}

Bids Are Invited For 1 O And M Of Hvac System As Per Item Specification Document Item No. 01 Page No. 232 2 Camc 4Nosx600 Tr Chiller As Per Item Specification Document Item No. 02 Page No. 232 3 Camc 1No.Sx400 Tr Chiller As Per Item Specification Do, SOUTH goa-Goa

Boards / Undertakings / PSU has published Bids Are Invited For 1 O And M Of Hvac System As Per Item Specification Document Item No. 01 Page No. 232 2 Camc 4Nosx600 Tr Chiller As Per Item Specification Document Item No. 02 Page No. 232 3 Camc 1No.Sx400 Tr Chiller As Per Item Specification Do. Submission Date for this Tender is 12-04-2023. Packaging Material Tenders in SOUTH goa Goa. Bidders can get complete Tender details and download the document.




Tender Notice

37200799
Bids Are Invited For 1 O And M Of Hvac System As Per Item Specification Document Item No. 01 Page No. 232 2 Camc 4Nosx600 Tr Chiller As Per Item Specification Document Item No. 02 Page No. 232 3 Camc 1No.Sx400 Tr Chiller As Per Item Specification Do
Open Tender
Indian
Goa
South Goa
12-04-2023

Tender Details

Bids Are Invited For 1 O And M Of Hvac System As Per Item Specification Document Item No. 01 Page No. 232 2 Camc 4Nosx600 Tr Chiller As Per Item Specification Document Item No. 02 Page No. 232 3 Camc 1No.Sx400 Tr Chiller As Per Item Specification Document Item No. 03 Page No. 233 4 Camc Anciliary Equipments Of Hvac System As Per Item Specification Document Item No. 04 Page No. 233 5 Quarterly Maintenance Visit By Oem / Authorised Dealer For Bms As Per Item Specification Document Item No. 05 Page No. 233 6 Treatment And Analysis Of Hvac Condensor Water As Per Item Specification Document Item No. 06 Page No. 234 7 Treatment And Analysis Of Hvac Chilled Water As Per Item Specification Document Item No. 07 Page No. 234 8 Replacement Of Old Wornout Ahu Air Filter As Per Item Specification Document Item No. 08 Page No. 234 9 Replacement Of Ci Butterfly Valve For Condensor Chilled Water Including Dismantling Of Faulty Valve-500 Mm Dia Valve As Per Item Specification Document Item No. 9.01 Page No. 234 10 Replacement Of Ci Butterfly Valve For Condensor Chilled Water Including Dismantling Of Faulty Valve-400 Mm Dia Valve As Per Item Specification Document Item No. 9.02 Page No. 234 11 Replacement Of Ci Butterfly Valve For Condensor Chilled Water Including Dismantling Of Faulty Valve-350 Mm Dia Valve As Per Item Specification Document Item No. 9.03 Page No. 234 12 Replacement Of Ci Butterfly Valve For Condensor Chilled Water Including Dismantling Of Faulty Valve-300 Mm Dia Valve As Per Item Specification Document Item No. 9.04 Page No. 234 13 Replacement Of Ci Butterfly Valve For Condensor Chilled Water Including Dismantling Of Faulty Valve-250 Mm Dia Valve As Per Item Specification Document Item No. 9.05 Page No. 234 14 Replacement Of Ci Butterfly Valve For Condensor Chilled Water Including Dismantling Of Faulty Valve-200 Mm Dia Valve As Per Item Specification Document Item No. 9.06 Page No. 234 15 Replacement Of Ci Butterfly Valve For Condensor Chilled Water Including Dismantling Of Faulty Valve-150 Mm Dia Valve As Per Item Specification Document Item No. 9.07 Page No. 235 16 Supply, Fabrication, Installation, Testing And Commissioning Of Site Fasbricated Gss Sheet Thickness 24 Swg As Per Item Specification Document Item No. 10.01 Page No. 235 17 Supply, Fabrication, Installation, Testing And Commissioning Of Site Fasbricated Gss Sheet Thickness 22 Swg As Per Item Specification Document Item No. 10.02 Page No. 235 18 Supply, Fabrication, Installation, Testing And Commissioning Of Site Fasbricated Gss Sheet Thickness 20 Swg As Per Item Specification Document Item No. 10.03 Page No. 235 19 Supply And Fixing 50 Mm Thickness Closed Cell Nitrile Rubber With ( Class 0 ) Insulation Provided With Uv Protected Aluminium Based Cladding With Cold Setting Adhesive On Exposed Outdoor Ducting After Removal Of Existing Glasswool Insulation And Cladding As Per Item Specification Document Item No. 11 Page No. 235 20 Supply And Fixing 50 Mm Thickness Closed Cell Nitrile Rubber With ( Class 0 ) Insulation With Factory Laminated Aluminium Foil By Applying Suitable Cold Setting Adhesive On Indoor Ducting Above False Ceiling After Removal Of Existing Glass Wool Insulation As Per Item Specification Document Item No. 12 Page No. 235 21 Overhauling Compressor Of The Chiller No. 4 Of Ms. Carrier Make Model 19Xr50524362dh52 , Replacement Damaged Parts As Per Item Specification Document Item No. 13 Page No. 236 22 Rectification Of Central Bms So That All The Parameters, Status Set Points Can Be Monitored And Controlled As Per Item Specification Document Item No. 14 Page No. 236. 23 Supply Of Uv Lamp For Existing Uvgi Provided Inside Ahu As Per Item Specification Document Item No.15.01 Page No. 237 24 Supply Of Reflector For Existing Uvgi Provided Inside Ahu As Per Item Specification Document Item No.15.02 Page No. 237 25 Supply Of Uv Ballast For Existing Uvgi Provided Inside Ahu As Per Item Specification Document Item No.15.03 Page No. 237 26 Cmc Of Window Split Type Air-Conditioners Cassette Type Of All Makes Of 1.5 Ton - 2.0 Ton Capacity With Single Phase Supply At Different Locations Including Providing Replacement Of All Faulty Components Consumables Spares Etc As And When Required For First Year As Per Item Specification Document Item No.16.01 Page No. 237 27 Cmc Of Window Split Type Air-Conditioners Cassette Type Of All Makes Of 1.5 Ton - 2.0 Ton Capacity With Single Phase Supply At Different Locations Including Providing Replacement Of All Faulty Components Consumables Spares Etc As And When Required For Second Year As Per Item Specification Document Item No.16.02 Page No. 237 28 Comprehensive Maintenance Contract Of Split Multi-Split Type Cassette Typetower Type Airconditioners Of All Makes Of 3.0 Ton Capcity With 3 Phase Supply Including Providing Replacement Of Faulty Components Consumables Spares Etc As And When Required For First Year As Per Item Specification Document Item No.17.01 Page No. 237 29 Comprehensive Maintenance Contract Of Split Multi-Split Type Cassette Type Tower Type Airconditioners Of All Makes Of 3.0 Ton Capcity With 3 Phase Supply Including Providing Replacement Of Faulty Components Consumables Spares Etc As And When Required For Second Year As Per Item Specification Document Item No.17.02 Page No. 237 30 Comprehensive Maintenance Contract For Vrf ( Variable Refrigerant Flow ) System Consisting Of 39 Nos. Indoor Units Varying From1 Ton - 2 Ton Rating, And 3 Nos. 22 Hp Capacity Air Cooled Out Door Units Including All Related Accessories Installed In New Admin Block At Goa Airport On Monthly Basis As Per Item Specification Document Item No.18 Page No. 238 31 Comprehensive Maintenance Contract For Vrf ( Variable Refrigerant Flow ) System Consisting Of 5 Nos. Indoor Units - 2 Ton Capacity, And 2 Nos. Casette Unit Of 3 Ton Capacity And 22 Hp Capacity Air Cooled Out Door Units Including All Related Accessories Installed In Apron Control Room, Etc At Goa Airport On Monthly Basis As Per Item Specification Document Item No.19 Page No. 238 32 Comprehensive Maintenance Contract For Vrv ( Variable Refrigerant Volume ) System Consisting Of 03 Nos. Of 3.2 Tr Cassette A / C Indoor Unit, And 02 Nos. 6Hp Air Cooled Varable Refrigerant Valve With Scroll Compressor Inverter Drivers Outdoor Units Including All Related Accessories Installed In Aocc Room At Goa International Airport On Monthly Basis As Per Item Specification Document Item No.20 Page No. 238 33 Comprehensive Maintenance Contract For Vrv ( Variable Refrigerant Volume ) System Consisting Of12 Nos Outdoor Units Of 17.7Kw Each Rating, And 6 Nos. Indoor ( 13000+ / -2% Cfm ) Ahu Consisting Fan Prefilter, Gas Charging , Coil Tubes Fins Etc Including All Related Accessories Installed In Dsha At Goa Airport On Monthly Basis As Per Item Specification Document Item No.21 Page No. 238 34 Comprehensive Maintenance Contract Of Self Standing Water Dispenser Of All Makes At Different Locations Including Providing Or Replacement Of Faulty Components / Consumables / Spares Etc When Required As Per Item Specification Document Item No.22 Page No. 238 35 Comprehensive Maintenance Contract Of Storage Type Water Dispenser Cum Purifier, Online Free Standing Type With Ambient, Hot And Cold Water Dispensor Of Make Eureka Forbes Including Providing Or Replacement Of Faulty Components / Comsumables / Spares ) Refrigerant Gas Etc As And When Required As Per Item Specification Document Item No.23 Page No. 239 36 Comprehensive Maintenance Contract Of Water Cooler Cum Purifier Of Stainless Steel - Of Various Make And Capacity Installed At Different Locations Including Providing Or Replacement Of Faulty Components / Consumable / Spares Etc When Required As Per Item Specification Document Item No.24 Page No. 239 37 Comprehensive Maintenance Contract Of Water Purifier Of All Make At Different Locations Including Providing Or Replacement Of Faulty Components / Consumable / Spares Etc When Required As Per Item Specification Document Item No.25 Page No. 239 38 Comprehensive Maintenance Contract Of Water Coolers Of All Makes Of 40 / 80 And 80 / 120 Litre Etc. Capacity Respectively At Different Locations Including Providing Or Replacement Of Faulty Components / Components / Spares Etc When Required As Per Item Specification Document Item No.26 Page No. 239 39 Dismantling Of Existing Split A / C / Cassette A / C / Floor Mounted A / Cs Of 1.5 Tr To 3Tr ( Indoor And Outdoor Unit ) Including Pumping Down Of Gas, Dismantling Of Refrigrent Pipeline, Drain Pipe Power Cable Etc And Transporting To Stores As Per Directions Of Engineering Incharge As Per Item Specification Document Item No.27 Page No. 239 40 Reinstallation, Testing And Commissioning Of Existing Split A / C / Cassette A / C / Floor Mounted A / Cs Of 1.5 Tr To 3Tr ( Indoor And Outdoor Unit A / Cs Will Be Provided From Stores Including Refrigerant Pipeline, Power Cable Etc And Transporting To Stores ( The Reinstallation Will Include Providing And Laying Of Insulated Refrigerant Pipes Of Relevant Size ( Upto 3 Mtrs ) , Insulated Drain Pipe ( Upto 3 Mtrs ) , Power Cabling Between Indoor And Outdoor, Wrapping Of Refrigerant And Drain Pipe With Vinyl Tape, Gas Charging With Refrigerant Etc As Required As Per Item Specification Document Item No.28 Page No. 239 41 Providing And Fixing Of Extra Length Refrigerant Pipeline Suction And Discharge Of Relevant Size Suitable For Execution Of Item No Above Item Including Providing Insulation And Vinyl Wrapping Etc As Required As Per Item Specification Document Item No.29 Page No. 239 42 Providing And Fixing Of Extra Length Drain Pipeline Suction And Discharge Of Relevant Size Suitable For Execution Of Item As Above Including Providing Insulation And Vinyl Wrapping Etc As Required As Per Item Specification Document Item No.30 Page No. 240 Total Quantity : 1901

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail