Electrical And Mechanical Items Supply And Established Work Of Pudkuni Group Of Village Pumping Water Supply Scheme Under Jal Jeevan Mission In Block-Kapkot District-Bageshwar- Ips-1 Supply Of Electric Driven Horizontal Multistage I.S.I. Marked Centrifugal Clearwaterpump Capableof Delivering340 Lpm Discharge, Against A Total Head Of 470 Mtrcomplete With Coupling And Coupling Guards At Ips-1 2 Supply Of Suitable Capacity 60 H.P. Squirrel Cage / Tefc Electric Motor Suitable To Operate On 415±10% Voltsthree Phase, 50 Hz A.C. Supply. 3 Supply Of M.S. Fabricated Heavy Duty Base Plate For Mountingabovepump And Motor. 4 Supply Of75 Hp Oil Cooledfullyautomatic Auto Transformer Starter Suitable To Control Above Motor With Over Loadandunder Voltage Protection ( Withtrasnformer Oil ) 5 Supply Of Dust And Vermin Proof Cubical Type Floor Mounting Type Control Panal Made Out Of 14 / 16 Swg Sheat Having Bus Barbar Chamber With Copper Bus Bar Comprising Of Following 6 Incoming- 1 No 7 200 Amp Manually Operatedmcb Complete With Protection – 01 No 8 Voltmeter ( 0 To 500 Volt ) 100 Sq Mm Dialwith Selector Switch- 01 No 9 Ammeter ( 0 To 200 Amp ) 100 Sq Mm Dial Ct Operated Withselector Switch- 01 No 10 Phase Indicating Lamp Complete With Instruments Fuses And Toggle Switch-01 Set 11 Frequency Meter 100 Mm Dial 12 P.F. Meter 100 Mm Dial 13 On / Off Indicator 1Set 14 Kwr Meter – 1 No 15 Idmt Relay – 01 No 16 Outgoing- 2 Nos 17 200 Amp M.C.B. Manually Operatedcomplete With Protection – 01 No 18 Digital Voltmeter 0-500 V – 02 No 19 Digital Ammeter 0-200 Amp – 02 No 20 Lt Power Capacitorof Suitable Rating – 02 No 21 Single Phase Preventor-02 Nos 22 32 Ampm.C.C.B.For Lightand Fan- 1 No 23 Earth Fault Relay- 02Nos 24 Hour Counter Meter- 02 Nos 25 Phase Indicating Lamp Complete With Instruments , Fuses And Toggle Switch – 02 Set 26 Power Wiring And Earthing Materials 27 Supply Of 50Mm23 Core Copper Conductor Armoured Pvc Sheathed Cable Of 1.1 Kv Grade In Multi Run. 50 Mtr 28 Supply Of 70Mm23.5 Core Aluminum Conductor Armoured Pvc Sheathed Cable Of 1.1 Kv Grade In Multi Run. 30 Mtr 29 Supply Of Jointing Material Likeluggs Tape As Required Etc 01 Set 30 Complete Double Earthing Of All The Electrical Equipments With Earthing Materials Such As Earth Plate, Earth Strips , Coal, Salt Etc Required As Per Ie Rules 01 Set 31 Main Piping And Valves - 32 Suction Side 33 Ci / Df Sluice Valve Of Size 100 Mm With Hand Wheel P.N.1.6– 02 No 34 Ci / Df Bend 90°, 100 Mm Dia – 02No 35 M.S. / Df Taper Size Pump Inletx 100 Mm Dia – 02No 36 M.S / Df Pipe 100 Mm Size 8.00 Mm Thickness In 3.00 Mtr Length- 04No 37 100 Mm Dia M.S. Flange Of20 Mm Thickness- 12No 38 Delivery Side 39 Cast Steelgate Valve 80 Mm Size Of Class 600Asa-02No 40 Cast Steel Df Swing Check Valve 80 Mm Size Of Class 600 Asa -02No 41 M.S. / Df Enlarger Pump Outlet 80Mm – 02No 42 M.S. / Af Radial Tee Size 80X80x80mm – 02No 43 Blind Flange 80 Mm Size- 02 No 44 Ms / Df Distance Piece 80 Mm Size In3mtr Length -01No 45 Ms / Df Distance Piece 80 Mm Size In1.5 Mtr Length -03No 46 80Mm Dia M.S. Flange Of Thickness Of 20 Mm -12No 47 Nuts And Bolts , Rubber / Fiber Packing For Jointing Above Pipes And Sepcials. 1 Set 48 Ci / Df Bend 90 Degree 80 Mm Size – 02No 49 Ms / Df Taper Size Pump Outlet X80mm-02No 50 By Pass Arragement 51 Cast Steel / Df Swing Check Valve 80 Mm Size Of Class 600 Asa -01No 52 Cast Steel Gate Valve 80 Mm Size Of Class 600Asa-02No 53 Ms / Af Tee Size 80Mmx80mmx80 Mm-01No 54 Nuts And Bolts , Rubber / Fiber Packing For Jointing Above Items. 1 Set 55 Ci / Df Bend 90 Degree 80 Mm Size – 01No 56 Gauges 57 Supply Of 100 Mm Dial Pressure Gauge With Control Cock And Fittings Of Range 0-60 Kg / Cm2 -02 No 58 Supply Of 100 Mm Dial Compound Gauge With Control Cock And Fittings 0±1 Kg / Cm2- 02 Nos 59 Supply Of Following Tools Required For Maintenance Of Pumping Plants 60 De Spanner Set 1 Set 61 Ring Spaner Set- 1 Set 62 Screw Driver- 02No 63 Pliers- 01No 64 Hammers - 1 No 65 Pipe Wrinch 14- 1 No 66 Screw Wrench -1No 67 Tong Tester-1No 68 Crimping Tool ( Hydraulic Type ) -1No 69 Coupling Puller - 1 No 70 Bearing Puller-01No 71 Steel Almirah ( 5 1 / 2’X33’’X19’’ ) -01No 72 Plastic Table ( 3’X2’X2.5’’ ) 73 Plastic Chair -4No 74 Wall Clock – 1No 75 Data Chart Board- 1No 76 Chainpully Block Isi Marked 3.0 Ton 77 Supply Of Rubber Resistance Sheet Of Size 1Mx2mx0.025 M 78 Installation And Commissioning Of Pumping Plants With All Accesories Inside The Pump House But Without Civil Work Such As Laying Of Foundation Cable Trenches Etc. 79 Testing Of Pumping Plants Against Guaranteedfigure Of Schedule E 80 At Work 81 At Site 82 Maintanence For Stabilized The Whole System 83 Painting Of Entire Installation With 2 Coats Of Super Enamel Paints As Per Direction Of Engineer In Charge Of Works. 84 Internal And External Electrification Of Pump House 85 Isi Marked Servo Control Voltage Stabilizer 125 K.V.A. Suitable For Regulation Incoming Voltage 300 To 480 Voltage Outgoing Voltage 415 Volt With 250 Amp Change Over Switch And 35Mm2 3.5 Core Copper Cable First Filling Of Transformer Oil And Complete Installation. 86 Carriage Of Pumping Plants And All Accessories From Store To Site Of Work Including Head Load Charges From Road Site To Site Of Work As Required Material Cost I.E. Sub Total A 87 Insurance Of All Materials And Complete Works ( Contract Bond Value ) From The Supply Of Materials And Transition Freight To Store. 88 Ips-2 Supply Of Electrically Driven Horizontal Multistage I.S.I. Marked Centrifugal Clearwaterpump Capableof Delivering200 Lpm Discharge, Against A Total Head Of 560 Mtrcomplete With Coupling And Coupling Guardsat Ips2 89 Supply Of Suitable Capacity 40 H.P. Squirrel Cage / Tefc Electric Motor Suitable To Operate On 415±10% Voltsthree Phase, 50 Hz A.C. Supply. 90 Supply Of M.S. Fabricated Heavy Duty Base Plate For Mounting Abovepump And Motor. 91 Supply Of 60 Hp Oil Cooledfullyautomatic Auto Transformer Startersuitable To Control Above Motor With Over Loadandunder Voltage Protection ( Withtrasnformer Oil ) 92 Supply Of Dust And Vermin Proof Cubical Type Floor Mounting Type Control Panal Made Out Of 14 / 16 Swg Sheat Having Bus Barbar Chamber With Copper Bus Bar Comprising Of Following 93 Incoming- 1 No 94 160 Amp Manually Operatedmcb Complete With Protection – 01 No 95 Voltmtr ( 0 To 500 Volt ) 100 Sq Mm Dialwith Selector Switch- 01 No 96 Ammtr ( 0 To 200 Amp ) 100 Sq Mm Dial Ct Operated Withselector Switch- 01 No 97 Phase Indicating Lamp Complete With Instruments Fuses And Toggle Switch-01 Set 98 Frequency Meter 100 Mm Dial 99 P.F. Meter 100 Mm Dial 100 On / Offindicator – 1 Set 101 Kwr Meter – 1 No 102 Idmt Relay – 01 No 103 Outgoing- 2 Nos 104 M.C.B. 200 Amp Manually Operatedcomplete With Protection – 01 No 105 Digital Voltmtr 0-500 V – 02 No 106 Digital Ammtr 0-200 Amp – 02 No 107 Lt Power Capacitorof Suitable Rating – 02 No 108 Single Phase Preventor-02 Nos 109 32 Ampmccb For Lightand Fan- 1 No 110 Earth Fault Relay- 02Nos 111 Phase Indicating Lamp Complete With Instruments , Fuses And Toggle Switch – 02 Set 112 Power Wiring And Earthing Materials 113 Supply Of35mm23 Core Copper Conductor Armoured Pvc Sheathed Cable Of 1.1 Kv Grade In Multi Run. 50 Mtr 114 Supply Of 50Mm23.5 Core Aluminum Conductor Armoured Pvc Sheathed Cable Of 1.1 Kv Grade In Multi Run. 30 Mtr 115 Supply Of Jointing Material Likeluggs Tape As Required Etc- 01 Set 116 Complete Double Earthing Of All The Electrical Equipments With Earthing Materials Such As Earth Plate, Earth Strips , Coal, Salt Etc Required As Per Ie Rules 01 Set 117 Main Piping And Valves - 118 Suction Side 119 Ci / Df Sluice Valve Of Size 100 Mm With Hand Wheel P.N.1.6– 02 No 120 Ci / Df Bend 90°, 100 Mm Dia – 02No 121 M.S. / Df Taper Size Pump Inletx 100 Mm Dia – 02No 122 M.S / Df Pipe 100 Mm Size 8.00 Mm Thick In 3.00 Mtr Length- 04No 123 100 Mm Dia M.S. Flange Of20 Mm Thick- 12No 124 Delivery Side 125 Cast Steelgate Valve 80 Mm Size Of Class 600Asa-02No 126 Cast Steel Df Swing Check Valve 80 Mm Size Of Class 600 Asa -02No 127 M.S. / Df Enlarger Pump Outlet 80Mm – 02No 128 M.S. / Af Radial Tee Size 80X80x80mm – 02No 129 Blind Flange 80 Mm Size- 02 No 130 Ms / Df Distance Piece 80 Mm Size In3mtr Length -01No 131 Ms / Df Distance Piece 80 Mm Size In1.5 Mtr Length -03No 132 80Mm Dia M.S. Flange Of Thickness Of 20 Mm -12No 133 Nuts And Bolts , Rubber / Fiber Packing For Jointing Above Pipes And Sepcials. 1 Set 134 Ci / Df Bend 90 Degree 80 Mm Size – 02No 135 Ms / Df Taper Size Pump Outlet X80mm-02No 136 By Pass Arragement 137 Cast Steel / Df Swing Check Valve 80 Mm Size Of Class 600 Asa -01No 138 Cast Steel Gate Valve 80 Mm Size Of Class 600Asa-02No 139 Ms / Af Tee Size 80Mmx80mmx80 Mm-01No 140 Nuts And Bolts , Rubber / Fiber Packing For Jointing Above Pipes And Sepcials. 