Repair / Maintenance Of Internal Electrical Day To Day Complaints For Buildings At Vat Site And Ram Mandir Area, Map Buildings And Sma Varunapuriunder Age E / M - Ii Of Ge ( Nw ) Vasco. ( Tender Id No. 2023_Mes_589713_1 ) . 1 Checking And Attending Electrical Complaints For Continuous Electric Supplylike No Light / Short Circuit / Non Working Fittings / Fixtures / Post Top Lantern / Bollard Lights Including Replacement Of Unserviceable Partssuch Asswitch, Socket, Holders, Tube Light And Including Carrying Out Theminor Repair Likefixing Screws, Tightening Of Loose Wires, Any Type Renewal Of Small Pieces Of Electric Wire Upto 1.00 Mtr Length And Maintenance Work Complete On All Working Days All As Directed By Engineer-In-Charge. 2 Checking And Attending Electrical Ceiling Fan / Exhaust Fancomplaint Including Replacement Of Unservicable Ceiling / Exhaust Fan Condensor Of Any Capacity Complete On All Working Days All As Directed By Engineer-In-Charge. 3 Attending Of Complaints Of Geyser At Site Including Checking And Rectification Of Any Electric Fault / Water Leakage And Making Good In All Respects Including Minor Repairs, Replacement Of Unserviceable Switch, Socket, Burnt Copper Wire Connections Wherever Required Complete All As Specified And Directed By Engineer-In-Charge.Notefor Item No 1, 2, & 3 Of Boq:- ( A ) Rate Inclusive Of Fixtures Like, Switches, Sockets, Holders Condensor, Tubes For Tube Lights Of Any Capacity. ( B ) Plug Top For Geyser Will Be Measured And Paid Separately Under Items Supply Only. ( C ) Contractors Are Advised To Visit The Sites Before Quoting Their Rates. ( D ) Materials For Repair Works As Directed By Engineer-In-Charge Shall Be Supplied By The Contractor And Adequate Stock Shall Be Held All The Time By Contractor ( E ) Anynature Of Electrical Complaint, The Entire Responsibilty Of Rectification Lies With The Contractor. 4 ( F ) Contractor Shall Be Penalised @ Rs. 2000 / - Per Day Per Complaint, If He Fails To Attend The Complaint Within 12 Hours. ( G ) All Serially Numbered Complaint Docket Will Be Provided By Contractor And Cost Of Docket Included In The Rate Quoted For The Items. ( H ) All T&P, Safety Gadgets Shall Be Provided By The Contractor. ( J ) Rep Of The Contractor Shall Receive Complaintsin Morning 0900 Hrandgive Feedback On Daily Basis To Concerned Je E / M ( K ) Payment To Contractor Released After Submission Of These Complaints Duly Rectified Within Time And Duly Signed By Contractor, Je, And Engineer-In-Charge In Rar / Final Bill. ( L ) Contractor Shall Maintain The Maintinance Register Showing All Daily Complaints Recieved And Shall Maintain Job Cards For Attending Complaints. The Signature Of The User Shall Be Obtained On The Job Card Showing The Material Incorporated In The Work After Completion Of The Job With Date. 5 M&L In Repairs For Switch Piano Type Single Pole One Way 5 Amps 230 V Complete All As Specified And Directed By Engineer-In-Charge. 6 M&L In Repairs For Modular Switch 1 Way 6A, 1 Module 230 V Complete All As Specified And Directed By Engineer-In-Charge. 7 M&L In Repairs Switch Piano Sp Two Way 230 V Complete All As Specified And Directed By Engineer-In-Charge. 8 M&L In Repairs For Modular Switch Socket Outlet 3 Pin 5 Amp Flush Type 230 V Complete All As Specified And Directed By Engineer-In-Charge. 9 M&L In Repairs For Modular Switch Socket Outlet MultiPurpose 3 Pin, 15 Amp And One Pin, 5 Amp Controlled By One Switch 230 V Complete All As Specified And Directed By Engineer-In-Charge. 10 M&L In Repairs Swtich Socket Combination 2 In 1, 5A 3 Pin And 5A 2 Pin Combined Flush Type, 230 V, Complete All As Specified And Directed By Engineer-In-Charge. 11 M&L In Repairs For Bell Push Single Pole 5 Amps, 230 V Complete All As Specified And Directed By Engineer-In-Charge. 12 Supply And Fix In Repairs Switch Socket Combination 2 In One 3 Pin 5 A And 3 Pin 15 A Combined Flush Type. 13 M&L In Repairs Switch Piano Flushbutton Type Single Pole 15 Amps. 230 V Complete All As Specified And Directed By Engineer-In-Charge. 14 Supply And Fix Socket Outlet Flush Type 2 In 1, 3 Pin 5 And 15 Amp Single Pole, 230 V Complete All As Specified And Directed By Engineer-In-Charge. 15 Supply And Fix In Repairs Socket Outlet 2 In 1, 3 Pin, 5A Single Pole, 230 V Complete All As Specified And Directed By Engineer-In-Charge. 16 Supply And Fix In Repairs Ceiling Fan Regulator Electronic Stepped Type, Suitable For 1200 / 1400 Mm Sweep Ceiling Fan, 230 Volts Single Phase Complete All As Specified And Directed By Engineer-In-Charge. 17 Taking Down Ceiling Fan From Site And Hand Over / Deposit To Age E / M Yard For Repair / Servicing / Rewindingetc Complete All As Directed At Site. 18 M&L For Rewinding Of Fan Motor Including Changing / Servicing Of Bushes Etc Complete All As Directed By Engineer-In-Charge. 19 Hanging Only Ceiling Fan And Connecting Up Including Provision Of Cable From Ceiling Rose Or Connector To Fan Complete 20 M&L For Painting Of Ceiling Fans Complete, In Situ With Synthetic Enamel Paint By Spraying Including Filling Cavities With Filler, One Coat After Cleaning All Dust Etc Inlcuding Writing Mes No. Etc Complete All As Specified And As Directed. 21 Supply And Fix In Repairs Pvc Ceiling Rose, Surfacetype, With Three Terminals Complete All As Specified And Directed By Engineer-In-Charge. 22 Supply And Fixin Repairs Electric Bell Ding-Dong Ac 230 Volt Etc Complete All As Specified And Directed By Engineer-In-Charge. 23 Supply And Fixin Repairs Pvc Insulated Body, Angle / Straightlamp Holderwith Back Plate Complete All As Specified And Directed By Engineer-In-Charge. 24 Supply Only Industrial Metal Clad Plug Top, 3 Pin, 20 Ampcomplete All As Specified And Directed By Engineer-In-Charge. 25 Supply And Fixing In Repairs Led Lights Fitting 1X 18W, 220V, Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete 26 Supply And Fixing In Repairs Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 10 Watt 220 V Ac Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete 27 Supply And Fixing In Repairs Mcb Isolator Dp 40 Amps, 240 Volts, 10 Ka 50 Hz C Curve Complete All As Specified And Directed By Engineer-In-Charge. 28 Supply And Fixing In Repairs Mcb Sp 6-32Amps, 240 Volts, 10 Ka, 50 Hz C Curvecomplete All As Specified And Directed By Engineer-In-Charge. 29 Supply And Fixing In Repairs Isolator Tpn 63 Amps 415 Volts Complete All As Specified And Directed By Engineer-In-Charge. 30 Supply And Fixing In Repairs Mccb 160 Amps, Fp 415 Volts 16 Ka 50 Hz With Thermal Magnetic Setting . Complete All As Sspecified And Directed By Engineer-In-Charge. 31 Supply And Fixing In Repairs Hylam Sheets 3Mm Thick Including Cutting For Mounting Of Switches / Socketssuitable For Sunken Box Of Sizes 4X4. 