Repair & Maintenance To Overhead Lt Lines, Ug Lt Lines, Transformers, Distribution System And Connected Works In Army Area At Mount Abu Under Age ( I ) Udaipur. 1 Excavating In Trenches N. Exc 1.5M Wide And N. Exc 1.5M In Depth For Foundation / Pipes / Cable Etc, N. Exc 10Sqm On Plan And N.Exc 1.5M In Depth And Getting Out In Hard / Dense Soil Complete All As Specified And Directed. 2 Returning, Filling In, Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exc 25Cm Thick, In Soil Complete All As Specified And Directed. 3 Removing Of Excavated Surplus Soils, N.Exc 50M And Depositing Where Directed At A Level N.Exc 1.5M Abovethe Starting Point Complete All As Specified And Directed. 4 Material & Labour For Sand Cushioning For Pvc / Xlpe Cable With Screened And Washed Sand And Punning To Provided A Required Covers All As Specified And Directed. 5 Material & Labour For Double Wall Corrugated Hdpe Pipe, Heavey Duty For Laying Of Electric Cables Cross-Sectional Area 80Mm Dia Completeall As Specified & Directed. 6 Laying Onlyxlpe Insulated, Armoured Heavey Duty Electric Cables With Aliminium Concductor, 1100 Volts Grade Cross-Sectional Area 25 To 95 Sqmm3½ Core Complete With Lugs And Clamps All As Specified & Directed. Cable Will Be Issued Under Sch B Free For Fixing 7 Material And Labour Painting Or Old Surface And Applying Two Coats Of Aluminium Paint Over A Coat Zinc Chrome Primer To Existing Ms Channel , Clamps, Etc On Exixting Rcc Poles Of 9 / 11 Mtr All As Specified And Directed. 8 Material And Laour For Cutting Of Tree-Branches Touching Ht / Lt Oh Lines Having Grith Exc 30Cm And Branches To A Distance N.Exc 50Mtr And As Directed 9 Material And Labour Spray Painting The Existing Lt Panel Boards Joutdoor Type Of Any Size With Single Coat Of Synthetic Enameled Paint Of Superior Quality And Approved Colour After Preparation Of Steel Surface. The Panel Door Shall Be Painted Internally And Externally Both And Remaining Portion Of The Panel Shal Be Paintedexternally Only. 10 Dismantling Of Old Acsr Conductors From Lt Steel Tubler Pole / Rcc Polecomplete All As Specified And Directed. 11 Taking Down Old Unsv Bus Bars Chamber And Supply And Install, Testing And Commissioning Of Bus Bar Chamber Of Size 90 Cm X 90Cm X 40 Cm Outdoor Type Suitable For Lt 415 Volts 3 Phase 4 Wire System Factory Made Cubical Complete Materialised Dust And Vermin Proof ( Protection Class Ip 54 ) , Made Out Of 3.15Mm Thick Ms Sheet ( Crca ) Including Factory Made Hinged Type Door Both Side Opening With Locking Arrangement Duly Painted With Two Coats Of Synthetic Enamel Paint With Powder Coated Finish Over A Coat Of Zinc Chrome Primercompleteall As Specified And Directed By Engineer-In-Charge. The Panel Board Shall Be Comprising Of The Following Accessories 12 ( A ) Incomming Mccb 160A - 01 No With Suitable Aluminum Bus Bar Arrangement System. 13 ( B ) Digital Voltmeter-96 X 96 Mm Flushsecure Panel Mounting Type 0-500V With Selector Switch- 01 14 ( C ) Digital Amp Meter96 Mm X 96 Mm Flush Secure Panel Mounting Type 0-100 Amps With Selector Switchwith Ct - 01 15 ( D ) Ryb Neonindicatinglamp Setof Three- 01 16 Notes :- ( I ) Rates Are Deemed To Be Inclusive Of Pcc Platform Of Suitable Size And 45Cm Height And 4 Nos Legs Of 50Mmx50mmx6mm And 60 Cm In Height For Fixing The Panel ( Iii ) Danger Notice Plate ( 02 Nos ) Lt Size 20Cmx 15Cm Shall Be Fixed On The Panel ( Iv ) Contractor Provided Power Coated Finish Paint On Panel. 17 Material & Labour For Renewal Ofplate Earthing For Lt Panel With Galvanisedmild Steel Plate Electrode 60 Cm X 60 Cm X 6 Mm Thick Buried Directly In Ground Vertically ( In Earth Pit Not Less Than2.25 M Below Normal Ground Level ) With The Top Edge Of The Earth Plate At A Depth Not Less Than 1.5 M Below Normal Ground Level, The Earth Electrode Surrounded By Adequate Quantity Of Charcoal Dust And Salt To A Packed Thickness Of 15 Cm On All Sides And Incl Gi Earth Strip 32 X 6 Mm Bolted ( With Gi Nuts, Bolts & Check Nuts ) And Riveted To Earth Plate Electrode At One End And Connected To Metallic Bodies Of Ht / Lt Equipments Etc At The Other, Earth Strip Encased In And Including 40Mm Boregimedium Grade Pipe With All Fittings From Top Of Electrode To Body Of Equipment Fixed With And Including 40 X 6Mm Flat Iron Clamps, Bolts, Nuts And Washer And Also Including Providing Watering Pipe 20Mm Bore Gi Pipe Medium Grade From Bottom Of Earth Pit To Top Of Electrode Complete With Earth Pit In Pcc 1:2:4 Type B-O Using 12 Mm Graded Crushed Stone Aggregate, Rcc Cover, Funnel, Wire Mesh Including Necessaryexcavation And Earth Work , Etc Complete All As Specified And Shown In Electrical Plate No 3 Of Ssr Pt-I. 18 -Ditto- All As Per Item No 25 Above But Using Glavanised Iron Strip 25X4mm As Earthing Lead Complete All As Specified And Directed By Engr-In-Charge 19 Material & Labour For Lt Aerial Bunched Cable Of Size 3X70 Sqmm Phase Conductor, 1X50 Sqmm Neutral Conductor And 1X55 Sqmm Messenger Conductor Complete All As Specified And Directed. Make-Unistar / Polycab / Havells 20 Material & Labour For Lt Aerial Bunched Cable Of Size 1X16 Sqmm Phase Conductor, 1X16 Sqmm Neutral Conductor And 1X25 Sqmm Messenger Conductor Complete All As Specified And Directed. Make-Unistar / Polycab / Havells 21 Material & Labour For Suspension Hook Of Lt Aerial Bunched Cable Complete All As Specified And Directed. 22 Material & Labour For Dead End Clamp Of Lt Aerial Bunched Cable Complete All As Specified And Directed. 23 Material & Labour For Pg Connector Of Lt Aerial Bunched Cable Complete All As Specified And Directed. 24 Material & Labour For Insulation Piercing Connector Of Lt Aerial Bunched Cable Complete All As Specified And Directed. 25 Material & Labour For Smdb Box Outdoor Horizontal Type 3 Phase And Neutral To Distribute Lt Aerial Bunched Cable And Fixed In Rcc Pole Complete All As Specified And Directed. 26 Material & Labour For Smdb Boxoutdoor Type Singlephase And Neutral ( For Security Light ) Of Lt Aerial Bunched Cable Complete All As Specified And Directed. 27 Disnantling Old Unserviceable Lt Concrete Pole, Any Size And Removing From Site Complete All As Directed 28 Dismantling Stay Assembly Complete, Any Type, Any Size Complete Making Good Disturbed Surfaces And Removing From Site As Per Splecified And Directed 29 Supply & Errect In Position 9.00 Mtr Long Prestressed Cement Concrete Poles Of Cross Section 102X152mm Attop And 102X289mm At Bottem, Class 10 Conforming To Is-1678-1978 All As Specified And Directed. 30 Supply And Fixing Stay Assembly Comprising Of Stay Bow Glavanised 14Mm Dia X 400Mm Stay Rod 16Mmx1.80Mtr Long With Nuts, Bolts, Washer, Ms Stay Plate, Two Nos Thimble And Clamps Etc Complete All As Specified In Electrical No-1 Of Ssr Part-I Note:Loop Type Insulator, Excavation & Earth Work And Concrete Foundation Shall Be Measured And Paid Separately Under Respective Of Sch A 31 Material And Labour For Pin Type, Porcelain Votrcous White, Brown Or Insulators Incl One Gaivanized Ms Spindle, Two Glacanized Iron Washers & One Gi Nut, 100Mm Hight, 65Mm Dia 1100 Volts Grade Complete All As Specified And Directed. 32 Material And Labour For Shackle Type, Insulator Porcelain Votrcous White Including Glaivanized Ms Strips Washers & Nuts Working Pressure 1100 Volts, 100Mm High And 115Mm Dia Complete All As Specified And Directed. 33 Material And Labour For Cross Arms, Bracing, Supports, Back Plate & Clamps Faricated From Structural Steel Section Including Nuts, Bolts, Washer Cuttings, Welding Bending Cold Or Hot, Drilling Holes For Bolts In Any Shape For Bolts Inany Shape Of Size Inclusive Of Painting With 2 Coats Of Aluminium Paint Over A Coat Of Primer Complete All As Specified And Directed. 34 Removing Of Old Unsv Aluminium Cable Lugs From End Terminal Of Ug Cable And Material & Labour For Crimping Of And Including Aluminium Lugs Of Following Sizes :- 35 95 Sqmm X 3.5 Core 36 70 Sqmm X 3.5 Core 37 50 Sqmm X 3.5 Core 38 35 Sqmm X 3.5 Core 39 25 Sqmm X 3.5 Core 40 Supply And Fixing Mccb, 4 Pole 415 Volts, Adjustable Type With Necessary Modifications In Panel Board For Connection Of Mccbs Complete All As Directed Including Connecting And Testing Of The Following Capacity :- 41 400 Amps, 36 Ka Breaking Capacity, 4 Pole, 50 Hz, 415 Volts, Make : Abb / Havells / Hpl 42 200 Amps, 36 Ka Breaking Capacity, 4 Pole, 50 Hz, 415 Volts, Make : Abb / Havells / Hpl 43 160 Amps, 36 Ka Breaking Capacity, 4 Pole, 50 Hz, 415 Volts, Make : Abb / Havells / Hpl 44 63 Amps, 16 Ka Breaking Capacity, 3 Pole, 50 Hz, 415 Volts, Make : Abb / Havells / Hpl