| 1 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in softloose soil for laying / taking up/ taking down of cablesand getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge. |
| 2 | Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. |
| 3 | Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge. |
| 4 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified. |
| 5 | S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge. |
| 6 | All as per srl item No 5 here-in-before but using old bricks obtained under srl item No1 here in before. |
| 7 | Supplying, laying, jointing testing and connecting in replacement of underground cables, XLPE insulated, screened, PVCbedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) with multistranded aluminum conductors,IS 7098marked, suitable for LT 1100 Voltsystem, laid in trenchesfixed to pole, including jointing & testing complete all as specified and directed of following sizes:-Note :-Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule. |
| 8 | 16 Sqmm 4 core |
| 9 | 25 Sqmm 3.5 core |
| 10 | 35 Sq mm 3.5 core. |
| 11 | 50 Sq mm 3.5 core. |
| 12 | 70 Sqmm 3.5 core |
| 13 | 95 Sqmm 3.5 core |
| 14 | 120 Sqmm 3.5 core |
| 15 | 185 Sqmm 3.5 core |
| 16 | 240 Sqmm 3.5 core |
| 17 | Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends all specified and directed |
| 18 | S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes |
| 19 | 100mm |
| 20 | 80 mm . |
| 21 | 50 mm . |
| 22 | 40 mm . |
| 23 | Taking outfaulty underground1100 Volt LT cable of differentsizes by excavation and removingbricksof any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using newbricks as required. Note: (a) 1100Volt LTcable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable brickswill be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs.(c) Excavation and earth work will be measured and paid for seperately under respective items of schedule. |
| 24 | Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :- |
| 25 | 25-50 Sqmm x 3.5 core/ 4 core |
| 26 | 70-150 Sqmm x 3.5 core |
| 27 | 185 -240 Sqmm x 3.5 core |
| 28 | Suplying and laying as replacement in sub station fixing 3.3 to 11 KV electrical insulation mat of size 5 mtr x 1 mtr x 2.5 mm thick specification as per IS 15652 2006 |
| 29 | Taking down unservicable RCC/ steel tubular poles of any type and supply & installingsteel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II), complete with cast iron/MS plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screw etc including excavation, earth work, PCC foundation,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer\"s instructions and as specified and as directed by E-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings along with clamps. The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed. |
| 30 | S&F KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps and 6 Amps MCB with base including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body with MS clamp of suitable sizehaving suitable size nut,bolts & washer complete all as specified and directed. |
| 31 | Material and labour disconnecting faulty /burnt end or portion of cable byremoving the cable from loop including necessary excavation & earth work , suitable size of thimble LT tape , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm3.5 core of LT cable toLT Panel/pole/main switch complete all as directed. |
| 32 | M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed. |
| 33 | Material and labour in replacement Retro Reflective installation sign boards of size 12 feet x 4 feet fabricated out of 16 gauge MS sheet frame duly welded/riveted with MS square pipe of size 25mm x25mm at height 9.00 meter above ground level on stainless steel heavy dutypipe of size 80mmbore embaded 75 CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx75cm including necessary excavation and earth work.The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape.The wiriting matter will be in English language on both sides with reflective adhesive painter tapesas directed by Engineer -in-charge. |
| 34 | Supplying and installation in replacement factory made and tested (including CPRI type tested certified panel) TimerPanel board ,cubical , out door type , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZAC supply system . The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and minimum32x32x5mm thick MS angle iron frame work,powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, frontopening type,closing locking arrangement including power wiring with 10 Sqmm PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts gradeand internal wiringwith 1.5 Sqmm copper conductorand comprising of the following:-(i)MCCB 3 pole , 32Amps,50 Hz,415 Volts, 16 KA, with thermal magneticrelease - 01 Nos (ii) 3 Pole power contractor, type MNX 110 having 2 NO +2 NC contacts -01 ( iii)Analog Time switch , 240 Volt AC , 50 Hz-01 No(iv) Auto /manual selector switch -10 No(v) Aluminium bus bar 100 Amps, 4 strip 3 phase and neutral 415 volts, 50 Hz, duly insulated with heat shrinkable PVC sleeves- 01 SetPlatform for the timer panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class \"B\", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. |
| 35 | Taking down unservicable RCC/ steel tubular poles of any type and supply & installing octagonal street light poles of 9 mtr height with 150mm bottom dia and 75mm top dia made up of 3mm thickalongwith galvanised base plate of size 225mmx225mmx16mm suitable to with stand maximum wind speed of 169 Km/hr and for mounting , decorative double/single over hand bracket for street light fittings .The internal & external surface of pole shall be dip galvanised 65 microns (minimum) DFT complete all as specified and directed. NOTE:- The unit rate in this item is deemed to be included the cost dismantling of old one pole , exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as inpole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . |
| 36 | Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT Panel board, cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZAC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work,powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size ( but not less than 2.5 Sqmm)and comprising of the following:- (a) Incoming :- (i)on load change over switch open execution of capacity 630 Amps, 4 pole, 415 volt, 50Hz- 01 Nos (ii)MCCB 4 pole , 630 Amps,50 Hz,415 Volts, 50 KA, with microprocessor release - 01 Nos(iii) Voltmeter digital typewith 4 way rotary selector swicth -01No (iv)Ammeter digital type with 4 way rotary selector switch-01No (v)CTsratio 600/5 A ,class 1, ISI marked -01 sets of three (vi) Indicating lamp- 01 set of three(vii)Aluminium bus bar of rating 1200 Amps- set of four (b) Outgoing(i) MCCB 4 pole ,160 Amps,50 Hz,415 Volts,25 KA with thermal magnetic release- 07Nos(ii) MCCB 4 pole , 125 Amps,50 Hz,415 Volts, 16 KA with thermal & magnetic release-01 Nos(c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class \"B\", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. Note :-(i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCBwithadjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer |
| 37 | All as in item No 20here-in-before but comprising of the following:- (a) Incoming :-(i)MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 35 KA, with microprocessor release - 01 Nos(ii) Voltmeter digital typewith 4 way rotary selector swicth -01No (iii)Ammeter digital type with 4 way rotary selector switch-01No (iv)CTsratio 250/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three(vi)Aluminium bus bar of rating 800 Amps- set of four (b) Outgoing(i) MCCB 4 pole ,100Amps,50 Hz,415 Volts, 25KA with thermal magnetic release- 03Nos |
| 38 | All as in item No 20 here-in-before but comprising of the following:- (a) Incoming :-(i)MCCB 4 pole , 630 Amps,50 Hz,415 Volts, 50 KA, with microprocessor release - 01 Nos(ii) Voltmeter digital typewith 4 way rotary selector swicth -01No (iii)Ammeter digital type with 4 way rotary selector switch-01No (iv)CTsratio 600/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three(vi)Aluminium bus bar of rating 1200 Amps- set of four (b) Outgoing(i) MCCB 4 pole ,400Amps,50 Hz,415 Volts, 35KA with thermal magnetic release- 04Nos |
| 39 | Supplying and fixing in replacement LED flood light fitting of following size complete all as specified and directed by Engr-in-charge :- |
| 40 | 90 Watt |
| 41 | 120 watt |
| 42 | 200 Watt |
| 43 | Supply and fixing in renewal of 3 pole power contactor ML-6 mounted on any type/description LT panel/feeder pillar/wallafter taking down old existing un serviceable contactor etc complete all as specified and directed. |
| 44 | Supply and fixing in renewal of 3 pole power contactor MNX-110 mounted on any type/description LT panel/feeder pillar/wallafter taking down old existing un serviceable contactor complete all as specified and directed. |
| 45 | Supply and fixing in renewal ofAnalog Time switch, 240 Volt AC , 50 Hz , mounted on any type/description LT panel/feeder pillar/wallafter taking down old existing un serviceable time switchcomplete all as specified and directed. |
| 46 | Supply and fixing in replacement of cable gland for LT panel/feeder pilar for 25 sqmm cable to 95 Sqmm cable complete all as specified and directed. |
| 47 | Supply and fixing in replacement of cable gland for LT panel for 120 sqmm cable to 300 Sqmm cable complete all as specified and directed. |
| 48 | Taking down unservicable RCC/ steel tubular poles of any type and supply & installingsteel tubular swan neck pole type 410 SP-31 (9 mtr long) complete with mild steel base plate, finial taper plug, bolts, nuts and screws including two coats of aluminium painting over a coat of primer for exposed surfaces and two coats of bituminous black paint over a coat of primer to the surfaces in contact with concrete inclusing two runs of PVC insulated 1100V multi-stranded copper wire of size 2.5 Sqmm from the junction box to the fitting complete all as specified and directed.Note :- The unit rate in this item is deemed to be included the cost oif exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total lenth inside and up to planting depth outside. |
| 49 | S&Fon load change over switch open executionof capacity630 Amps , 4 pole , 415 volt , 50 Hz mounted on wall with fastner and suitable size of nut and boltsafter taking down old existing un serviceable MCCB/SDFU etc complete all as specified and directed. |
| 50 | Supply & Fixing in replacementbracket for street light fitting complete with 1.5 to 2.2 mtr long 32/40mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete as as specified and directed. |
| 51 | Supply, drawing, connecting & testing of 3 core, 1.5 Sqmm PVC insulated and PVC rounded sheathed, copper conductor (flexible) industrial cable 1100 Volts grade conforming to IS-694 in steel tubular polefrom KIOSK box to light fittings including PVC conduit of size 20mm bore with clamping(Wherever required) andproviding suitablecopper lugs all as specified and directed.Note : Steel tubular pole shall be measured and paid separetely. |
| 52 | Supplying & fixing of LED street light Fitting 60 watt LED, IP-66 protection, single peice pressure die cast aluminiumhousing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartmentwith high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable along with GI pipe bracket for street light fitting complete with 2.2 mtr long 50mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete as as specified and directed. |
| 53 | S&F in replacement for Danger Notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white , with letters, figures and conventional skull and bobes in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20 cm size including taking down old one complete all as specified and directed. |
| 54 | Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5mbelow normal ground level, connected to galvanized iron strip 32mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electricalplate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed.Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc.(b)The quoted rates shall also deemed to include the cost of earth test point and earth strip/GIlead wire and protection pipe upto 7.5 meter beyond the earth plates electrode. |
| 55 | Supply and fixing in replacement of galvanised iron strip 32 X 6 mm for additional earthing lead beyond 7.5 meter complete all as specified and as directed.. |
| 56 | Supply and Installation ofLT CT operated Trivector Meter with the following specifications:-(a) Meter Type:LT 3 Phase 4 Wire Electronic Tri vector Meter(b) Standard: IS 13779:1999 / CBIP 88 (c) Accuracy: Class 0.5(d) Voltage and Current rating:-(i) Reference Voltage - 3x240 V (ii) Basic Current (Ib)- 5 A(iii) Maximum continuous current (Imax) - 10 A(e) Rated Frequency (variation) - 50Hz (±5%)(f) Power consumption:-(i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency(ii) Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature(g) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height(h) Display in the event of Power Failure: Internal battery back-up for LCD display(j)Communication port:(i) Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is provided (ii) RS 485 for DLMS protocol(iii) Energy recording - Unidirectional |
| 57 | S&F in replacement ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type , front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection |
| 58 | Supply installation & commissioning in replacement of12 Volts-100 AH sealed maintenance free battery in battery charger with suitable size of new copper battery terminal and lugs and initialy charging, commissioning and testing complete. |
| 59 | Supply only in replacement of old unserviceableBlower having volumetric flow rate 4 to 5 cum/min, 230 Volt , 50 Hz, complete all as specified and directed. |
| 60 | Supply and fix in replacement Digital Multifunction Transducer/Meter (Accuracy class 0.5) with LCD/LED display for measurement of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication of data on Modbus protocol including associated wiring using 1.5 Sqmm FRLS copper wire complete all as specified and directed. |
| 61 | Supply and fixing in replacement of Halogen light fittings including fitting of capacity 1000 Wattcomplete all as specified and directed. |
| 62 | Supply and fixing in replacement of Halogen lamp 1000 Watt for existing Halogen light fittings complete all as specified and directed. |
| 63 | S&Fin replacement of UNSV /Burnt MCCBs of capacity630 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with microprocessorrelease fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed. |
| 64 | S&Fin replacement of UNSV /Burnt MCCBs of capacity400 Amps, Four pole, 50 KA, 415 Volts 50 Hz, AC, with thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed. |
| 65 | All as per sr Item No 45 here in before e but rating of MCCB 250 Amp,FP, 36 KA. complete all as specified and directed. |
| 66 | As per sel item No 45 above but rating of MCCB 160 Amp,FP,25 KA. complete all as specified and directed. |
| 67 | All as per sr Item No 45 here in before e but rating of MCCB 100 Amp,FP,18 KA. complete all as specified and directed. |
| 68 | All as per sr Item No 45 here in before e but rating of MCCB 63 Amp,FP,10 KA. complete all as specified and directed. |
| 69 | Supply and fixMCCB 160Amp, 4 pole , 25 KA, 50 Hz with MCCBsheet metal enclosuremounted on wall with fastner and suitable size of nut and boltsafter taking down old existing un serviceable MCCB/SDFU complete all as specified and directed.. |
| 70 | Supply and fixMCCB 100Amp, 4 pole , 16 KA, 50 Hz with MCCBsheet metal enclosuremounted on wall with fastner and suitable size of nut and boltsafter taking down old existing un serviceable MCCB/SDFU complete all as specified and directed.. |
| 71 | Material and labourin replacement of Voltmeter 0-500 V digital type as per existing size complete all as per specified and directed. |
| 72 | Material and labourin replacement of Ammeter 0-400 Amp digital type per existing size complete all as per specified and directed |
| 73 | Supply and fixing in replacement of indicator lamp for RYB phases complete all as specified and directed. |
| 74 | M & L for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel/LT ACB panel and removing all rubbish to a distance not exceeding 50 m as directed. |
| 75 | Supply installation & commissioning in replacement of 24V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 02 Nos of 12 Volts-100 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:- |
| 76 | (a) Input working voltage-180 -270 Volts (b) Nominal Input Voltage - 230 V , AC , 50 Hz,1(c) On load input power factor- > 0.8(d) On load unit watt efficiencies-> 80% (e) No load losses of complete charge-< 10%(f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition.(h) Boost charging - 2.4 V/Cell .(j)Float charging -2.15 V/Cell(k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode.(l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm.(m)Short circuit-MCB protecton provided. |
| 77 | supply and fixing of stainless steel rope 6mm dia lowering down of high mast fitting complete all as specified and directed by Eng-in-charge |
| 78 | supply and fixing D clamp including nut, bolts and washer for high mast fitting complete all as specified and directed byEng-in-charge |
| 79 | supply and fixing 1.5 HP motor for operating the stainless steel rope through gear assembly complete all as specified and directed byEng-in-charge |
| 80 | supply and fixing gear assembly used for operating the stainless steel rope for lowering down the high mast fitting complete all as specified and directed byEng-in-charge |
| 81 | supply and fixing 2.5 Sqmm 5 Core flexible copper cable complete all as specified and directed byEng-in-charge |
| 82 | Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work orderand shall be verified by the Eng-in-charge |