1 Set 141 Ci / Df Bend 90 Degree 80 Mm Size – 01No 142 Gauges 143 Supply Of 100 Mm Dial Pressure Gauge With Control Cock And Fittings Of Range 0-60 Kg / Cm2 -02 No 144 Supply Of 100 Mm Dial Compound Gauge With Control Cock And Fittings 0±1 Kg / Cm2- 02 Nos 145 Supply Of Following Tools Required For Maintenance Of Pumping Plants 146 De Spanner Set 1 Set 147 Ring Spaner Set- 1 Set 148 Screw Driver- 02No 149 Pliers- 01No 150 Hammers - 1 No 151 Pipe Wrinch 14- 1 No 152 Screw Wrench -1No 153 Tong Tester-1No 154 Crimping Tool ( Hydraulic Type ) -1No 155 Coupling Puller - 1 No 156 Bearing Puller-01No 157 Steel Almirah ( 51 / 2’X33’’X19’’ ) -01No 158 Plastic Table ( 3’X2’X2.5’’ ) 159 Plastic Chair -4No 160 Wall Clock – 1No 161 Data Chart Board- 1No 162 Isi Marked H.O.T. Crane Of 3 Tonne Capacity Including Gantry, Girder , Cross Girder, Chain Pully Block Etc As Required 163 Supply Of Rubber Resistance Sheet Of Size 1Mx2mx0.025 M 164 Installation And Commissioning Of Pumping Plants With All Accesories Inside The Pump House But Without Civil Work Such As Laying Of Foundation Cable Trenches Etc. 165 Testing Of Pumping Plants Against Guaranteedfigure Of Schedule E 166 At Work 167 At Site 168 Maintanence For Stabilized The Whole System 169 Painting Of Entire Installation With 2 Coats Of Super Enamel Paints As Per Direction Of Engineer In Charge Of Works. 170 Carriage Of Pumping Plants And All Accessories From Store To Site Of Work Including Head Load Charges From Road Site To Site Of Work As Required Material Cost I.E. Sub Total A 171 Isi Marked Servo Control Voltage Stabilizer 80 K.V.A. Suitable For Regulation Incoming Voltage 300 To 480 Voltage Outgoing Voltage 415 Volt With 200 Amp Change Over Switch And 35Mm2 3.5 Core Copper Cable First Filling Of Transformer Oil And Complete Installation. 172 Internal And External Electrification Of Pump House 173 Insurance Of All Materials And Complete Works ( Contract Bond Value ) From The Supply Of Materials And Transition Freight To Store. 174 Mpssupply Of Electrically Driven Horizontal Multistage I.S.I. Marked Centrifugal Clearwaterpump Capableof Delivering340 Lpm Discharge, Against A Total Head Of 465 Mtrcomplete With Coupling And Coupling Guards At M.P.S. 175 Supply Of Suitable Capacity 60 H.P. Squirrel Cage / Tefc Electric Motor Suitable To Operate On 415±10% Voltsthree Phase, 50 Hz A.C. Supply. 176 Supply Of M.S. Fabricated Heavy Duty Base Plate For Mountingpump And Motor. 177 Supply Of75 Hp Oil Cooledfullyautomatic Auto Transformer Starter Suitable To Control Above Motor With Over Loadandunder Voltage Protection ( Withtrasnformer Oil ) 178 Supply Of Dust And Vermin Proof Cubical Type Floor Mounting Type Control Panal Made Out Of 14 / 16 Swg Sheat Having Bus Barbar Chamber With Copper Bus Bar Comprising Of Following 179 Incoming- 1 No 180 200 Amp Manually Operatedmcb Complete With Protection – 01 No 181 Voltmtr ( 0 To 500 Volt ) 100 Sq Mm Dialwith Selector Switch- 01 No 182 Ammtr ( 0 To 200 Amp ) 100 Sq Mm Dial Ct Operated Withselector Switch- 01 No 183 Phase Indicating Lamp Complete With Instruments Fuses And Toggle Switch-01 Set 184 Frequency Meter 100 Mm Dial 185 P.F. Meter 100 Mm Dial 186 On / Offindicator – 1 Set 187 Kwr Meter – 1 No 188 Idmt Relay – 01 No 189 Outgoing- 2 Nos 190 M.C.B. 200 Amp Manually Operatedcomplete With Protection – 01 No 191 Digital Voltmtr 0-500 V – 02 No 192 Digital Ammtr 0-200 Amp – 02 No 193 Lt Power Capacitorof Suitable Rating – 02 No 194 Single Phase Preventor-02 Nos 195 M.C.B. 32 Ampfor Lightand Fan- 1 No 196 Earth Fault Relay- 02Nos 197 Hour Counter Meter- 02 Nos 198 Phase Indicating Lamp Complete With Instruments , Fuses And Toggle Switch – 02 Set 199 Power Wiring And Earthing Materials 200 Supply Of 50Mm23 Core Copper Conductor Armoured Pvc Sheathed Cable Of 1.1 Kv Grade In Multi Run.- 50 Mtr 201 Supply Of 70Mm23.5 Core Aluminum Conductor Armoured Pvc Sheathed Cable Of 1.1 Kv Grade In Multi Run.- 30 Mtr 202 Supply Of Jointing Material Likeluggs Tape As Required Etc - 1 Set 203 Complete Double Earthing Of All The Electrical Equipments With Earthing Materials Such As Earth Plate, Earth Strips , Coal, Salt Etc Required As Per Ie Rules - 1 Set 204 Main Piping And Valves - 205 Suction Side 206 Ci / Df Sluice Valve Of Size 100 Mm With Hand Wheel P.N.1.6– 02 No 207 Ci / Df Bend 90°, 100 Mm Dia – 02No 208 M.S. / Df Taper Size Pump Inletx 100 Mm Dia – 02No 209 M.S / Df Pipe 100 Mm Size 8.00 Mm Thick In 3.00 Mtr Length- 04No 210 100 Mm Dia M.S. Flange Of20 Mm Thick- 12No 211 Delivery Side 212 Cast Steelgate Valve 80 Mm Size Of Class 600Asa-02No 213 Cast Steel Df Swing Check Valve 80 Mm Size Of Class 600 Asa -02No 214 M.S. / Df Enlarger Pump Outlet 80Mm – 02No 215 M.S. / Af Radial Tee Size 80X80x80mm – 02No 216 Blind Flange 80 Mm Size- 02 No 217 Ms / Df Distance Piece 80 Mm Size In3mtr Length -01No 218 Ms / Df Distance Piece 80 Mm Size In1.5 Mtr Length -03No 219 80Mm Dia M.S. Flange Of Thickness Of 20 Mm -12No 220 Nuts And Bolts , Rubber / Fiber Packing For Jointing Above Pipes And Sepcials. 1 Set 221 Ci / Df Bend 90 Degree 80 Mm Size – 02No 222 Ms / Df Taper Size Pump Outlet X80mm-02No 223 By Pass Arragement 224 Cast Steel / Df Swing Check Valve 80 Mm Size Of Class 600 Asa -01No 225 Cast Steel Gate Valve 80 Mm Size Of Class 600Asa-02No 226 Ms / Af Tee Size 80Mmx80mmx80 Mm-01No 227 Nuts And Bolts , Rubber / Fiber Packing For Jointing Above Items. 1 Set 228 Ci / Df Bend 90 Degree 80 Mm Size – 01No 229 Gauges 230 Supply Of 100 Mm Dial Pressure Gauge With Control Cock And Fittings Of Range 0-60 Kg / Cm2 -02 No 231 Supply Of 100 Mm Dial Compound Gauge With Control Cock And Fittings 0±1 Kg / Cm2- 02 Nos 232 Supply Of Following Tools Required For Maintenance Of Pumping Plants 233 De Spanner Set 1 Set 234 Ring Spaner Set- 1 Set 235 Screw Driver- 02No 236 Pliers- 01No 237 Hammers - 1 No 238 Pipe Wrinch 14- 1 No 239 Screw Wrench -1No 240 Tong Tester-1No 241 Crimping Tool ( Hydraulic Type ) -1No 242 Coupling Puller - 1 No 243 Bearing Puller-01No 244 Steel Almirah ( 51 / 2’X33’’X19’’ ) -01No 245 Plastic Table ( 3’X2’X2.5’’ ) 246 Plastic Chair -4No 247 Wall Clock – 1No 248 Data Chart Board- 1No 249 Chainpully Block Isi Marked 3.0 Ton 250 Supply Of Rubber Resistance Sheet Of Size 1Mx2mx0.025 M 251 Installation And Commissioning Of Pumping Plants With All Accesories Inside The Pump House But Without Civil Work Such As Laying Of Foundation Cable Trenches Etc. 252 Testing Of Pumping Plants Against Guaranteedfigure Of Schedule E 253 At Work 254 At Site 255 Maintanence For Stabilized The Whole System 256 Painting Of Entire Installation With 2 Coats Of Super Enamel Paints As Per Direction Of Engineer In Charge Of Works. 257 Internal And External Electrification Of Pump House 258 Isi Marked Servo Control Voltage Stabilizer 125 K.V.A. Suitable For Regulation Incoming Voltage 300 To 480 Voltage Outgoing Voltage 415 Volt With 250 Amp Change Over Switch And 35Mm2 3.5 Core Copper Cable First Filling Of Transformer Oil And Complete Installation. 259 Carriage Of Pumping Plants And All Accessories From Store To Site Of Work Including Head Load Charges From Road Site To Site Of Work As Required Material Cost I.E. Sub Total A 260 Insurance Of All Materials And Complete Works ( Contract Bond Value ) From The Supply Of Materials And Transition Freight To Store. 261 Infiltration Well Supply Of Submersible Raw Waterpumping Plant Capableof 340 L.P.M. Cold And Clear Water Againts Total Head Of 80 Mtr Directly Coupled To A Submersible Motor Of 10 H.P. Suitable To Operate On 415±10% Volts Three Phase 50 C / S A.C. ( Supple Complete With Non Return Valve ) At Infiltration Well 262 Supply Of 15 H.P. Floor Mounted Type Fully Automatic Star Delta Starter Suitable To Operate On 400 / 440 Volt , Threephase .50A.C. With Over Load Relay & Over / Under Volatage Protection 263 Supply Of 63 Amp Three Phase Main Switch With Neutral Link 264 Supply Of Dust And Vermin Proof Cubical Floor Mountingtype Control Panel Made Out Of 14 Swg Sheat Steelhaving Bus Bar Bar Comprising Of Following One No Incoming And Two Nos Of Outgoings 265 Incoming- 1 Number 266 Mccb 63 Amp ( Adjustable Type ) With Shunt Trip Microprocesor Release Heavy Over Current Earth Fault Short Circuit Protection And Under Voltage Release – 01 No 267 Voltmtr ( 0 To 500 Volt ) 100 Sq Mm Dial With Selector Switch- 01 No 268 Ammeter ( 0 To 100 Amp ) 100 Sq Mm Dialwith Ct & Selector Switch- 01 No 269 Phase Indicating Lamp Complete With Instruments Fuse And Switch-01 No 270 Switch Relay For Automatic On / Off For Panel For Power Supply- 01 No 271 Idmt Relay – 01 No 272 Outgoing-2 Numbers 273 Mccb 63 Amp ( Adjustable Type ) With Shunt Trip Microprocesor Release Heavy Over Current Earth Fault Short Circuit Protection And Under Voltage Release – 02 No 274 Ammeter 100 Sq Mm Dial ( 0 To 100 Amp ) Withselector Switch- 02 No 275 Lt Power Capacitor Bank Of Suitable Capacity To Improve Power Factor – 02 No 276 Hour Counter Meter- 02 Nos 277 Phase Indicating Lamp Complete With Instrument , Fuses And Toggle Switch – 02 Set 278 Single Phase Preventor-02 Nos 279 M.C.B. 32 Ampfor Light Power Point And Fan - 1 No 280 Power Wiring And Earthing Materials 281 Supply Of 10 Mm Sq 3 Core P.V.C. Insulated Copper Conductor Submersible Cable - 60 Mtr 282 Supply Of 35 Mm Sq 3.5 Core Aluminum Conductor Armoured P.V.C. Sheathed Cable Of 1.1 Kv Grade- 30 Mtr. 283 Supply Of 16 Mm Sq 3.5 Core Aluminum Conductor Armoured P.V.C. Sheathed Cable Of 1.1 Kv Grade-40 Mtr 284 Supply Of Jointing Material Like. Lugs Tapes As Required Etc 285 Complete Double Earthing Of All The Electrical Equipments With Earthing Materials Such As Earth Plate, Earth Strips , Coal, Salt Etc Required As Per Ie Rules 286 Main Piping And Valves 287 100 Mm M.S. Column Pipe Assembly Having 7.1 Thick Mm Both Ends Socketed In 3.00 Mtr Length – 06 No 288 100 Mm Dia M.S. Top Column Pipe Assembly Having7.1 Thick Mm One End Threaded And One End With Flange Welded In3.00 Mte Length- 02No 289 M.S. Reducer Pump Outlet Size X 100 Mm Dia – 02No 290 Msd / F Bend 90° 100 Mm Dia – 02No 291 100 Mm Dia Cast Iron D / F Gate Valve With Hand Wheel Of Class P.N. 1.6 – 04No 292 100 Mm Dia Cast Iron D / F Swing Check Valve Of Class P.N. 1.6 – 03No 293 100 Mm Dia Msd / F Distance Piece As Per Site Requirement – 01 Set 294 100 X100x100 Mm Dia Msd / F Radial Tee- 03No 295 100 Mm Dia M.S. Blind Flange- 01No 296 Nuts , Bolts, Rubber / Fiber Packing For Jointing Above Pipes & Specials 1 Lot 297 Gauges 298 Supply Of 150 Mm Dial Pressure Gauge With Control Cock And Fittings Of Range 0-20 Kg / Cm2 -02No 299 Supply Of 150 Mm Dial Depth Gauge Direct Reading Type Complete With Airline And Fittings – 02No 300 Supply Of Following Tools Required For Maintenance Of Pumping Plants 301 De Spanner Set- 1 Set 302 Ring Spanner Set- 1 Set 303 Screw Driver- 02No 304 Insulation Plier- 01No 305 Hammer 2Kg With Handle -1No 306 Pipe Wrench Suitable Size- 1 No 307 Screw Wrench -1No 308 Crimping Tool-1No 309 Tong Tester-1No 310 Chain Wrench Suitable Size-2No 311 Supply Of Isi Marked Chain Pulley Block Of 3 Ton Capacity 6 Mtrs. Lift Complete With Travelling Trolley. 312 Supply Of Rubber Resistance Sheet Of Size 1Mx2mx0.015M 313 Fire Extenguisher 6Kg, 2 Nos Co2 And 2Nos Abc 314 Supply Of Material For Pump House 315 Steel Almirah ( 51 / 2’X33’’X19’’ ) -01 No 316 Plastic Table ( 3’X2’X2.5’’ ) 317 Plastic Chair -4 Nos 318 Wall Clock – 1 No 319 Data Chart Board- 1 No 320 Installation And Commissioning Of Pumping Plants With All Accessories Inside The Pump House But Without Civil Work I.E. Laying Of Foundation Cable Trenches Etc. 321 Testing Of Pumping Plants Againstfigure Of Schedule E 322 At Work 323 At Site 324 Painting Of Entire Installation With 2 Coats Of Super Enamel Paints As Per Direction Of Engineer In Charge Of Works. 325 Internal And External Electrification Of Pump House 326 Cartage Of Pumping Plants And All Accessories From Store To Site Of Work Including Head Load Charges From Road Site To Site Of Work As Required. 327 Insurance Of Whole Worls ( Including All Materials ) For Transit, Storage, Re Shipment To Site, Erection / Commissioning From The Start Date The End Of The Defects Liability Period And Personal Injury And Death Which Are Due To Contractors Risk. 328 Labour Engaged In Operation And Maintenace Of All Stages Of Scheme For 6 Months 329 Pump Operator 330 Chowkidar 331 Electrician 332 Mechanic