| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge..All Kinds of Soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | 1:3:6 (1 Cement: 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) ) |
| 4 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 8 | Suspended floors, roofs, landings, balconies and access platform |
| 9 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 10 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 13 | Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 14 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 15 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia& length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 16 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 17 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry but excluding the cost of nosing of steps etc. complete. |
| 18 | 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement: 4 fine sand) |
| 19 | 12 mm cement plaster of mix: (1 cement: 4 fine sand) |
| 20 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neatcement. 12 mm cement plaster |
| 21 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 22 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 23 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 24 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 |
| 25 | Point wth 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenilic laminated sheet, suitable size M.S> box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 26 | Supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 27 | Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections as required.5/6 amps switch |
| 28 | 3 pin 5/6 A socket outlet |
| 29 | 6 pin 15/16 A socket outlet |
| 30 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover pate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 31 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection / termination with GI thimble etc. as required. |
| 32 | Supplying and fixing brass batten / angle holder including connection etc. as required. |
| 33 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.2 x 2.5 sq.mm + 1 x 2.5 sq.mm. earth wire |
| 34 | 2 x 4 sq.mm + 1 x 4 sq.mm. earth wire |
| 35 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box / wooden block including connections etc. as required. |
| 36 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator.8 way, Double door) |
| 37 | Supplying and fixing 5 A to 32 A rating, 240 /415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole |
| 38 | Double pole |
| 39 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 40 | Supply, Installation, Testing and Commissioning of 1200 mm sweep BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation : B, 3 nos. Blade, 30 cm long down rod, 2 nos, canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS:374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 41 | Supplying, fitting & fixing of 20 W LED LAMP HAVELS MAKE in the existing lamp holder as specified and directed by the department. |
| 42 | Supplying, fitting & fixing of surface and wall mounted LED batten Model BCSB18 WH LUMILINE B 20w BAJAJ make or equivalent future size (L x W x B) (1150x25x40 mm for 20 w) |
| 43 | Supplying with fitting & fixing of 45 W LED road lighting luminaries complete in the existing pole aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughned glass and high power LEDs with secondary optics and IP-66 protection BAJAJ make MAKE ENXT P 54 L WH CR PC SD. |
| 44 | Supplying & laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 3C X 10 sq.mm. 1.1 KV grade AI. Armoured UG cable. |
| 45 | Supplying, fitting & fixing of 1 H.P. centrifugal mono-block motor pump set with necessary connection etc. of Havels make. Model No. CMM 10. |
| 46 | Supplying, fitting & fixing static watt hour meter single phase 220 V, 50 Hz including supplying and fitting required size of meter box, digital meter etc. |
| 47 | Cost of per Kwatt load security to be deposited to APDCL |