32 Supply And Fixing In Repairs Hylam Sheets 3Mm Thick Including Cutting For Mounting Of Switches / Socketssuitable For Sunken Box Of Sizes 8X10. 33 Supply And Fixing In Repairs Hylam Sheets 3Mm Thick Including Cutting For Mounting Of Switches / Sockets / Suitable For Sunken Box Of Sizes 10X12. 34 Supply And Fixing Replacement Of Capacitor 2.5 Mfd, 240 Vcomplete All As Specified And Directed By Engineer-In-Charge. 35 Supply And Fixing Hole Fastner Made Up Of Ms 10Mm Dia Standard Lengthwithnut Boltcomplete All As Specified And Directed By Engineer-In-Charge. 36 Supply And Fixing In Repairs Heating Element Of 1.5 / 2 Kw Any Type With Nut Bolt Washer Complete As Per Site Requirement All As Specified And Directed By Engineer-In-Charge. 37 Supply And Fixing In Repairs Thermostat For 6 / 11 Suitable Forgeysers Of Capacity 25 / 50 Ltrscomplete All As Specified And Directed By Engineer-In-Charge. 38 Supply And Fixing In Repairs Pvc Connection Pipe Of 12 Mm ( ( Internal ) Suitable For Hot / Cold Water, 45 Cm Long With Brass Nuts And Rubber Washerscomplete All As Specified And Directed By Engineer-In-Charge. 39 M&L For Point Wiring Complete With Frls 1100 Volts Grade, Two Runs Of 2.5 Sqmm Coppercable Drawn Through And Including Pvc Casing And Capping With One Run Of 2.5 Sqmm Pvc Insulated And Unsheathed Multistranded Copper Conductor Cable As Earth Continuity Wire Connected To Common Earth Dolly Including Taking Down Old Unservicable Point Wiring Including Switches, Sockets Etc Complete All As Specified And Directed 40 M&L Point Wiring For One Light / Fan Point Complete With 1100Volt Grade Pvc Insulated Unsheathed Multistranded 1.5 Sqmm Copper Conductor Cable Confirming To Is 694 Frls Drawn Through And Including Rigid Pvc Casing And Capping Medium Grade Of Size 25 / 20 Mm, Etcfixed On Wall / Ceiling Including Provision Of 1.5 Sqmm Pvc Unsheathed Copper Conductor As Earth Conductor And Connected To Earth Dolly, Including Provision Of Pressed Steel Terminal Box With 3Mm Thick Plastic Laminated Sheet Top Cover For Housing Switches, Sockets Etc Concealed On Wallincluding Taking Down Old Unservicable Point Wiring Including Switches, Sockets Etc Complete All As Specified And Directed Complete All As Specified And Directed. 41 Supply Only Pvc Isulated Multistranded Copper Conductor Cable 1100 V Grade 1.5 Sqmm Size For Day To Day Repair Work. 42 Taking Down Old Unservicable Ceilling Fan By Disconneting And Providing New Ceilling Fan 1200Mm Sweep Complete With Blades, Down Rods, Electronic Regulator And Acessories , 230 Volt Min Air Dilevery 210 Cfm With Service Value 6.00 Bee, Five Star Rated With Brushless Direct Current Motor ( Bldc ) , Hanging On The Same Location, Reconnecting, Testing And Commissioning Complete All As Specified. Note:- The Old Ceilling Fans Will Be Deposited To The Mes Yard At Age E / M-Ii Of Ge ( Nw ) Vasco. 43 Supply And Fix In Repair Of Exhaust Fan 230V Single Phase Plastic Body / Metal Body ( As Per Site ) Sweep Size Up To 300Mm, 1400 Rpm Connecting Up Including Provision Of Necessary Wall Opening If Required, Making Good To Match The Existing Finish And Connecting Up With Cable From Ceiling Rose Or Connector To Exhaust Fanetc Complete All As Specified And Directed. ( Note: Old Exhaust Fan Deposited In Store )