}

Bids Are Invited For Electrical Equipments For Iti (Q3) Total Quantity : 1, Bargarh-Odisha

Government Departments has published Bids Are Invited For Electrical Equipments For Iti (Q3) Total Quantity : 1. Submission Date for this Tender is 19-06-2023. Cutting Crimping and Punching Tools Tenders in Bargarh Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

37897379
Bids Are Invited For Electrical Equipments For Iti (Q3) Total Quantity : 1
Open Tender
Indian
Odisha
Bargarh
19-06-2023

Tender Details

Bids Are Invited For Electrical Equipments For Iti ( Q3 ) , 1. Ohm Meter; Shunt Type, Portable Box Type Housed In Bakelite Case 50 / 2000-Ohm Analog 4 2. Ohm Meter; Series Type Portable Box Type Housed In Bakelite Case 50 / 2000-Ohm Analog 4 3. A.C. Voltmeter M.I. Analog, Portable Box Type Housed In Bakelite Case Multi Range 75 V - 150V - 300V - 600V 6 4. Milli Voltmeter Centre Zero Analog, Portable Box Type Housed In Bakelite Case 100 – 0 – 100 Mv 4 5. Ammeter Mc Analog, Portable Box Type Housed In Bakelite Case 0 - 500 Ma 4 6. Ammeter Mc Analog, Portable Box Type Housed In Bakelite Case 0-5 A 4 7. Ammeter Mc Analog, Portable Box Type Housed In Bakelite Case 0-25 A 4 8. Ac Ammeter Mi, Analog, Portable Box Type Housed In Bakelite Case 0 - 1 A 4 9. Ac Ammeter Mi, Analog, Portable Box Type Housed In Bakelite Case 0-5 A 4 10. Ac Ammeter Mi, Analog, Portable Box Type Housed In Bakelite Case 0-25 A 4 11. Kilo Wattmeter Analog, Portable Box Type Housed In Bakelite Case 0-1.5-3Kw, Pressure Coil Rating- 240V / 440V, Current Rating-5A / 10A 4 12. Digital Wattmeter, Portable Box Type Housed In Bakelite Case 230 V, 1 Kw, 50 Hz 4 13. A.C. Energy Meter Single Phase, 10 A, 240 V Induction Type 4 14. A.C. Energy Meter Three Phase, 15 A , 440 V Induction Type 4 15. Power Factor Meter Digital, Portable Box Type Housed In Bakelite Case 440 V, 20 A, Three Phase 4 16. Frequency Meter, Portable Box Type Housed In Bakelite Case 45 To 55 Hz 4 17. Magnetic Flux Meter, Portable Box Type Housed In Bakelite Case 0-500 Tesla 4 18. Lux Meter Lux Meter Lcd Read Out 0.05 To 7000 Lumens With Battery. 4 19. 3- Point D.C. Starter For 2.5 Kw Dc Motor 2 20. 4- Point D.C. Starter For 2.5 Kw Dc Motor 2 21. Wheat Stone Bridge With Galvanometer And Battery 4 22. Single Phase Variable Auto Transformer 0 - 270 V, 10Amp ( Air Cooled ) 4 23. Phase Sequence Indicator 3 Phase, 415 V 4 24. Growler 230 V, 50 Hz, Single Phase, Adjustable Jaws, Testing Armature With Ampere Meter And Testing Probes. 2 25. Resistance Type Starter For A.C Motors Of 2 To 5 H.P. 2 26. Direct Online Starter For A.C Motors Of 2 To 5 H.P. 2 27. Star Delta Starter- Manual For A.C Motors Of 2 To 5 H.P. 2 28. Star Delta Starter – Semi Automatic For A.C Motors Of 2 To 5 H.P. 2 29. Star Delta Starter – Fully Automatic For A.C Motors Of 2 To 5 H.P. 2 30. Star Delta Starter - Soft Starter For A.C Motors Of 2 To 5 H.P. 2 31. Auto Transformer Type For A.C Motors Of 2 To 5 H.P. 2 32. Battery Charger 0 - 6 - 9 - 12 - 24 - 48 V, 30Amp 2 33. Current Transformer 415 V, 50Hz, Ct Ratio 25 / 5 A, 5Va 4 34. Potential Transformer 415 V, 50Hz, Pt Ratio, 440V / 110V, 10Va 4 35. A. Electric Induction Plate With Demonstration Kit A. 1500 Watt, 240V 2 36. B. Electric Kettle B. 1500 Watts, 240V 2 37. C. Electric Iron C. Automatic - 750 W, 240 V 2 38. D. Immersion Heater D. 1500 Watt, 240V 2 39. E. A.C. Ceiling Fan With Demonstration Kit E. 68-Watt, 230 V, 1200 Mm 1 40. F. Geyser ( Storage Type ) F. 10 Litre 2 41. G. Mixture & Grinder With Demonstration Kit G. 750 W, 240 V 2 42. H. Washing Machine Semi-Automatic With Demonstration Kit H. 5 Kg 1 43. I. Motor Pump Set I. 1 Hp, 1 Phase, 240 V 2 44. J. Ac Stand Fan With Regulator Heavy Duty J. 68-Watt, 230 V 2 45. K. Bldc Ceiling Fan With Demonstration Kit K. 30W, 1200Mm 1 46. L. Washing Machine Automatic With Demonstration Kit H. 5 Kg 1 47. Inverter 1 Kva With 180Ah Battery 1 Kva With 12 V Battery Input- 12 Volt Dc, Output- 220 Volt Ac, 180Ah 2 48. Cut Out Relays A. 16A, 440V 1 49. Reverse Current Relay B. 16A, 440V 1 50. Over-Current C. 16A, 440V 1 51. Under Voltage D. 360V-440V 1 52 Cut Out Relays Trainer Kit With Table And Panel Cut Out Relays : Cut Out Relay Objective: •To Study The Construction Of Relay •Test An Relay In Instantaneous Cut Out Protection Scheme For Operating Characteristic Using Current Injection The Components Fitted On The Panel Labelled With The Name Of The Component. All Accessories Connected With Internal Wiring. The Control Panel Shall Consist Of An Instrument Panel With All Digital Meters Shall Highly Accurate Micro - 1 Controller Based With Diagrammatic Representation For The Ease Of Connections And Student Can Easily Understand The Concept Of Machine And The Control Panel Should Be Made Of 40X40 Sq. Mm Aluminium Conveyer Section With All The Accessories Mounted On The Bakelite Sheet / M.S. Sheet With Vinyl Sticker As Per The Circuit Diagram Of The Experiment With Laminated Wooden Top On The Working Area. The Basic Frame Work Shall Be Made Of 40X40x2mm Sq. Mm Aluminium Conveyer Section . The Overall Dimensions Should Be Not Less Than W = 1200 Mm ; D = 900 Mm ; H = 1500 Mm . A 25Mm Thick Work Top Made From 25Mm Wood Based Plain Particle Board With One Side Post Forming ( Full Round Profile ) 0.8Mm Marino Laminate And Another Side 0.6Mm White Balancing Laminate. Remaining Three Sides Of The Work Top Should Be Lipped With 2Mm Pvc Edge Band. Leveling Screws With Base Should Be Provided On The Legs Of The Work Bench. Technical Specifications: •Relay Type : Instantaneous Cut Out Relay •Terminals : 4Mm Terminals For Trip, Current Output And Input •Meters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer .0001Sec. To 9999Sec. ( Auto ) •Current Injector : Inbuilt Variable Current Injector Amps 20Amps To Create Phantom Fault Current •Indicators : Provided On Front Panel For Mains, Current, Trip And Alarm •Switches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) •Power Requirement : 220Vac +10%, 50Hz Standard Accessories: • Power Cords, Patch Cords, Instruction Manual. 53 Reverse Current Relay Trainer Kit With Table And Panel Reverse Current : Reverse Current The Components Fitted On The Panel Labelled With The Name Of The Component. All Accessories Connected With Internal Wiring. The Control Panel Shall Consist Of An Instrument Panel With All Digital Meters Shall Highly Accurate Micro - Controller Based With Diagrammatic Representation For The Ease Of Connections And Student Can Easily Understand The Concept Of Machine And The Control Panel Should Be Made Of 40X40 Sq. Mm Aluminium Conveyer Section With All The Accessories Mounted On The Bakelite Sheet / M.S. Sheet With Vinyl Sticker As Per The Circuit Diagram Of The Experiment With Laminated Wooden Top On The Working Area. 1 The Basic Frame Work Shall Be Made Of 40X40x2mm Sq. Mm Aluminium Conveyer Section . The Overall Dimensions Should Be Not Less Than W = 1200 Mm ; D = 900 Mm ; H = 1500 Mm . A 25Mm Thick Work Top Made From 25Mm Wood Based Plain Particle Board With One Side Post Forming ( Full Round Profile ) 0.8Mm Marino Laminate And Another Side 0.6Mm White Balancing Laminate. Remaining Three Sides Of The Work Top Should Be Lipped With 2Mm Pvc Edge Band. Leveling Screws With Base Should Be Provided On The Legs Of The Work Bench. The Experimental Setup Consists Of The Following Parts: One Nos. Of Reverse Power Relay Provided On The Front Panel. One Nos. Of Digital Current Meter ( 0-20A ) Of Size 96X 48 Mm Provided On The Front Panel. One Nos. Of Digital Timer Provided On The Front Panel. Circuit Diagram Printed On Front Panel With Instruments Connecting Lamp I.E Trip, Current & Alarm. Power Re Quirement : Sin Gle Phase 230V / 50Hz . 54 Over-Current Trainer Kit With Table And Panel Over Current: •To Study The Operating Characteristics Of Relay •To Study The Time – Current Characteristics Of The Given Fuse The Components Fitted On The Panel Labelled With The Name Of The Component. All Accessories Connected With Internal Wiring. The Control Panel Shall Consist Of An Instrument Panel With All Digital Meters Shall Highly Accurate Micro - Controller Based With Diagrammatic Representation For The Ease Of Connections And Student Can Easily Understand The Concept Of Machine And The Control Panel Should Be Made Of 40X40 Sq. Mm Aluminium Conveyer Section With All The Accessories Mounted On The Bakelite Sheet / M.S. Sheet With Vinyl Sticker As Per The Circuit Diagram Of The Experiment With Laminated Wooden Top On The Working Area. The Basic Frame Work Shall Be Made Of40x40x2mm Sq. Mm Aluminium Conveyer Section .The Overall Dimensions Should Be Not Less Than W = 1200 Mm ; D = 900 Mm ; H = 1500 Mm . A 25Mm Thick Work Top Made From 25Mm Wood Based Plain Particle Board With One Side Post Forming ( Full Round Profile ) 0.8Mm Marino Laminate And Another Side 0.6Mm White Balancing Laminate. Remaining Three Sides Of The Work Top Should Be Lipped With 2Mm Pvc Edge 1 Band. Leveling Screws With Base Should Be Provided On The Legs Of The Work Bench. Technical Specifications: •Relay Type :Thermal Over Load Relay •Terminals : 4Mm Terminals For Trip, Current Output And Input •Meters ( Digital ) : 1No. Ac Current Meter 0 – 20Amps & 1 No. Digital Timer .0001Sec. To 9999Sec. ( Auto ) •Current Injector : Inbuilt Variable Current Injector 20Amps To Create Phantom Fault Current •Indicators : Provided On Front Panel For Mains, Current, Trip And Alarm •Switches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) •Relay Circuit Diagram : Screen Printed On Front Panel •Power Requirement : 220Vac +10%, 50Hz Standard Accessories: •Power Cords, Patch Cords, Instruction Manual . 55 Under Voltage Trainer Kit With Table And Panel Under Voltage : To Study The Construction Of Relay •Test An Relay In Over / Under Voltage Protection Scheme For Operating Characteristic Using Voltage Injection •To Obtain The Time & Current Characteristics Of A Over / Under Voltage Type Relay ( Static ) The Components Fitted On The Panel Labelled With The Name Of The Component. All Accessories Connected With Internal Wiring. The Control Panel Shall Consist Of An Instrument Panel With All Digital Meters Shall Highly Accurate Micro - Controller Based With Diagrammatic Representation For The Ease Of Connections And Student Can Easily Understand The Concept Of Machine And The Control Panel Should Be Made Of 40X40 Sq. Mm Aluminium Conveyer Section With All The Accessories Mounted On The Bakelite Sheet / M.S. Sheet With Vinyl Sticker As Per The Circuit Diagram Of The Experiment With Laminated Wooden Top On The Working Area. The Basic Frame Work Shall Be Made Of 40X40x2mm Sq. Mm Aluminium Conveyer Section . The Overall Dimensions Should Be Not Less Than W = 1200 Mm ; D = 900 Mm ; H = 1500 Mm . A 25Mm Thick Work Top Made From 25Mm Wood Based Plain Particle Board With One Side Post Forming ( Full Round Profile ) 0.8Mm Marino Laminate And Another Side 0.6Mm White Balancing Laminate. Remaining Three Sides Of The Work Top Should Be Lipped With 2Mm Pvc Edge Band. Leveling Screws With Base Should Be Provided On The Legs Of The Work Bench. 1 Technical Specifications: •Relay Type : Under Voltage Relay ( Static Type ) •Terminals : 4Mm Terminals For Trip, Voltage Output And Input •Meters ( Digital ) : 1No. Ac Voltmeter Meter 0 – 220V & 1 No. Digital Timer . .0001Sec. To 9999Sec. ( Auto ) •Voltage Injector : Inbuilt Variable Voltage Injector 220V To Create Fault Voltage •Indicators : Provided On Front Panel For Mains, Voltage, Trip And Alarm •Switches : Provided On Front Panel For Mains, Timer Reset, Test Switch ( On / Off ) •Relay Circuit Diagram : Screen Printed On Front Panel •Power Requirement : 220Vac +10%, 50Hz Standard Accessories: •Power Cords, Patch Cords, Instruction Manual 56 Hand Drill Machine 0-6 Mm Capacity 4 57 Portable Electric Drill Machine 0-12 Mm Capacity 750W, 240V With Chuck And Key 2 58 Load Bank ( Resistive Type ) 6 Kw, 3Ph 1 59 Brake Test Arrangement With Two Spring Balance Rating 0 To 25 Kg 2 60 Load Bank ( Inductive Type ) 6 Kw, 3Ph 1 61 Rheostat 0 - 25 Ohm, 2 Amp 2 62 Rheostat 0 - 300 Ohm, 2 Amp 2 63 Rheostat 0 -1 Ohm, 10Amp 2 64 Rheostat 0 -10 Ohm, 5 Amp 2 Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail