}

Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments And Const. Of Pum House At Water Supply Scheme Chakpora Brazloo Of Jal Shakti (Phe) Mechanical Division South Awantipora Under Jjm., Pulwama-Jammu And Kashmir

Government Departments has published Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments And Const. Of Pum House At Water Supply Scheme Chakpora Brazloo Of Jal Shakti (Phe) Mechanical Division South Awantipora Under Jjm.. Submission Date for this Tender is 27-06-2023. Electromechanical Machinery Tenders in Pulwama Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

37490821
Corrigendum : Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments And Const. Of Pum House At Water Supply Scheme Chakpora Brazloo Of Jal Shakti (Phe) Mechanical Division South Awantipora Under Jjm.
Open Tender
Indian
Jammu And Kashmir
Pulwama
27-06-2023

Tender Details

Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments And Const. Of Pum House At Water Supply Scheme Chakpora Brazloo Of Jal Shakti ( Phe ) Mechanical Division South Awantipora Under Jjm.-2 Supply, Installation, Testing & Commissioning Of Open Well Pumping Units As Per Is 14220 At Filter Water Stage. Pump: - • Type Of Pump:Open Wellsubmersible Pump ( Horizontal ) Discharge :10000 Gph, At 30 M Head.• Quality Of Waterto Be Handled :Filter Watermeterial Of Construction:• Pump Casing:Cast Iron• Impeller:Ss • Pump Shaft:Stainless Steel• Motor Body: Cast Iron • Sealing :Dual Mech. Seal ? The Bowl Plate Shall Be Provided With Name Plate Giving Complete Specifications ? Motor: -• Rating : 10 Hp• Method Of Starting: Star – Delta.• Frequency: 50Hz + 3%• Voltage : 415 + 6 %, -15% • Class Of Insulation: Suitable For Above Rating. • Sealing: Dual Mech. Seal.Note: Manufacturers Test Certificate To Be Appended And Detailed Specification As Per Clause 3 Of Sbd ) 3 Fabrication, Providing, Fitting And Lowering Of B Class Column Pipe Conforming To Is: 1239 Of Length 10 Rft Into The 200 / 250 / 300 Mm Casing Dia. Production Well Up To The Desired Depth; The Job Includes Providing And Welding Of Flanges Conforming To Is: 6392, Table-17 And Pn 16 To These Pipes And Welding Of Flanges In Two Layers To Make The Flanged Joint Strong And Leak Proof. Detailed Specification As Per Cluase 7 Ofof Sbd Dn 100B ( Medium ) Pipe 4 Providing / Supplying And Fitting Of G.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class Bconfirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make.Flanges ( As Per Is 6392 / 1997 Table:17 ) Thickness Shall Conform To Is 6392 Part 1St Table-17. Detailed Spacifications As Per Clause 8 Of Sbd.Dn 125B ( Medium ) Pipe 5 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 6 Filling Available Excavated Earth In Trenches, Plinth, Sides Of Foundation Etc.In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Reaming And Watering , Lead Upto 50 M And Lift Upto 1.5M.Quantity : 90% Of Item No: 04 7 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. 8 Fabrication, Providing, Fitting Long Raduisbendout Of 1 Mtr Of Pipe With Length Of1 Ft Each Arm The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Joints. Rest Specification As Per Cluase 15Of Sbd125 Mm 9 Providing And Fitting Of 300Mm In Length 125Mm-100Mm Dia Gi Reducer Bend Flanged On Both Sides, Flange Confirming To Table-17 ( Pn16 ) To Be Fitted With The Column Pipe / Delivery Manifold Of Submersible Pumping Unit To Join Rising Main And Column Pipe / Delivery Manifold.The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes From Inside And Outside Of Pipe To Form Strong Welding Joint. 10 Fabrication, Providing, Fitting T- Junction Out Of 1 Mtr Of Pipe With Length Of1 Ft Each Arm The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Jointsrest Specification As Per Cluase 09Of Sbd 125 Mm 11 Providing And Fitting Of Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .The Body And Bonnent Of The Valve Shall Be Of Ductileiron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positions. Rest Specifications As Per Clause 12 Of Sbd.125 Mm 12 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approved For Drinking Water ) .Rest Specification As Per Cluase 13Of Sbd125 Mm 13 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 14 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation, Drains, Pipes, Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 15 Providing And Laying Of Soling Stone 16 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering . All Work Upto Plinth Level With 1: 2 : 4 Mix ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) 17 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For Foundation , Footings , Bases For Columns 18 Painting Of The 2 No. Gantry And Plate Form Of Wellusing One Coat Of Red Oxide Metal Primer And Two Coats Of Enamel Paintof Different Shades 19 Providing, Installation Andtestingof Manual Type Triple Spur Gear Chain Pulley Block Along With Monorail Gearedtravelling Trolleyhaving Following Features Gears:- The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mounted On Bearings And Housed In A Dust Proof Gear Box. The Lubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears. Load Chain:-The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility.Rest Specification As Per Cluase 24Of Sbd. 20 Fabrication, Providing And Fitting Ofmodularmotor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories Mu-G 15 Rest Spacification As Per Clause 43-------------- Of Sbd 21 Providing, Fitting, Testing And Commissioning Of 25Kva Voltage Stabilizeras Per Specifications Below: Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multi Step.Type Of Regulator: Double Plate Type With Electrolytic Copper Contacts.Input Voltage : 250-400 Volts. ( 3 Phase ) Output Voltage : 400 ±10% Volts.Frequency : 50 ±3 C / S.Windings : Electrolytic Grade Copper Of Adequate Section, Vacuum Impregnated And Oven-Dried.Rest Spacification As Per Clause 44 Of Sbd 22 Providing And Fitting Of 2 Core, 3 Core, 3.5-Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc.Rest Specification As Per Cluase 71Of Sbd.35 Sqmm, 3.5 Core L.T 1.1 Kv 23 Providing And Fitting Of 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. The Main Specification Of The Cable Is Given Below:Rest Specification As Per Cluase 47Of Sbd.Size: 10 Sq.Mm 24 Providing And Fitting Ofpvc Insulated Copper Cable As Per Is 694-Along With Thimbling As Per Requirmentsrest Specification As Per Cluase 67 Of Sbd.16 Sq.Mm 1 Core Lt 1.1 Kv 25 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards. Safe Earthing Electrode Size:80 Mm Dia , Length:2000 Mmback Fill Compound :30 Kg 26 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mm Wide, Thickness 3Mm With 70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.1 ) 3 Way Terminal Connector 20 Amp.2 ) 3 No Mcb 8 Amp. Rest Specification As Per Cluase 50Of Sbd. 27 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36 Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C To 60°Crest Specification As Per Cluase 51Of Sbd. 28 Providing And Installation Of Junction Box With Dp 32 A Mcb To Serve As Main Switch For Led Lighting. The Job Includes Making Of Electric Connection To The Circuit. 29 Providing And Fitting Of 2 Core, 3 Core, 3.5-Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc.Rest Specification As Per Cluase 71Of Sbd.10 Sqmm, 2Core Lt 1.1 Kv 30 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer With Input Voltage 70-240 V And Output 220 V. The Stabilizer Shall Be Installed And Connected To The Electric Circuit As Per Location Provided By Site In Charge. 31 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover.With 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 32 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: -Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 33 Tool Kit For Maintenance: -The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Below Shall Be Ofproviding Of Tool Kit Consists Of Following Items I. Double Ended Spanner ( Chrome Plated ) 02 Sets Complete Ii. Double Ended Ring Spannerschrome Plated02 Sets Completeiii. Allen Key Set Black Finish 02 Sets Complete Iv. Combination Pliers Insulated With Thick C.A Sleeve; Size In Mm 165, 210, 255Each – 02 No.V. Long Nose Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205Each – 02 No. Vi. Side Cutting Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 Make – 02 No.Vii. Insulated Screw Drivers Blade Length In Mmblade Dia. In Mmtip Dimensions In Mm Quantity 50 3 1.6 X 0.4 0275 3 1.6 X0.4 02100 3 3 X 0.4 02125 3.5 3.5 X 0.502 150 3.5 3.5 X 0.5 02 200 4 4 X 0.6 02300 5 5 X 0.8 02Viii. Hammer With Handle Weight – 110 Mg, 340 Gm , 600 Gm –Each – 1No. .Ix. Heavy Duty Pipe Wrench Length In Mm - 200, 300, 600 Each – 01 No.X. Electric Multimeter=1Noxi. Digital Multimeter – 1No. Xii. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xiii. Hack Saw Frame With Hack Saw Blade – 01 No. Xiv. S-16 Mxl, S- 16 H X L Socket Set ( 19 Sockets + 6 Accessories ) – 01 No. 34 Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermo-Cool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks, 35 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 36 Providing Of Bamboo Ladders 18 Feet Long Along With 15 Feet Long Link Rods And Ht Glove Pair ( 01 No Each ) 37 Providing Of 1 Kw Heat Convector For Operators For Winter Season 38 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipment Installed At Site Of Appropriate Sizes. 39 Fabricationof6’ X 6’ Angle Iron Bed By Way Of Providingand Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 40 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 No’S Including Cutting , Fixingall Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 41 Design, Supply, Installation, Testing And Commissioning Of Automatic Power Factor Correctionpanel For Improvement Of Power Factor :Input Voltage= 300-460 Vfrequency=50 ±5% Hz.Ambient Temp.= -10Oc To 40Ocavailable Power Factor= 0.7 - 0.8 Target Power Factor= 0.98 Lagging Switch Time Delay:On Delay= 1-60 Secondsoff Delay=1-60 Seconds Control Type=Binary / Intelligentct Ratio Programming=To Be Provided, Programming Link=To Be Provided, Auto Scroll=To Be Provided, Manual Operation=To Be Provided, Display Parameters=Pf ( Input / Output ) , Kw, Volt, Amps, Relay Contacts= As Per Requirement, Dimensions=Adequate, Bezel / Panel Cut Out=Adequate, System Protection=Ip 55, Enclosure=Modular Crg Sheet, Powder Coated, Mccb Main Protection = As Per Requirement, Mccb ( Individual Protection Of Capacitors ) As Per Requirement 3 No. Note:The Test Certificate Of Each And Every Equipment Fitted In Apfc Panel As Relevant Is, Iec Guide Lines. 42 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase Air Cooled Diesel Generator Set As Per Is 8528 ( 2018 ) And Iso 3046 ( 2002 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size As Per Ministry Of Environment Protection Rule 1986 Read With Latest Amendments. The Dg Set Is Required To Be Fitted And Tested On Load At Sitethe D.G Set Shall Have The Following Technical Specification.Besides The Above Works The D.G Set Shall Be Provided With 12 V, 150 Ah Lead Acid Battery Of Reputed Make Fitted Inside The D.G Set Canopy Along With Necessary Accessories And Battery Charger Of Required Capacity. The Job Also Includes The Cost On Account Of Hsd And Skilled Operator Required For Operation Of D.G Set For A Period Of 10 Hours Continuously During Its Testing And Commissioning Of D.G Set At Site. The Capacity Of The D.G Set Is Given Below:Rating: 25 Kva Dg Set 43 Supply, Installation, Commissioning And Creation Of Pole Mounted, Outdoor Type Electric Sub Station As Per The Technical Specifications Given Here Under -Specifications Conforming To Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Type: Ht / Lt Transformer Type Of Cooling:Onan. Operating Conditions:Input=11000 Volts Output =433 Volts Ac Supply In 3- Phase.Terminals: Input=3 No. Ht Bush Rods With Insulators, Washer, Nuts Etc.Output=4 No. Lt Bush Rods Switch Insulators, Washers, Nuts Etc.Core: The Core Shall Be Of High Permeability To Reduce Core Losses And The Strips Shall Be Of Suitable Size And Gauge. Transformer Coils: Suitable Number Of Ht And Lt Coils In Each Leg Of The Core. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips, Properly Wound. The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shall Be Of Reputed Make From An Iso Certified Company As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Be Provided With Breather Fill With Silica Jel Crystals, Conservator With Oil Level Indicator, Explosion Vet And Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessary Inspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate.Rating: 63 Kva 44 Providing And Fittingg.I Channel / Angle / Flat Of Sizes Including Clamps 45 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Ofht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 46 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Set Horn Gap 3-Phase 200 A Suitable For Vertical Installation 47 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestor Station Class, 10Ka, 9Kv, La With Polymer Housing, Station Type 48 Supply And Fitting Of 11 Kv Polymeric Composite Pin Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creepagedistance 320 Mm 49 Supply, Installation, Erection Of 9 Mtrs Longh.T Pope Of Specifications St- 410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 50 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement 51 Earth Work In Excavation By Manual Means In Trenches For Foundation, Drains, Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed.All Kinds Of Soil 52 Providing And Laying Of Soling Stone Including Manual Compaction 53 Concrete Cement Bottoming 1:2:4 Mix As Per Rec Standards , 0.5 Cum / Pole 54 P / F Danger Plate With Clamps 55 Providing And Fixing G.I Barbed Wire For Anti-Climbing / Anti-Climbing Devices 56 Providing And Fitting Of Pg Clamps 57 Providing And Fixinganti-Climbing Devices 58 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts, 2 N0- Turn Buckle, 1.8 M Long, 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete. 59 Painting Of Poles Red Oxide 60 Painting Of Poles Aluminum Paint 61 Providing And Fitting Of Acsr As Per Is 398 ( Part-2 ) 1996 For 50 Sq.Mmacsr ( Galvanised Steel Reinforced ) For Fitment Of Various Accessories 62 Supply, Installation, Testing Of 35 Sq Mm Xlpe Ht Cable ( Abc Type ) Of 11 Kv Grade With Following Specifications Size Cross Sectional Area In Squre Mm ) =3X35 Phases Red, Yellow , Blue 63 P / F Of 11 Kv Cable Termination Kit For Connecting 35 Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 64 Providing And Fitting Of Lt Distribution Box For H.T Transformer With Mccb For Incomer And Sfu For Outgoing Circuits. 63 Kva 65 ( Part B ) Pump House Of Wss Chakpora Brazloo ( Adv. Cost Rs. 21, 29, 000 / - ) 66 Earth Work In Excavation Over Areas Exceeding 30 Cm And Upto 1.5 M In Depth 1.5 M In Width As Well As 10 Sqm On Plan Inculding Disposal Of Excavated Soil Upto1mt From Cutting Edge. 67 Extra For Earth Work For Every Additional Lift Of 1.5 M Or Part Thereof 68 Providing And Laying Of Dry Stones Soling Tightly Hand Packed. 69 Provding And Laying Of 1:4:8 Nominal Mix Cement Concrete With 40 Mm N / S Stone Aggregate 70 R.R Masonary With Quarry Stone Laid In 1:6 Cm 71 R.R Masonary With Quarry Stone Laid In 1:6 Dry 72 Providing And Laying Of 50 Mm Thick Dp Band Over Stone Work In 1:2:4 Nominal Mix 73 Pointing On Stone Work With Cement Mortar In 1:3 Mix ( Flush Type ) 74 Brick Work With Ommon Brunt Clay F.P.S Bricks Of Class Designation 75 In Foundation And Plinth In 1:6 Cm. 75 Extra Over Brick In Super Structure Up To Floor V Level. 76 Providing And Fixing Of Wooden Chowkat In First Class Kail Wood. 77 Providing And Fixing Of 35Mm Thick Glazed Shutters For Doors And Windows First Class Kail Wood. 78 Providing And Fixing Panelled Or Panelled Andglazed Shutters For Doors And Windows 35Mm Thick Of Kail Wood. 79 Providing And Fixing Of Panelling Or Penelling And Glazing In Panelled Or Panelledand Glazed Shutters For Doors And Windows ; Penelling 25Mm To 40Mm Thick Of Kail Wood. 80 Providing And Fixing Of 35Mm Thick Wire Guage Shutters For Doors And Windows. 81 Reinforced Cement Concrete Work In 1:2:4 Nominal Mix With 20Mm N / S Stone Aggregate. 82 Providing Reinforcement To The Rcc Works Including Bending, Binding, Cutting Placing In Position Complete. 83 Centering And Shuttering Including Proping, Struting Etc And Removal Of Farm Work.Lintel / V Beam 84 Slab 85 Slab Edges 86 Providing 50Mm Thick Cement Concrete Flouring With Floating Coat Of Neat Cement. 87 12Mm Thick Cement Sand Plaster In 1:4 Mix 88 1:3 Mix With Floating Coat Of Neat Cementfor Saptic Tank. 89 Providing And Fixing 1St Quality Ceramic Glazed Tiles With Minimum Thickness 5Mm Of Approved Make Like Kajaria, Somany Etc. Over 12Mm Thick Cement Mortar In 1:3 Mix. 90 Providing And Laing / Fixing Ceramic Glazed Floor Tiles 300X300mm Of 1St Class Of Somany Or Kajaria Or Equilent Made Laid On 20Mm Thick Bed Of Lcement Mortar In 1:4 Mix. 91 Providing And Fixing Water Closet Squarting Pan ( Indian Type With 100Mm Sand Cast Iron P Or S Trap, 10 Lit, Low Level Pvc Flusingcistern Including Flushing Pipe And Making Good The Walls And Floors Wherever Required ( Orrisa Pattern With Intergral Foot Type ) . 92 Providing And Fixing Salem Stainless Steel Kitched Sink. Size 610X510x200mm 93 Providing And Fixing Of Pvc Wasit Pipe Sink Including Pvc Waist Fititng Complete ( Flexable 40 Mm Dia = 1 No ) 94 Providing And Fixing Of Sanitary Fititng ( Ls ) 95 Structual Steel Works Welded In Built Up Section, Trusses And Framed Works Including Cutting Hoisting, Fixing In Position And Applying Priming Coat Of Approved Steel Primer Complete. 96 Providing And Fixing Corrogated G.S Sheets Including Vertical / Curved Surfaces With Polymer Coated J Or L Hooks ( 0.50 Mm Thick ) 97 Proving Ridge Or Hip Of Width 60Cm Over All With Plain Gs Sheets Fixed With Polymer Coated J Or L Hoors ( 0.50 Mm Thick ) 98 Providing And Fixing Of Ms Eves Boarding 300 Mm Wide And Soffit Boarding Including Priming Coat Of Red Oxide And Painting With Two Or More Coats With Synthetic Paint Of Approved Brand And Manufacture Complete Job 99 Providing And Applying White Cement Based Putty Of Approved Thickness 1Mm Of Approved Brand And Manufacture Over The Plastered Surfaces To Prepare The Surface Smooth And Even Complate. 100 Distempering Lwith 1St Quality Acrylic Distemper Of Approvedbrand And Manufacture Including Applyingadditional Lcoats Whereever Required To Achive Even Shade. ( Two Coats ) 101 Finishing Walls With Water Proofing Cement Paint Of Required Shade ( External ) ( Snowsum ) 102 Painting With Synthetic Enamal Paint Ofapproved Brand And Manufacture Of Required Colour To Give Even Shade Two Or More Coats On New Work Lincludingpriming Coat Of Approved Brand And Manufacture.Wood Works 103 Add. Provision For Plumbing , Iron Grills To Windows And Electrification To The Quarter Lump Sum To Be Paid As Per Actual ( L.S ) 104 Carriage Of Material From Source To Dumping Site At Road By Mechanical Transport A ) Cement And Steel For Average Lead Of 20 ( Km ) 105 B ) Sand For Average Lead Of 25 ( Km ) 106 C ) 20Mm Aggregate For Average Lead Of 27 ( Km ) 107 D ) 40Mm Aggregate For Average Lead Of 27 ( Km ) 108 E ) Bricks For Average Lead Of10 ( Km ) 109 F ) Quarry Stone For Average Lead Of15 ( Km ) 110 G ) Soling Stone For Average Lead Of06 ( Km ) 111 Head Load Of Material From Dumping Site To Actual Work Site For Average Lead Of.A ) Cementfor Average Lead Of 600 ( Mts ) 112 B ) Steel For Average Lead Of 600 ( Mts ) 113 C ) Sand & 20Mm Agg. For Average Lead Of600 ( Mts ) 114 D ) 40Mm Agg. For Average Lead Of600 ( Mts ) 115 E ) Bricks For Average Lead Of 600 ( Mts ) 116 F ) Quarry Stone For Average Lead Of600 ( Mts ) 117 G ) Soling Stone For Average Lead Of 600 ( Mts )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-06-2023 Extension Notice IV Date 19-06-2023
2 13-05-2023 Extension Notice Date 22-05-2023
3 20-06-2023 Extension Notice V Date 27-06-2023
4 23-05-2023 Extension Notice II Date 29-05-2023
5 30-05-2023 Extension Notice III Date 09-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 88100.0 /-
Tender Value
INR 44.05 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail