| 1 | Taking down carefully aluminium/copper wiring/power pont wiring (light, fan, call bell, socket or power circuits) complete and making good the disturbed surfaces of walls,ceiling etcincl painting with same colour of the back ground complete all as specified and as directed by engr-in-charge. |
| 2 | Material and labour for point wiring forOne light point with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, ISI marked, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, ISI marked, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and as directed by engr-in-charge. . |
| 3 | (a) All as per serial item No. 2 here-inbefore but for socket outlet 3 pin, 5 Amps on indepedent boardcomplete all as specified and as directed by engr-in-charge. |
| 4 | (b) All as per serial item No. 2 here-inbefore but for socket outlet 3 pin, 5 Amps on same boardcomplete all as specified and as directed by engr-in-charge. |
| 5 | (c) All as per serial item No. 2 here-inbefore but for for fan point controlled byone 5/6 amp switch one way complete all as specified and as directed by engr-in-charge. |
| 6 | (d)All as per serial item No. 2 here-inbefore but for for bell point controlled byone bellpush 5/6amp one way complete all as specified and as directed by engr-in-charge. |
| 7 | All as per item No. 2 above but with 2.5 sq mm wire for one 15 Amps socket outlet on independent board with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly, complete all as specified and as directed by engr-in-charge. |
| 8 | Supply & fixing in repair ofLEDtube rod of capacity 20 watt single side, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 9 | Supply & fixing in repair of 22 watt single side LED light fitting fixture with extruded AL heat sink, environmental friendly, ready to use, suitable for 4 ft led tube, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 10 | Supply & fixing switch piano, flush type, 5 amps, single pole, one way, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 11 | Supply & fixing in repair of switch piano, flush type, 5 amps, single pole, one way, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 12 | Supply & fixing socket outlet, flush type, 5 amps, single pole, 5 pin, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 13 | Supply & fixing in repair socket outlet, flush type, 5 amps, single pole, 5 pin, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 14 | Supply & fixing ceiling rose three terminal surface bakelite 65X20mm size complete all as specified and as directed by engr-in-charge. |
| 15 | Supply & fixing Switch socket Combination 2 in 1, 5 Amps flush type, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 16 | Supply & fixing in repair of Switch socket Combination 2 in 1, 5 Amps flush type, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 17 | Supply & fixing switch Socket combination 2 in 1, 6 pin 5 Amps and 15 Amps controlled by one switch, 230 volts AC, complete all as specified and directed. |
| 18 | Supply & fixing in repair switch Socket combination 2 in 1, 6 pin 5 Amps and 15 Amps controlled by one switch, 230 volts AC, complete all as specified and directed. |
| 19 | Supply & fixing in repair of switch piano, flush type, 15 amps, single pole, one way, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 20 | Supply & fixing in repair of Socket outlet 2 in 1, 6 pin, 5 and 15 Amps, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 21 | Supply & fixing bell push, 5 amps, single pole, one way, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 22 | Supply & fixing in repair of bell push, 5 amps, single pole, one way, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 23 | Supply & fixing of call bell, Ding dong type, 230 volts AC single pole, complete all as specified and as directed by engr-in-charge. |
| 24 | Supply & fixing in repair of call bell, Ding dong type, 230 volts AC single pole complete all as specified and as directed by engr-in-charge. |
| 25 | Supply & fixing ceiling fan regulator electronic type, five step, humming free, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 26 | Supply & fixing in repair ceiling fan regulator electronic type, five step, humming free, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 27 | Taking downold unserviceable main switch/DBs/MCB DBs with MCB including making good the disturbed area complete all as specified and as directed by engr-in-charge. |
| 28 | S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used, triple pole and neutral, 4 ways, 415 volts with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plates, including fixing DB flush in wall complete with making good disturbed surfaces and colour matching, complete all as specified and as directed. |
| 29 | S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used, single pole and neutral, 8 ways, 220 volts with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces and colour matching, complete all as specified and as directed. |
| 30 | S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used, single pole and neutral, 4 ways, 220 volts with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces and colour matching, incl taking down old one, complete all as specified and as directed. |
| 31 | S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used, single pole and neutral, 2 ways, 220 volts with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces and colour matching, incl taking down old one, complete all as specified and as directed. |
| 32 | Supply and fix in repair of of MCB, DP, AC, 240 volt of 63 Amp capacity, \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs, complete all as specified and as directed by engr-in-charge. |
| 33 | Supply and fix in repair of of MCB, DP, AC, 240 volt of 40 Amp capacity, \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and as directed by engr-in-charge. |
| 34 | Supply and fix in replacement of MCB, SP, AC 240 volt of 6 to 40 Amp capacity, \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and as directed by engr-in-charge. |
| 35 | Supply and fix in replacement of MCB, TPN, AC 415 volt of 32 Amps capacity, \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and as directed by engr-in-charge. |
| 36 | Supply and fix in replacement of MCB, TPN, AC 415 volt of 63 Amps capacity, \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and as directed by engr-in-charge. |
| 37 | S & F in replacement of LEDbldg security Lightfitting complete60 Watt, 5700K, with high powerenergy saving pressure die cast aluminium IP 66 roadway luminiares, heat resistant toughened glass with frame, better optics for uniform distributionwith high power LED as Ligh source with the MS clamp made of 25X3 mm flat iron with bracket of GI pipe medium grade 25mm dia and not less than 1.2 mtr end of GI pipe suitable for street light including taking out old unserviceable one complete all as specified and as directed. |
| 38 | Taking down old/unserviceablesub main wiring of any sizes including batten/conduit complete all as specified and as directed by engr-in-charge. |
| 39 | Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS stranded copper conductor cable with and including continuous earth wire of size 4.0 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS stranded copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade, ISI marked complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing surface complete all as specified and as directed by engr-in-charge. |
| 40 | All as per item No 35 above but size of sub main wiring 6 sqmm with 6 sqmm earthing cable, complete all as specified and directed. |
| 41 | Supply & fixing in repair of decorative box type fittings with end cap for LED tube 22 watt luminiare for 230 volts AC including LED tube 22 watt complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 42 | Supply & fixing in repair of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by engr-in-charge. |
| 43 | Supply & fixing in repair/replacement plug top 15A, 240 volts, complete all as specified and as directed by engr-in-charge. |
| 44 | Supply & fixing in repair/replacement plug top 5A, 240 volts complete all as specified and as directed by engr-in-charge. |
| 45 | Supply & fixing in repair LED 15 watt retrofit bulb with holder base B-22 with polycarbonate body and aluminum heat sink BEE 5 STAR rated, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 46 | Supply & fixing in repair/replacement LED 20 watt retrofit bulb with holder base B-22 with polycarbonate body and aluminum heat sink BEE 5 STAR rated, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 47 | Supply & fixingin repair of LED 10 watt retrofit lamp with holder base B-22 with polycarbonate body and aluminium heat sink, BEE 5 STAR rated, 230 volts AC, complete all as specified and as directed by engr-in-charge. |
| 48 | Supply & fixing in repair of Decorative, wall mounting, SS finish fixture with opal glass diffuser suitable for and including 8 watt retrofit led lamp, complete all as specified and directed. |
| 49 | Supply & fixing in repair of LED ceiling light (2x2) of 40 watt, premium white powder coated frame blends seamlessly with ceiling layout suitbale for 600x600 mm modular ceiling grid, complete all as specified and directed by engr-in-charge. |
| 50 | Taking down carefully UNSV ceiling fan/Exhaust fan/cabin fan of any sweep and any make from the site after disconnecting from ceiling rose for carrying out necessary rewinding and writing MES No. with black synthetic enamel paint and refixing the same complete all as specified and as directed by engr-in-charge. (Cost of rewinding is not included under this item). |
| 51 | M & L for rewinding of ceiling/exhaust/wall mounted/cabin/table fan with super enameled copper winding wire of same size/gauge as per existing one and also including replacement of wornout nut, bolt, washers, split pin etc., re assembling and testing on completion complete all as specified and directed for the following type of fans.(a) Ceiling fan of any Make 1200 mm to 1400 mm sweep |
| 52 | (b) Exhaust fan of any Make 300mm to 380mm sweep. |
| 53 | (c) Cabin fan/wall fan/table fan/pedestal fan 400 mm sweep. |
| 54 | Supply & fixing in repair of following components of fan in replacement of unserviceable parts, complete all as specified and as directed by engr-in-charge.(a) Ball bearing of suitable size for ceiling fan/Exhaust fan of any size and sweep. |
| 55 | (b) Rubber reel with nut bolt and washers for hanging of ceiling fan any size. |
| 56 | (c) MS Clamps with nut bolts and washers for hanging of ceiling fan of any size. |
| 57 | S&F fixing in repair of sheet metal enclosure single pole & neutral with a two pin and earth plug and socket with one single pole MCB 20 amp 240 volts, complete all as specified and as directed by engr-in-charge. |
| 58 | S & F air termination, single pointed copper rod 12 mm dia and 300 mm long discharge capacity 65 KA, including insulators, stay, PCC all necessary earth works required for site, complete all as specified and as directed by engr-in-charge. |
| 59 | S&F 25 mm dia GI tubing with all fittings, light grade for protection of strip passing across the road, wall under floor etc complete all as specified and as directed by engr-in-charge. |
| 60 | Repair/replacementfor brazing of earth continuity conductor or main earthing lead 25mm X 3mm, aluminum strip/earth lead, in any position including jointing by existing tinned copper/brass nuts, bolts and washerscomplete all as specified and as directed by engr-in-charge.Note:-(i) Each joint shall be considered for measurement purpose.(ii) Existing nut bolts & washers shall be reused for jointing of strips.(iii) Brazing shall be done with gas welding using brass electrode. |
| 61 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron strip 32X6mm, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle completeall as specified & directed by Engineer-in-Charge. NOTE: Earth lead wire and its protection pipe upto and including 15 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ |
| 62 | Ditto but using copper plate 60X60cmX3.15mm thick electrode and 20X3 mm copper strip as earthing lead, complete all as specified and directed. |
| 63 | Supplyand fixing Tripod Earthing (3 Set earthing inter connected to 1 set) maintenance free Earthing Solutions comprising with the following: -- Supply and fixing after digging bore of suitable size the CPRI tested and UL certified maintenance free earthing system having a set of copper bonded Earth Rod of 3 meter length, 17.2 mm dia made of high tensile low steel circular rods, molecularly bonded with 99.90% electrolytic grade copper on outer surface (minimum copper bonding thickness - 250 microns) with exothermally jointed copper bus bar of 200X25X6mm for long lasting and connection. Earth Copper bonded rod & exothermically jointed bus bar should be CPRI tested on 25KA fault current complete all as specified and directed by engg-in-charge for complete connections. - Qty 3 Nos.- Earth Copper bonded Electrode should be tested by CPRI- Current carrying capacity of Earth Copper bonded Electrode is 25KA/Sec. |
| 64 | Item 55.00 Contd.....- Supply and filling of carbon based, eco friendly earth enhancing compound of RHOS tested compound tested by NABL accredited Lab in compliance to IEC 62561-7 and having passed leaching, sulphur, corrosion resistivity test as per IEC 62561-7 an international standard for earth enhancement compound in compliance to IEC 62561-7 with a resistivity < 0.12 ohm-m, 25 kg, Qty- 3 Nos.- Earth enhancing compound shall be free from corrosion, it shall be carbon based material and shall be free from bentonite and other hazardous substances. The product does not dissolve, deteriorate or leach out of time. It shall be highly conductive and improves earth\"s absorbing power and humidity retention capability, It shall be eco-friendly and chemically inert to sub soil.- Supply and fixing plastic Earth pit Cover of size 247mm x 338mm x 210mm having load bearing capacity of 8 Ton and complying IEC 62561-5. Qty - 3 Nos.Note - On testing after completion of job, if desired earth resistence is not found i.e. below 1.00Ohms, the earthing shall be redone at no extra cost to the Govt.Make: JMV LPS Limited/Ennov/Advance Earthing Solutions (AEs) |
| 65 | M&L in repair 20X3 MM copper strip as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required, complete all as specified and as directed by engr-in-charge. |
| 66 | M&L in repair 4mm dia galvanised iron wire as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required, complete all as specified and as directed by engr-in-charge. |
| 67 | Supply and fixing in repair single phase Static Energy Meters, ISIMarked, Digital Energy meter for net metering with enclosure having capacity 5-30Amp, 240V, Accuracy Class 1.0, DLMS Compliant, Optical Port and Load survey including suitable SMCMeter Box, sealing arrangement along with 2 Nos. polycarbonate meter seal and making connection, complete all as specified and as directed. |
| 68 | All as per item No 67 but three phase, 415 V, electronic type meter, complete all as specified and directed. |
| 69 | Supply and fixing in repair of decorative wall mounting type SS finish fixture with opal glass diffuser suitable for 15 W LED bulb, 230 Volt lamp holder, 15 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed. |
| 70 | S & F post top lantern LED type 40 watt, 230 V AC, outdoor with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driverand lamp complete.Cat Ref - LPTO-40-CDL/M incl taking down old unsv complete all as directed. |
| 71 | Supply & fixing in repair of condenser 2.5 MFD suitable for any type of fan, complete all as specified and directed.Make:- Epcos/Havells/Usha |
| 72 | Supply & fixing in repair of condenser 4 MFD suitable for any type of fan, complete all as specified and directed.Make:- Epcos/Havells/Usha |
| 73 | Supply & fixing in repair of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and as directed by engr-in-charge. |
| 74 | M & L for fixing, tesing and commissioning in repair of submersible pump of desert cooler, single phase 18watt230 volt 50 HZ as per existing size & specification including taking out the old one all as specified and directed.Make:- Crompton Greaves/BAJAJ/USHA/KHAITAN |
| 75 | Material and labour for disconnecting electric connection, taking down/ keeping aside the air conditioner (Split/Window) and Water Cooler including stabilizer of any make and capacity, Servicing the same as cleaning inside by means of cleaning of filter, removing dust from body, tightening of loose nut, bolt, washer, rubber gasket and tightening of loose wiring, loose connection, replacement of wornout nut, bolt, washers, gasket etc and necessary cutting, welding/soldering works with replacement of rusted body parts with new MS/GI Sheets of suitable size and making the equipment fully functional and Re-installation in position and testing, complete all as specified and directed by Engineer-in-charge. Note: (All new spare parts will be measured and paid separately under the appropriateitems as supply only). |
| 76 | Labour only for collecting split /window AC of 1.5/2.0 TR cooling capacity of any make/model from E/M store yard and installation of indoor and outdoor unit wherever as directed, making/breaking hole through the wall for passing the suction/discharge line and PVC coduit of 15mm dia n. exc. 2.5mtr long in concealed surface of wall for drainage of water occurs due to humidity, making good to disturbed surfaces with cement mortor of ratio1:3 finishing to match and testing, complete all as specified and directed. |
| 77 | Material and labour for detection and rectification of leakages in gas line by necessary brazing in 1.5 Ton/2.0 Ton window/split type AC of any model and any make and ensuring the complete systems leak proof including checking the system and replacement of required spare parts including charging of refrigerant gas R-134/R-134A/22/32/410A with appropriate quantity including testing for smooth functioning all as specified and directed. Note: Spare parts, if requited will be measured and paid separately under the supply of appropriateitems. |
| 78 | Material and labour for dismantling of unserviceable/worn hermetically sealed unit compressor from window/Split type AC and replacement with new compressor suitable for existing same model/make of capacity 1.5 TR split/window type AC including brazing with suction and discharge line, checking the system for leak proof and inclduingcharging of refrigerant gas R-134/R-134A/22/32/410A in appropriate qty after making vaccume the complete system and testing the AC for proper functioning all as directed. |
| 79 | Allas per item No-69 here in before but of capacity 2.0 TR split type AC, complete all as specified and directed. |
| 80 | Supply and fixing the following spares parts required for repairs for window/split type AC or water coolers of any capacity against item No 67.00 here in above complete all as specified and directed by Engineer-in-Charge: -Note: All the repairs shall be carried out at AGE E/M store yard including transportation of equipment and re-fixing at site. Make of spare parts shall be as of OEM: -Supply only Cooling coil complete with fins made of copper suitable upto 2Ton/1.5 Ton capacity Window/Splittype AC.as per existing size and specification |
| 81 | Supply only Condensing coil complete with fins made of copper suitable for upto 2Ton/1.5 Ton capacity Window/Splittype AC as per existing size and specification, complete all as specified and directed. |
| 82 | Supply only fan motor for water cooler upto 120Ltr capacity, complete all as specified and directed. |
| 83 | Supply only fan blade suitable for AC\"s blower/ water cooler motor and all as per sample, complete all as specified and directed. |
| 84 | Supply only Condensing coil suitable for water cooler upto 120 Ltr capacity copper made, complete all as specified and directed. |
| 85 | Supply only Cooling coil suitable for water cooler upto 120 Ltr capacity copper made. |