Tender For Execution Of Various Maintenance Works As Per Requirement Within The Jurisdiction Of Electric Division Kulgam.- 1 Supply, Erection, Testing & Commissioning Of S.T Pole 11Mtr. Long Sp-56 With Base Plate & Cap For Ht. Strictly As Per Rec Standards 2 Erection, Testing & Commissioning Of S.T Pole 11Mtr. Long Sp-56 Including Its Carriage From Divisisonal Store To Site 3 Supply, Erection, Testing & Commissioning Of S.T Pole 9Mtr Long Sp-33 With Base Plate & Cap For Ht. Strictly As Per Rec Standards 4 Erection, Testing & Commissioning Of S.T Pole 9Mtr Long Sp-33Including Its Carriage From Divisisonal Store To Site 5 Supply, Erection, Testing & Commissioning Of S.T Pole 8Mtr Long Sp-15 With Base Plate & Cap For Lt. Strictly As Per Rec Standards 6 Erection, Testing & Commissioning Of S.T Pole 8Mtr Long Sp-15Including Its Carriage From Divisisonal Store To Site 7 Supply, Erection, Testing & Commissioning Of Pcc Pole 8Mtr Long 8 Erection, Testing & Commissioning Of Pcc Pole 8Mtr Longincluding Its Carriage From Divisisonal Store To Site 9 Supply, Laying, Stringing, Tensioning & Binding Of Acsr 100Mmsq ( Dog ) Conductor 10 Laying, Stringing, Tensioning & Binding Of Acsr 100Mmsq ( Dog ) Conductorincluding Its Carriage From Divisisonal Store To Site 11 Supply, Laying, Stringing, Tensioning & Binding Of Acsr 50Mmsq ( Rabbit ) Conductor 12 Laying, Stringing, Tensioning & Binding Of Acsr 50Mmsq ( Rabbit ) Conductorincluding Its Carriage From Divisisonal Store To Site 13 Supply, Laying, Stringing, Tensioning & Binding Of Acsr 30Mmsq ( Weasal ) Conductor 14 Laying, Stringing, Tensioning & Binding Of Acsr 30Mmsq ( Weasal ) Conductorincluding Its Carriage From Divisisonal Store To Site 15 Providing & Fixingof Ismc 100X50x6mm Channel Iron Cross Arms For X-Mer Frame 8Long @ 22.4 Kg Each -1 Noincluding Nuts & Bolts 16 Fixing Of Ismc 100X50x6mm Channel Iron Cross Arms For X-Mer Frame 8Long 17 Providing & Fixing Of Ismc 75X40x6mm Channel Iron Cross Arms For X-Mer Frame- 1 Nos @16.5 Kg Each 8 Long Including Nuts & Bolts 18 Fixing Of Ismc 75X40x6mm Channel Iron Cross Arms For X-Mer Frame- 19 Providing , Fixing, Ofismc 75X40x6mm X-Arm 5 Long 20 Fixing, Ofismc 75X40x6mm X-Arm 5 Long- 21 Providing , Fixing, Of Ms Angle Iron Braces 50X50x6mm-4.5 Ft Long, 22 Fixing, Of Ms Angle Iron Braces 50X50x6mm-4.5 Ft Long 23 Supplying And Fixing Of Pole Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20 Mm 2.5 Mtr Long Through Gi Strip ( 25X3 Mm ) Forht / Lt Pole 24 Fixing Of Pole Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20 Mm 2.5 Mtr Long Through Gi Strip ( 25X3 Mm ) Forht / Lt Pole 25 Providing And Fixing Ofsprial Earthing Made Of 115 Turns Of Gi Wire Swg No.8Placed 1.5M Below Ground Level Including Excavation Of Pit, Refilling The Same Withsoft Soil 26 Fixing Ofsprial Earthing Made Of 115 Turns Of Gi Wire Swg No.8Placed 1.5M Below Ground Level Including Excavation Of Pit, Refilling The Same Withsoft Soil 27 Supply, Fixing, Testing & Commissioning Of 11Kv Link Set ( Polymer ) Station Type As Per Is Standards 28 Fixing, Testing & Commissioning Of 11Kv Link Set Station Type ( Polymer / Porcelain ) As Per Is Standards 29 Supply, Fixing, Testing & Commissioning Of 11Kv Link Set Heavy Duty As Per Is Standards 30 Fixing, Testing & Commissioning Of 11Kv Link Set Heavy Duty ( Polymer / Porcelain ) As Per Is Standards 31 Supply, Fixing, Testing & Commissioning Of 11Kv Do Fuse Set ( Polymer ) As Per Is Standards 32 Fixing, Testing & Commissioning Of 11Kv Do Fuse Set ( Polymer / Porcelain ) As Per Is Standards 33 Supply, Fixing, Testing & Commissioning Of 11Kv La Set ( Polymer ) As Per Is Standards 34 Fixing, Testing & Commissioning Of 11Kv La Set ( Polymer / Porcelain ) As Per Is Standards 35 Supply, Fixing, Testing & Commissioning Of Lt Fuse Set 36 Supply, Fixing, Testing & Commissioning Of 11Kv Discset ( Polymer ) 45 Kncomplete Set 37 Supply, Fixing, Testing & Commissioning Of 11Kv Discset ( Porcelain ) 45 Kncomplete Set 38 Fixing, Testing & Commissioning Of 11Kv Disc Set ( Polymer / Porcelain ) 45 Kncomplete Set 39 Supply, Fixing, Testing & Commissioning Of 11Kv Pin ( Polymer ) Insulators 45 Kn With Gi Pins Complete. 40 Supply, Fixing, Testing & Commissioning Of 11Kv Pin Insulators ( Porcelain ) 45 Kn With Gi Pins Complete. 41 Fixing, Testing & Commissioning Of 11Kv Pin Insulators ( Polymer / Porcelain ) 45 Kn With Gi Pins Complete. 42 Carriage, Installation, Testing & Commisioing Of 16 / 25 Kva11 / 0.433 Kv 3-Phase Dully Oil Filled Distribution Transformer From Divisional Stores Upto Site Within The Jurisdiction Of Ed Kulgam 43 Carriage, Installation, Testing & Commisioing Of 16 / 25 Kva11 / 0.433 Kv 3-Phase Dully Oil Filled Distribution Transformer From Divisional Stores Upto Site Within The Jurisdiction Of Ed Kulgam 44 Carriage, Installation, Testing & Commisioing Of 63 / 100 Kva11 / 0.433 Kv 3-Phase Dully Oil Filled Distribution Transformer From Divisional Stores Upto Site Within The Jurisdiction Of Ed Kulgam 45 Carriage, Installation, Testing & Commisioing Of 63 / 100 Kva11 / 0.433 Kv 3-Phase Dully Oil Filled Distribution Transformer From Divisional Stores Upto Site Within The Jurisdiction Of Ed Kulgam 46 Carriage, Installation, Testing & Commisioing Of 200 / 250 / 300 Kva11 / 0.433 Kv 3-Phase Dully Oil Filled Distribution Transformer From Divisional Stores Upto Site Within The Jurisdiction Of Ed Kulgam 47 Carriage, Installation, Testing & Commisioing Of 200 / 250 / 300 Kva11 / 0.433 Kv 3-Phase Dully Oil Filled Distribution Transformer From Divisional Stores Upto Site Within The Jurisdiction Of Ed Kulgam 48 Carriage, Installation, Testing & Commisioing Of 400 / 500 / 630 Kva11 / 0.433 Kv 3-Phase Dully Oil Filled Distribution Transformer From Divisional Stores Upto Site Within The Jurisdiction Of Ed Kulgam 49 Carriage, Installation, Testing & Commisioing Of 400 / 500 / 630Kva11 / 0.433 Kv 3-Phase Dully Oil Filled Distribution Transformer From Divisional Stores Upto Site Within The Jurisdiction Of Ed Kulgam 50 Providing & Fixing Of Thimbles 95 Mm Sq. Of Standard Make 51 Fixing Of Thimbles 95 Mm Sq. Of Standard Make 52 Providing & Fixing Of Thimbles 120 Mm Sq. Of Standard Make 53 Fixing Of Thimbles 120 Mm Sq. Of Standard Make 54 Providing & Fixing Of Thimbles 185 Mm Sq. Of Standard Make 55 Fixing Of Thimbles 185 Mm Sq. Of Standard Make 56 Providing & Fixing Of Thimbles 240 Mm Sq. Of Standard Make 57 Fixing Of Thimbles 240 Mm Sq. Of Standard Make 58 Providing & Fixing Of Thimbles 300 Mm Sq. Of Standard Make 59 Fixing Of Thimbles 300 Mm Sq. Of Standard Make 60 Providing & Fixing Of Thimbles 400 Mm Sq. Of Standard Make 61 Fixing Of Thimbles 400 Mm Sq. Of Standard Make 62 Providing & Fixing Of Soldress Clamp 95 Mm Sq. Of Standard Make 63 Fixing Of Soldress Clamp95 Mm Sq. Of Standard Make 64 Providing & Fixing Of Soldress Clamp120 Mm Sq. Of Standard Make 65 Fixing Of Soldress Clamp 120 Mm Sq. Of Standard Make 66 Providing & Fixing Of Soldress Clamp185 Mm Sq. Of Standard Make 67 Fixing Of Soldress Clamp 185 Mm Sq. Of Standard Make 68 Providing & Fixing Of Soldress Clamp 240 Mm Sq. Of Standard Make 69 Fixing Of Soldress Clamp 240 Mm Sq. Of Standard Make 70 Providing & Fixing Of Soldress Clamp 300 Mm Sq. Of Standard Make 71 Fixing Of Soldress Clamp 300 Mm Sq. Of Standard Make 72 Providing & Fixing Of Soldress Clamp 400 Mm Sq. Of Standard Make 73 Fixing Of Soldress Clamp 400 Mm Sq. Of Standard Make 74 Providing, Fixing Of Gi Nuts And Bolts For Fixing Of X-Arms And Other Accessories. 75 Fixing Of Nuts And Bolts For Fixing Of X-Arms And Other Accessories. 76 Painting Of Poles With One Coat Of Red Oxide And Two Coats Of Alm Paint. Complete Job Icluding The Cost Of Paint And Red Oxide 77 Supply, Fixing, Of Lt Shackle Insuators With D-Clamps And Nuts Bolts. 78 Fixing, Of Lt Shackle Insuators With D-Clamps And Nuts And Bolts. 79 Supply, Fixing, Of Lt Shackle Insuators With Mukhi-Clamps Nuts And Bolts. 80 Fixing, Of Lt Shackle Insuators With Mukhi-Clamps Nuts And Bolts. 81 Dismentalling Of St 8Mtr Long Poles Including Its Carriage To Divisional Storeskulgam ( Complete Job ) 82 Dismentalling Of St 9Mtr Long Poles Including Its Carriage To Divisional Storeskulgam ( Complete Job ) 83 Dismentalling Of St 11Mtr Long Poles Including Its Carriage To Divisional Storeskulgam ( Complete Job ) 84 Dismentalling Of Pcc Poles Including Its Carriage To Divisional Storeskulgam ( Complete Job ) 85 Dismentalling & Re-Erection Of Pcc Poles 86 Dismentalling & Re-Erection Of St 8Mtr. Longpoles 87 Dismentalling & Re-Erection Of St 9Mtr. Long Poles 88 Dismentalling & Re-Erection Of St 11Mtr. Longpoles 89 Dismentalling Of Acsr 30Mmsq Including Its Carriage To Divisional Storeskulgam ( Complete Job ) 90 Dismentalling Of Acsr 50Mmsq Including Its Carriage To Divisional Storeskulgam ( Complete Job ) 91 Dismentalling Of Acsr 100Mmsqincluding Its Carriage To Divisional Storeskulgam ( Complete Job ) 92 Dismentalling & Re-Layingof Acsr 30Mmsq At Site 93 Dismentalling & Re-Layingof Acsr 50Mmsq At Site 94 Dismentalling & Re-Layingof Acsr 100Mmsq At Site 95 Re-Stringing Of Loose Conductor ( 50Mmsq ) 96 Re-Stringing Of Loose Conductor ( 30Mmsq ) 97 Re-Stringing Of Loose Conductor ( 100Mmsq ) 98 Branch Cutting Of Trees For Route Clearance For Minimising Frquency Of Faults. 99 Unloadingof 16Kva / 25Kvadistribution Transformer 100 Loading Of 16Kva / 25Kvadistribution Transformer 101 Unloadingof 63Kva / 100Kvadistribution Transformer 102 Loading Of 63Kva / 100Kvadistribution Transformer 103 Unloadingof 200Kva / 250Kva / 300Kvadistribution Transformer 104 Loadingof 200Kva / 250Kva / 300Kvadistribution Transformer 105 Unloadingof 400Kva / 500Kva / 630Kvadistribution Transformer 106 Loadingof 400Kva / 500Kva / 630Kvadistribution Transformer 107 Straightening Of Tilted St Poles ( 11Mtr / 9Mtr / 8Mtr. ) 108 Unloading Of St 11Mtr / 9Mtr / 8Mtr. Long Poles In Divisional Stores 109 Loading Of St 11Mtr / 9Mtr / 8Mtr. Long Poles In Divisional Stores 110 Supply And Fixing Of Earthing Of Sub Station-Excavation Of Earth Pit Of Dia 650 Mm & Depth 3000Mm, Installation Of Earthing Pipe Of 40Mm Nominal Bore And 4Mm Wall Thickness And Length 2.5 Mtr Long As Per Is 1239 Gi Strip For Neutral Earthing Of Size25x3mm For Connection Of Transformer Body, Go Set And Lighting Arrestor As Per Is 2629 / 85, Gi Nuts And Bolts, Refilled With Earth Enhancement Material And Earth Chamber Made Of Brick Masonary With Rcc Slab Cover. 111 Supply And Fixing Of Galvanised Stay Set With 50 X 8 Mm Stay Clamp, Guy Insulator ( 02 No. ) , Anchor Plate ( 200X200x6 Mm ) , Nuts And Bolts , 2 No. Turn Buckles , 1.8 Mm Long , 16Mm Dia Solid Gs Stay Rod And 7 / 3.15 Mm Dia Gi Stranded Wire Complete 112 Fixing Of Galvanised Stay Set With 50 X 8 Mm Stay Clamp, Guy Insulator ( 02 No. ) , Anchor Plate ( 200X200x6 Mm ) , Nuts And Bolts , 2 No. Turn Buckles , 1.8 Mm Long , 16Mm Dia Solid Gs Stay Rod And 7 / 3.15 Mm Dia Gi Stranded Wire Complete 113 Supply, Installation , Testing & Commissioning Of Gapless Surge Arrestor, 9 Kv, 10 Ka, La With ( Polymer ) Housing, Station Type 114 Installation , Testing & Commissioning Of Gapless Surge Arrestor, 9 Kv, 10 Ka, La With ( Polymer ) Housing, Station Type 115 Supply, Installation , Testing & Commissioningof 11 Kv, G.O Ab Switch , 3-Phase, 200A 116 Installation , Testing & Commissioning Of 11 Kv, G.O Ab Switch , 3-Phase, 200A 117 Supply, Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 50 Sq Mm 118 Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 50 Sq Mm 119 Supply, Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 70 Sq Mm 120 Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 70 Sq Mm 121 Supply, Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 120 Sq Mm 122 Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 120 Sq Mm 123 Supply, Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 185 Sq Mm 124 Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 185 Sq Mm 125 Supply, Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 240 Sq Mm 126 Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 240 Sq Mm 127 Supply, Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 300 Sq Mm 128 Installation , Testing & Commissioning Of Un Armoured Single Core Xple, Frls Cable 300 Sq Mm 129 Supply And Laying Of Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5 Cum / Pole, Muffing 20 Cm Above Ground Level , Including Plaster And Curing Of Concrete. 130 Supply And Laying Of Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.45 Cum / Pole, Muffing 20 Cm Above Ground Level , Including Plaster And Curing Of Concrete. 131 Providing, Installation, Testing & Commisioning Of 3-Phase 4-Wire Prodigy Meter ( 40 -200A ) , Including Suitable Stand / Clamps Using Channels And Canopy To Protect The Same From Adverse Weather Conditions ( Complete ) 132 Installation, Testing & Commisioning Of 3-Phase 4-Wire Prodigy Meter ( 40 -200A ) , Including Suitable Stand / Clamps Using Channels And Canopy To Protect The Same From Adverse Weather Conditions ( Complete ) 133 Providing, Installation, Testing & Commisioning Of Single Phase Energy Meterincluding Suitable Clamps Nuts And Bolts ( Complete ) 134 Installation, Testing & Commisioning Of Single Phase Energy Meterincluding Suitable Clamps Nuts And Bolts ( Complete ) 135 Providing, Installation, Testing & Commisioning Of Three Phase Energy Meterincluding Suitable Clamps Nuts And Bolts ( Complete ) 136 Installation, Testing & Commisioning Of Three Phase Energy Meterincluding Suitable Clamps Nuts And Bolts ( Complete ) 137 Supply, Laying, Testing & Commissiong Of 35Mmsq Ab ( Ht Cable ) ( 3X35+1X35mmsq ) Xlpe ( 11Kv , 3 X 1Core + Earth ) Of Standard Make Conforming To Is; 8130-1894, Is; 398 ( Part-Iv ) - 1994, Is:7098 ( Part Ii ) - 2011 & Is; 5831-1984 With Upto Date Amendments If Any. 138 Laying, Testing & Commissiong Of 35Mmsq Ab ( Ht Cable ) ( 3X35+1X35mmsq ) Xlpe ( 11Kv , 3 X 1Core + Earth ) Of Standard Make Conforming To Is; 8130-1894, Is; 398 ( Part-Iv ) - 1994, Is:7098 ( Part Ii ) - 2011 & Is; 5831-1984 With Upto Date Amendments If Any. 139 Supply, Laying, Testing & Commissiong Of 50Mmsq Ab ( Ht Cable ) ( 3X50+1X70mmsq ) Xlpe ( 11Kv , 3 X 1Core + Earth ) Of Standard Make Conforming To Is; 8130-1894, Is; 398 ( Part-Iv ) - 1994, Is:7098 ( Part Ii ) - 2011 & Is; 5831-1984 With Upto Date Amendments If Any. 140 Laying, Testing & Commissiong Of 50Mmsq Ab ( Ht Cable ) ( 3X50+1X70mmsq ) Xlpe ( 11Kv , 3 X 1Core + Earth ) Of Standard Make Conforming To Is; 8130-1894, Is; 398 ( Part-Iv ) - 1994, Is:7098 ( Part Ii ) - 2011 & Is; 5831-1984 With Upto Date Amendments If Any. 141 Supply, Laying, Testing & Commissiong Of 70Mmsq Ab ( Ht Cable ) ( 3X70+1X95mmsq ) Xlpe ( 11Kv , 3 X 1Core + Earth ) Of Standard Make Conforming To Is; 8130-1894, Is; 398 ( Part-Iv ) - 1994, Is:7098 ( Part Ii ) - 2011 & Is; 5831-1984 With Upto Date Amendments If Any. 142 Laying, Testing & Commissiong Of 70Mmsq Ab ( Ht Cable ) ( 3X70+1X95mmsq ) Xlpe ( 11Kv , 3 X 1Core + Earth ) Of Standard Make Conforming To Is; 8130-1894, Is; 398 ( Part-Iv ) - 1994, Is:7098 ( Part Ii ) - 2011 & Is; 5831-1984 With Upto Date Amendments If Any. 143 Supply, Laying, Testing & Commissiong Of 120Mmsq Ab ( Ht Cable ) ( 3X120+1X95mmsq ) Xlpe ( 11Kv , 3 X 1Core + Earth ) Of Standard Make Conforming To Is; 8130-1894, Is; 398 ( Part-Iv ) - 1994, Is:7098 ( Part Ii ) - 2011 & Is; 5831-1984 With Upto Date Amendments If Any. 144 Laying, Testing & Commissiong Of 120Mmsq Ab ( Ht Cable ) ( 3X120+1X95mmsq ) Xlpe ( 11Kv , 3 X 1Core + Earth ) Of Standard Make Conforming To Is; 8130-1894, Is; 398 ( Part-Iv ) - 1994, Is:7098 ( Part Ii ) - 2011 & Is; 5831-1984 With Upto Date Amendments If Any. 145 Supply, Laying, Testing & Commissiong Of 120Mmsq Ab ( Lt Cable ) ( 3X120+1X16+1X70mmsq ) Of Standard Make . 146 Laying, Testing & Commissiong Of 120Mmsq Ab ( Lt Cable ) ( 3X120+1X16+1X70mmsq ) Of Standard Make . 147 Supply, Laying, Testing & Commissiong Of 70Mmsq Ab ( Lt Cable ) ( 3X70+1X16+1X50mmsq ) Of Standard Make . 148 Laying, Testing & Commissiong Of 70Mmsq Ab ( Lt Cable ) ( 3X70+1X16+1X50mmsq ) Of Standard Make . 149 Supply, Laying, Testing & Commissiong Of 50Mmsq Ab ( Lt Cable ) ( 3X50+1X16+1X35mmsq ) Of Standard Make . 150 Laying, Testing & Commissiong Of 50Mmsq Ab ( Lt Cable ) ( 3X50+1X16+1X35mmsq ) Of Standard Make . 151 Supply, Fixing, Testing & Commissiong Of Mid Span Straight Through Jointing Kit For 11Kv Ab Cable Suitable Forab Cableof Standard Make And Size Conforming To The Latest Is Standards 152 Fixing, Testing & Commissiong Of Mid Span Straight Through Jointing Kit For 11Kv Ab Cable Suitable Forab Cableof Standard Make And Size Conforming To The Latest Is Standards 153 Supply, Fixing, Testing & Commissiong Of 11Kv Heat Shrinkable Out Door Cable Termination Kit For 11Kvab Cable Of Standard Make And Size Conforming To The Latest Is Standards 154 Fixing, Testing & Commissiong Of 11Kv Heat Shrinkable Out Door Cable Termination Kit For 11Kvab Cable Of Standard Make And Size Conforming To The Latest Is Standards 155 Supply, Fixing Of Suspension Clamps With Eye Hook ( Complete ) Of Standard Make For Ab Cable Including Strips For Fixing On Polesof Required Sizes 156 Fixing Of Suspension Clamps With Eye Hook ( Complete ) Of Standard Make For Ab Cable Including Strips For Fixing On Polesof Required Sizes 157 Supply, Fixing Of Dead End Clamps ( Complete ) Of Standard Make Forab Cable Including Strips For Fixing On Poles Of Required Sizes 158 Fixing Of Dead End Clamps ( Complete ) Of Standard Make Forab Cable Including Strips For Fixing On Poles Of Required Sizes 159 Supply, Installation , Testing And Commissioning At Sites Within The Jurisdiction Ofedkulgam ( By Utilizingskilled Mechanics ) Of 2.8Kva Portable Gensets On Hire Basis 160 Supply, Installation , Testing And Commissioning At Sites Within The Jurisdiction Of Edkulgam ( By Utilizingskilled Mechanics ) Of 2.8Kva Portable Gensets On Hire Basis 161 Loading, Carriage To And Fro , Installation , Testing And Commissioning ( By Utilizingskilled Mechanics ) Of 2.8Kva Portable Gensets ( To Be Provided By The Department ) From Divisional Stores Upto Sites Within The Jurisdiction Of Ed Kulgam 162 Loading, Carriage To And Fro , Installation , Testing And Commissioning ( By Utilizingskilled Mechanics ) Of 2.8Kva Portable Gensets ( To Be Provided By The Department ) From Divisional Stores Upto Sites Within The Jurisdictionof Edkulgam 163 Operation And Maintainence ( By Utilizingskilled Mechanics ) Of 2.8Kva Portable Gensets 164 Loading, Carriage To And Fro , Installation , Testing And Commissioning ( By Utilizingskilled Mechanics ) Of 25 Kva Portable Gensets ( To Be Provided By The Department ) From Divisional Stores Upto Sites Within The Jurisdiction Of Ed Kulgam 165 Loading, Carriage To And Fro , Installation , Testing And Commissioning ( By Utilizingskilled Mechanics ) Of 25 Kva Portable Gensets ( To Be Provided By The Department ) From Divisional Stores Upto Sites Within The Jurisdictionof Edkulgam 166 Operation And Maintainence ( By Utilizingskilled Mechanics ) Of 25 Kva Portable Gensets 167 Installation, Testing & Commisioing Of 70Watt Led Lights Including Their Back Carriage To The Divisional Stores From The Site ( To Be Provided By Department ) 168 Supply, Installation, Testing & Commisioing Of 40Watt Led Lights Including Providing Bracket , Clamps , Nuts & Bolts Of Standard Make 169 Installation, Testing & Commisioing Of 40Watt Led Lights Includingbracket , Clamps , Nuts & Bolts Of Standard Make 170 Supply, Installation, Testing & Commisioing Of 5Watt Led Bulb Of Standard Make 171 Supply, Installation, Testing & Commisioing Of 7Watt Led Bulb Of Standard Make 172 Supply, Installation, Testing & Commisioing Of 9Watt Led Bulb Of Standard Make 173 Supply, Installation, Testing & Commisioing Of 10Watt Led Bulb Of Standard Make 174 Supply, Installation, Testing & Commisioing Of 15Watt Led Bulb Of Standard Make 175 Supply, Installation, Testing & Commisioing Of 20Watt Led Bulb Of Standard Make 176 Providing, Laying Of 16Mmsq Twin Core Aluminuim Conductor Frls 177 Providing, Laying Of 10Mmsq Twin Core Aluminuim Conductor Frls 178 Providing, Laying Of 6Mmsq Twin Core Aluminuim Conductor Frls 179 Providing, Laying Of 1Mmsq Multicore Cu Flexible Wire Of Standard Make 180 Providing, Laying Of 1.5Mmsq Multicore Cu Flexible Wire Of Standard Make 181 Providing, Laying Of 2.5Mmsq Multicore Cu Flexible Wire Of Standard Make 182 Providing, Laying Of 4Mmsq Multicore Cu Flexible Wire Of Standard Make 183 Providing, Laying Of 6Mmsq Multicore Cu Flexible Wire Of Standard Make 184 Supply, Installation, Testing & Commisioing Of 5Amp Switch Socket Combine 185 Supply, Installation, Testing & Commisioing Of 16Amp Switch Socket Combine 186 Supply, Installation, Testing & Commisioing Of 32 Amp With Dp Switch Socket Combine 187 Supply, Installation, Testing & Commisioing Of Pendent Holders 188 Supply, Installation, Testing & Commissioing Of Lt Distribution Box For25kva Dtr With Mccb For Incommer And McbS For Outgoing Ckt. With Terminal Extensions ( Complete ) 189 Installation, Testing & Commissioing Of Lt Distribution Box For25kva Dtr With Mccb For Incommer And McbS For Outgoing Ckt. With Terminal Extensions ( Complete ) 190 Supply, Installation, Testing & Commissioing Of Lt Distribution Box For 63Kva Dtr With Mccb For Incommer And McbS For Outgoing Ckts.With Terminal Extensions ( Complete ) 191 Installation, Testing & Commissioing Of Lt Distribution Box For 63Kva Dtr With Mccb For Incommer And McbS For Outgoing Ckts.With Terminal Extensions ( Complete ) 192 Supply, Installation, Testing & Commissioing Of Lt Distribution Box For 100Kva Dtr With Mccb For Incommer And McbS For Outgoing Ckts. With Terminal Extensions ( Complete ) 193 Installation, Testing & Commissioing Of Lt Distribution Box For 100Kva Dtr With Mccb For Incommer And McbS For Outgoing Ckts. With Terminal Extensions ( Complete ) 194 Supply, Installation, Testing & Commissioing Of Lt Distribution Box For 250Kva Dtr With Mccb For Incommer And McbS For Outgoing Ckts.With Terminal Extensions ( Complete ) 195 Installation, Testing & Commissioing Of Lt Distribution Box For 250Kva Dtr With Mccb For Incommer And McbS For Outgoing Ckts.With Terminal Extensions ( Complete ) 196 Supply, Installation, Testing & Commissioing Of Lt Distribution Box For 400Kva Dtr With Mccb For Incommer And McbS For Outgoing Ckts.With Terminal Extensions ( Complete ) 197 Installation, Testing & Commissioing Of Lt Distribution Box For 400Kva Dtr With Mccb For Incommer And McbS For Outgoing Ckts.With Terminal Extensions ( Complete ) 198 Supply Of 4Pole 200Amp, 415V, 50Hz, Off Load Change Over Switch Conforming To Latest Is Standards Of Reputed Brands Like Havells, L&T Etc. 199 Supply Of 4Pole 100Amp, 415V, 50Hz, Off Load Change Over Switch Conforming To Latest Is Standards Of Reputed Brands Like Havells, L&T Etc. 200 Supply Of 4Pole 63Amp, 415V, 50Hz, Off Load Change Over Switch Conforming To Latest Is Standards Of Reputed Brands Like Havells, L&T Etc. 201 Supply Andinstallation Of Ms Kiosk For Housing Of Changeover Switches 202 Unloading Of Line Material & Workshop Material Like Acsr ( 30Mmsq, 50Mmsq, 100Mmsq, Dpc, T.Oil ( Barrels ) , Gi Wire, Link Sets, Do Sets, Nuts & Bolts, Channel Iron Of Sizes, Disc Sets, Braces Of Sizes, Bush Rods, Alm. Strips, Insulators, Etc. From Divisional Stores 203 Loading Of Line Material & Workshop Material Like Acsr ( 30Mmsq, 50Mmsq, 100Mmsq, Dpc, T.Oil ( Barrels ) , Gi Wire, Link Sets, Do Sets, Nuts & Bolts, Channel Iron Of Sizes, Disc Sets, Braces Of Sizes, Bush Rods, Alm. Strips, Insulators, Etc. From Divisional Stores