Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Dewa Of Jal Shakti (Phe) Mechanical Division South Awantipora Under Jjm., pampore-Jammu And Kashmir

Public Health Engineering Department has published Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Dewa Of Jal Shakti (Phe) Mechanical Division South Awantipora Under Jjm.. Submission Date for this Tender is 16-05-2023. Electromechanical Machinery Tenders in pampore Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

37229060
Corrigendum : Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Dewa Of Jal Shakti (Phe) Mechanical Division South Awantipora Under Jjm.
Open Tender
Indian
Jammu And Kashmir
Pampore
16-05-2023

Tender Details

Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Dewa Of Jal Shakti ( Phe ) Mechanical Division South Awantipora Under Jjm.-2 Supply, Installation, Testing & Commissioning Of Submersible Pumping Unitas Per Is 8034 With Following Specification Are As Under :Pump :Discharge: 5000 Gph Head: 80 Mtrspeed= 2900 Rpmtype Of Pump = Mixed Flow.Type Of Fluid To Be Handled=Clear Watermotor:-Not Less Than 10 Hpmethod Ofstarting = Star – Deltaspeed = 3000 ( Sync ) .Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 Phaseefficiency = Not Less Than 90%Note: Providing Of Test Certificate & Characteristic Curve Of Pumping Equipment Is Compulsory And Pumping Unit Is To Be Approved From The Concerned Sub Divisional Office Before Procuring. Detailed Specifications As Per Cluase 1 Sbd 3 Fabrication, Providing, Fitting And Lowering Ofcolumn Pipe Conforming To Is: 1239 Of Length 10 Rft Into The 200 / 250 / 300 Mm Casing Dia. Production Well Up To The Desired Depth ; The Job Includes Providing And Welding Of Flanges Conforming Tois: 6392, Table-17 And Pn 16 Size: Dn 65Class: B ( Medium ) Rest Specification As Per Details In Cluase 7 Of Sbd 4 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) .S. The Rising Main Is To Be Laid As Per The Instructions Of The Engineer In Charge And Site Requirement And Details As Per Cluase 8 Of Sbdsize : Dn80class: C ( Heavy ) 5 Earth Work In Excavation By Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed. All Kinds Of Soil 01 Meter From Cutting Edge 6 Filling Available Excavated Earth In Trenches, Plinth, Sides Of Foundation Etc.In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Reaming And Watering , Lead Upto 50 M And Lift Upto 1.5M. 7 Extra For Every Additional Lift Of 1.5 M Or Part Thereof In Excavation / Banking Excavated Or Stacked Materialin All Kinds Of Soil 8 Providing And Laying Of Stone Soling Including Manual Compaction 9 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Foundation , Footings , Bases For Columns 10 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering . All Work Upto Plinth Level With 1: 2 : 4 Mix ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) 11 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. Size: 65Mm 12 Fabrication , Providing And Fitting Of90-120 Degree Bend / Elbowto Be Fabricated Out Ofg.I Pipeand Flanged On Both Ends Ato Make It Leak Proof. The Flanges Shall Be M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) And Welded On Both Sides. The Job Includes Nuts, Bolts, Gaskets Etc As Per Site Requirement.Size:Dn 80, Class: C 13 Providing And Fitting Of 300Mm In Length Gi Reducer Bend Flanged On Both Sides, Flange Conforming To Table-17 ( Pn16 ) To Be Fitted With The Column Pipe / Delivery Manifold Of Submersible Pumping Unit To Join Rising-Main And Column Pipe / Delivery Manifold. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes From Inside And Outside Of Pipe To Form Strong Welding Joint.Size: 80Mm-65Mm , Class: C 14 Fabrication, Providing And Fitting Of T -Junction Out Of 1M Of Pipe With 1Ft Each Arm. The Job Includes All Types Of Skilled Labour, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Table 17 Flanges, Suitable Size Nuts, Bolts And Ri Gasket In The Flanged Joints ( Rest Specification As Per Clause 09 Of Sbd ) . Size: 80Mm, Class: C Class 15 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Size 80 Mmpn1.6Manufacture Test Certificate To Be Appended. Rest Ofspecification As Per Cluase 12Of Technical Anexure Of Sbd 16 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size 80 Mm Pn 1.6Manufacture Test Certificate To Be Appended. Rest Ofspecification As Per Cluase 13Of Technical Anexure Of Sbd Size: 80Mmpn: 1.6 / 16 17 Fabrication Of Gravel Hooper For Proper Feeding Of Gravels To The Borewell Andplatform To Bear The Load Of Pumping Unit, Column Pipes Etc By Way Of Providing And Fitting Of Steel Work Welded In Built Up Sections / Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. The Job Involves Following Steel Details: In Stringers , Treads , Landings Etc Of Stair Cases Including Use Of Chequered Plate Wherever Required , All Complete 18 In Grating , Frames , Guard Bar , Ladder , Railings, Brackets, Gates And Similar Works 19 Providing And Fitting Ofm.S 4 Inch Hinges -6 No And M.S Handle Heavy -8No., Anchor Bolts With Nuts ( M16 ) Of 0.3 M Long= 04 No. Metallic Strip ( 350Mm×50Mm×3Mm ) = 02 No. 20 Fabrication Of Gantry Mechanism / Cgi Shed / Angle Iron Bed By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded. 21 Providing, Installation Andtestingof Manual Type Triple Spur Gearchain Pulley Block Along With Monorail Gearedtravelling Trolleyhaving Following Features : Make= Reputed Makecapacity =2Ton No. Of Load Chain Falls = 2 Or Abovemin. Height Of Lift = 6 M Manufacture Test Certificate To Be Appended.Rest Ofspecification As Per Cluase 24Of Technical Anexure Of Sbd 22 Creation Of Pope Mounted , Outdoor Type Electric Sub Stationby Way Ofs / I / T / C Of 11 / 0.433 Kva , 3 Phase Distribution Transformer With Bimetallic Terminal Connectors Energy Level -2 Aluminum Woundspecifications Conforming To Is : 1180 ( Part 1 ) 2014 With Latest Amendments Ertificaterating:63Kva Ht Transformer, 3 Phase ( Level 2 ) . Manufactures Test Certicicate To Be Apended And Rest Of Specification As Per Cluase 26 Of Sbdnote: The Scope Of The Work Shall Include Obtaining Of Necessary Inspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate 23 Providing And Fittingg.I Channel / Angle / Flat Of Sizes Including Clamps 24 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Ofht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 25 Supply, Installation, Testing And Commissioning Of 11Kvpolymer Fuses Sethorn Gap3-Phase 200 Asuitable For Vertical Installation . 26 Supply, Installation, Testing And Commissioning Ofgapless Surgearrestor Station Class, 10Ka, 9Kv, La With Polymer Housing , Station Type . 27 Supply And Fitting Of 11 Kv Polymeric Composite Pin Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creepagedistance 320 Mm 28 Supply, Installation, Errection Of9 Mtrs Long St- 410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required. The Job Further Includes Gi Wire Earthing Of Pole As Per Rec Standard. 29 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement. 30 P / F Danger Plate With Clamps 31 Providing And Fixing G.I Barbed Wire For Anti Climbing 32 Providing And Fixing Of Anti Climbing Devices With Clamps 33 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete. 34 Painting Of Poles Red Oxide 35 Painting Of Poles Aluminum Paint 36 Providing And Fitting Of Acsr As Per Is 398 ( Part-2 ) 1996 For 50 Sq.Mmacsr ( Galvanised Steel Reinforced ) For Fitment Of Various Accessories 37 Supply, Installation And Testing Of 35 Sq Mm Xlpe Aluminum H.Tcable ( Abc Type ) Of 11 Kv Grade With Following Specs.Size ( Cross Sectional Area In Sq Mm ) = 3×35 With Reinforced Wirephases:Red, Yellow, Blue 38 Providing And Fitting Of Anchoring Clampscomprising Clamp Body , Plastic Wedge, Steel Bill Bracket , Straps And Buckles Or Nuts And Bolts Required For Holding Of 3 – Core , 35 Sq. Mm H.T Ab Cable. 39 P / F Of 11 Kv Cable Termination Kit For Connecting 35 Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 40 Fabrication, Providing And Fitting Of 15Hp Modularmotor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories:Rest Specification As Per Sbd Clause 43C 41 Providing, Fitting, Testing And Commissioning Ofvoltage Stabilizeras Per Specifications Below: Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supplyrest Technincal Specification As Per Cluase 45 Of Sbrating::30Kva 42 Providing And Fitting Of 3-Core Flatsubmersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipments . The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. Size: 10Sq.Mm 43 Providing And Fitting Of 2 / 3 / 3.5 / Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminium Cable Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc.Note:- The Cable Terminal Ends For Connection To Switchgear At Various Requisite Points Shall Be Al. Thimbles Of Dowel’S Make And Of Appropriate Size And Connected By Hydraulic Crimp Tool Only.Rest Specifications As Per Clause 71 Of Sbdi ) 10Sqmm, 2 Core Lt 1.1Kv 44 Ii ) 50Sqmm, 3.5 Core Lt 1.1 Kv 45 Providing And Fitting Of Single-Core, Copper Pvc Insulated Cable, Conforming To Is: 694 Part 1St For Internal Connections With Crimping, Taping Etc.Note:- The Cable Terminal Ends For Connection To Switchgear At Various Requisite Points Shall Be Copper Thimbled And Of Appropriate Size And Connected By Hydraulic Crimp Tool Only.Specifications:Single Core Pvc Insulated 25Sqmmrest Specification As Per Sbd Clause 67 46 P / I Of Earthing Station For Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size:80 Mm Dia , Length :2000 Mmback Fill Compound :30 Kg 47 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: -Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 48 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet, 2 Nos Including Cutting , Fixingall Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 49 Providing Of Good Qualityconvence And Utility Items. Technical Specification And Item Details Are As Per Cluase 58 Of Sbd. 50 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 51 Providing Of Bamboo Ladders 18 Feet Long Along With 15 Feet Long Link Rods And Ht Glove Pair ( 01 No Each ) 52 Providing Of 1 Kw Heat Convector For Operators For Winter Season. 53 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site. Size: 4’×6’ Out Ms Angle Of 40X 40X 5Of 36 Rft And Ms Sheet Of 1 Mmthicktotal Weight Of50.16 Kgs 54 Providing And Fitting Of 18 Sweep Seiling Fan Of Standard Make Including The Cost Of All Cables, Connections, Controlsystem Along With The Speed Regulator With Control Switches For The Power Supply 55 Carriage Of Sand , Stone Aggregate By Mechanical Transportincluding Loading, Unloadingand Stacking ( Average Distance-5Km ) 56 Carriage Of Soling Stone By Mechanical Transportincluding Loading, Unloadingand Stacking ( Average Distance-5Km ) 57 Carriage Of Cement / Steel / Cgi Sheet / Gi Pipes Below 100Mm Dia And Other Heavy Materials By Mechanicaltransportincluding Loading , Unloadingand Stacking ( Average Distance -25Km )

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 02-05-2023 Extension Notice Date 10-05-2023
2 11-05-2023 Extension Notice II Date 16-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 46840.0 /-
Tender Value
INR 23.42 Lakhs /-