white with integral foot rest ( excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anty syphonage pipe etc. and including 110mm bore PVC \"P\" or \"S\" trap complete incl making good to floor complete all as specifed and directed. |
| 31 | S&F in repair vitreous china wash hand basin (flate back or angle back type)colouredof bowl size 550mmx400mm including waste and waste pipe PVC 32mm dia to be fixed over marble slabs or iron brackets complete all as specified and directed. |
| 32 | S&F in repairs 10 litres PVC low level flushing cistern syphonic action type with inlet ball valve float and push type handle including bracket, PVC 32mm diaflush pipe with coupling and fixed complete all as specified and directed. |
| 33 | S&F PVC connection 15mm bore size with two nuts and washers of length 450mm complete all as specified and directed. |
| 34 | S&F grating round 140mm size of PTMT (minium weight 50gms) as in repair, complete all as specified and directed. |
| 35 | Dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises ,M&LCeramic colouerd tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,in floors etc.set and jointed in neat cement slurry with and pointed in coloured cement match the colour of tiles over 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed. |
| 36 | Dismantling ofwall tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises,M&L for providing glazed ceramic colouredwall tiles of exterior quality of size 450mmx350mmx7mm thick, set, jointed in colour cement to match laid over and including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 37 | Dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises,M&L Non skid ceramic colour tiles 7 to 8 mm thick ( sq/ rect) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, infloor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 38 | S&F in repair 32mm bore corrugated PVC waste pipe, complete all as specified and directed. |
| 39 | S&F in replacement 75mm bore PVC floor trap with grating including jointing to waste pipe in cement concrete type B-1, 1:2:4, complete all as specified and directed. |
| 40 | Dismantling/taking down of cast iron or unreinforced concrete or PVC soil waste and drain pipe 75mm or 100mm dia with all fittings complete all as specified and directed. |
| 41 | S&F, 110mm bore, PVC rainwater (SWR) drainage pipes single socketed, in any length with rubber ring joints as in repair, fixed to walls with sufficent number of Iron stack clamp complete all as specified and directed. |
| 42 | S&F for 110mm bore pipes,PVC (SWR) bends any radius fitting fo PVC (SWR) pipes as in repair complete all as specified and directed. |
| 43 | S&F of 75mm PVC (SWR) drain pipes 75 mm bore single socketed in any length with rubber ring joint fixed to walls complete all as specified and as directed. |
| 44 | S&F for 75mm bore pipes,PVC (SWR) bends any radius fitting fo PVC (SWR) pipes as in repair complete all as specified and directed. |
| 45 | Demolition of stone slabs, paver blocks and tiles of any description or thickness in floors/apron laid dry complete all as specified and directed. |
| 46 | S&F machine pressed precast concrete interlocking paver blocks with grey cement and no pigment, any shape and size conforming to IS 15658:2006 of 60 mm thickness M35 grade complete all as specified and directed. |
| 47 | M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 48 | Demolition of cement Concrete(unreinforced)in ground floors and pavings n exc 15 cm thickness (below or above ground level ) complete all as specified and directed |
| 49 | M&L for Cement concrete in foundations, filling and mass concrete typeB-2, 1:4:8 using 40mm graded stone aggregate as in sub base of tiles/blocks complete. |
| 50 | Chequered cement concrete tiles 300mm x 300 mm x 25 mm thick tableset and jointed, pointed in neat cement slurry with grey cement and no pigment as in floor,Screed bed or bedding layer of 20 mm thick CM (1:6) as in floor, complete all as specified and directed. |
| 51 | M&L for hard core of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surfaces complete. |
| 52 | S&F glass deviding strip 3mm thick and 38 mm wide fixed to design complete all as specified and directed. |
| 53 | Taking down cement plaster on brick or concrete surfacesany description including raking out joints hacking for key scrubbing down with water, M&L for15mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cementcomplete all as specified and directed.complete all as specified and directed |
| 54 | Preparation of new plastered surfaces of walls and applying two coats of cement base paint including preparation etc complete all as specified & directed. |
| 55 | M&L for 100mm thick plain cement concrete1:2:4 type B-1 ( using 20mm crushed stone agg ) as in floors ,ramps,hard standing or asin similar workfinished even and smooth without using extra cement including form work where required all as specifed and directed . |
| 56 | M&L 50mm thick PCC, type B-1, 1:2:4, ( using 20mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without nusing extra cement complete all as specified and directed. |
| 57 | M&L Providing precast cement concrete 1:2:4 type B-0 using 12.5mm graded aggregates louvres and jallies, 40mm thick (measured solid), including all mouldings but excluding frame, set in CM 1:4.complete all as specifed and directed. |
| 58 | M & L Providing precast cement concrete Type B-1 1:2:4 in window or door ,cills,lintels,bressumers ,steps,quoin block(for use with masonry) string courses, copings, kneelers,apex stones, pier caps, columns, posts, boundry pillars,bed plates,pikntle block, anchorage blocks, bonders (for stone walling),corbels,brackets etc(of any section indicated) with plain fair faces,including chamfers weathering throating etc and setting in mortar complete with joints to match complete all as specified |
| 59 | M&L for PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregates aggregate, as in foundation filling and mass concrete all as specified & directed. |
| 60 | Dismantling RCC posts and struts any section including taking out embedded portion in natural ground and making good disturbed surface. |
| 61 | S&F for Mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde-E-165 complete all as specified & directed. |
| 62 | S & F in repair Galvanised, (hot dip) 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed (each line wire to be measured) |
| 63 | Preparation of new steel surfaces of any description not otherwise described, over 10 cm width or girth and providing two coats of synthetic enamel paint over a coat of red oxide primer all as specified & directed. |
| 64 | S&F Chain link MS galvanised fencing of wire mesh size 50 mm x 50 x 3.8 mm all as specified |
| 65 | Fixing only chain link fencing in cl line wires any mesh, size and type to any type of standards, rails, straining bolts, etc incl provn of binding wire. |
| 66 | S&F MS round bar 10 mm dia as in strands for holding chain link fencing incl hooking etc complete all as specified and directed. |
| 67 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, 5 to 10 mm diameter of shank, complete all as specified and directed. |
| 68 | M&L for Concetrina coil securing or tying incl provn of MS wire stapples or steel pins etc all as specified & directed. |
| 69 | Restraining rescuring of incl making good staples the old galvanised steel barbed wire any dia incl securing or tying at crossings as directed |
| 70 | Dismantling wrought iron or mild steel work of any description. |
| 71 | M&L for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240. |
| 72 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings |
| 73 | M&L Prepainted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength 550 Mpa as in roof covering/cladding to walls, fixed with selg taping screws as specified. |
| 74 | M&L pre painted galvalume aluminum zinc coated GI based plain steel sheeting 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws as specified. |
| 75 | Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account. |