}

Tender For Supply Of Pressure Transmitter (Pt) And Differential Pressure Transmitter (Dpt) At Katpp, Jhalawar, jhalawar-Rajasthan

Rajasthan Rajya Vidyut Utpadan Nigam Limited has published Tender For Supply Of Pressure Transmitter (Pt) And Differential Pressure Transmitter (Dpt) At Katpp, Jhalawar. Submission Date for this Tender is 02-08-2023. Power Transformer Tenders in jhalawar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

37860577
Corrigendum : Tender For Supply Of Pressure Transmitter (Pt) And Differential Pressure Transmitter (Dpt) At Katpp, Jhalawar
Open Tender
Indian
Rajasthan
Jhalawar
02-08-2023

Tender Details

Supply Of Pressure Transmitter ( Pt ) And Differential Pressure Transmitter ( Dpt ) At Katpp, Jhalawar , Dpt Sh Ist & Ii Nd Stage Flow Tx, Rh Dsh Flow, Blr Cont.Blowdown Flow Unit: Kpa Measuring Range-: -500 To 500 User Range / Calibration Range:0 To 250 , Dpt Drum Level Tx. Unit: Mmh2o Measuring Range-: -800 To 800 User Range / Calibration Range: -600 To500 Mmh2o , Dpt Pa Flow, Aph Pa Inlet & Outlet Dp, Secondary Air Flow, Aph Sa Inlet & Outlet Dp Unit: Kpa Measuring Range-: -2.0 To 2.0 User Range / Calibration Range:0.1 To1.5 , Dpt Feed Control Stn In &Out Dp Unit: Mpa Measuring Range-:- -0.12 To10.0 User Range / Calibration Range:0 To 10.0 , Dpt Sh Spray Water Flow Unit: Kpa, Measuring Range-: -500 To 500 User Range / Calibration Range:0 To 500 , Dpt Rh Spray Water Flow, Main Feedwater Flow Unit: Kpa Measuring Range-:-160 To 160 User Range / Calibration Range:0 To 60 , Dpt Cont.Blowdown Tanklevel Tx Unit: Mmh2o Measuring Range-:-0.0 To 1500 Mmh2o User Range / Calibration Range:0.0 To1500 , Dpt Ldo Tank Level Tx ( Capillary Type ) Unit: Mmh2o Measuring Range-:0 To 8500, User Range / Calibration Range: 0 To 8500 , Dpt Hfo Tank Level Tx ( Capillary Type ) Unit: Mmh2o Measuring Range-: 0 To 13000 User Range / Calibration Range: 0 To 13000 , Pt Furnace Press Tx., Aph Inlet And Outlet Gas Press, Esp Intel Gas Press, Id Fan Inlet Press, Gas Press Fur. Cavity Unit: Kpa, Measuring Range-:-8.0 To 8.0, User Range / Calibration Range: -8.0To1.0 , Pt Main Feedwater Press, Drum Press Tx., Sh Out Press, Main Steam Press, Sh Spray Water Press., Main Feedwater Mov Front Press., Cont. Blowdown Tank Press. Tx Unit: Mpa Measuring Range: -0.1 To 40.0 User Range / Calibration Range: 0 To 30.0 , Pt Secondary Air Pressure Tx., Aph Inlet Sec Air Press, Fd Fan Out Press, Furnace Sec. Air Box Press, Furnace Pressure Unit: Kpa, Measuring Range-: -60 To 60 User Range / Calibration Range: -7.0 To 7.0 , Pt Aph Out Hot Pa Press, Aph Inlet Pa Press , Mill Separator Outlet Pressure , Mill Sealing Air Pressure, Mill Pa Pressure Scanner Air Outlet Pressure Unit: Kpa Measuring Range-:-100 To 400, User Range / Calibration Range:0 To 30.0 , Pt Id Fan Outlet Press Unit: Kpa, Measuring Range-:-2.0 To 2.0 User Range / Calibration Range:0 To 2.0 , Pt Cw / Acw Header Pressure , Instrument Air Pressure, Cw Outlet Pressure Iac / Cac Air Pressure Unit: Mpa, Measuring Range-:0 To 1.5 User Range / Calibration Range:0 To1.5 , Pt Rh Spray Water Press, Ibd Flash Tank Inlet Press. Tx, Turb , Rh Spray Wtr Press Rh Inlet / Outlet Press Unit: Mpa Measuring Range-:-0.1 To 16.0 User Range / Calibration Range:0 To 15.0 , Pt Turbine Stm Prs After Gov Stage1 Unit: Mpa Measuring Range-:0 To 15 User Range / Calibration Range:0 To 15 , Pt No1 Hph I / L Stm Prs Unit: Mpa, Measuring Range-:0 To 10 User Range / Calibration Range:0 To 10 , Pt Hpbp Behind Stm Prs 1, Hp Turb Exhaust Stm Left Prs , Hp Turb Exhaust Stm Right Prs, Hp Turb Exhaust Stm Hdr Pipe Prs , Reater I / L Stm Prs, Crh To Bept Stm Prs, Rh O / L Stm Press , Rh O / L Stm Press , Rh O / L Stm Press , No2 Hph I / L Stm Prs, Crh To Bfpt Stm Prs, Cold Rh Stm To Aux Stm Prs, No 2 Hph I / L Stm Unit: Mpa, Measuring Range-:0 To 6 User Range / Calibration Range: 0 To 6 , Pt Dearator Press 1, 4 Sect. Extr. To Aux Stm Prs, 4 Sect. Extr. To Dea Mov Frt Prs, 4# Extr. To Mfpt Press, Aux Stm To Bfpt Stm Prs., Mfpt A I / L Stm Prs., Aux Stm To Bfpt Stm Prs, Gen Stat Cw I / L Wtr Flow, No5 Lph I / L Stm Prs, Turb Hp&Ip Gas Gland Stm Prs. 1, Gen Entering Hydrogen Pr. No5 Lph I / L Stm Prs Unit: Mpa, Measuring Range-: 0 To 2 User Range / Calibration Range:0 To 2 , Pt Lpbp Vlv ( Hp ) Behind Stm Prs 1 Lpbp Vlv ( Lp ) Behind Stm Prs 1 Unit: Mpa, Measuring Range-:-0.2 To 2 User Range / Calibration Range: -0.1 To 2 , Pt No7 Lph A&B I / L Stm Prs No8 Lph A&B I / L Stm Prs 1 Unit: Mpa Measuring Range-:-0.1 To 0.1 User Range / Calibration Range: -0.1 To 0.1 , Pt Cp Inl Press Unit: Mpa Measuring Range-:-0.1 To 0.5 User Range / Calibration Range: -0.1 To 0.5 , Pt Lub Oil Of Turb Prs Unit: Kpa Measuring Range-: 0 To 5500, User Range / Calibration Range:0 To 5500 , Pt Hp Cond Vacuum Pres 1, Lp Cond Vacuum Press 1, Hp Cond Vacuum Prs 1, Lp Cond Vacuum Prs 1, Bfpt B Exhust Vac Press, Bfpt A Exhust Vac Press Unit: Kpa, Measuring Range-:-100 To 100 User Range / Calibration Range:-100 To100 , Dpt Tdbfbp A I / L Filter Dp, Tdbfbp B I / L Filter Dp Tdbfbd O / L Feed Wtr Flow 2, Tdfpa I / L Filter Dp Tdfp A I / L Filter Dp, Mbfbp I / L Filter Dp, Mbfp I / L Filter Dp, Rh Spray Wtr Flow, Sh Spray Wtr Flow 1, 4# Extr. To Aux Stm Flow, 4# Extr. To Mfpt Unit: Kpa Measuring Range-:-0 To 100 User Range / Calibration Range:0 To 100 , Pt Trub Self-Scanling Gland Htr Prs Unit: Kpa Measuring Range-:-100 To 600 User Range / Calibration Range: -100 To 600 , Dpt Gen Stat Cw Flow, Seal Oil Dp, Hp Bpv In Steam Flow Unit: Kpa Measuring Range-:0 To 250 User Range / Calibration Range:0 To 250 , Dpt Tdbfbp A O / L Feed Wtr Flow 1, Tdbfbp B O / L Feed Wtr Flow 1, Tdbfbp B O / L Feed Wtr Flow 3 Mbfbp O / L Feed Wtr Flow 1 Unit: Kpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 40 , Pt Ldo , Hfo Supply And Return Press ( With Capillary ) Unit: Mpa Measuring Range-:0 To 5 User Range / Calibration Range:0.1 To 5 , Pt Prds Hdr Press Unit: Mpa Measuring Range-:-0 To 6.3 User Range / Calibration Range:0 To 5 , Pt Mill Loading Oil Pressure Unit: Mpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 25 , Dpt Mill Sealing Air Dp Sadc / Cadc Press Dp Unit: Kpa Measuring Range-:-60 To 60 User Range / Calibration Range:0 To 5 , Dpt Hfo Filter Dp ( With Capillary ) Unit: Kpa Measuring Range-: -500 To 500 User Range / Calibration Range: -100 To 100 , Dpt Lo Filter Dp ( With Capillary ) Unit: Kpa Measuring Range-:-160 To 160 User Range / Calibration Range:0 To 100 , Dpt Mill Separotor Inlet / Outlet Dp Unit: Kpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 20 , Dpt Scanner Fan Dp Unit: Kpa Measuring Range-: 0 To 8 User Range / Calibration Range:0 To 6.2 , Pt Scanner Fan Press., Mill Separator Outlet Pressure, Mill Seal Air Pressure, Mill Pa Pressure Unit: Kpa Measuring Range-:-100 To 400 User Range / Calibration Range:0 To 30

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 05-07-2023 NIT EXTENSION ORDER-II Date 19-07-2023
2 19-07-2023 NIT Extension Order IIIrd Date 02-08-2023
3 21-06-2023 CORRIGENDUM-I Date 05-07-2023

Key Value

Document Fees
INR 1180 /-
EMD
INR 100420.0 /-
Tender Value
INR 50.21 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail