}

Tender For Up Gradation Works Of Community Health Centres At Mullasseri, Thrissur District, thrissur-Kerala

Boards / Undertakings / PSU has published Tender For Up Gradation Works Of Community Health Centres At Mullasseri, Thrissur District. Submission Date for this Tender is 26-04-2023. Paint System Tenders in thrissur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

37246487
Tender For Up Gradation Works Of Community Health Centres At Mullasseri, Thrissur District
Open Tender
Indian
Kerala
Thrissur
26-04-2023

Tender Details

Up Gradation Works Of Community Health Centres At Mullasseri, Thrissur District. 1 Civil Works 1.01 15.7.4 : Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 1.02 15.3 : Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. 1.03 15.28.1 : Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 1.04 5.9.6 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 1.05 5.9.5 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 1.06 5.22A.6 : Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 1.07 5.2.2 : Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 1.08 50.6.1.5 : Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 30X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Etc Complete 1.09 50.6.6.2 : Hollow Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x10cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In: Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Including Cost Of Scaffolding Etc Complete 1.1 13.1.1 : 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand ) 1.11 22.5 : Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 1.12 11.38 : Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) , Of Ist Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. 1.13 8.31 : Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineerin-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 1.14 10.28 : Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc. ) 1.15 21.1.1.2 : Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) :For Fixed Portionpowder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 1.16 21.1.2.2 : For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 1.17 21.3.2 : Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) :With Float Glass Panes Of 5.50 Mm Thickness 1.18 9.117.1 : Providing And Fixing Factory Made Upvc Door Frame Made Of Upvc Extruded Sections Having An Overall Dimension As Below ( Tolerance ±1 Mm ) , With Wall Thickness 2.0Mm ( ±0.2 Mm ) , Corners Of The Door Frame To Be Jointed With Galvanized Brackets And Stainless Steel Screws, Joints Mitred And Plastic Welded. The Hinge Side Vertical Of The Frames Reinforced By Galvanized M.S. Tube Of Size 19 X 19 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness And 3 Nos. Stainless Steel Hinges Fixed To The Frame Complete As Per Manufacturers Specification And Direction Of Engineer-In-Chargeextruded Section Profile Size 48X40 Mm 1.19 9.118.2 : Providing And Fixing To Existing Door Frames30 Mm Thick Factory Made Polyvinyl Chloride ( Pvc ) Door Shutter Made Of Styles And Rails Of A Upvc Hollow Section Of Size 60X30 Mm And Wall Thickness 2 Mm ( ± 0.2 Mm ) , With Inbuilt Decorative Moulding Edging On One Side. The Styles And Rails Mitred And Joint At The Corners By Means Of M.S. Galvanised / Plastic Brackets Of Size 75X220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Inserting Galvanised M.S. Tube Of Size 25X20 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness. The Lock Rail Made Up Of H Section, A Upvc Hollow Section Of Size 100X30 Mm And 2 Mm ( ± 0.2 Mm ) Wall Thickness Fixed To The Shutter Styles By Means Of Plastic / Galvanised M.S. U Cleats. The Shutter Frame Filled With A Upvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Inserting Horizontally 6 Mm Galvanised M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. 1.2 13.80 : Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 1.21 13.48.1 : Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications:Two Or More Coats Applied On Walls @ 1.25 Ltr / 10 Sqm Over And Including One Coat Of Special Primer Applied @ 0.75 Ltr / 10 Sqm 1.22 12.52.3 : Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595 X 595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams Per Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85X 30X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer -In-Charge.12.5 Mm Thick Square Edge Pvc Laminated Gypsum Tile Size 595X595 Mm Made Of Gypsum Plasterboard , Manufactured From Natural Gypsum As Per Is 2095 Part I And Laminated With White 0.16 Mm Thick Fire Retardant Pvc Film On The Face Side And 12 Micron Metalized Polyster On The Back Side With All Edges Sealed With The Face Side Pvc Film Which Goes Around And Wraps The Edges And Is Bonded To The Edges And The Back Side Metalized Polyster Film So As To Make The Tile A Completely Sealed Unit. 1.23 50.10.1 : Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 1.24 10.1 : Structural Steel Work In Single Section, Fixed With Or Without Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 1.25 13.61.1 : Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 1.26 26.19.1 : Providing At All Heights, Levels And Locations Aluminium Profile Industrial Troughed Sheet Of Alloy 31500 / 31000 / 40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I / C Cutting To Size And Shape Where Required As Per Specifications, Detail Drawings And Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealent Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses.0.71 Mm Thick, The Profile Detail Width 1044 / 920 Mm, Cover Width 1000 / 875 Mm. 1.27 12.41.2 : Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes.110 Mm Diameter 2 Plumbing 2.01 50.18.8.2.1 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 20 Mm Pipe 12 Kgf / Cm2 2.02 50.18.8.6.2 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 6 Kgf / Cm2 2.03 50.18.8.8.1 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 75 Mm Pipe 6 Kgf / Cm2 2.04 50.18.8.9.1 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf / Cm2 2.05 17.2.1 : Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 2.06 50.17.1.4 : Supplying And Fixing Cp Health Faucet Good Quality Including Cost Of Materials And Labour Charges Etc. Complete As Per The Direction Of Site Engineer-In-Charge. 2.07 17.7.1 : Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 2.08 17.28.1.1 : Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc. Waste Fittings Complete.Semi Rigid Pipe32 Mm Dia 2.09 18.50.1 : Providing And Fixing C.P Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms.15 Mm Nominal Bore 2.1 18.58.2.1 : Providing And Fixing Ptmt Grating Of Approved Quality And Colour.Rectangular Type With Openable Circular Lid150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating 3 Electrical 3.01 1.3.3 : Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 3.02 1.7.1 : Wiring For Circuit / Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 3.03 1.24.1 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amps Switch 3.04 1.25 : Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3.05 1.27.4 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.6 Module ( 200Mmx75mm ) 3.06 1.44 : Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 3.07 1.50.1 : Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep 3.08 2.3.7 : Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator2 + 8 Way, Double Door 3.09 2.4.5 : Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 6 Way ( 4+18 ) , Double Door 3.1 2.5.1 : Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 4 Way ( 4 + 12 ) , Double Door 3.11 2.10.1 : Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 3.12 2.13.1 : Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 3.13 2.13.2 : Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps 3.14 2.14.2 : Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 3.15 2.15.3 : Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps 3.16 90.12.7.42 : Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required. 3.17 90.12.7.43 : Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required. 3.18 90.16.1.3 : Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required 3.19 Od340730 / 2022_2023 : 1200Mm Sweep- Ceiling Fan Complete With 300 Mm Down Rod, 2 Number Canopies, Shackele Kit, Copper Winding, 3 Number Blades And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers Suitable For 230V / 240V Single Phase Ac Supply Etc. Complete As Required. 3.2 Od340731 / 2022_2023 : 2X2 Square Type Recess Mounted Led Light≪Br≫Sitc Of 600Mmx600mm Square Type Cool White, Warm White, Pure White Led Light Fixture With Integrated Driver &Amp; Backlight Technology With A Minimum System Efficacy Of 95W / Lm, Standard Cct: 3000K*, 4000K &Amp; 6500K, High Color Rendering Cri ≫80, With High Efficiency Driver, Minimum Of 35000 Hours Working Life, And Surge Protection -4Kv ( Light Variant As Decided By Engineer In Charge ) , Including Connection With Existing Point Using Suitable Gauge Copper Conductor Directly To The Ceiling Rose. Each Module Should Be Tested And Qc Approved By Competent Authority And The Same To Be Furnished Before Electrical Engineer

Key Value

Document Fees
INR 2950 /-
EMD
INR 50000.0 /-
Tender Value
INR 31.01 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail