| 1 | Wiring for light point/fan point/exhaust fan point/callbellpoint with 1.5sq.mmFLRS PVC insulated copper conductor single core cable insurface/ recessed medium class PVC conduit,with modular switch , modular plate,suitable GI box and earthing the point with 1.5sq. mm FLRS PVC insulated copper conductor single core cable etc as required make:- Anchor,Polycab etc. |
| 2 | Supply & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB , \"C\" curve including connections, painting etc. as required |
| 3 | Supply & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switches, connections etc, as required |
| 4 | Supply & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 2 nos of 3pin 5/6 A modular socket outlet and 2 Nos 5/6 A modular switches, connections etc, as required |
| 5 | Wiring for light / power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 Sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 6 | Wiring for circuit/submain wiring alongwith earth wire the following sizes of FRLS PVS insulated copper conductor. Single core cable in surface/recessed medium class PVC conduit as required make:-Anchor,Polycab etc.2 x 2.5 sq.mm + 1 x 2.5 sq. mm earth wire |
| 7 | Wiring for circuit/submain wiring alongwith earth wire the following sizes of FRLS PVS insulated copper conductor. Single core cable in surface/recessed medium class PVC conduit as required make:-Anchor,Polycab etc.2 x 6 sq.mm + 1 x 6.0 sq. mm earth wire |
| 8 | Wiring for circuit/submain wiring alongwith earth wire the following sizes of FRLS PVS insulated copper conductor. Single core cable in surface/recessed medium class PVC conduit as required make:-Anchor,Polycab etc.4 x 16.0 sq.mm + 2 x6.0 sq. mm earth wire |
| 9 | Supply & drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existingsurface / recessed steel / PVC conduit as required. 1x1.5 sq.mm |
| 10 | Supply & fixing of surface mounted 18/20 watt LED batten tube fitting Alumunium Housing 4 feet long including connections etc as required. |
| 11 | Supply & fixing of surface mounted 18/20 watt LED circular / square Down Lighter includingconnections etc as required. |
| 12 | Supply and fixing of Ceiling fan of double ball bearing type with 2.25 mfd condenser and down rod upto 4\" long on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. 1200 mm |
| 13 | supplying and fixing of following sizes exhaust fan with pvc blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. 300 mm sweep exhust fan heavy duty. |
| 14 | Supplying & fixing 5amps to 32 amps rating 240/415) volts\"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.Single Pole |
| 15 | Supplying & fixing 5amps to 32 amps rating 240/415) volts\"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.Single pole & Neutral |
| 16 | Supplying and fixing following rating 240/415 volts \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. as required. SPN 40 Amp |
| 17 | Supplying and fixing following rating 240/415 volts \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. as required. TPN 63 Amp |
| 18 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 19 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V,on surface/ recess. complete with linned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without 4 way (4 + 12 ) Double door |
| 20 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V,on surface/ recess. complete with linned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without 12 way Double door |
| 21 | Supplying and fixing, following size/ modules, GIbox alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mm x 75mm) |
| 22 | Supplying and fixing, following size/ modules, GIbox alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mm x 75mm) |
| 23 | Supplying and fixing, following size/ modules, GIbox alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mm x 75mm) |
| 24 | Supplying and fixing, following size/ modules, GIbox alongwith modular base & cover plate for modular switches in recess etc as required.B Module (125mm x 125mm) |
| 25 | Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connections but excluding modular plate etc, as required. 5/6 amp switch |
| 26 | Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connections but excluding modular plate etc, as required.15/16 amp switch |
| 27 | Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connections but excluding modular plate etc, as required. 3 pin 5/6 amp socket outlet |
| 28 | 6 pin 15/16 amp socket outlet |
| 29 | Bell push |
| 30 | Supply and fixing (two module ) stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required . |
| 31 | Supply and fixing of modular blanking plate on the existing modular plate & switch box excluding plate as required . |
| 32 | Supply and fixing of following LED type Street lights including connections etc as required Complete with G.I bracket 70 watt |
| 33 | Supply , installation, testing & commissioning of maintenance free copper earthing system with 2mtrs Electrode 40mm dia with minimum 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leachingports at the ends. The electrode shall be surrounded by suitable powdered from BEE MOIST so as to provide maximumcontact between the electrode and the compound . the compound should be eco-friendly the earthingb pit should be covered with PVC cover |
| 34 | Providing and fixing 25mm x 3mm copper strip on surface or in recess for connections. etc as required |
| 35 | Fabrication, supplying. installation testing and commissionin of following pannel CPRI approved made out of 2mm thick MS. sheet. floor/wall mounted, vermin and dust proof, indoor/outdoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly powder coated and providing and fixing of suitable rating bus bars. and other accessories likevoltmeter, ammeter, indicating lamps, selector switches, MCB strips etc. along-with provision of space for MCCB\"s, C.O.S etc as required. |
| 36 | 200 A,25KA,FPMCCB |
| 37 | Aluminium Bus bar 200 amp 4 strip. |
| 38 | Aluminium Bus bar 400 amp 4 strip. |
| 39 | Change over Switch 125amp front operatable |
| 40 | Digital Metering devices , comprising of Voltmetre,Ammetre, Selector Switch , indicating Lamp , CT Set and MCB strip of suitable size as required. |
| 41 | Supplying installation testing and commissioning of XLPE insulated and PVC sheathed / power cable of 1.1 KV grade of following size in ground/.cable tray as per site conditions as required. 150 Sq. mm x 3.5 core Armoured |
| 42 | Supplying and fixing of Musical Bell including making complete connections etc. as required. ( Make as per annexur enclosed ) |
| 43 | Supply and installation of tubular battery 180AH (Luminious) alongwith trolly (48 months warranty ) |
| 44 | Supply & installation Inverter 1800/2000 VA (Luminious ) |