Supply Of Different Type New Abb Make Ac Vfd With Installation And Commissioning For Season 2023-24 , Supply Of Different Type New Abb Make Ac Vfd With Installation & Commissioning , A. Vfd Panel 160Kw Heavy Duty Application- Injection Pump, Make- Abb , Series, Model- Acs580-01-363A-4+J425, With Complete Panel As Per Attached Specificationsinstallation & Commissioning Of Panel Including Automatic Control Of Rpm According To The Injection Header Pressure. 1. Main Incomer - I. Mccb Microprocessor Based - 01 No., Ii. Semiconductor Fuse- 03 Nos. Iii. Hrc Fuse 2A With Base- 03 Nos., Iv. Phase Indication 230Vac- 01 No., V. Voltmeter 0 - 500V Ac- 01 No., Vi. Voltage Selector Switch- 01 No., Vii. Door Limit Switch- 01 No., Viii. Panel Lamp- 01 No., Ix. Thermostate- 01 No., X. Space Heater - 01 No., Xi. Mcb 10A, Dp For Control- 02 Nos., Xii. Control Transformer 500Va, 415V / 0..240V Ac- 01 No., Xiii. Vfd180 Kw Heavy Duty- 01 No., Xiv. Aux. Contactor- 06 Nos., Xv. Ready / Run / Trip- 03 Nos., Xvi. Start / Stop / Speed Inc. / Decpush Button- 04 Nos., Xvii. Local / Remote Switch- 01 No., Xviii. Emg. Stop Pb- 01 No., Xix. Signal Isolator Duel Channel- 02 Nos., Xx. Signal Isolator Single Channel- 01 No., Xxi. Control Terminal- 50 Nos.B. Plc System For Close Loop Control Of Injection Header Pressure ( 8Ai, 8Ao, 8Di, 8Do Eth , Rs485 Modbus ) , Including Pressure Transmitter ( 0 To 40 Kg / Cm2 ) With All Accessories Including 7 Inch Touch Panel, Complete Erection Work Of Instrumentation And Electrical Shall Be In Vendor Scope. - 01Setc. Power Terminal- 01 No. D. Panelling- I. Panel 800X2000x600- 01 No., Ii. Wiring & Accessories- 01 No., Iii.Busbar Cu- 01 No. E. Remote Control Station- I. Start / Stop Push Button- 01 No., Ii. Speed Increase / Decrease Push Button- 01 No., Iii. Rpm Meter0-1500Rpm, Input 0-10V - 01 No., Vi. Ready / Run / Trip Indication- 01 No., V. Reset Pb - 02 Nos. , A. Vfd Panel 132Kw Heavy Duty Application- Mill Trrpf, Make- Abb , Series Model-Acs580-01-293A-4+J425 With Complete Panel As Per Attached Specifications Installation & Commissioning Of Panel Including Automatic Control Of Rpm According To The Load And Complete Interlocking With Inter Rack Carriers &Mill Complete System Should Be Communicate With Existing Acfc Plc System Shall Be In Vendor Scope As Required. 1. Main Incomer - I. Mccb Microprocessor Based 315A- 01 No., Ii. Semiconductor Fuse 315A- 03 Nos. Iii. Hrc Fuse 2A With Base- 03 Nos., Iv. Phase Indication 230Vac- 01 No., V. Voltmeter 0 - 500V Ac- 01 No., Vi. Voltage Selector Switch- 01 No., Vii. Door Limit Switch- 01 No., Viii. Panel Lamp- 01 No., Ix. Thermostate- 01 No., X. Space Heater - 01 No., Xi. Mcb 10A, Dp For Control- 02 Nos., Xii. Control Transformer 500Va, 415V / 0..240V Ac- 01 No., Xiii. Vfd132 Kw Heavy Duty- 01 No., Xiv. Aux. Contactor- 06 Nos., Xv. Ready / Run / Trip- 03 Nos., Xvi. Start / Stop / Speed Inc. / Decpush Button- 04 Nos., Xvii. Local / Remote Switch- 01 No., Xviii. Emg. Stop Pb- 01 No., Xix. Signal Isolator Duel Channel- 02 Nos., Xx. Signal Isolator Single Channel- 01 No., Xxi. Control Terminal- 50 Nos. B. Plc System For Close Loop Control With Load Of Trpf And Mill, Interlocking With Trpf & Mill ( 8Ai, 8Ao, 8Di, 8Do Eth , Rs485 Modbus ) , This New Plc System Shall Be Communicate With Exiting Plc System, Including 7 Inch Touch Panel, Complete Programming Modification If Required Of Existing System Shall Be In Vendor Scope.C. Power Terminal- 03 Nos. D. Remote Control Station- I. Start / Stop Push Button- 01 No., Ii. Speed Increase / Decrease Push Button- 01 No., Iii. Rpm Meter0-1500Rpm, Input 0-10V - 01 No., Vi. Ready / Run / Trip Indication- 01 No., V. Reset Pb - 02 Nos.E. Panelling- I. Panel 800X2000x600- 01 No., Ii. Wiring & Accessories- 01 No., Iii.Busbar Cu- 01 No