}

Tender For Item Rate Running Contract For Annual Electrical Works And Supply Of Electrical Items For The Year 2023-24 At Actrec, kharghar-Maharashtra

Tata Memorial Centre has published Tender For Item Rate Running Contract For Annual Electrical Works And Supply Of Electrical Items For The Year 2023-24 At Actrec. Submission Date for this Tender is 10-05-2023. Uniform Tenders in kharghar Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

37174900
Corrigendum : Tender For Item Rate Running Contract For Annual Electrical Works And Supply Of Electrical Items For The Year 2023-24 At Actrec
Open Tender
Indian
Maharashtra
Kharghar
10-05-2023

Tender Details

Item Rate Running Contract For Annual Electrical Works And Supply Of Electrical Items For The Year 2023-24 At Actrec-1 Point Wiring 1.1 Sitc Of Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bellpoint With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable In Surface / Recessed Steel Conduit, Withmodular Switch, Modular Plate, Suitable Gi Box And Earthing Thepoint With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable Etc. As Required. 1.2 Sitc Of Secondary Light Point From First Light Point To Second Light Point Connected In The Same Switch Ie Looping Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable In Surface / Recessed Steel Conduit, Withmodular Switch, Modular Plate, Suitable Gi Box And Earthing Thepoint With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable Etc. As Required. 1.3 Primary Point Wiring As 1.1 , Modular 2 Module Fan Regulator 250W 1.4 Sitc Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvcinsulated Copper Conductor Single Core Cable Etc. As Required. 1.5 Sitc Of Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bellpoint With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable In Surface / Recessed Medium Class Pvcconduit, With Modular Switch, Modular Plate, Suitable Gi Boxand Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulatedcopper Conductor Single Core Cable Etc. As Required. 1.6 Sitc Of Secondary Light Point From First Light Point To Second Light Point Connected In The Same Switch Ie Looping Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable In Surface / Recessed Medium Class Pvcconduit, With Modular Switch, Modular Plate, Suitable Gi Boxand Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulatedcopper Conductor Single Core Cable Etc. As Required. 1.7 Primary Point Wiring As Per 1.5 Modular 2 Module Fan Regulator 250W 1.8 Sitc Of Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cableetc. As Required. 2.1 Fan Hookfabrication, Supply & Fixing Of Ms Fan Hook Box Having 2 Coats Of Red Oxide Finish Made Out Of 16 Mm Rod & Fixing In Ceiling With Anchor Fastner Including Digging, Cementing, Plastering, Finishing It To Match With The Background Complete In All Respects ( Only Supply ) 2.2 Fabrication, Supply & Fixing Of Ms Fan Hook Box Having 2 Coats Of Red Oxide Finish Made Out Of 16 Mm Rod & Fixing In Ceiling With Anchor Fastner Including Digging, Cementing, Plastering, Finishing It To Match With The Background Complete In All Respects ( Only Labour ) 2.3 Fabrication, Supply & Fixing Of Ms Fan Hook Box Having 2 Coats Of Red Oxide Finish Made Out Of 16 Mm Rod & Fixing In Ceiling With Anchor Fastner Including Digging, Cementing, Plastering, Finishing It To Match With The Background Complete In All Respects ( Composite ) 2.4 Fabrication, Supply & Fixing Of Ms Fan Hook Made Out Of 16 Mm Rod & Fixing In Ceiling Using Double Anchor Fasteners. Complete In All Respects ( Only Supply ) 2.5 Fabrication, Supply & Fixing Of Ms Fan Hook Made Out Of 16 Mm Rod & Fixing In Ceiling Using Double Anchor Fasteners. Complete In All Respects ( Only Labour ) 2.6 Fabrication, Supply & Fixing Of Ms Fan Hook Made Out Of 16 Mm Rod & Fixing In Ceiling Using Double Anchor Fasteners Complete In All Respects. ( Composite ) 2.7 Supply Of Fan Down Rod Made Out Of Gi Conduit Pipes Of 20 Mm Or Suitable With Threading, Boring Etc. Complete Up To 18Inch Long Etc. Complete In All Respect. ( Only Supply ) 2.8 Fixing Fan Down Rod Made Out Of Gi Conduit Pipes Of 20 Mm Or Suitable With Threading, Boring Etc. Complete Up To 18 Inch Long Etc. Complete In All Respect. ( Only Labour ) 2.9 Supply & Fixing Fan Down Rod Made Out Of Gi Conduit Pipes Of 20 Mm Or Suitable With Threading, Boring Etc. Complete Up To 18Inch Long Etc. Complete In All Respect. ( Composite ) 3 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With Thefollowing Sizes Of Frls Pvc Insulated Copper Conductor, Singlecore Cable In Surface / Recessed Steel Conduit As Required. 3.1 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 3.2 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 3.3 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 3.4 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 3.5 2 X 10 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 3.6 2 X 16 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 3.7 4 X 2.5 Sq. Mm + 2 X 2.5 Sq. Mm Earth Wire 3.8 4 X 4 Sq. Mm + 2 X 4 Sq. Mm Earth Wire 3.9 4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 3.11 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 3.12 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 4 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With Thefollowing Sizes Of Frls Pvc Insulated Copper Conductor, Singlecore Cable In Surface / Recessed Medium Class Pvc Conduit Asrequired. 4.1 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 4.2 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 4.3 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 4.4 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 4.5 2 X 10 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 4.6 2 X 16 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 4.7 4 X 2.5 Sq. Mm + 2 X 2.5 Sq. Mm Earth Wire 4.8 4 X 4 Sq. Mm + 2 X 4 Sq. Mm Earth Wire 4.9 4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 4.11 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 4.12 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 6.1 Supply & Fixing Of Casing Capping Of Following Suitable Size With Screws, Rawal Plug Etc. Along With All Accessories Complete In All Respect On Any Hard Surface / Wall / Trench / Ceiling Etc. Complete As Per Instructions Of Eic. 6.1.1 Half Inch ( Only Supply ) 6.1.2 Half Inch ( Only Labour ) 6.1.3 Half Inch ( Composite ) 6.1.4 Threefouth Inch ( Only Supply ) 6.1.5 Threefouth Inch ( Only Labour ) 6.1.6 Threefouth Inch ( Composite ) 6.1.7 1Inch ( Only Supply ) 6.1.8 1Inch ( Only Labour ) 6.1.9 1Inch ( Composite ) 6.1.10 1.25Inch ( Only Supply ) 6.1.11 1.25Inch ( Only Labour ) 6.1.12 1.25Inch ( Composite ) 6.1.13 1.50Inch ( Only Supply ) 6.1.14 1.50Inch ( Only Labour ) 6.1.15 1.50Inch ( Composite ) 6.1.16 2.0 Inch ( Only Supply ) 6.1.17 2.0 Inch ( Only Labour ) 6.1.18 2.0 Inch ( Composite ) 7.1 Fixing Of Pvc Conduit / Truncking. Supply & Fixing Of Pvc Rigid Conduit Of Following Suitable Size With Spacers & Saddles Screws, Rawal Plug Etc. Along With All Accessories Complete In All Respect On Any Hard Surface / Wall / Trench / Ceiling Etc. Compete As Per Instruction Of Eic. 7.1.1 12.5 Mm ( Only Supply ) 7.1.2 12.5 Mm ( Only Labour ) 7.1.3 12.5 Mm ( Composite ) 7.1.4 20 Mm ( Only Supply ) 7.1.5 20 Mm ( Only Labour ) 7.1.6 20 Mm ( Composite ) 7.1.7 25 Mm ( Only Supply ) 7.1.8 25 Mm ( Only Labour ) 7.1.9 25 Mm ( Composite ) 7.1.10 32 Mm ( Only Supply ) 7.1.11 32 Mm ( Only Labour ) 7.1.12 32 Mm ( Composite ) 7.1.13 40 Mm ( Only Supply ) 7.1.14 40 Mm ( Only Labour ) 7.1.15 40 Mm ( Composite ) 7.1.16 50 Mm ( Only Supply ) 7.1.17 50 Mm ( Only Labour ) 7.1.18 50 Mm ( Composite ) 7.2 Providing & Fixing Pvc Trucking Of Following Sizes Along With All Accessories Complete In All Respect, All As Directed By O-I-C, Es. 7.2.1 50 X 50 X 2 Mm ( Only Supply ) 7.2.2 50 X 50 X 2 Mm ( Only Labour ) 7.2.3 50 X 50 X 2 Mm ( Composite ) 7.2.4 100 X 50 X 2 Mm ( Only Supply ) 7.2.5 100 X 50 X 2 Mm ( Only Labour ) 7.2.6 100 X 50 X 2 Mm ( Composite ) 8.1 Laying Of Bunch Of Wires. Supplying & Pulling Wires With 1.5 Sq. Mm Solid / Stranded Copper Insulated Wire With 1.1 Kv Grade With Isi Mark Laid In Conduit / Casing Capping Inside Bus Bars / Switches Etc, With Necessary Bakelite / Rubber Bushings / Sleeves & Connected To Apparatus An Approved Manner With Bottle Type / Nut Type Cable Terminals Of Adequate Capacity. 8.1.1 Same As Item No 8.1 But For 2 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark. ( Only Supply ) 8.1.2 Same As Item No 8.1 But For 2 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Only Labour ) 8.1.3 Same As Item No 8.1 But For 2 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Composite ) 8.1.4 Same As Item No 8.1 But For 3 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark. ( Only Supply ) 8.1.5 Same As Item No 8.1 But For 3 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Only Labour ) 8.1.6 Same As Item No 8.1 But For 3 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Composite ) 8.1.7 Same As Item No 8.1 But For 4 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark. ( Only Supply ) 8.1.8 Same As Item No 8.1 But For 4 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Only Labour ) 8.1.9 Same As Item No 8.1 But For 4 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Composite ) 8.1.10 Same As Item No 8.1 But For 5 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark. ( Only Supply ) 8.1.11 Same As Item No 8.1 But For 5 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Only Labour ) 8.1.12 Same As Item No 8.1 But For 5 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Composite ) 8.1.13 Same As Item No 8.1 But For 6 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark. ( Only Supply ) 8.1.14 Same As Item No 8.1 But For 6 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Only Labour ) 8.1.15 Same As Item No 8.1 But For 6 X 1.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Composite ) 8.2 Supplying & Pulling Wires With 2.5 Sq. Mm Solid / Stranded Copper Pvc Insulated Wire With Kv Grade With Isi Mark Laid In Conduit / Casing Capping Inside Bus Bars / Switches Etc, With Necessary Bakelite / Rubber Bushings / Sleeves & Connected To Apparatus In An Approved Manner With Bottle Type / Nut Type Cable Terminals Of Adequate Capacity. 8.2.1 Same As Item No 8.2 But For 2 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark. ( Only Supply ) 8.2.2 Same As Item No 8.2 But For 2 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Only Labour ) 8.2.3 Same As Item No 8.2 But For 2 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Mark.. ( Composite ) 8.2.4 Same As Item No 8.2 But For 3 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.2.5 Same As Item No 8.2 But For 3 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Only Labour ) 8.2.6 Same As Item No 8.2 But For 3 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Composite ) 8.2.7 Same As Item No 8.2 But For 4 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.2.8 Same As Item No 8.2 But For 4 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Only Labour ) 8.2.9 Same As Item No 8.2 But For 4 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Composite ) 8.2.10 Same As Item No 8.2 But For 5 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.2.11 Same As Item No 8.2 But For 5 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Only Labour ) 8.2.12 Same As Item No 8.2 But For 5 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Composite ) 8.2.13 Same As Item No 8.2 But For 6 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.2.14 Same As Item No 8.2 But For 6 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Only Labour ) 8.2.15 Same As Item No 8.2 But For 6 X 2.5 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Composite ) 8.3 Supplying & Pulling Wires With 4 Sq. Mm Solid / Stranded Copper Pvc Insulated Wire With 1.1 Kv Grade With Isi Mark Laid In Conduit / Casing Capping Inside Bus Bars / Switches Etc, With Necessary Bakelite / Rubber Bushings / Sleeves & Connected To Apparatus In An Approved Manner With Bottle Type / Nut Type Cable Terminals Of Adequate Capacity. 8.3.1 Same As Item No 8.3 But For 2 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.3.2 Same As Item No 8.3 But For 2 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Labour ) 8.3.3 Same As Item No 8.3 But For 2 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Composite ) 8.3.4 Same As Item No 8.3 But For 3 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.3.5 Same As Item No 8.3 But For 3 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Labour ) 8.3.6 Same As Item No 8.3 But For 3 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Composite ) 8.3.7 Same As Item No 8.3 But For 4 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.3.8 Same As Item No 8.3 But For 4 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Labour ) 8.3.9 Same As Item No 8.3 But For 4 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Composite ) 8.3.10 Same As Item No 8.3 But For 5 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.3.11 Same As Item No 8.3 But For 5 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Labour ) 8.3.12 Same As Item No 8.3 But For 5 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Composite ) 8.3.13 Same As Item No 8.3 But For 6 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.3.14 Same As Item No 8.3 But For 6 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Labour ) 8.3.15 Same As Item No 8.3 But For 6 X 4 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Composite ) 8.4 Supplying & Pulling Wires With 6 Sq. Mm Solid / Stranded Copper Pvc Insulated Wire With 1.1 Kv Grade With Isi Mark Laid In Conduit / Casing Capping Inside Bus Bars / Switches Etc, With Necessary Bakelite / Rubber Bushings / Sleeves & Connected To Apparatus In An Approved Manner With Bottle Type / Nut Type Cable Terminals Of Adequate Capacity. 8.4.1 Same As Item No 8.4 But For 2 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.4.2 Same As Item No 8.4 But For 2 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Only Labour ) 8.4.3 Same As Item No 8.4 But For 2 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Composite ) 8.4.4 Same As Item No 8.4 But For 3 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.4.5 Same As Item No 8.4 But For 3 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Only Labour ) 8.4.6 Same As Item No 8.4 But For 3X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Composite ) 8.4.7 Same As Item No 8.4 But For 4 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.4.8 Same As Item No 8.4 But For 4 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Only Labour ) 8.4.9 Same As Item No 8.4 But For 4X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Composite ) 8.4.10 Same As Item No 8.4 But For 5 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.4.11 Same As Item No 8.4 But For 5 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Only Labour ) 8.4.12 Same As Item No 8.4 But For 5 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Composite ) 8.4.13 Same As Item No 8.4 But For 6 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Only Supply ) 8.4.14 Same As Item No 8.4 But For 6 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark.. ( Only Labour ) 8.4.15 Same As Item No 8.4 But For 6 X 6 Sq. Mm-Copper Pvc Insulated Wire Of 1.1 Kv Grade With Isi Mark. ( Composite ) 9.1 Concealing Of Pipe Supplying & Laying Isi Mark Ms Pipe B Class Suitable Size Dia With Necessary Bends, Tees & Junction Boxes With Check Nuts Etc In Wall Or Ceiling With Making Groves & Plastering With Cement Mortar & Finishing The Surface To Match The Back Ground In R.C.C. Slab / Bricks Wall Etc With Continuous 14 Swg Tinned Bare Copper Wire As Earth Wire Erected With Copper Earth Clips Of 22 Swg 10 Mm At The End Of Every Threaded Piece To Make The Pipe Electrically Continuous In Approved Manner. Complete All As Per Instruction Of Eic. 9.1.1 Same As Item No 9.1 But For 20 Mm Size ( Only Supply ) 9.1.2 Same As Item No 9.1 But For 20 Mm Size ( Only Labour ) 9.1.3 Same As Item No 9.1 But For 20 Mm Size ( Composite ) 9.1.4 Same As Item No 9.1 But For 25 Mm Size ( Only Supply ) 9.1.5 Same As Item No 9.1 But For 25 Mm Size ( Only Labour ) 9.1.6 Same As Item No 9.1 But For 25 Mm Sizee ( Composite ) 9.1.7 Same As Item No 9.1 But For 32 Mm Size ( Only Supply ) 9.1.8 Same As Item No 9.1 But For 32 Mm Size ( Only Labour ) 9.1.9 Same As Item No 9.1 But For 32 Mm Sizee ( Composite ) 9.2 Supplying & Laying Isi Mark Gi Pipe B Class Suitable Size Dia With Necessary Bends, Tees & Junction Boxes With Check Nuts Etc In Wall Or Ceiling With Making Groves & Plastering With Cement Mortar & Finishing The Surface To Match The Back Ground In R.C.C. Slab / Bricks Wall Etc With Continuous 14 Swg Tinned Bare Copper Wire As Earth Wire Erected With Copper Earth Clips Of 22 Swg 10 Mm At The End Of Every Threaded Piece To Make The Pipe Electrically Continuous In Approved Manner. Complete All As Per Instruction Of Eic. 9.2.1 Same As Item No 9.2 But Isi Mark Gi Conduit 14 Swg 20 Mm Dia. ( Only Supply ) 9.2.2 Same As Item No 9.2 But Isi Mark Gi Conduit 14 Swg 20 Mm Dia. ( Only Labour ) 9.2.3 Same As Item No 9.2 But Isi Mark Gi Conduit 14 Swg 20 Mm Dia. ( Composite ) 9.2.4 Same As Item No 9.2, 25 Mm Dia Gi Same As Above ( Only Supply ) 9.2.5 Same As Item No 9.2, 25 Mm Dia Gisame As Above ( Only Labour ) 9.2.6 Same As Item No 9.2, 25 Mm Dia Gisame As Above ( Composite ) 9.2.7 Same As Item No 9.2, 32 Mm Diagi Same As Above ( Only Supply ) 9.2.8 Same As Item No 9.2, 32 Mm Diagi Same As Above ( Only Labour ) 9.2.9 Same As Item No 9.2, 32 Mm Diagi Same As Above ( Composite ) 9.3 Supplying & Laying Isi Mark Pvc Rigid Pipe Of Suitable Size Dia With Necessary Bends, Tees & Junction Boxes With Check Nuts Etc In Wall Or Ceiling With Making Groves & Plastering With Cement Mortar & Finishing The Surface To Match The Back Ground In R.C.C. Slab / Bricks Wall Etc With Continuous 14 Swg Tinned Bare Copper Wire As Earth Wire Erected With Copper Earth Clips Of 22 Swg 10 Mm At The End Of Every Threaded Piece To Make The Pipe Electrically Continuous In Approved Manner. Complete All As Per Instruction Of Eic. 9.3.1 Same As Item No 9.3 But Rigid Pvc Conduit With Isi Mark ( Is 9537 Part 3 ) 20 Mm Dia Heavy Gauge Same As Above ( Only Supply ) 9.3.2 Same As Item No 9.3 But Rigid Pvc Conduit With Isi Mark ( Is 9537 Part 3 ) 20 Mm Dia Heavy Gauge Same As Above ( Only Labour ) 9.3.3 Same As Item No 9.3 As Above But Rigid Pvc Conduit With Isi Mark ( Is 9537 Part 3 ) 20 Mm Dia Heavy Gauge Same As Above ( Composite ) 9.3.4 Same As Item No 9.3 But 25 Mm Dia Pvc Conduit ( Only Supply ) 9.3.5 Same As Item No 9.3 But 25 Mm Dia Pvc Conduit ( Only Labour ) 9.3.6 Same As Item No 9.3 But 25 Mm Dia Pvc Conduit ( Composite ) 9.3.7 Same As Item No 9.3But 32 Mm Dia Pvc Conduit ( Only Supply ) 9.3.8 Same As Item No 9.3But 32 Mm Dia Pvc Conduit ( Only Labour ) 9.3.9 Same As Item No 9.3But 32 Mm Dia Pvc Conduit ( Composite ) 9.4 In General Same As Item No 9.3 But As Applicable For Concealing The Pipes In Marble / Granite Flooring Or Wall, Of Following Suitable Sizes. 9.4.1 20 Mm Dia ( Only Supply ) 9.4.2 20 Mm Dia ( Only Labour ) 9.4.3 20 Mm Dia ( Composite ) 9.4.4 25 Mm Dia ( Only Supply ) 9.4.5 25 Mm Dia ( Only Labour ) 9.4.6 25 Mm Dia ( Composite ) 9.4.7 32 Mm Dia ( Only Supply ) 9.4.8 32 Mm Dia ( Only Labour ) 9.4.9 32 Mm Dia ( Composite ) 9.4.10 38 Mm Dia ( Only Supply ) 9.4.11 38 Mm Dia ( Only Labour ) 9.4.12 38 Mm Dia ( Composite ) 10.1 Area Lighting Fittings Covers Supply Fixing / Replacement Of Glass / Acrylic Covers For Various Street Light / Flood Light / Area Lighting Or Any Such Lighting Fittings Having Same Grade Of Glass / Acrylic All As Directed By O-I-C, Es. Agency Is Requested To See The Sample First And Adequate / Suitable Replacement Sall Be Done. Removed Covers / Parts Shall Be Returned To Actrec As It Is. 10.1.1 For Post Top Lantern ( Only Supply ) 10.1.2 For Post Top Lantern ( Only Labour ) 10.1.3 For Post Top Lantern ( Composite ) 10.1.4 Any Other Equivalent For Item No 10.1 Application But Non-Standred Lighting Fixture ( Only Supply ) 10.1.5 Any Other Equivalent For Item No 10.1 Application But Non-Standred Lighting Fixture ( Only Labour ) 10.1.6 Any Other Equivalent But For Item No 10.1 Appplication Non-Standred Lighting Fixture ( Composite ) 11.1 Pvc Flexible Conduit Supply & Laying / Replacement Of Pvc Flexible Conduit Conforming To Isi Standards & Approved Make With Required Number Of Coupling, Pvc Bushes, Check Nuts Etc Complete All As Per Instruction Of Eic. In Case Of Replacement, Removed Parts, Items Etc. Shall Be Returned To Actrec As It Is. 11.1.1 Same As Above 20 Mm Dia Same As Above ( Only Supply ) 11.1.2 Same As Above 20 Mm Diasame As Above ( Only Labour ) 11.1.3 Same As Above20 Mm Dia Same As Above ( Composite ) 11.1.4 Same As Above 25 Mm Dia Same As Above ( Only Supply ) 11.1.5 Same As Above 25 Mm Dia Same As Above ( Only Labour ) 11.1.6 Same As Above 25 Mm Dia Same As Above ( Composite ) 11.1.7 Same As Above 32 Mm Dia Same As Above ( Only Supply ) 11.1.8 Same As Above 32 Mm Dia Same As Above ( Only Labour ) 11.1.9 Same As Above 32 Mm Dia Same As Above ( Composite ) 11.1.10 Same As Above 40 Mm Dia Same As Above ( Only Supply ) 11.1.11 Same As Above 40 Mm Dia Same As Above ( Only Labour ) 11.1.12 Same As Above 40 Mm Dia Same As Above ( Composite ) 11.1.13 Same As Above 50 Mm Dia Same As Above ( Only Supply ) 11.1.14 Same As Above 50 Mm Dia Same As Above ( Only Labour ) 11.1.15 Same As Above 50 Mm Dia Same As Above ( Composite ) 12.1 Dismentling Dismantling / Removing The Existing Light, Fan, Bell, Independent Plug Point, Wiring Of All Types With Accessories, Switch Boards Etc To The Satisfaction Of In-Charge. All Dismantled / Removed / Scrap Material To Be Handed Over To Engg. Dept As It Is. ( Only Labour ) 12.2 Dismantling The Existing Mains Wires Of All Sizes, Make Running Through Pvc Casing Capping / Pipes / Ms Conduits Including Casing Capping / Pvc Pipes / Ms Pipes / Gi Pipes / Hgdwc Pipes / Pvc Or Metal Trunking Etc. ( Only Labour ) 12.3 Dismantling The Cables Of Following Sizes Without Damaging It With Glands, Cable End Boxes, Earthing, Saddles, Spacers & Clamps Etc & Cleaning The Surface Area & Hand Over To Engg. - In –Charge. ( Only Labour ) 12.3.1 1.5 Sq. Mm To 10 Sq. Mm ( Only Labour ) 12.3.2 16 Sq. Mm To 70 Sq. Mm ( Only Labour ) 12.3.3 Above 70 Sq. Mm ( Only Labour ) 12.4 Dismantling Of Distribution Board / Bus Bar Irrespective Of Size, Capacity / Ways Etc Complete With Angle Iron Frame & Making The Site Clear By Refilling The Holes Etc. & Finishing Matching To Background And Handing Over It To Actrec As It Is. ( Only Labour ) 12.5 Dismantling Ceiling Fan, Exhaust Fan, Wall / Cabin Fan / Fluorescent Lamp / Night Lamp Etc. With Accessories, Gi Down Rod, Frame Etc & Making The Site Clear & Finishing Matching To Background And Handing Over The Items To Actrec As It Is. ( Only Labour ) 12.6 Dismantling Existing Electric Geyser / Storage Type Water Heater Irrespective Of Size, Make, Including Brackets, Grouting Bolts Etc Refilling The Holes With Cement Mortar & Making The Site Clear And Handing Over It To Actre As It Is. ( Only Labour ) 12.7 Dismantling Of Smoke Detector / Response Indicator / Bg / Circuit Isolator / Ahu Cut Off, Putting Insulation On Exposed Ends Etc And Handing Nover It T Actrec As It Is. ( Only Labour ) 13.1 Rewinding Rewinding Of Table / Wall / Pedestal / Exhaust Fan Up To 300 Mm / Dip Freezer / Any Similar Application Motor Etc. Of All Types & Make Including Overhauling, Minor Repairs, Testing For The Original Speed Including Transportation, Removal From Point Of Fault & Refiitting Of The Same After Repairs For Inclusive Cost As Mentioned In The Following Item Nos. All The Items Removed While Repairs / Replacements Except Copper Coils Shall Be Handed Over / Returned To E-I-C As It Is. ( Composite ) 13.2 All General Gidelines As Per Item No 13.1 But For Rewinding Of Exhaust Fan Above Sweep 300 Mm. ( Composite ) 13.3 All General Guide Lines As Per Item No 13.1 But For Rewinding Of Ceiling Fan Motor Of All Makes And Types Including Overhauling, Including Minor Repairs, & Testing At Site Of Following Sizes. All The Removed / Replaced Parts / Items Shall Be Returned / Handed Over To E-I-C, Es. 13.3.1 900 Mm Sweep ( Composite ) 13.3.2 1200 Mm Sweep ( Composite ) 13.3.3 1400 Mm Sweep ( Composite ) 13.4 Rewinding Of Single / Three Phase Motors Rewinding Of Electric Single Phase / Three Phase Motors Not Covered In Item No 13.1 And 13.3, Winding With Copper Wire, Overhauling With Minor Repairs Along With The Replacement Of Minor Parts, Testing For The Original Speed & Guarantee Of Minimum 6 Months, Having Heneral Guidelines As Per Itam No 13.1 And 13.3, Allas Per The Instructions Of E-I-C, Es For Inclusive Cost As Mentioned In The Folloeing Various Items Nos. 13.4.1 Motors Up To Onefourth Hp Single Phase. ( Composite ) 13.4.2 Motors Up To Half Hp Single Phase. ( Composite ) 13.4.3 1 Hp Single Phase. ( Composite ) 13.4.4 2 Hp Single Phase ( Composite ) 13.4.5 Single Phase 3 Hp ( Composite ) 13.4.6 Up To 1 Hp 3 Phase ( Composite ) 13.4.7 2 Hp 3 Phase ( Composite ) 13.4.8 3 Hp 3 Phase ( Composite ) 13.4.9 5 Hp 3 Phase ( Composite ) 13.4.10 7.5 Hp 3 Phase ( Composite ) 13.4.11 10 Hp 3 Phase ( Composite ) 13.4.12 12.5 Hp 3 Phase ( Composite ) 13.4.13 15 Hp 3 Phase ( Composite ) 13.4.14 20 Hp 3 Phase ( Composite ) 13.4.15 25 Hp 3 Phase ( Composite ) 13.4.16 30 Hp 3 Phase ( Composite ) 13.4.17 40 Hp 3 Phase ( Composite ) 13.4.18 45 Hp 3 Phase ( Composite ) 13.4.19 50 Hp 3 Phase ( Composite ) 13.4.20 60 Hp 3 Phase ( Composite ) 13.4.21 5 Hp Submersible Pump, 3 Ph. ( Composite ) 13.4.22 3 Hp Submersible Pump 3 Ph ( Composite ) 13.4.23 2 Hp Submersible Pump 3 Ph ( Composite ) 13.4.24 2 Hp Submersible Pump 1 Ph ( Composite ) 14.1 Bearings Replacing The Worn Out / Unservicible Existing Ball Of Approved Make Of Single Phase-Three Phase Electric Motor / Other Relevent Applications Of All Types With Proper Alignment Of Shaft, Greasing / Oiling Etc & Testing At Site Sll As Per The Instructions Of E-I-C, Es. Removed / Replaced Bearings Shall Be Handed Over To E-I-C, Es As It Is. ( Gate Pass / Challans Are To Te Submitted To E-I-C, Es Each Time ) 14.1.1 2 Hp To 3 Hp ( Only Supply ) 14.1.2 2 Hp To 3 Hp ( Only Labour ) 14.1.3 2 Hp To 3 Hp ( Composite ) 14.1.4 4 Hp To 7.5 Hp ( Only Supply ) 14.1.5 4 Hp To 7.5 Hp ( Only Labour ) 14.1.6 4 Hp To 7.5 Hp ( Composite ) 14.1.7 10 Hp To 20 Hp ( Only Supply ) 14.1.8 10 Hp To 20 Hp ( Only Labour ) 14.1.9 10 Hp To 20 Hp ( Composite ) 14.1.10 25 Hp To 30 Hp ( Only Supply ) 14.1.11 25 Hp To 30 Hp ( Only Labour ) 14.1.12 25 Hp To 30 Hp ( Composite ) 14.1.13 35 Hp To 40 Hp ( Only Supply ) 14.1.14 35 Hp To 40 Hp ( Only Labour ) 14.1.15 35 Hp To 40 Hp ( Composite ) 14.1.16 45 Hp To 50 Hp ( Only Supply ) 14.1.17 45 Hp To 50 Hp ( Only Labour ) 14.1.18 45 Hp To 50 Hp ( Composite ) 14.1.19 60 Hp To 75 Hp ( Only Supply ) 14.1.20 60 Hp To 75 Hp ( Only Labour ) 14.1.21 60 Hp To 75 Hp ( Composite ) 14.2 Bearings / Bushings / Rotors 14.2.1 Replacing The Worn Out Existing Ball Bearing Of Table Fan / Wall Fan / Pedestal Fan / Ceiling Fan / Exhaust Fan / Dip Freezer Or Any Similar Application Motor Complete With Alignment Of Shaft & Testing At Site.Refer Guidelines As Per Item No - 14.1 ( Only Supply ) 14.2.2 Replacing The Worn Out Existing Ball Bearing Of Table Fan / Wall Fan / Pedestal Fan / Ceiling Fan / Exhaust Fan / Dip Freezer Or Any Similar Application Motor Complete With Alignment Of Shaft & Testing At Site.Refer Guidelines As Per Item No 14.1 ( Only Labour ) 14.2.3 Replacing The Worn Out Existing Ball Bearing Of Table Fan / Wall Fan / Pedestal Fan / Ceiling Fan / Exhaust Fan / Dip Freezer Or Any Similar Application Motor Complete With Alignment Of Shaft & Testing At Site. Refer Guidelines As Per Item No 14.1 ( Composite ) 14.2.4 Replacement Of Shaft For Table Fan / Wall Fan / Pedestal Fan / Ceiling Fan / Exhaust Fan / Dip Freezer Or Any Similar Application Motor Etc ( Only Labour ) Refer Guidelines As Per Item No 14.1 As Applicable For This Item. 14.2.5 Replacement Of Wound Rotor For Table Fan / Wall Fan / Pedestal Fan / Ceiling Fan / Exhaust Fan / Dip Freezer Or Any Similar Application Motor Etc.Refer Guidelines As Per Item No 14.1 As Applicable For This Item. ( Composite ) 14.2.6 Replacement Of Non-Wound Rotor For Table Fan / Wall Fan / Pedestal Fan / Ceiling Fan / Exhaust Fan / Dip Freezer Or Any Similar Application Motor Etc. Refer Guidelines As Per Item No 14.1 As Applicable For This Item. 14.2.7 Replacement Of Bushing For Table Fan / Wall Fan / Pedestal Fan / Ceiling Fan / Exhaust Fan / Dip Freezer Or Any Similar Application Motor Etc. Refer Guidelines As Per Item No 14.1 As Applicable For This Item. ( Only Supply ) 14.2.8 Replacement Of Bushing For Table Fan / Wall Fan / Pedestal Fan / Ceiling Fan / Exhaust Fan / Dip Freezer Or Any Similar Application Motor Etc. Refer Guidelines As Per Item No 14.1 As Applicable For This Item ( Only Labour ) 14.2.9 Replacement Of Bushing For Table Fan / Wall Fan / Pedestal Fan / Ceiling Fan / Exhaust Fan / Dip Freezer Or Any Similar Application Motor Etc. Refer Guidelines As Per Item No 14.1 As Applicable For This Item. ( Composite ) 14.2.10 Varnish Of Good Quality For General Motor Maintenance Etc With Prior Approval. ( Not Applicable As A Part Of Rewinding Etc. This Item Will Be Run Only When Application Will Be Done Exclusively ( Only Supply ) 14.2.11 Varnish Of Good Quality For General Motor Maintenance Etc With Prior Approval. ( Not Applicable As A Part Of Rewinding Etc. This Item Will Be Run Only When Application Will Be Done Exclusively ( Only Labour ) 14.2.12 Varnish Of Good Quality For General Motor Maintenance Etc With Prior Approval. ( Not Applicable As A Part Of Rewinding Etc. This Item Will Be Run Only When Application Will Be Done Exclusively ( Composite ) 14.2.13 Painting Of Old Fans, Tube Lights Fixtures, Motors Or Anyh Other Such Application Etc As Decided And Directed By E-I-C, Es With Enamel Paint After Coat Of Red Oxide Etc. ( Note: This Item Is Applicable Only When Specifically Required For Small / Midium Size Erquipment Coverd In Section No 14. Painting Included In Overhauling Or Repairs Of Any Electrical Equipment / Instrument / Machine Does Not Come Under This. ) ( Composite ) 14.2.14 Repairing Of Domestic Mixer / Grinder / Blender Or Any Other Eqvuivalant Domestic Applience Etc That Includes Replacement Of Indicators, Switches, Couplers, Oiling, General Servicing, Or Any Other Relvant Spare Part Etc For All Manufactures, All As Per Instructions Of Engineer-In-Charge. Replaced Material Shall Be Brought Back & Shall Be Submitted To E-I-C, Whereever Applicable ( Composite ) . 14.2.15 All As Per Item No 14.2.14 But For Replacement Of Bearing / Bushings / Blades Etc. ( Composite ) 14.2.16 All General Guidelines As Per Item No 14.2.14 But For Tea Kettle Excluding Heating Coil. ( Composite ) 14.2.17 Replacement Of Pump Impeller ( Composite ) 14.2.18 Replacement Of Impeller For 3 Hp Pump ( Composite ) 14.2.19 Replacement Of Impeller For 5 Hp Pump ( Composite ) 14.2.20 Replacement Of Cooling Fan For Motor Up To 2Hp. 14.3 Capacitors 14.3.1 Replacing The Defective Capacitor Of Table Fan / Wall Fan / Pedestal Fan / Ceiling Fan / Dip Freezer Motor / Street Light Fittings / Fluorescent Tube Fittings Or Any Other Smilar Application Etc & Testing At Site. General Guidelines For Replacement Shall Be As Per Item No 14.1 As Applicable, All As Per Instructions And As Directed By E-I-C, Es 14.3.1.1 1.5 Mfd ( Only Supply ) 14.3.1.2 1.5 Mfd ( Only Labour ) 14.3.1.3 1.5 Mfd ( Composite ) 14.3.1.4 2.5 Mfd ( Only Supply ) 14.3.1.5 2.5 Mfd ( Only Labour ) 14.3.1.6 2.5 Mfd ( Composite ) 14.3.1.7 4 Mfd ( Only Supply ) 14.3.1.8 4 Mfd ( Only Labour ) 14.3.1.9 4 Mfd ( Composite ) 14.3.1.10 5 / 6 Mfd ( Only Supply ) 14.3.1.11 5 / 6 Mfd ( Only Labour ) 14.3.1.12 5 / 6 Mfd ( Composite ) 14.3.1.13 10 / 15 Mfd ( Only Supply ) 14.3.1.14 10 / 15 Mfd ( Only Labour ) 14.3.1.15 10 / 15 Mfd ( Composite ) 14.3.1.16 20 Mfd ( Only Supply ) 14.3.1.17 20 Mfd ( Only Labour ) 14.3.1.18 20 Mfd ( Composite ) 14.3.1.19 33 Mfd ( Only Supply ) 14.3.1.20 33 Mfd ( Only Labour ) 14.3.1.21 33 Mfd ( Composite ) 14.3.1.22 40 Mfd ( Only Supply ) 14.3.1.23 40 Mfd ( Only Labour ) 14.3.1.24 40 Mfd ( Composite ) 14.3.1.25 60 Mfd ( Only Supply ) 14.3.1.26 60 Mfd ( Only Labour ) 14.3.1.27 60 Mfd ( Composite ) 14.3.1.28 80 Mfd ( Only Supply ) 14.3.1.29 80 Mfd ( Only Labour ) 14.3.1.30 80 Mfd ( Composite ) 14.3.1.31 120 Mfd ( Only Supply ) 14.3.1.32 120 Mfd ( Only Labour ) 14.3.1.33 120 Mfd ( Composite ) 14.3.1.34 200 Mfd ( Only Supply ) 14.3.1.35 200 Mfd ( Only Labour ) 14.3.1.36 200 Mfd ( Composite ) 14.4 Coils / Transformers 14.4.1 Supply & Replacement Of 240 V / 440 V No Volt Coil / Contactor Coils Of Any Make Motor Starter For Any Capacity ( L & T / Siemens Make Or Equivalent ) ( Only Supply ) 14.4.2 Supply & Replacement Of 240 V / 440 V No Volt Coil / Contactor Coils Of Any Make Motor Starter For Any Capacity ( L & T / Siemens Make Or Equivalent ) Removed / Replaced Parts Are To Be Handed Over To E-I-C, Es. ( Only Labour ) 14.4.3 Supply & Replacement Of 240 V / 440 V No Volt Coil / Contactor Coils Of Any Make Motor Starter For Any Capacity ( L & T / Siemens Make Or Equivalent ) Removed / Replaced Parts Are To Be Handed Over To E-I-C, Es ( Composite ) . 14.4.4 Supply & Replacement Of 240 V / 440 V Transformer Coils Of Any Make For Any Capacity For Emergency Light Or Any Such Other Specific Circuits / Appplications. Prior Approval Is Required. ( Only Supply ) 14.4.5 Supply & Replacement Of 240 V / 440 V Transformer Coils Of Any Make For Any Capacity For Emergency Light Or Ant Other Specific Circuits. Prior Approval Is Required. Removed / Replaced Parts Are To Be Handed Over To E-I-C, Es ( Only Labour ) . 14.4.6 Supply & Replacement Of 240 V / 440 V Transformer Coils Of Any Make For Any Capacity For Emergency Light Or Ant Other Specific Circuits. Prior Approval Is Required. Removed / Replaced Parts Are To Be Handed Over To E-I-C, Es ( Composite ) . 15.1 Olr / Starters / Terminal Boxes Supply & Replacement Of Thermal Over Load Relay For Motors Or Any Other Such Application As Decided By E-I-C, Es Including Lugging, Putting Insulation Tape Ets. In Case Of Replacement, Removed / Replaced Parts Shall Be Handed Over To E-I-C, Es Along With Gatepass / Challans Etc. 15.1.1 Up To 7.5 Hp ( Only Supply ) 15.1.2 Up To 7.5 Hp ( Only Labour ) 15.1.3 Up To 7.5 Hp ( Composite ) 15.1.4 10 Hp To 20 Hp ( Only Supply ) 15.1.5 10 Hp To 20 Hp ( Only Labour ) 15.1.6 10 Hp To 20 Hp ( Composite ) 15.1.7 25 Hp To 30 Hp ( Only Supply ) 15.1.8 25 Hp To 30 Hp ( Only Labour ) 15.1.9 25 Hp To 30 Hp ( Composite ) 15.1.10 35 Hp To 40 Hp ( Only Supply ) 15.1.11 35 Hp To 40 Hp ( Only Labour ) 15.1.12 35 Hp To 40 Hp ( Composite ) 15.1.13 45 Hp To 50 Hp ( Only Supply ) 15.1.14 45 Hp To 50 Hp ( Only Labour ) 15.1.15 45 Hp To 50 Hp ( Composite ) 15.1.16 60 Hp To 75 Hp ( Only Supply ) 15.1.17 60 Hp To 75 Hp ( Only Labour ) 15.1.18 60 Hp To 75 Hp ( Composite ) 15.2 Supply, Installation, Testing & Commissioning Of Dol Starters, Of Reputed Make Make As Per The Required Capacity Listed Below With Framework Including Connection With Lugs Etc. Complete In All Manners As Per Instruction Of Eic. In Case Of Replacement Removed Parts Shall Be Handed Pver To E-I-C, Es Along With Gatepass / Challans. 15.2.1 Up To 2 Hp / 1.5 Kw Single Phase. ( Only Supply ) 15.2.2 Up To 2 Hp / 1.5 Kw Single Phase. ( Only Labour ) 15.2.3 Up To 2 Hp / 1.5 Kw Single Phase. ( Composite ) 15.2.4 Up To 7.5 Hp / 5.5 Kw 3Phase. ( Only Supply ) 15.2.5 Up To 7.5 Hp / 5.5 Kw 3Phase. ( Only Labour ) 15.2.6 Up To 7.5 Hp / 5.5 Kw 3Phase. ( Composite ) 15.2.7 Up To 10 Hp ( Only Supply ) 15.2.8 Up To 10 Hp ( Only Labour ) 15.2.9 Up To 10 Hp ( Composite ) 15.2.10 Up To 20 Hp, ( Only Supply ) 15.2.11 Up To 20 Hp, ( Only Labour ) 15.2.12 Up To 20 Hp, ( Composite ) 15.2.13 For 30 Hp. ( Only Supply ) 15.2.14 For 30 Hp. ( Only Labour ) 15.2.15 For 30 Hp. ( Composite ) 15.2.16 For 40 Hp. ( Only Supply ) 15.2.17 For 40 Hp. ( Only Labour ) 15.2.18 For 40 Hp. ( Composite ) 15.3 Supply, Installation, Testing & Commissioning Of Fully-Automatic Star-Delta Motor Starters, As Per The Required Capacity Listed Below With Framework Including Connection With Lugs Etc. Complete In All Manners As Per Instruction Of Eic.In Case Of Replacement Removed Parts Shall Be Handed Pver To E-I-C, Es Along With Gatepass / Challans. 15.3.1 Up To 2 Hp ( Only Supply ) 15.3.2 Up To 2 Hp ( Only Labour ) 15.3.3 Up To 2 Hp ( Composite ) 15.3.4 Up To 5 Hp ( Only Supply ) 15.3.5 Up To 5 Hp ( Only Labour ) 15.3.6 Up To 5 Hp ( Composite ) 15.3.7 Up To 10 Hp ( Only Supply ) 15.3.8 Up To 10 Hp ( Only Labour ) 15.3.9 Up To 10 Hp ( Composite ) 15.3.10 Up To 12.5 Hp ( Only Supply ) 15.3.11 Up To 12.5 Hp ( Only Labour ) 15.3.12 Up To 12.5 Hp ( Composite ) 15.3.13 Up To 15 Hp ( Only Supply ) 15.3.14 Up To 15 Hp ( Only Labour ) 15.3.15 Up To 15 Hp ( Composite ) 15.3.16 Up To 20 Hp ( Only Supply ) 15.3.17 Up To 20 Hp ( Only Labour ) 15.3.18 Up To 20 Hp ( Composite ) 15.3.19 Up To 30 Hp ( Only Supply ) 15.3.20 Up To 30 Hp ( Only Labour ) 15.3.21 Up To 30 Hp ( Composite ) 15.3.22 Up To 50 Hp ( Only Supply ) 15.3.23 Up To 50 Hp ( Only Labour ) 15.3.24 Up To 50 Hp ( Composite ) 15.3.25 Up To 75 Hp ( Only Supply ) 15.3.26 Up To 75 Hp ( Only Labour ) 15.3.27 Up To 75 Hp ( Composite ) 15.3.28 Providing & Fixing Of Motor Terminal Boxes. Up To 1 Hp ( Only Supply ) 15.3.29 Up To 1 Hp ( Only Labour ) 15.3.30 Up To 1 Hp ( Composite ) 15.3.31 Up To 2 Hp ( Only Supply ) 15.3.32 Up To 2 Hp ( Only Labour ) 15.3.33 Up To 2 Hp ( Composite ) 15.3.34 Up To 5 Hp ( Only Supply ) 15.3.35 Up To 5 Hp ( Only Labour ) 15.3.36 Up To 5 Hp ( Composite ) 15.3.37 Up To 10 Hp ( Only Supply ) 15.3.38 Up To 10 Hp ( Only Labour ) 15.3.39 Up To 10 Hp ( Composite ) 15.3.40 Up To 20 Hp ( Only Supply ) 15.3.41 Up To 20 Hp ( Only Labour ) 15.3.42 Up To 20 Hp ( Composite ) 15.3.43 Up To 30 Hp ( Only Supply ) 15.3.44 Up To 30 Hp ( Only Labour ) 15.3.45 Up To 30 Hp ( Composite ) 15.3.46 Up To 50 Hp ( Only Supply ) 15.3.47 Up To 50 Hp ( Only Labour ) 15.3.48 Up To 50 Hp ( Composite ) 15.3.49 Up To 75 Hp ( Only Supply ) 15.3.50 Up To 75 Hp ( Only Labour ) 15.3.51 Up To 75 Hp ( Composite ) 16.1 Registers / Discharge Registers Register, Kiyosh Make, 10 K Ohm ± 5 Perc., 15 W, 9624, Cop- 18030. ( Only Supply ) 16.2 Register, Kiyosh Make, 10 Kohm ± 5 Perc., 15 W, 9624, Cop-15, 18030. ( Only Labour ) 16.3 Register, Kiyosh Make, 10 K Ohm ± 5 Perc., 15 W, 9624, Cop-15, 18030. ( Composite ) 16.4 Discharge Resistors For Capacitor Banks Up To 100 Kvar ( Only Supply ) 17.1 Supply, Installing Of Electrical Consumable Items With Testing & Commissioning Of Them As Specifications & As Per Direction Of Engg-In-Charge.In Case Of Replacement / Repairs, Old Materials Shall Be Handed Over To E-I-C, Es Along With Gatepass / Challans Etc. All Replacements Are Subjected To Prior Approval Of O-I-C, Es For Any Equivalent Make, If Make Is Not Mentioned. ( Kindly Refer Make List Provided Separately ) . It May Be Noted That Minimum Balance Of These Itmes Are Required To Maintain On Site For Emerrgency Use. 17.1.1 40 W Fluorescent Tube Reputed Make ( Only Supply ) 17.1.2 40 W Fluorescent Tube Reputed Make ( Only Labour ) 17.1.3 40 W Fluorescent Tube Reputed Make ( Composite ) 17.1.4 36 W Fluorescent Tube Reputed Make ( Only Supply ) 17.1.5 36 W Fluorescent Tube Reputed Make ( Only Labour ) 17.1.6 36 W Fluorescent Tube Reputed Make ( Composite ) 17.1.7 20 W Fluorescent Tube Reputed Make ( Only Supply ) 17.1.8 20 W Fluorescent Tube Reputed Make ( Only Labour ) 17.1.9 20 W Fluorescent Tube Reputed Make ( Composite ) 17.1.10 18 W Fluorescent Tube Reputed Make ( Only Supply ) 17.1.11 18 W Fluorescent Tube Reputed Make ( Only Labour ) 17.1.12 18 W Fluorescent Tube Reputed Make ( Composite ) 17.1.13 9 W Pl-S Fluorescent Tube Reputed Make ( Only Supply ) 17.1.14 9 W Pl-S Fluorescent Tube Reputed Make ( Only Labour ) 17.1.15 9 W Pl-S Fluorescent Tube Reputed Make ( Composite ) 17.1.16 11 W Pl-S Fluorescent Tube Reputed Make ( Only Supply ) 17.1.17 11 W Pl-S Fluorescent Tube Reputed Make ( Only Labour ) 17.1.18 11 W Pl-S Fluorescent Tube Reputed Make ( Composite ) 17.1.19 75 W Comptalux Lamp Of Reputed Make ( Only Supply ) 17.1.20 75 W Comptalux Lamp Of Reputed Make ( Only Labour ) 17.1.21 75 W Comptalux Lamp Of Reputed Make ( Composite ) 17.1.22 30 W Germicidal Fluorescent Ulitrea-Violet Tube Of Reputed Make ( Only Supply ) 17.1.23 30 W Germicidal Fluorescent Ulitrea-Violet Tube Of Reputed Make ( Only Labour ) 17.1.24 30 W Germicidal Fluorescent Ulitrea-Violet Tube Of Reputed Make ( Composite ) 17.1.25 36 W Germicidal Fluorescent Ulitrea-Violet Light Fixture With Tube 4 Feet ( Only Supply ) 17.1.26 36 W Germicidal Fluorescent Ulitrea-Violet Light Fixture With Tube 4 Feet ( Only Labour ) 17.1.27 36 W Germicidal Fluorescent Ulitrea-Violet Light Fixture With Tube 4 Feet ( Composite ) 17.1.28 Same As Item No 17.1.22 But 2 Or One And The Half Feet In Length ( Only Supply ) 17.1.29 Same As Item No 17.1.22 But 2 Or One And The Half Feet In Length ( Only Labour ) 17.1.30 Same As Item No 17.1.22 But 2 Or One And The Half Feet In Length ( Only Composite ) 17.1.31 Insect Killer Tube Size 2 Feet ( Only Supply ) 17.1.32 Insect Killer Tube Size 2 Feet ( Only Labour ) 17.1.33 Insect Killer Tube Size 2 Feet ( Composite ) 17.1.34 Insect Killer Tube Size One And The Half Feet ( Only Supply ) 17.1.35 Insect Killer Tube Size One And The Half Feet ( Only Labour ) 17.1.36 Insect Killer Tube Size One And The Half Feet ( Cokposite ) 17.1.37 100 W Gls Clear / Milky Lamp Reputed Make ( Only Supply ) 17.1.38 100 W Gls Clear / Milky Lamp Reputed Make ( Only Labour ) 17.1.39 100 W Gls Clear / Milky Lamp Reputed Make ( Composite ) 17.1.40 200W Clear / Milky Gls Lamp ( Only Supply ) 17.1.41 200W Clearmtilky Gls Lamp ( Only Labour ) 17.1.42 200W Clearmtilky Gls Lamp ( Composite ) 17.1.43 60 W Gls Clear / Milky Lamp Reputed Make ( Only Supply ) 17.1.44 60 W Gls Clear / Milky Lamp Reputed Make ( Only Labour ) 17.1.45 60 W Gls Clear / Milky Lamp Reputed Make ( Composite ) 17.1.46 40 W Clear / Milky Gls Lamp ( Only Supply ) 17.1.47 40 W Clear / Miilky Gls Lamp ( Only ) 17.1.48 40 W Clear / Milky Gls Lamp ( Only Supply ) 17.1.49 25 W Clear / Milky Lamp Reputed Make ( Only Supply ) 17.1.50 25 W Clear / Milky Lamp Reputed Make ( Only Labour ) 17.1.51 25 W Clear / Milky Lamp Reputed Make ( Composite ) 17.1.52 15 W Red Indication Lamp Reputed Make / Or Other Colour For Any Other Specific Application. ( Supply ) 17.1.53 15 W Red Indication Lamp Reputed Make / Or Other Colour For Any Other Specific Application. ( Labour ) 17.1.54 15 W Red Indication Lamp Reputed Make / Or Other Colour For Any Other Specific Application. ( Composite ) 17.1.55 25 W Incandescent Lamp For Exit Light ( As Per Sample ) ( Only Supply ) 17.1.56 25 W Incandescent Lamp For Exit Light ( As Per Sample ) ( Only Labour ) 17.1.57 25 W Incandescent Lamp For Exit Light ( As Per Sample ) ( Composite ) 17.1.58 8 W / 11W Pin Type Cfl Lamp ( Only Supply ) 17.1.59 8 W / 11W Pin Type Cfl Lamp ( Only Labour ) 17.1.60 8 W / 11W Pin Type Cfl Lamp ( Composite ) 17.1.61 14 W Pin Type Cfl Lamp ( Only Supply ) 17.1.62 14 W Pin Type Cfl Lamp ( Only Labour ) 17.1.63 14 W Pin Type Cfl Lamp ( Composite ) 17.1.64 23 / 25 W Cfl Tube ( Only Supply ) 17.1.65 23 / 25 W Cfl Tube ( Only Labour ) 17.1.66 23 / 25 W Cfl Tube ( Composite ) 17.1.67 14 W Plc Tube ( Only Supply ) 17.1.68 14 W Plc Tube ( Only Labour ) 17.1.69 14 W Plc Tube ( Composite ) 17.1.70 36 W Pll Tube Light ( Only Supply ) 17.1.71 36 W Pll Tube Light ( Only Labour ) 17.1.72 36 W Pll Tube Light ( Composite ) 17.1.73 Electronic Choke For 36 W Pll Fitting ( Only Supply ) 17.1.74 Electronic Choke For 36 W Pll Fitting ( Only Labour ) 17.1.75 Electronic Choke For 36 W Pll Fitting ( Composite ) 17.1.76 40 W Choke / Ballast Reputed Make ( Only Supply ) 17.1.77 40 W Choke / Ballast Reputed Make ( Only Labour ) 17.1.78 40 W Choke / Ballast Reputed Make ( Composite ) 17.1.79 Electronic Choke ( 40 W ) ( Only Supply ) 17.1.80 Electronic Choke ( 40 W ) ( Only Labour ) 17.1.81 Electronic Choke ( 40 W ) ( Composite ) 17.1.82 20 W Choke / Ballast Reputed Make ( Only Supply ) 17.1.83 20 W Choke / Ballast Reputed Make ( Only Labour ) 17.1.84 20 W Choke / Ballast Reputed Make ( Only Composite ) 17.1.85 9 W Choke / Ballast Reputed Make ( Only Supply ) 17.1.86 9 W Choke / Ballast Reputed Make ( Only Labour ) 17.1.87 9 W Choke / Ballast Reputed Make ( Composite ) 17.1.88 11 W Choke / Ballast Reputed Make ( Only Supply ) 17.1.89 11 W Choke / Ballast Reputed Make ( Only Labour ) 17.1.90 11 W Choke / Ballast Reputed Make ( Composite ) 17.1.91 30 W Choke / Ballast For Germicidal Fixture Gajjars Make ( Only Supply ) 17.1.92 30 W Choke / Ballast For Germicidal Fixture Gajjars Make ( Only Labour ) 17.1.93 30 W Choke / Ballast For Germicidal Fixture Gajjars Make ( Composite ) 17.1.94 Fixing / Replacing Of Side Holders ( 1 No. ) ( Only Supply ) 17.1.95 Fixing / Replacing Of Side Holders ( 1 No. ) ( Only Labour ) 17.1.96 Fixing / Replacing Of Side Holders ( 1 No. ) ( Composite ) 17.1.97 Starter For Fluorescent 36W Tube Light ( Only Supply ) 17.1.98 Starter For Fluorescent 36W Tube Light ( Only Labour ) 17.1.99 Starter For Fluorescent 36W Tube Light ( Composite ) 17.1.100 Replacing Of Starter Holder For Tube Light ( Only Supply ) 17.1.101 Replacing Of Starter Holder For Tube Light ( Only Labour ) 17.1.102 Replacing Of Starter Holder For Tube Light ( Composite ) 17.1.103 Replacing Of Side Holder For Pl Lamp Fitting ( Only Supply ) 17.1.104 Replacing Of Side Holder For Pl Lamp Fitting ( Only Labour ) 17.1.105 Replacing Of Side Holder For Pl Lamp Fitting ( Composite ) 17.1.106 Replacing Of Halogen Tube Reputed Make 500 W ( Only Supply ) 17.1.107 Replacing Of Halogen Tube Reputed Make 500 W ( Only Labour ) 17.1.108 Replacing Of Halogen Tube Reputed Make 500 W ( Composite ) 17.1.109 Replacing Of Halogen Tube Reputed Make 1000 W ( Only Supply ) 17.1.110 Replacing Of Halogen Tube Reputed Make 1000 W ( Only Labour ) 17.1.111 Replacing Of Halogen Tube Reputed Make 1000 W ( Composite ) 17.1.112 15 W ( Pigmy Lamp ) ( Only Supply ) 17.1.113 15 W ( Pigmy Lamp ) ( Only Labour ) 17.1.114 15 W ( Pigmy Lamp ) ( Composite ) 17.1.115 Floor Washer / Wall Washer Light Of 230Volt , 20W , Led 2400K , Low Light Aluminium Body , Flush In Wall Ground Type ( Only Supply ) 17.1.116 Floor Washer / Wall Washer Light Of 230Volt , 20W , Led 2400K , Low Light Aluminium Body , Flush In Wall Ground Type ( Only Labour ) 17.1.117 Floor Washer / Wall Washer Light Of 230Volt , 20W , Led 2400K , Low Light Aluminium Body , Flush In Wall Ground Type ( Composite ) 17.1.118 Philips Or Equivalent 12 V, 50 W, Halogen Lamp For Down Lighter / Spot Light Fittings ( Only Supply ) 17.1.119 Philips Or Equivalent 12 V, 50 W, Halogen Lamp For Down Lighter / Spot Light Fittings ( Only Labour ) 17.1.120 Philips Or Equivalent 12 V, 50 W, Halogen Lamp For Down Lighter / Spot Light Fittings ( Composite ) 17.1.121 18 W Reputed Make Choke Suitable For 18 W Plc Tubes ( Only Supply ) 17.1.122 18 W Reputed Make Choke Suitable For 18 W Plc Tubes ( Only Labour ) 17.1.123 18 W Reputed Make Choke Suitable For 18 W Plc Tubes ( Composite ) 17.1.124 Decorative General Type Table / Wall / Reading Lamp ( Plc / Cfl / Incandescent Lamp Compatible Etc ) ( Only Supply ) 17.1.125 Decorative Type Table / Wall Lamp ( Plc / Cfl / Incandescent Lamp Compatible Etc ) But For Customized Application. As Directed By O-I-C, Es ( Only Supply ) 17.1.126 Decorative Type Table / Wall Lamp ( Plc / Cfl / Incandescent Lamp Compatible Etc ) But For Customized Application. As Directed By O-I-C, Es ( Only Labour ) 17.1.127 Decorative Type Table / Wall Lamp ( Plc / Cfl / Incandescent Lamp Compatible Etc ) But For Customized Application. As Directed By O-I-C, Es ( Composite ) 17.1.128 Fixing / Replacement Of 25W / 20W Plc Tube For Existing Makes Lighting Fixture ( Only Supply ) 17.1.129 Fixing / Replacement Of 25W / 20W Plc Tube For Existing Makes Lighting Fixture ( Only Labour ) 17.1.130 Fixing / Replacement Of 25W / 20W Plc Tube For Existing Makes Lighting Fixture ( Composite ) 17.1.131 Fixing / Replacement Of 8W T5, 1 Feet Long Fluorescent Tube Light ( Only Supply ) 17.1.132 Fixing / Replacement Of 8W T5, 1 Feet Long Fluorescent Tube Light ( Only Labour ) 17.1.133 Fixing / Replacement Of 8W T5, 1 Feet Long Fluorescent Tube Light ( Composite ) 17.1.134 Fixing / Replacement Of 18 / 20W Electronic Choke ( Only Supply ) 17.1.135 Fixing / Replacement Of 18 / 20W Electronic Choke ( Only Labour ) 17.1.136 Fixing / Replacement Of 18 / 20W Electronic Choke ( Composite ) 17.1.137 Fixing / Replacement Of 28W T-5 Energy Efficient Fluorescent Tube ( Only Supply ) 17.1.138 Fixing / Replacement Of 28W T-5 Energy Efficient Fluorescent Tube ( Only Labour ) 17.1.139 Fixing / Replacement Of 28W T-5 Energy Efficient Fluorescent Tube ( Composite ) 17.1.140 Fixing / Replacement Of 30W Fluroscent Tube ( Only Supply ) 17.1.141 Fixing / Replacement Of 30W Fluroscent Tube ( Only Labour ) 17.1.142 Fixing / Replacement Of 30W Fluroscent Tube ( Composite ) 17.1.143 Fixing / Replacement Of 9 / 11W Electronic Choke ( Only Supply ) 17.1.144 Fixing / Replacement Of 9 / 11W Electronic Choke ( Only Labour ) 17.1.145 Fixing / Replacement Of 9 / 11W Electronic Choke ( Composite ) 17.1.146 Fixing / Replacement Of 100W Comptlux Lamp ( Only Supply ) 17.1.147 Fixing / Replacement Of 100W Comptlux Lamp ( Only Labour ) 17.1.148 Fixing / Replacement Of 100W Comptlux Lamp ( Composite ) 17.1.149 30W Tube Light 3Feet ( Only Supply ) 17.1.150 30W Tube Light 3Feet ( Only Labour ) 17.1.151 30W Tube Light 3Feet ( Composite ) 17.2 Led Lamps Pin Type / Thread Type 17.2.1 Fixing / Replacement Of 2 / 3W Led Lamp ( Only Supply ) 17.2.2 Fixing / Replacement Of 2 / 3W Led Lamp ( Only Labour ) 17.2.3 Fixing / Replacement Of 2 / 3W Led Lamp ( Composite ) 17.2.4 Fixing / Replacement Of 5 / 7 / 9W Led Lamp ( Only Supply ) 17.2.5 Fixing / Replacement Of 5 / 7 / 9W Led Lamp ( Only Labour ) 17.2.6 Fixing / Replacement Of 5 / 7 / 9W Led Lamp ( Composite ) 17.2.7 Fixing / Replacement Of 12W Led Lamp ( Only Supply ) 17.2.8 Fixing / Replacement Of 12W Led Lamp ( Only Labour ) 17.2.9 Fixing / Replacement Of 12W Led Lamp ( Composite ) 17.2.10 Fixing / Replacement Of 15W Led Lamp ( Only Supply ) 17.2.11 Fixing / Replacement Of 15W Led Lamp ( Only Labour ) 17.2.12 Fixing / Replacement Of 15W Led Lamp ( Composite ) 17.2.13 Fixing / Replacement Of 18W Led Lamp ( Only Supply ) 17.2.14 Fixing / Replacement Of 18W Led Lamp ( Only Labour ) 17.2.15 Fixing / Replacement Of 18W Led Lamp ( Composite ) 17.2.16 Fixing / Replacement Of 8W 2 Long Led Tube ( Only Supply ) 17.2.17 Fixing / Replacement Of 8W 2 Long Led Tube ( Only Labour ) 17.2.18 Fixing / Replacement Of 8W 2 Long Led Tube ( Composite ) 17.2.19 Fixing / Replacement Of 18W Led Pll Lamp ( Only Supply ) 17.2.20 Fixing / Replacement Of 18W Led Pll Lamp ( Only Labour ) 17.2.21 Fixing / Replacement Of 18W Led Pll Lamp ( Composite ) 17.2.22 Fixing / Replacement Of 30W Led Lamp ( Only Supply ) 17.2.23 Fixing / Replacement Of 30W Led Lamp ( Only Labour ) 17.2.24 Fixing / Replacement Of 30W Led Lamp ( Composite ) 17.2.25 Fixing / Replacement Of 35W Led Lamp ( Only Supply ) 17.2.26 Fixing / Replacement Of 35W Led Lamp ( Only Labour ) 17.2.27 Fixing / Replacement Of 35W Led Lamp ( Composite ) 17.3 Led Driver 17.3.1 Fixing / Replacement Of 3 / 5W Led Driver ( Only Supply ) 17.3.2 Ffixing / Replacement 3 / 5W Led Driver ( Only Labour ) 17.3.3 Fixing / Replacement Of 3 / 5W Led Driver ( Composite ) 17.3.4 Fixing / Replacement Of 9W Led Driver ( Only Supply ) 17.3.5 Ffixing / Replacement 9W Led Driver ( Only Labour ) 17.3.6 Fixing / Replacement Of 9W Led Driver ( Composite ) 17.3.7 Fixing / Replacement Of 12 / 15W Led Driver ( Only Supply ) 17.3.8 Ffixing / Replacement 12 / 15W Led Driver ( Only Labour ) 17.3.9 Fixing / Replacement Of 12 / 15W Led Driver ( Composite ) 17.3.10 Fixing / Replacement Of 18W Led Driver ( Only Supply ) 17.3.11 Ffixing / Replacement 18W Led Driver ( Only Labour ) 17.3.12 Fixing / Replacement Of 18W Led Driver ( Composite ) 17.3.13 Fixing / Replacement Of 24W Led Driver ( Only Supply ) 17.3.14 Ffixing / Replacement 24W Led Driver ( Only Labour ) 17.3.15 Fixing / Replacement Of 24W Led Driver ( Composite ) 17.3.16 Fixing / Replacement Of 30W Led Driver ( Only Supply ) 17.3.17 Ffixing / Replacement 30W Led Driver ( Only Labour ) 17.3.18 Fixing / Replacement Of 30W Led Driver ( Composite ) 17.3.19 Fixing / Replacement Of 36W Led Driver ( Only Supply ) 17.3.20 Ffixing / Replacement 36W Led Driver ( Only Labour ) 17.3.21 Fixing / Replacement Of 36W Led Driver ( Composite ) 18.1 Gyesers / Heaters Supply, Installation, Testing & Commissining Of Various Types Of Water Gyesers, Heaters, Heating Coils, Hot Plates, Strip Heaters Or Any Similar Application Heating Equipment As Per The Required Specifications As Per Instructions & As Directed By E-I-C, Es. In Case Of Replacement / Repairs, Old Items Are To Be Handed Over To E-I-C, Es Along With Gatepass / Challans Etc. 18.1.1 25 Litre Capacity , Hospital Use Water Heater ( Only Supply ) 18.1.2 25 Litre Capacity , Hospital Use Water Heater ( Only Labour ) 18.1.3 25 Litre Capacity , Hospital Use Water Heater ( Composite ) 18.1.4 Reputed Make 6 Litre Capacity , Hospital Use Water Heater ( Only Supply ) 18.1.5 Reputed Make 6 Litre Capacity , Hospital Use Water Heater ( Only Labour ) 18.1.6 Reputed Make 6 Litre Capacity , Hospital Use Water Heater ( Composite ) 18.1.7 Reputed Make 1 Litre Capacity Water Geyser ( Only Supply ) 18.1.8 Reputed Make 1 Litre Capacity Water Geyser ( Only Labour ) 18.1.9 Reputed Make 1 Litre Capacity Water Geyser ( Composite ) 18.1.10 Reputed Make 2 Litre Capacity Water Geyser ( Only Supply ) 18.1.11 Reputed Make 2 Litre Capacity Water Geyser ( Only Labour ) 18.1.12 Reputed Make 2 Litre Capacity Water Geyser ( Composite ) 18.1.13 Reputed Make 3 Litre Capacity Water Geyser ( Only Supply ) 18.1.14 Reputed Make 3 Litre Capacity Water Geyser ( Only Labour ) 18.1.15 Reputed Make 3 Litre Capacity Water Geyser ( Composite ) 18.2 Thermostats And Heating Coils. 18.2.1 Thermostat Of Good Quality For All Types Of Gysers ( Only Supply ) 18.2.2 Thermostat Of Good Quality For All Types Of Gysers ( Only Labour ) 18.2.3 Thermostat Of Good Quality For All Types Of Gysers ( Composite ) 18.2.4 Thermostats0 -300 Oc For Oven ( Only Supply ) 18.2.5 Thermostats0 -300 Oc For Oven ( Only Labour ) 18.2.6 Thermostats0 -300 Oc For Oven ( Composite ) 18.2.7 Supply / Replacement Of Coil For Hot Plate ( Only Supply ) 18.2.8 Supply / Replacement Of Coil For Hot Plate ( Only Supply ) 18.2.9 Supply / Replacement Of Coil For Hot Plate ( Only Supply ) 18.2.10 Supply / Replacement Of Coil For Iron ( Only Supply ) 18.2.11 Supply / Replacement Of Coil For Iron ( Only Labour ) 18.2.12 Supply / Replacement Of Coil For Iron ( Composite ) 18.2.13 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers1000 W ( Only Supply ) 18.2.14 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers1000 W ( Only Labour ) 18.2.15 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers1000 W ( Composite ) 18.2.16 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers1500 W ( Only Supply ) 18.2.17 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers1500 W ( Only Labour ) 18.2.18 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers1500 W ( Composite ) 18.2.19 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers2000 W ( Only Supply ) 18.2.20 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers2000 W ( Only Labour ) 18.2.21 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers2000 W ( Composite ) 18.2.22 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers3000 W ( General ) ( Only Supply ) 18.2.23 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers3000 W ( General ) ( Only Labour ) 18.2.24 Fixing / Replacement Of Coil / Tube Type Heaters For Geysers3000 W ( General ) ( Composite ) 18.2.25 3000 W ( Idli / Chapati Maker Etc ) ( Only Supply ) 18.2.26 3000 W ( Idli / Chapati Maker Etc ) ( Only Labour ) 18.2.27 3000 W ( Idli / Chapati Maker Etc ) ( Composite ) 18.2.28 500 W Coil Heater ( Only Supply ) 18.2.29 500 W Coil Heater ( Only Labour ) 18.2.30 500 W Coil Heater ( Composite ) 18.2.31 Replacement Of Kettle Heaters ( Only Supply ) 18.2.32 Replacement Of Kettle Heaters ( Only Labour ) 18.2.33 Replacement Of Kettle Heaters ( Composite ) 18.2.34 Replacement Of Over Load Relay For Gysers / Hot Plates And Other Similar Equipments. ( Only Supply ) 18.2.35 Replacement Of Over Load Relay For Gysers / Hot Plates And Other Similar Equipments. ( Only Labour ) 18.2.36 Replacement Of Over Load Relay For Gysers / Hot Plates And Other Similar Equipments. ( Composite ) 18.2.37 Replacement Of Sealer Coil ( Only Supply ) 18.2.38 Replacement Of Sealer Coil ( Only Labour ) 18.2.39 Replacement Of Sealer Coil ( Composite ) 18.3 Strip Heaters. 18.3.1 Finned Type Strip Heater For Ahu, 5 Kw ( For Approx Size -1.5 Mtrs / As Per Sample ) ( Only Supply ) 18.3.2 Finned Type Strip Heater For Ahu, 5 Kw ( For Approx Size -1.5 Mtrs / As Per Sample ) ( Only Labour ) 18.3.3 Finned Type Strip Heater For Ahu, 5 Kw ( For Approx Size -1.5 Mtrs / As Per Sample ) ( Composite ) 18.3.4 Finned Type Strip Heater For Ahu, 5 Kw ( For Approx Size -0.75 Mtrs / As Per Sample ) ( Only Supply ) 18.3.5 Finned Type Strip Heater For Ahu, 5 Kw ( For Approx Size -0.75 Mtrs / As Per Sample ) ( Only Labour ) 18.3.6 Finned Type Strip Heater For Ahu, 5 Kw ( For Approx Size -0.75 Mtrs / As Per Sample ) ( Composite ) 18.3.7 Finned Type Strip Heater For Ahu, 6 Kw ( As Per Sample ) Or As Directed By O-I-C, Es ( Only Supply ) 18.3.8 Finned Type Strip Heater For Ahu, 6 Kw ( As Per Sample ) Or As Directed By O-I-C, Es ( Only Labour ) 18.3.9 Finned Type Strip Heater For Ahu, 6 Kw ( As Per Sample ) Or As Directed By O-I-C, Es ( Composite ) 18.3.10 Finned Type Strip Heater For Ahu, 3 Kw ( As Per Sample ) Or As Directed By O-I-C, Es ( Only Supply ) 18.3.11 Finned Type Strip Heater For Ahu, 3 Kw ( As Per Sample ) Or As Directed By O-I-C, Es ( Only Labour ) 18.3.12 Finned Type Strip Heater For Ahu, 3 Kw ( As Per Sample ) Or As Directed By O-I-C, Es ( Composite ) 18.3.13 Finned Type Strip Heater For Ahu, 2 Kw ( As Per Sample ) Or As Directed By O-I-C, Es ( Only Supply ) 18.3.14 Finned Type Strip Heater For Ahu, 2 Kw ( As Per Sample ) Or As Directed By O-I-C, Es ( Only Labour ) 18.3.15 Finned Type Strip Heater For Ahu, 2 Kw ( As Per Sample ) Or As Directed By O-I-C, Es ( Composite ) 19.1.A Mv Cable Work Supply. Installation, Testing & Commissioning Of 1.1 Kv Grade Pvc Insulated Stranded / Round / Flat Wire Armoured Copper / Al Conductor Power Cables Isi Mark Reputed Make Fixed On Wall / Column / Ceiling Or In Shaft / Existing Trench On 6 Mm Thick Spacers / Angle Support Fixed With Screws / Coach Screws / Anchor Fasteners, All Other Fixing Accessories Etc. As Per Instruction Of Engg.-In-Charge. 19.1.1 2 X 4 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.1.2 2 X 4 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.1.3 2 X 4 Sq. Mm Copper Conductor Cable ( Composite ) 19.1.4 2 X 6 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.1.5 2 X 6 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.1.6 2 X 6 Sq. Mm Copper Conductor Cable ( Composite ) 19.1.7 3 X 1.5 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.1.8 3 X 1.5 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.1.9 3 X 1.5 Sq. Mm Copper Conductor Cable ( Composite ) 19.1.10 3 X 2.5 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.1.11 3 X 2.5 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.1.12 3 X 2.5 Sq. Mm Copper Conductor Cable ( Composite ) 19.1.13 3 X 4 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.1.14 3 X 4 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.1.15 3 X 4 Sq. Mm Copper Conductor Cable ( Composite ) 19.1.16 3 X 6 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.1.17 3 X 6 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.1.18 3 X 6 Sq. Mm Copper Conductor Cable ( Composite ) 19.1.19 3 X 10 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.1.20 3 X 10 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.1.21 3 X 10 Sq. Mm Copper Conductor Cable ( Composite ) 19.2 Supply, Laying, Testing & Commissioning Of 1.1 Kv Ac Grade Pvc Insulated Isi Mark Armored, Bright Annealed Copper / Aluminium Conductor Cable Below Earth 900 Mm. Cable In The Ground Shall Be Covered On Top & Sides With Baked Bricks Conforming To Is 107 Including Dewatering, Sand Bedding, Back Filling & Re-Instatement, Consolidation & Removal Of Excess Earth With In A Radius Of 500 Mtr. As Per Instruction Of E-I-C. 19.2.1 2 X 4 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.2.2 2 X 4 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.2.3 2 X 4 Sq. Mm Copper Conductor Cable ( Composite ) 19.2.4 2 X 6 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.2.5 2 X 6 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.2.6 2 X 6 Sq. Mm Copper Conductor Cable ( Composite ) 19.2.7 3 X 1.5 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.2.8 3 X 1.5 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.2.9 3 X 1.5 Sq. Mm Copper Conductor Cable ( Composite ) 19.2.10 3 X 2.5 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.2.11 3 X 2.5 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.2.12 3 X 2.5 Sq. Mm Copper Conductor Cable ( Composite ) 19.2.13 3 X 4 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.2.14 3 X 4 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.2.15 3 X 4 Sq. Mm Copper Conductor Cable ( Composite ) 19.2.16 3 X 6 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.2.17 3 X 6 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.2.18 3 X 6 Sq. Mm Copper Conductor Cable ( Composite ) 19.2.19 3 X 10 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.2.20 3 X 10 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.2.21 3 X 10 Sq. Mm Copper Conductor Cable ( Composite ) 19.3 Supply, Laying, Testing & Commissioning Of 1.1 Kv Ac Grade Pvc Insulated Isi Mark Armored, Bright Annealed Copper / Aluminium Conductor Cable In Ground At 900 Mm Through Suitable Size Of Dwc Hdpe Pipes, Along With Cable Pulling Chamber With Heavy Duty Openable Cover At The Both End & If Required In Between As Directed By In-Charge, Back Filling & Re-Instatement, Consolidation & Removal Of Excess Earth With In A Radius Of 500 Mtr. As Per Instruction Of E-I-C. 19.3.1 2 X 4 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.3.2 2 X 4 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.3.3 2 X 4 Sq. Mm Copper Conductor Cable ( Composite ) 19.3.4 2 X 6 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.3.5 2 X 6 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.3.6 2 X 6 Sq. Mm Copper Conductor Cable ( Composite ) 19.3.7 3 X 1.5 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.3.8 3 X 1.5 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.3.9 3 X 1.5 Sq. Mm Copper Conductor Cable ( Composite ) 19.3.10 3 X 2.5 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.3.11 3 X 2.5 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.3.12 3 X 2.5 Sq. Mm Copper Conductor Cable ( Composite ) 19.3.13 3 X 4 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.3.14 3 X 4 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.3.15 3 X 4 Sq. Mm Copper Conductor Cable ( Composite ) 19.3.16 3 X 6 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.3.17 3 X 6 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.3.18 3 X 6 Sq. Mm Copper Conductor Cable ( Composite ) 19.3.19 3 X 10 Sq. Mm Copper Conductor Cable ( Only Supply ) 19.3.20 3 X 10 Sq. Mm Copper Conductor Cable ( Only Labour ) 19.3.21 3 X 10 Sq. Mm Copper Conductor Cable ( Composite ) 19.4 Supply, Installation, Testing & Commissioning Of 1.1 Kv Grade Pvc Insulated Stranded / Round Wire Armoured Copper / Aluminium Conductor Power Cables Isi Mark Fixed On Wall / Coloum / Ceiling Or In Shaft / Existing Trench On 5 Mm Thick Spacers / Angle Support Fixed With Screws / Coach Screws / Anchor Fasteners, All Other Fixing Accessories Etc. As Per Instruction Of Engg.-In-Charge. 19.4.1 4 X 1.5 Sq. Mm. Copper Conductor ( Only Supply ) 19.4.2. 4 X 1.5 Sq. Mm. Copper Conductor ( Only Labour ) 19.4.3 4 X 1.5 Sq. Mm. Copper Conductor ( Composite ) 19.4.4 4 X 2.5 Sq. Mm .Copper Cable ( Only Supply ) 19.4.5 4 X 2.5 Sq. Mm .Copper Cable ( Only Labour ) 19.4.6 4 X 2.5 Sq. Mm .Copper Cable ( Composite ) 19.4.7 4 X 4 Sq. Mm Copper Conductor ( Only Supply ) 19.4.8 4 X 4 Sq. Mm Copper Conductor ( Only Labour ) 19.4.9 4 X 4 Sq. Mm Copper Conductor ( Composite ) 19.4.10 4 X 6 Sq. Mm Copper Conductor ( Only Supply ) 19.4.11 4 X 6 Sq. Mm Copper Conductor ( Only Labour ) 19.4.12 4 X 6 Sq. Mm Copper Conductor ( Composite ) 19.4.13 4 X 10 Sq. Mm Copper Conductor ( Only Supply ) 19.4.14 4 X 10 Sq. Mm Copper Conductor ( Only Labour ) 19.4.15 4 X 10 Sq. Mm Copper Conductor ( Composite ) 19.4.16 4 X 16 Sq. Mm Copper Conductor ( Only Supply ) 19.4.17 4 X 16 Sq. Mm Copper Conductor ( Only Labour ) 19.4.18 4 X 16 Sq. Mm Copper Conductor ( Composite ) 19.4.19 4 X 25 Sq. Mm Copper Conductor ( Only Supply ) 19.4.20 4 X 25 Sq. Mm Copper Conductor ( Only Labour ) 19.4.21 4 X 25 Sq. Mm Copper Conductor ( Composite ) 19.4.22 3.5 X 25 Sq.Mm Copper Conductor ( Only Supply ) 19.4.23 3.5 X 25 Sq.Mm Copper Conductor ( Only Labour ) 19.4.24 3.5 X 25 Sq.Mm Copper Conductor ( Composite ) 19.4.25 4 X 10 Sq. Mm Al Conductor ( Only Supply ) 19.4.26 4 X 10 Sq. Mm Al Conductor ( Only Labour ) 19.4.27 4 X 10 Sq. Mm Al Conductor ( Composite ) 19.4.28 4 X 16 Sq. Mm Al Conductor ( Only Supply ) 19.4.29 4 X 16 Sq. Mm Al Conductor ( Only Labour ) 19.4.30 4 X 16 Sq. Mm Al Conductor ( Composite ) 19.4.31 4 X 25 Sq. Mm Al Conductor ( Only Supply ) 19.4.32 4 X 25 Sq. Mm Al Conductor ( Only Labour ) 19.4.33 4 X 25 Sq. Mm Al Conductor ( Composite ) 19.4.34 3.5 X 25 Sq. Mm Al Conducto ( Only Supply ) 19.4.35 3.5 X 25 Sq. Mm Al Conducto ( Only Labour ) 19.4.36 3.5 X 25 Sq. Mm Al Conducto ( Composite ) 19.4.37 3.5 X 35 Sq. Mm Al Conductor ( Only Supply ) 19.4.38 3.5 X 35 Sq. Mm Al Conductor ( Only Labour ) 19.4.39 3.5 X 35 Sq. Mm Al Conductor ( Composite ) 19.4.40 3.5 X 50 Sq. Mm Al Conducto ( Only Supply ) 19.4.41 3.5 X 50 Sq. Mm Al Conducto ( Only Labour ) 19.4.42 3.5 X 50 Sq. Mm Al Conducto ( Composite ) 19.4.43 3.5 X 70 Sq. Mm Al Conductor ( Only Supply ) 19.4.44 3.5 X 70 Sq. Mm Al Conductor ( Only Lanbour ) 19.4.45 3.5 X 70 Sq. Mm Al Conductor ( Composite ) 19.4.46 3.5 X 95 Sq. Mm Al Conductor ( Only Supply ) 19.4.47 3.5 X 95 Sq. Mm Al Conductor ( Only Labour ) 19.4.48 3.5 X 95 Sq. Mm Al Conductor ( Composite ) 19.5 Supply, Laying, Testing & Commissioning Of 1.1 Kv Ac Grade Pvc Insulated Isi Mark Armored, Bright Annealed Copper / Aluminium Conductor Cable Below Earth 900 Mm. Cable In The Ground Shall Be Covered On Top & Sides With Baked Bricks Conforming To Is 107 Including Dewatering, Sand Bedding, Back Filling & Re-Instatement, Consolidation & Removal Of Excess Earth With In A Radius Of 500 Mtr. As Per Instruction Of E-I-C. 19.5.1 4 X 1.5 Sq. Mm. Copper Conductor ( Only Supply ) 19.5.2 4 X 1.5 Sq. Mm. Copper Conductor ( Only Labour ) 19.5.3 4 X 1.5 Sq. Mm. Copper Conductor ( Composite ) 19.5.4 4 X 2.5 Sq. Mm .Copper Cable ( Only Supply ) 19.5.5 4 X 2.5 Sq. Mm .Copper Cable ( Only Labour ) 19.5.6 4 X 2.5 Sq. Mm .Copper Cable ( Composite ) 19.5.7 4 X 4 Sq. Mm Copper Conductor ( Only Supply ) 19.5.8 4 X 4 Sq. Mm Copper Conductor ( Only Labour ) 19.5.9 4 X 4 Sq. Mm Copper Conductor ( Composite ) 19.5.10 4 X 6 Sq. Mm Copper Conductor ( Only Supply ) 19.5.11 4 X 6 Sq. Mm Copper Conductor ( Only Labour ) 19.5.12 4 X 6 Sq. Mm Copper Conductor ( Composite ) 19.5.13 4 X 10 Sq. Mm Copper Conductor ( Only Supply ) 19.5.14 4 X 10 Sq. Mm Copper Conductor ( Only Labour ) 19.5.15 4 X 10 Sq. Mm Copper Conductor ( Composite ) 19.5.16 4 X 16 Sq. Mm Copper Conductor ( Only Supply ) 19.5.17 4 X 16 Sq. Mm Copper Conductor ( Only Labour ) 19.5.18 4 X 16 Sq. Mm Copper Conductor ( Composite ) 19.5.19 4 X 25 Sq. Mm Copper Conductor ( Only Supply ) 19.5.20 4 X 25 Sq. Mm Copper Conductor ( Only Labour ) 19.5.21 4 X 25 Sq. Mm Copper Conductor ( Composite ) 19.5.22 3.5 X 25 Sq.Mm Copper Conductor ( Only Supply ) 19.5.23 3.5 X 25 Sq.Mm Copper Conductor ( Only Labour ) 19.5.24 3.5 X 25 Sq.Mm Copper Conductor ( Composite ) 19.5.25 4 X 10 Sq. Mm Al Conductor ( Only Supply ) 19.5.26 4 X 10 Sq. Mm Al Conductor ( Only Labour ) 19.5.27 4 X 10 Sq. Mm Al Conductor ( Composite ) 19.5.28 4 X 16 Sq. Mm Al Conductor ( Only Supply ) 19.5.29 4 X 16 Sq. Mm Al Conductor ( Only Labour ) 19.5.30 4 X 16 Sq. Mm Al Conductor ( Composite ) 19.5.31 4 X 25 Sq. Mm Al Conductor ( Only Supply ) 19.5.32 4 X 25 Sq. Mm Al Conductor ( Only Labour ) 19.5.33 4 X 25 Sq. Mm Al Conductor ( Composite ) 19.5.34 3.5 X 25 Sq. Mm Al Conducto ( Only Supply ) 19.5.35 3.5 X 25 Sq. Mm Al Conducto ( Only Labour ) 19.5.36 3.5 X 25 Sq. Mm Al Conducto ( Composite ) 19.5.37 3.5 X 35 Sq. Mm Al Conductor ( Only Supply ) 19.5.38 3.5 X 35 Sq. Mm Al Conductor ( Only Labour ) 19.5.39 3.5 X 35 Sq. Mm Al Conductor ( Composite ) 19.5.40 3.5 X 50 Sq. Mm Al Conducto ( Only Supply ) 19.5.41 3.5 X 50 Sq. Mm Al Conducto ( Only Labour ) 19.5.42 3.5 X 50 Sq. Mm Al Conducto ( Composite ) 19.5.43 3.5 X 70 Sq. Mm Al Conductor ( Only Supply ) 19.5.44 3.5 X 70 Sq. Mm Al Conductor ( Only Lanbour ) 19.5.45 3.5 X 70 Sq. Mm Al Conductor ( Composite ) 19.5.46 3.5 X 95 Sq. Mm Al Conductor ( Only Supply ) 19.5.47 3.5 X 95 Sq. Mm Al Conductor ( Only Labour ) 19.5.48 3.5 X 95 Sq. Mm Al Conductor ( Composite ) 19.6 Supply, Laying, Testing & Commissioning Of 1.1 Kv Ac Grade Pvc Insulated Isi Mark Armored, Bright Annealed Copper / Aluminium Conductor Cable In Ground At 900 Mm Through Suitable Size Of Dwc Hdpe Pipes, Along With Cable Pulling Chamber With Heavy Duty Openable Cover At The Both End & If Required In Between As Directed By In-Charge, Back Filling & Re-Instatement, Consolidation & Removal Of Excess Earth With In A Radius Of 500 Mtr. As Per Instruction Of E-I-C. 19.6.1 4 X 1.5 Sq. Mm. Copper Conductor ( Only Supply ) 19.6.2 4 X 1.5 Sq. Mm. Copper Conductor ( Only Labour ) 19.6.3 4 X 1.5 Sq. Mm. Copper Conductor ( Composite ) 19.6.4 4 X 2.5 Sq. Mm .Copper Cable ( Only Supply ) 19.6.5 4 X 2.5 Sq. Mm .Copper Cable ( Only Labour ) 19.6.6 4 X 2.5 Sq. Mm .Copper Cable ( Composite ) 19.6.7 4 X 4 Sq. Mm Copper Conductor ( Only Supply ) 19.6.8 4 X 4 Sq. Mm Copper Conductor ( Only Labour ) 19.6.9 4 X 4 Sq. Mm Copper Conductor ( Composite ) 19.6.10 4 X 6 Sq. Mm Copper Conductor ( Only Supply ) 19.6.11 4 X 6 Sq. Mm Copper Conductor ( Only Labour ) 19.6.12 4 X 6 Sq. Mm Copper Conductor ( Composite ) 19.6.13 4 X 10 Sq. Mm Copper Conductor ( Only Supply ) 19.6.14 4 X 10 Sq. Mm Copper Conductor ( Only Labour ) 19.6.15 4 X 10 Sq. Mm Copper Conductor ( Composite ) 19.6.16 4 X 16 Sq. Mm Copper Conductor ( Only Supply ) 19.6.17 4 X 16 Sq. Mm Copper Conductor ( Only Labour ) 19.6.18 4 X 16 Sq. Mm Copper Conductor ( Composite ) 19.6.19 4 X 25 Sq. Mm Copper Conductor ( Only Supply ) 19.6.20 4 X 25 Sq. Mm Copper Conductor ( Only Labour ) 19.6.21 4 X 25 Sq. Mm Copper Conductor ( Composite ) 19.6.22 3.5 X 25 Sq.Mm Copper Conductor ( Only Supply ) 19.6.23 3.5 X 25 Sq.Mm Copper Conductor ( Only Labour ) 19.6.24 3.5 X 25 Sq.Mm Copper Conductor ( Composite ) 19.6.25 4 X 10 Sq. Mm Al Conductor ( Only Supply ) 19.6.26 4 X 10 Sq. Mm Al Conductor ( Only Labour ) 19.6.27 4 X 10 Sq. Mm Al Conductor ( Composite ) 19.6.28 4 X 16 Sq. Mm Al Conductor ( Only Supply ) 19.6.29 4 X 16 Sq. Mm Al Conductor ( Only Labour ) 19.6.30 4 X 16 Sq. Mm Al Conductor ( Composite ) 19.6.31 4 X 25 Sq. Mm Al Conductor ( Only Supply ) 19.6.32 4 X 25 Sq. Mm Al Conductor ( Only Labour ) 19.6.33 4 X 25 Sq. Mm Al Conductor ( Composite ) 19.6.34 3.5 X 25 Sq. Mm Al Conducto ( Only Supply ) 19.6.35 3.5 X 25 Sq. Mm Al Conducto ( Only Labour ) 19.6.36 3.5 X 25 Sq. Mm Al Conducto ( Composite ) 19.6.37 3.5 X 35 Sq. Mm Al Conductor ( Only Supply ) 19.6.38 3.5 X 35 Sq. Mm Al Conductor ( Only Labour ) 19.6.39 3.5 X 35 Sq. Mm Al Conductor ( Composite ) 19.6.40 3.5 X 50 Sq. Mm Al Conducto ( Only Supply ) 19.6.41 3.5 X 50 Sq. Mm Al Conducto ( Only Labour ) 19.6.42 3.5 X 50 Sq. Mm Al Conducto ( Composite ) 19.6.43 3.5 X 70 Sq. Mm Al Conductor ( Only Supply ) 19.6.44 3.5 X 70 Sq. Mm Al Conductor ( Only Lanbour ) 19.6.45 3.5 X 70 Sq. Mm Al Conductor ( Composite ) 19.6.46 3.5 X 95 Sq. Mm Al Conductor ( Only Supply ) 19.6.47 3.5 X 95 Sq. Mm Al Conductor ( Only Labour ) 19.6.48 3.5 X 95 Sq. Mm Al Conductor ( Composite ) 19.7 Supply, Installation, Testing & Commissioning Of 1.1 Kv Grade Pvc Insulated Stranded / Round Wire Armoured Aluminium Conductor Power Cables Isi Mark Fixed On Wall / Coloum / Ceiling Or In Shaft / Existing Trench With Screws / Coach Screws / Anchor Fasteners, All Other Fixing Accessories Etc. As Per Instruction Of Engg-In-Charge. & Following Size Along With Double Run Continuous 8 Swg Copper Bare Wire For Earthing & End Termination. 19.7.1 3.5 X 120 Sq. Mm Al Conductor ( Only Supply ) 19.7.2 3.5 X 120 Sq. Mm Al Conductor ( Only Labour ) 19.7.3 3.5 X 120 Sq. Mm Al Conductor ( Composite ) 19.7.4 3.5 X 150 Sq. Mm Al Conductor ( Only Supply ) 19.7.5 3.5 X 150 Sq. Mm Al Conductor ( Only Labour ) 19.7.6 3.5 X 150 Sq. Mm Al Conductor ( Compoiste ) 19.7.7 3.5 X 185 Sq. Mm Al Conductor ( Only Supply ) 19.7.8 3.5 X 185 Sq. Mm Al Conductor ( Only Labour ) 19.7.9 3.5 X 185 Sq. Mm Al Conductor ( Composite ) 19.7.10 3.5 X 240 Sq. Mm Al Conductor ( Only Supply ) 19.7.11 3.5 X 240 Sq. Mm Al Conductor ( Only Labour ) 19.7.12 3.5 X 240 Sq. Mm Al Conductor ( Composite ) 19.7.13 3.5 X 300 Sq. Mm Al Conductor ( Only Supply ) 19.7.14 3.5 X 300 Sq. Mm Al Conductor ( Only Labour ) 19.7.15 3.5 X 300 Sq. Mm Al Conductor ( Composite ) 19.7.16 3.5 X 400 Sq. Mm Al Conductor ( Only Supply ) 19.7.17 3.5 X 400 Sq. Mm Al Conductor ( Only Labour ) 19.7.18 3.5 X 400 Sq. Mm Al Conductor ( Composite ) 19.8 Supply, Laying, Testing & Commissioning Of 1.1 Kv Ac Grade Pvc Insulated Isi Mark Armored, Bright Annealed Aluminium Conductor Cable Below Earth 900 Mm. Cable In The Ground Shall Be Covered On Top & Sides With Baked Bricks Conforming To Is 107 Including Dewatering, Sand Bedding, Back Filling & Re-Instatement, Consolidation & Removal Of Excess Earth With In A Radius Of 500 Mtr As Per Instruction Of E-I-C. 19.8.1 3.5 X 120 Sq. Mm Al Conductor ( Only Supply ) 19.8.2 3.5 X 120 Sq. Mm Al Conductor ( Only Labour ) 19.8.3 3.5 X 120 Sq. Mm Al Conductor ( Composite ) 19.8.4 3.5 X 150 Sq. Mm Al Conductor ( Only Supply ) 19.8.5 3.5 X 150 Sq. Mm Al Conductor ( Only Labour ) 19.8.6 3.5 X 150 Sq. Mm Al Conductor ( Compoiste ) 19.8.7 3.5 X 185 Sq. Mm Al Conductor ( Only Supply ) 19.8.8 3.5 X 185 Sq. Mm Al Conductor ( Only Labour ) 19.8.9 3.5 X 185 Sq. Mm Al Conductor ( Composite ) 19.8.10 3.5 X 240 Sq. Mm Al Conductor ( Only Supply ) 19.8.11 3.5 X 240 Sq. Mm Al Conductor ( Only Labour ) 19.8.12 3.5 X 240 Sq. Mm Al Conductor ( Composite ) 19.8.13 3.5 X 300 Sq. Mm Al Conductor ( Only Supply ) 19.8.14 3.5 X 300 Sq. Mm Al Conductor ( Only Labour ) 19.8.15 3.5 X 300 Sq. Mm Al Conductor ( Composite ) 19.8.16 3.5 X 400 Sq. Mm Al Conductor ( Only Supply ) 19.8.17 3.5 X 400 Sq. Mm Al Conductor ( Only Labour ) 19.8.18 3.5 X 400 Sq. Mm Al Conductor ( Composite ) 19.9 Supply, Laying, Testing & Commissioning Of 1.1 Kv Ac Grade Pvc Insulated Isi Mark Armored, Bright Annealed Aluminium Conductor Cable In Ground At 900 Mm Through Suitable Size Of Dwc Hdpe Pipes, Along With Cable Pulling Chamber With Heavy Duty Openable Cover At The Both End & If Required In Between As Directed By In-Charge, Back Filling & Re-Instatement, Consolidation & Removal Of Excess Earth With In A Radius Of 500 Mtr. As Per Instruction Of E-I-C. 19.9.1 3.5 X 120 Sq. Mm Al Conductor ( Only Supply ) 19.9.2 3.5 X 120 Sq. Mm Al Conductor ( Only Labour ) 19.9.3 3.5 X 120 Sq. Mm Al Conductor ( Composite ) 19.9.4 3.5 X 150 Sq. Mm Al Conductor ( Only Supply ) 19.9.5 3.5 X 150 Sq. Mm Al Conductor ( Only Labour ) 19.9.6 3.5 X 150 Sq. Mm Al Conductor ( Compoiste ) 19.9.7 3.5 X 185 Sq. Mm Al Conductor ( Only Supply ) 19.9.8 3.5 X 185 Sq. Mm Al Conductor ( Only Labour ) 19.9.9 3.5 X 185 Sq. Mm Al Conductor ( Composite ) 19.9.10 3.5 X 240 Sq. Mm Al Conductor ( Only Supply ) 19.9.11 3.5 X 240 Sq. Mm Al Conductor ( Only Labour ) 19.9.12 3.5 X 240 Sq. Mm Al Conductor ( Composite ) 19.9.13 3.5 X 300 Sq. Mm Al Conductor ( Only Supply ) 19.9.14 3.5 X 300 Sq. Mm Al Conductor ( Only Labour ) 19.9.15 3.5 X 300 Sq. Mm Al Conductor ( Composite ) 19.9.16 3.5 X 400 Sq. Mm Al Conductor ( Only Supply ) 19.9.17 3.5 X 400 Sq. Mm Al Conductor ( Only Labour ) 19.9.18 3.5 X 400 Sq. Mm Al Conductor ( Composite ) 19.10.A Supply, Installation, Testing & Commissioning Of Compact Circular Aluminum Conductor, Conductor Screened With Extruded Semi-Conducting Compound Xlpe Insulated, Insulation Screened With Extruded Semi-Conducting Compound In Combination With Copper Tape ( 0.3 Ka For One Sec. ) , Cores Laid Up, Inner Sheath Of Pvc Tape, Galvanized Steel Flat Strip Armoured & Overall Pvs Sheathed Cable With Latest Amendments, 11 / 33 Kv Grade Cable, Isi Mark Make Fixed On Wall / Coloum / Ceiling Or In Shaft / Existing Trench With Screws / Coach Screws / Anchor Fasteners, All Other Fixing Accessories Etc. As Per Instruction Of Engg-In-Charge. & Following Size Along With Double Run Continuous Copper Strip / Wire Earthing As Required & As Directed By O-I-C, Es. 19.10.1 3 X 240 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Supply ) 19.10.2 3 X 240 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Labour ) 19.10.3 3 X 240 Sq. Mm. Al Conductor ( 11 Kv ) ( Composite ) 19.10.4 3 X 300 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Supply ) 19.10.5 3 X 300 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Labour ) 19.10.6 3 X 300 Sq. Mm. Al Conductor ( 11 Kv ) ( Composite ) 19.10.7 3 X 400 Sq. Mm Al Conductor ( 11 Kv ) ( Only Supply ) 19.10.8 3 X 400 Sq. Mm Al Conductor ( 11 Kv ) ( Only Labour ) 19.10.9 3 X 400 Sq. Mm Al Conductor ( 11 Kv ) ( Composite ) 19.10.10 3 X 240 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Supply ) 19.10.11 3 X 240 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Labour ) 19.10.12 3 X 240 Sq. Mm. Al Conductor ( 33 Kv ) ( Composite ) 19.10.13 3 X 300 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Supply ) 19.10.14 3 X 300 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Labour ) 19.10.15 3 X 300 Sq. Mm. Al Conductor ( 33 Kv ) ( Composite ) 19.10.16 3 X 400 Sq. Mm Al Conductor ( 33 Kv ) ( Only Supply ) 19.10.17 3 X 400 Sq. Mm Al Conductor ( 33 Kv ) ( Only Labour ) 19.10.18 3 X 400 Sq. Mm Al Conductor ( 33 Kv ) ( Composite ) 19.11 Supply, Laying, Testing & Commissioning Of Compact Circular Aluminum Conductor, Conductor Screened With Extruded Semi-Conducting Compound Xlpe Insulated, Insulation Screened With Extruded Semi-Conducting Compound In Combination With Copper Tape ( 0.3 Ka For One Sec. ) , Cores Laid Up, Inner Sheath Of Pvc Tape, Galvanized Steel Flat Strip Armoured & Overall Pvs Sheathed Cable With Latest Amendments, 11 / 33 Kv Grade Cable, Isi Mark Pvc Insulated Isi Mark Armored, Bright Annealed Copper Conductor Cable Below Earth 1200 Mm. Cable In The Ground Shall Be Covered On Top & Sides With Baked Bricks Conforming To Is 107 Including Dewatering, Sand Bedding, Back Filling & Re-Instatement, Consolidation & Removal Of Excess Earth With In A Radius Of 500 Mtr As Per Instruction Of E-I-C. 19.11.1 3 X 240 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Supply ) 19.11.2 3 X 240 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Labour ) 19.11.3 3 X 240 Sq. Mm. Al Conductor ( 11 Kv ) ( Composite ) 19.11.4 3 X 300 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Supply ) 19.11.5 3 X 300 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Labour ) 19.11.6 3 X 300 Sq. Mm. Al Conductor ( 11 Kv ) ( Composite ) 19.11.7 3 X 400 Sq. Mm Al Conductor ( 11 Kv ) ( Only Supply ) 19.11.8 3 X 400 Sq. Mm Al Conductor ( 11 Kv ) ( Only Labour ) 19.11.9 3 X 400 Sq. Mm Al Conductor ( 11 Kv ) ( Composite ) 19.11.10 3 X 240 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Supply ) 19.11.11 3 X 240 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Labour ) 19.11.12 3 X 240 Sq. Mm. Al Conductor ( 33 Kv ) ( Composite ) 19.11.13 3 X 300 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Supply ) 19.11.14 3 X 300 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Labour ) 19.11.15 3 X 300 Sq. Mm. Al Conductor ( 33 Kv ) ( Composite ) 19.11.16 3 X 400 Sq. Mm Al Conductor ( 33 Kv ) ( Only Supply ) 19.11.17 3 X 400 Sq. Mm Al Conductor ( 33 Kv ) ( Only Labour ) 19.11.18 3 X 400 Sq. Mm Al Conductor ( 33 Kv ) ( Composite ) 19.12 Supply, Laying, Testing & Commissioning Of Compact Circular Aluminum Conductor, Conductor Screened With Extruded Semi-Conducting Compound Xlpe Insulated, Insulation Screened With Extruded Semi-Conducting Compound In Combination With Copper Tape ( 0.3 Ka For One Sec. ) , Cores Laid Up, Inner Sheath Of Pvc Tape, Galvanized Steel Flat Strip Armoured & Overall Pvs Sheathed Cable With Latest Amendments, 11Kv Grade Cable, Isi Mark , Laying In Ground At 1200 Mm Through Suitable Size Of Dwc Hdpe Pipes, Along With Cable Pulling Chamber With Heavy Duty Openable Cover At The Both End & If Required In Between As Directed By In-Charge, Back Filling & Re-Instatement, Consolidation & Removal Of Excess Earth With In A Radius Of 500 Mtr. As Per Instruction Of E-I-C. 19.12.1 3 X 240 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Supply ) 19.12.2 3 X 240 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Labour ) 19.12.3 3 X 240 Sq. Mm. Al Conductor ( 11 Kv ) ( Composite ) 19.12.4 3 X 300 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Supply ) 19.12.5 3 X 300 Sq. Mm. Al Conductor ( 11 Kv ) ( Only Labour ) 19.12.6 3 X 300 Sq. Mm. Al Conductor ( 11 Kv ) ( Composite ) 19.12.7 3 X 400 Sq. Mm Al Conductor ( 11 Kv ) ( Only Supply ) 19.12.8 3 X 400 Sq. Mm Al Conductor ( 11 Kv ) ( Only Labour ) 19.12.9 3 X 400 Sq. Mm Al Conductor ( 11 Kv ) ( Composite ) 19.12.10 3 X 240 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Supply ) 19.12.11 3 X 240 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Labour ) 19.12.12 3 X 240 Sq. Mm. Al Conductor ( 33 Kv ) ( Composite ) 19.12.13 3 X 300 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Supply ) 19.12.14 3 X 300 Sq. Mm. Al Conductor ( 33 Kv ) ( Only Labour ) 19.12.15 3 X 300 Sq. Mm. Al Conductor ( 33 Kv ) ( Composite ) 19.12.16 3 X 400 Sq. Mm Al Conductor ( 33 Kv ) ( Only Supply ) 19.12.17 3 X 400 Sq. Mm Al Conductor ( 33 Kv ) ( Only Labour ) 19.12.18 3 X 400 Sq. Mm Al Conductor ( 33 Kv ) ( Composite ) 20.1 Gi Pipes / Foot Valvessupply, Installation Gi Pipes Class B Type With All Fixing Arrangement Such As Couplings, Bends Etc On Any Kind Of Surface Or Below Ground As Per The Instruction Of E-I-C. 20.1.1 Gi Pipe 25 Mm ( Only Supply ) 20.1.2 Gi Pipe 25 Mm ( Only Labour ) 20.1.3 Gi Pipe 25 Mm ( Composite ) 20.1.4 Gi Pipe 32 Mm ( Only Supply ) 20.1.5 Gi Pipe 32 Mm ( Only Labour ) 20.1.6 Gi Pipe 32 Mm ( Composite ) 20.1.7 Gi Pipe 38 Mm ( Only Supply ) 20.1.8 Gi Pipe 38 Mm ( Only Labour ) 20.1.9 Gi Pipe 38 Mm ( Composite ) 20.1.10 Gi Pipe 50 Mm ( Only Supply ) 20.1.11 Gi Pipe 50 Mm ( Only Labour ) 20.1.12 Gi Pipe 50 Mm ( Composite ) 20.2 Supply / Replacement Of Foot Valve Of Various Sizes With All Necessary Arrangement For Making It Properly Function, All As Per The Instructions And As Per Directions Of E-I-C, Es 20.2.1 Threefourth Inch ( Only Supply ) 20.2.2 Threefourth Inch ( Only Labour ) 20.2.3 Threefourth Inch ( Composite ) 20.2.4 1Inch ( Only Supply ) 20.2.5 1Inch ( Only Labour ) 20.2.6 1Inch ( Composite ) 20.2.7 2Inch ( Only Supply ) 20.2.8 2Inch ( Only Labour ) 20.2.9 2Inch ( Composite ) 20.2.10 3Inch ( Only Supply ) 20.2.11 3Inch ( Only Labour ) 20.2.12 3Inch ( Composite ) 20.3 Exavation / Hume Pipes / Dwc Pipes 20.3.1 Supply, Installation Of Oval / Circular Shape Gi Casted Cable Marker Complete With 38 M Dia Gi Support 1: 3: 6 Pcc Base, Concreting / Gi Nut Bolts, Engraved As Ht / Mv / Lt / Tel.Cables Etc. As Per Instruction Of Eic. All As Directed By O-I-C With Prior Approval. ( Composite ) 20.3.2 Exavation Of All Kind Of Soil As Per Required 900 Mm Below Ground Level Including Blasting & Chiseling, Using Compressor, Dewatering, Back Filling, Reinstatement, After Work Completion, If Necessary Disposal Of Excess Earth Within The Radius Of 500 Mtrs Etc, Stacking Of Rocks At Selected Places As Per Instruction Of Eic. ( Composite ) 20.3.3 Exavation Of Hard Rock As Per Reuired 900 / 1200 Mm Below Ground Level Including Blasting & Chiseling, Using Compressor, Dewatering, Back Filling, If Necessary Disposal Of Excess Earth Within The Radius Of 500 Mtrs Etc. Stacking Of Rocks At Selected Places As Per Instruction Of Eic. ( Composite ) 20.3.4 Supply & Laying Of Rcc Hume Pipe 150 Mm Dia Along With Collars Including Exavation In All Types Of Soils / Rock / Asphalts Road / Comcrete Road / Jointing Of Pipes With Cement, Consolidating & Making Good Surface As Per The Existing All As Per The Instructions Of Eic. ( Only Supply ) 20.3.5 Supply & Istallation Of Rcc Hume Pipe 150 Mm Dia Along With Collars Including Exavation In All Types Of Soils / Rock / Asphalts Road / Comcrete Road / Jointing Of Pipes With Cement, Consolidating & Making Good Surface As Per The Existing All As Per The Instructions Of Eic. ( Only Labour ) 20.3.6 Supply & Istallation Of Rcc Hume Pipe 150 Mm Dia Along With Collars Including Exavation In All Types Of Soils / Rock / Asphalts Road / Comcrete Road / Jointing Of Pipes With Cement, Consolidating & Making Good Surface As Per The Existing All As Per The Instructions Of Eic. ( Composite ) 20.3.4 Supply & Laying Of Rcc Hume Pipe 400 Mm Dia Along With Collars Including Exavation In All Types Of Soils / Rock / Asphalts Road / Comcrete Road / Jointing Of Pipes With Cement, Consolidating & Making Good Surface As Per The Existing All As Per The Instructions Of Eic. ( Only Supply ) 20.3.5 Supply & Istallation Of Rcc Hume Pipe400 Mm Dia Along With Collars Including Exavation In All Types Of Soils / Rock / Asphalts Road / Comcrete Road / Jointing Of Pipes With Cement, Consolidating & Making Good Surface As Per The Existing All As Per The Instructions Of Eic. ( Only Labour ) 20.3.6 Supply & Istallation Of Rcc Hume Pipe 400 Mm Dia Along With Collars Including Exavation In All Types Of Soils / Rock / Asphalts Road / Comcrete Road / Jointing Of Pipes With Cement, Consolidating & Making Good Surface As Per The Existing All As Per The Instructions Of Eic. ( Composite ) 21 Supply, Laying, Testing & Commissioning Of Rg-11 Television Cable Through Casing Capping / Pvc Conduits / Gi-Ms Pipes On Any Kind Of Surface / Below Ground Through Dwc Pipe Through Out The Campus As Per Requirment With All Accessories And Fixing Arrangement All As Per Instructions & As Directed By E-I-C, Es. 21.1 Rg 11 Cable ( Only Supply ) 21.2 Rg 11 Cable Supply And Laying Pvc Casing Capping / Conduit Pipe ( Composite ) 21.3 Rg 11 Cable Laying Through Dwc Hdpe Pipe Pipe ( Composite ) 21.10.A Supply Of Rg-59 Television Cable As Per Requirment With All Accessories And Fixing Arrangement All As Per Instructions & As Directed By E-I-C, Es ( Only Supply ) 21.11 Laying Of Rg-59 Television Cable Through Provided Casing Capping / Pvc Conduits / Gi-Ms Pipes On Any Kind Of Surface As Per Requirment With All Accessories And Fixing Arrangement All As Per Instructions & As Directed By E-I-C, Es ( Only Labour ) 21.12 Supply, Laying, Testing & Commissioning Of Rg-59 Television Cable Of Through Provided Casing Capping / Pvc Conduits / Gi-Ms Pipes On Any Kind Of Surface As Per Requirment With All Accessories And Fixing Arrangement All As Per Instructions & As Directed By E-I-C, Es ( Composite ) 21.13 Supply Of Rg-6 Television Cable As Per Requirment With All Accessories And Fixing Arrangement All As Per Instructions & As Directed By E-I-C, Es ( Only Supply ) 21.14 Laying Of Rg-6 Television Cable Through Provided Casing Capping / Pvc Conduits / Gi-Ms Pipes Any Kind Of Surface As Per Requirment With All Accessories And Fixing Arrangement All As Per Instructions & As Directed By E-I-C, Es ( Only Labour ) 21.15 Supply, Laying, Testing & Commissioning Of Rg-6 Television Cable Of Through Provided Casing Capping / Pvc Conduits / Gi-Ms Pipes On Any Kind Of Surface As Per Requirment With All Accessories And Fixing Arrangement All As Per Instructions & As Directed By E-I-C, Es ( Composite ) 22 Corrogated Water Pipe 22.1 Supply / Replacement Of Corrogated Water Pipe With Prior Approval Will All Accessories And Fixing Arrangement, All As Per Instructions And As Directed By E-I-C, Es. 22.1.1 Threefourth Inch ( Only Supply ) 22.1.2 Threefourth Inch ( Only Labour ) 22.1.3 Threefourth Inch ( Composite ) 22.1.4 1Inch ( Only Supply ) 22.1.5 1Inch ( Only Labour ) 22.1.6 1Inch ( Composite ) 22.1.7 2Inch ( Only Supply ) 22.1.8 2Inch ( Only Labour ) 22.1.9 2Inch ( Composite ) 22.1.10 3Inch ( Only Supply ) 22.1.11 3Inch ( Only Labour ) 22.1.12 3Inch ( Composite ) 23.1 Telephone Cable / Joint Kits / Tag Blockssupply, Installation, Testing & Commissioning Of Telephone Cables With Tinned Grade Annealed Copper Conductor Pe Insulated Cores Twisted Jelly Filled Gi Wire / Strip Armored Pvc Sheathed Cable Fixed On Slab / Wall / Coloum / Existing Trench Etc. On 6 Mm Thick Gi Spacer / Ms Flat Support With Wooden Screws With 18 Swg Gi Saddle All Fixing Accessories & Jointing Of The Both The Ends Of Cable S With All Jointing Materials Like Cable Glands, Cable End Box If Required, Ferrule Lugs, Ferrule Numbers, Wire Dressing Clamps / Buttons Etc. Complete All As Per Instruction Of E-I-C. 23.1.1 As Per Item No 23.1 But For 0.5 Mm Dia 10 Pair. ( Only Supply ) 23.1.2 As Per Item No 23.1 But For 0.5 Mm Dia 10 Pair. ( Only Labour ) 23.1.3 As Per Item No 23.1 But For 0.5 Mm Dia 10 Pair. ( Composite ) 23.1.4 As Per Item No 23.1 But For 0.5 Mm Dia 20 Pair. ( Only Supply ) 23.1.5 As Per Item No 23.1 But For 0.5 Mm Dia 20 Pair. ( Only Labour ) 23.1.6 As Per Item No 23.1 But For 0.5 Mm Dia 20 Pair. ( Composite ) 23.1.7 As Per Item No 23.1 But For 0.5 Mm Dia 50 Pair. ( Only Supply ) 23.1.8 As Per Item No 23.1 But For 0.5 Mm Dia 50 Pair. ( Only Labour ) 23.1.9 As Per Item No 23.1 But For 0.5 Mm Dia 50 Pair. ( Composite ) 23.1.10 As Per Item No 23.1 But For 0.5 Mm Dia 100 Pair. ( Only Supply ) 23.1.11 As Per Item No 23.1 But For 0.5 Mm Dia 100 Pair. ( Only Labour ) 23.1.12 As Per Item No 23.1 But For 0.5 Mm Dia 100 Pair. ( Composite ) 23.1.13 As Per Item No 23.1 But For 0.5 Mm Dia 200 Pair. ( Only Supply ) 23.1.14 As Per Item No 23.1 But For 0.5 Mm Dia 200 Pair. ( Only Labour ) 23.1.15 As Per Item No 23.1 But For 0.5 Mm Dia 200 Pair. ( Composite ) 23.2 Supply Installation, Testing & Commissioning Of Telephone Cables With Tinned Grade Annealed Copper Conductor Pe Insulated Cores Twisted Jelly Filled Gi Wire / Strip Armored Pvc Sheathed In Ground At The Depth Of 700 Mm Below Ground Level Including Excavation Of All Type Of Soil / Sand Bedding Laying Of Backed Bricks As Per Is On Side & Top, Back Filling Dewatering Shoring, Consolidating, Disposal Of Excess Earth Within A Radius Of 500 Meters, Total Reinstatement After Work Completion Etc. Complete As Per The Instruction Of E-I-C. 23.2.1 As Per Item No 23.2 But For 0.5 Mm Dia 10 Pair. ( Only Supply ) 23.2.2 As Per Item No 23.2 But For 0.5 Mm Dia 10 Pair. ( Only Labour ) 23.2.3 As Per Item No 23.2 But For 0.5 Mm Dia 10 Pair. ( Composite ) 23.2.4 As Per Item No 23.2 But For 0.5 Mm Dia 20 Pair. ( Only Supply ) 23.2.5 As Per Item No 23.2 But For 0.5 Mm Dia 20 Pair. ( Only Labour ) 23.2.6 As Per Item No 23.2 But For 0.5 Mm Dia 20 Pair. ( Composite ) 23.2.7 As Per Item No 23.2 But For 0.5 Mm Dia 50 Pair. ( Only Supply ) 23.2.8 As Per Item No 23.2 But For 0.5 Mm Dia 50 Pair. ( Only Labour ) 23.2.9 As Per Item No 23.2 But For 0.5 Mm Dia 50 Pair. ( Composite ) 23.2.10 As Per Item No 23.2 But For 0.5 Mm Dia 100 Pair. ( Only Supply ) 23.2.11 As Per Item No 23.2 But For 0.5 Mm Dia 100 Pair. ( Only Labour ) 23.2.12 As Per Item No 23.2 But For 0.5 Mm Dia 100 Pair. ( Composite ) 23.2.13 As Per Item No 23.2 But For 0.5 Mm Dia 200 Pair. ( Only Supply ) 23.2.14 As Per Item No 23.2 But For 0.5 Mm Dia 200 Pair. ( Only Labour ) 23.2.15 As Per Item No 23.2 But For 0.5 Mm Dia 200 Pair. ( Composite ) 23.3 Supply Installation, Testing & Commissioning Of Telephone Cables With Tinned Grade Annealed Copper Conductor Pe Insulated Cores Twisted Jelly Filled Gi Wire / Strip Armored Pvc Sheathed In Ground At The Depth Of 700 Mm Below Ground Level Including Excavation Of All Type Of Laying Through Suitable Dwc Hdpe Pipe, Along With Cable Pulling Chamber With Heavy Duty Openable Cover At The Both End & If Required In Between As Directed By In-Charge Dewatering Shoring, Consolidating, Disposal Of Excess Earth Within A Radius Of 500 Meters, Total Reinstatement After Work Completion Etc. Complete As Per The Instruction Of E-I-C. 23.3.1 As Per Item No 23.3 But For 0.5 Mm Dia 10 Pair. ( Only Supply ) 23.3.2 As Per Item No 23.3 But For 0.5 Mm Dia 10 Pair. ( Only Labour ) 23.3.3 As Per Item No 23.3 But For 0.5 Mm Dia 10 Pair. ( Composite ) 23.3.4 As Per Item No 23.3 But For 0.5 Mm Dia 20 Pair. ( Only Supply ) 23.3.5 As Per Item No 23.3 But For 0.5 Mm Dia 20 Pair. ( Only Labour ) 23.3.6 As Per Item No 23.3 But For 0.5 Mm Dia 20 Pair. ( Composite ) 23.3.7 As Per Item No 23.3 But For 0.5 Mm Dia 50 Pair. ( Only Supply ) 23.3.8 As Per Item No 23.3 But For 0.5 Mm Dia 50 Pair. ( Only Labour ) 23.3.9 As Per Item No 23.3 But For 0.5 Mm Dia 50 Pair. ( Composite ) 23.3.10 As Per Item No 23.3 But For 0.5 Mm Dia 100 Pair. ( Only Supply ) 23.3.11 As Per Item No 23.3 But For 0.5 Mm Dia 100 Pair. ( Only Labour ) 23.3.12 As Per Item No 23.3 But For 0.5 Mm Dia 100 Pair. ( Composite ) 23.3.13 As Per Item No 23.3 But For 0.5 Mm Dia 200 Pair. ( Only Supply ) 23.3.14 As Per Item No 23.3 But For 0.5 Mm Dia 200 Pair. ( Only Labour ) 23.3.15 As Per Item No 23.3 But For 0.5 Mm Dia 200 Pair. ( Composite ) 23.4 Supply, Installation, Testing & Commissioning Of Straight Through Telephone Jointing Kits Preferably Of Raychem Make Or Alternately M Seal Of Mahindra Make For Jelly Filled Armoured Telephone Cable Including Dressing, Cleaning Of The Jelly, Supply Of All Jointing Materials, Etc. Complete As Required And As Per Relevant Specifications And As Directed By E-I-C. 23.4.1 As Per Item No 23.4 But For 10 Pairs Jelly Filled Armoured Cable ( Only Supply ) 23.4.2 As Per Item No 23.4 But For 10 Pairs Jelly Filled Armoured Cable ( Only Labour ) 23.4.3 As Per Item No 23.4 But For 10 Pairs Jelly Filled Armoured Cable ( Composite ) 23.4.4 As Per Item No 23.4 But For 20 Pairs Jelly Filled Armoured Cable ( Only Supply ) 23.4.5 As Per Item No 23.4 But For 20 Pairs Jelly Filled Armoured Cable ( Only Labour ) 23.4.6 As Per Item No 23.4 But For 20 Pairs Jelly Filled Armoured Cable ( Composite ) 23.4.7 As Per Item No 23.4 But For 50 Pairs Jelly Filled Armoured Cable ( Only Supply ) 23.4.8 As Per Item No 23.4 But For 50 Pairs Jelly Filled Armoured Cable ( Only Labour ) 23.4.9 As Per Item No 23.4 But For 50 Pairs Jelly Filled Armoured Cable ( Composite ) 23.4.10 As Per Item No 23.4 But For 100 Pairs Jelly Filled Armoured Cable ( Only Supply ) 23.4.11 As Per Item No 23.4 But For 100 Pairs Jelly Filled Armoured Cable ( Only Labour ) 23.4.12 As Per Item No 23.4 But For 100 Pairs Jelly Filled Armoured Cable ( Composite ) 23.4.13 As Per Item No 23.4 But For 200 Pairs Jelly Filled Armoured Cable ( Only Supply ) 23.4.14 As Per Item No 23.4 But For 200 Pairs Jelly Filled Armoured Cable ( Only Labour ) 23.4.15 As Per Item No 23.4 But For 200 Pairs Jelly Filled Armoured Cable ( Composite ) 23.5 Supply, Installation, Testing & Commissioning Of Crone Connector Telephone Tag Block Box, Fabricated Out Of 14 Swg Ms Crca Sheet Mounted On Ms Frame Of Size 40 X 40 X 5 Mm & Grouted On The Wall / Fixed On The Coloum Free Standing Type With Anchor Fastener With Front Openable Hinged Doors Cam Type Locking Arrangements, Neoprene Gasket For Joints Painting With Seven Tank Metal Treatment Process & With Two Coats Of Red Oxide Primer & Two Coats Of Approved Shade Enamel Paint, Norm Plate Etc. As Per The Instruction Of Eic. 23.5.1 2 X 10 Ways Telephone Tag Block. ( Only Supply ) 23.5.2 2 X 10 Ways Telephone Tag Block. ( Only Labour ) 23.5.3 2 X 10 Ways Telephone Tag Block. ( Composite ) 23.5.4 2 X 20 Ways Telephone Tag Block. ( Only Supply ) 23.5.5 2 X 20 Ways Telephone Tag Block. ( Only Labour ) 23.5.6 2 X 20 Ways Telephone Tag Block. ( Composite ) 23.5.7 2 X 50 Ways Telephone Tag Block. ( Only Supply ) 23.5.8 2 X 50 Ways Telephone Tag Block. ( Only Labour ) 23.5.9 2 X 50 Ways Telephone Tag Block. ( Composite ) 23.5.10 2 X 60 Ways Telephone Tag Block. ( Only Supply ) 23.5.11 2 X 60 Ways Telephone Tag Block. ( Only Labour ) 23.5.12 2 X 60 Ways Telephone Tag Block. ( Composite ) 23.5.13 2 X 100 Ways Telephone Tag Block. ( Only Supply ) 23.5.14 2 X 100 Ways Telephone Tag Block. ( Only Labour ) 23.5.15 2 X 100 Ways Telephone Tag Block. ( Composite ) 23.5.16 2 X 200 Ways Telephone Tag Block. ( Only Supply ) 23.5.17 2 X 200 Ways Telephone Tag Block. ( Only Labour ) 23.5.18 2 X 200 Ways Telephone Tag Block. ( Composite ) 23.5.19 2 X 240 Ways Telephone Tag Block. ( Only Supply ) 23.5.20 2 X 240 Ways Telephone Tag Block. ( Only Labour ) 23.5.21 2 X 240 Ways Telephone Tag Block. ( Composite ) 23.5.22 Supply & Fixing Of 10 Way Crone Connectors Of Good Quality With Prior Approval. ( Only Supply ) 23.5.23 Supply & Fixing Of 10 Way Crone Connectors Of Good Quality With Prior Approval. ( Only Labour ) 23.5.24 Supply & Fixing Of 10 Way Crone Connectors Of Good Quality With Prior Approval. ( Composite ) 24.1 Cable Glands And Lugssupplying & Erecting Heavy Duty Flange Type Brass Cable Glands For End Jointing Of Various Sizes For Pvc Armoured Cable With Brass Washers, Rubber Rings Complete With Cable Ends & Leads Connected, With Gland Double Earthing, Work Completed In All Respect All As Per Instructions And As Directed By E-I-C, Es 24.1.1 Supplying & Erecting Heavy Duty Flange Type Brass Cable Glands For End Jointing 2 To 4 Core 2.5 Sq. Mm / 2 To 4 Core 6 Sq. Mm Pvc Armoured Cable With Brass Washers, Rubber Rings Complete With Cable Ends & Leads Connected ( Only Supply ) 24.1.2 Supplying & Erecting Heavy Duty Flange Type Brass Cable Glands For End Jointing 2 To 4 Core 2.5 Sq. Mm / 2 To 4 Core 6 Sq. Mm Pvc Armoured Cable With Brass Washers, Rubber Rings Complete With Cable Ends & Leads Connected ( Only Labour ) 24.1.3 Supplying & Erecting Heavy Duty Flange Type Brass Cable Glands For End Jointing 2 To 4 Core 2.5 Sq. Mm / 2 To 4 Core 6 Sq. Mm Pvc Armoured Cable With Brass Washers, Rubber Rings Complete With Cable Ends & Leads Connected ( Composite ) 24.1.4 As Per Item No 24.1 But For But 3 To 4 Core X 6 Sq. Mm / 2 To 4 Core X 10 Sq. Mm As Per Item No 24.1 But For ( Only Supply ) 24.1.5 As Per Item No 24.1 But For 3 To 4 Core X 6 Sq. Mm / 2 To 4 Core X 10 Sq. Mm Same As Above ( Only Labour ) 24.1.6 Same As Abovebut 3 To 4 Core X 6 Sq. Mm / 2 To 4 Core X 10 Sq. Mm Same As Above ( Composite ) 24.1.7 As Per Item No 24.1 But For 3 To 4 Core X 16 Sq. Mm / 3.5 To 4 Core X 25 Sq. Mm / 3 X 35 Sq.Mmsame As Above ( Only Supply ) 24.1.8 As Per Item No 24.1 But For 3 To 4 Core X 16 Sq. Mm / 3.5 To 4 Core X 25 Sq. Mm / 3 X 35 Sq.Mmsame As Above ( Only Labour ) 24.1.9 As Per Item No 24.1 But For 3 To 4 Core X 16 Sq. Mm / 3.5 To 4 Core X 25 Sq. Mm / 3 X 35 Sq.Mmsame As Above ( Composite ) 24.1.10 As Per Item No 24.1 But For 3.5X35sq.Mm / 3X50sq.Mm Same As Above ( Only Supply ) 24.1.11 As Per Item No 24.1 But For 3.5X35sq.Mm / 3X50sq.Mm Same As Above ( Only Labour ) 24.1.12 As Per Item No 24.1 But For 3.5X35sq.Mm / 3X50sq.Mm Same As Above ( Composite ) 24.1.13 As Per Item No 24.1 But For 3.5 X 50 Sq.Mm Same As Above ( Only Supply ) 24.1.14 As Per Item No 24.1 But For 3.5 X 50 Sq.Mm Same As Above ( Only Labour ) 24.1.15 As Per Item No 24.1 But For 3.5 X 50 Sq.Mm Same As Above ( Composite ) 24.1.16 As Per Item No 24.1 But For 3.5 X 70 Sq.Mm Same As Above ( Only Supply ) 24.1.17 As Per Item No 24.1 But For 3.5 X 70 Sq.Mm Same As Above ( Only Labour ) 24.1.18 As Per Item No 24.1 But For 3.5 X 70 Sq.Mm Same As Above ( Composite ) 24.1.19 As Per Item No 24.1 But For 3.5 X 95 Sq.Mm Same As Above ( Only Supply ) 24.1.20 As Per Item No 24.1 But For 3.5 X 95 Sq.Mm Same As Above ( Only Labour ) 24.1.21 As Per Item No 24.1 But For 3.5 X 95 Sq.Mmsame As Above ( Composite ) 24.1.22 As Per Item No 24.1 But For 3.5 X 120 Sq.Mm Same As Above ( Only Supply ) 24.1.23 As Per Item No 24.1 But For 3.5 X 120 Sq.Mmsame As Above ( Only Labour ) 24.1.24 As Per Item No 24.1 But For 3.5 X 120 Sq.Mm Same As Above ( Composite ) 24.1.25 As Per Item No 24.1 But For 3.5 X 150 Sq.Mm Same As Above ( Only Supply ) 24.1.26 As Per Item No 24.1 But For 3.5 X 150 Sq.Mm Same As Above ( Only Labour ) 24.1.27 As Per Item No 24.1 But For 3.5 X 150 Sq.Mmsame As Above ( Composite ) 24.1.28 As Per Item No 24.1 But For 3.5 X 185 Sq.Mmsame As Above ( Only Supply ) 24.1.29 As Per Item No 24.1 But For 3.5 X 185 Sq.Mmsame As Above ( Only Labour ) 24.1.30 As Per Item No 24.1 But For 3.5 X 185 Sq.Mm Same As Above ( Compsite ) 24.1.31 As Per Item No 24.1 But For 3.5 X 240 Sq.Mm Same As Above ( Only Supply ) 24.1.32 As Per Item No 24.1 But For 3.5 X 240 Sq.Mm Same As Above ( Only Labour ) 24.1.33 As Per Item No 24.1 But For 3.5 X 240 Sq.Mm Same As Above ( Composite ) 24.1.34 As Per Item No 24.1 But For 3.5 X 300 Sq.Mmsame As Above ( Only Supply ) 24.1.35 As Per Item No 24.1 But For 3.5 X 300 Sq.Mm Same As Above ( Only Labour ) 24.1.36 As Per Item No 24.1 But For 3.5 X 300 Sq.Mm Same As Above ( Composite ) 24.1.37 As Per Item No 24.1 But For 3.5 X 400 Sq.Mmsame As Above ( Only Supply ) 24.1.38 As Per Item No 24.1 But For 3.5 X 400 Sq.Mm Same As Above ( Only Labour ) 24.1.39 As Per Item No 24.1 But For 3.5 X 400 Sq.Mm Same As Above ( Composite ) 24.2 Lugs Supplying & Erecting Crimping Type Copper Lugs Confirming To Is Suitable For Various Core Sizes Evenly Crimped With High Pressure Tools & Connected To Switch Gear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manners Along With Lug Crimping Pest Etc All As Directed By E-I-C, Es. 24.2.1 Supplying & Erecting Crimping Type Copper Lugs Confirming To Is Suitable For Cables Up To 16 Sq. Mm Evenly Crimped With High Pressure Tools & Connected To Switch Gear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manners. All As Directed By O-I-C, Es ( Only Supply ) 24.2.2 Supplying & Erecting Crimping Type Copper Lugs Confirming To Is Suitable For Cables Up To 16 Sq. Mm Evenly Crimped With High Pressure Tools & Connected To Switch Gear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manners. All As Directed By O-I-C, Es ( Only Labour ) 24.2.3 Supplying & Erecting Crimping Type Copper Lugs Confirming To Is Suitable For Cables Up To 16 Sq. Mm Evenly Crimped With High Pressure Tools & Connected To Switch Gear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manners. All As Directed By O-I-C, Es ( Composite ) 24.2.4 As Per Item No 24.2 But For 25 Sq. Mmas Per Item No 24.2 But For ( Only Supply ) 24.2.5 As Per Item No 24.2 But For 25 Sq. Mmas Per Item No 24.2 But For ( Only Labour ) 24.2.6 As Per Item No 24.2 But For 25 Sq. Mm As Per Item No 24.2 But For ( Composite ) 24.2.7 As Per Item No 24.2 But For 35 Sq. Mm As Per Item No 24.2 But For ( Only Supply ) 24.2.8 As Per Item No 24.2 But For 35 Sq. Mm As Per Item No 24.2 But For ( Only Labour ) 24.2.9 As Per Item No 24.2 But For 35 Sq. Mmas Per Item No 24.2 But For ( Composite ) 24.2.10 As Per Item No 24.2 But For 50 Sq. Mm As Per Item No 24.2 But For ( Only Supply ) 24.2.11 As Per Item No 24.2 But For 50 Sq. Mm As Per Item No 24.2 But For ( Only Labour ) 24.2.12 As Per Item No 24.2 But For 50 Sq. Mm As Per Item No 24.2 But For ( Composite ) 24.2.13 As Per Item No 24.2 But For 70 Sq. Mm As Per Item No 24.2 But For ( Only Supply ) 24.2.14 As Per Item No 24.2 But For 70 Sq. Mmas Per Item No 24.2 But For ( Only Labour ) 24.2.15 As Per Item No 24.2 But For 70 Sq. Mm As Per Item No 24.2 But For ( Composite ) 24.2.16 As Per Item No 24.2 But For 95 Sq. Mmas Per Item No 24.2 But For ( Only Supply ) 24.2.17 As Per Item No 24.2 But For 95 Sq. Mm As Per Item No 24.2 But For ( Only Labour ) 24.2.18 As Per Item No 24.2 But For 95 Sq. Mmas Per Item No 24.2 But For ( Composite ) 24.2.19 As Per Item No 24.2 But For 120 Sq. Mmas Per Item No 24.2 But For ( Only Supply ) 24.2.20 As Per Item No 24.2 But For 120 Sq. Mm As Per Item No 24.2 But For ( Only Labour ) 24.2.21 As Per Item No 24.2 But For 120 Sq. Mm As Per Item No 24.2 But For ( Composite ) 24.2.22 As Per Item No 24.2 But For 150 Sq. Mmas Per Item No 24.2 But For ( Only Supply ) 24.2.23 As Per Item No 24.2 But For 150 Sq. Mmas Per Item No 24.2 But For ( Only Labour ) 24.2.24 As Per Item No 24.2 But For 150 Sq. Mm As Per Item No 24.2 But For ( Composite ) 24.2.25 As Per Item No 24.2 But For 185 Sq. Mmas Per Item No 24.2 But For ( Only Supply ) 24.2.26 As Per Item No 24.2 But For 185 Sq. Mm As Per Item No 24.2 But For ( Only Labour ) 24.2.27 As Per Item No 24.2 But For 185 Sq. Mmas Per Item No 24.2 But For ( Composite ) 24.2.28 As Per Item No 24.2 But For 240 Sq. Mmas Per Item No 24.2 But For ( Only Supply ) 24.2.29 As Per Item No 24.2 But For 240 Sq. Mm As Per Item No 24.2 But For ( Only Labour ) 24.2.30 As Per Item No 24.2 But For 240 Sq. Mmas Per Item No 24.2 But For ( Composite ) 24.2.31 As Per Item No 24.2 But For 300 Sq. Mmas Per Item No 24.2 But For ( Only Supply ) 24.2.32 As Per Item No 24.2 But For 300 Sq. Mm As Per Item No 24.2 But For ( Only Labour ) 24.2.33 As Per Item No 24.2 But For 300 Sq. Mmas Per Item No 24.2 But For ( Composite ) 24.2.34 As Per Item No 24.2 But For 400 Sq. Mmas Per Item No 24.2 But For ( Only Supply ) 24.2.35 As Per Item No 24.2 But For 400 Sq. Mm As Per Item No 24.2 But For ( Only Labour ) 24.2.36 As Per Item No 24.2 But For 400 Sq. Mm As Per Item No 24.2 But For ( Composite ) 24.3 Supplying & Erecting Crimping Type Aluminium Lugs Confirming To Is Suitable For Various Core Sizes Evenly Crimped With High Pressure Tools & Connected To Switch Gear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manners Along With Lug Crimping Pest Etc All As Directed By E-I-C, Es. 24.3.1 Supplying & Erecting Crimping Type Al Lugs Confirming To Is Suitable For Cables Up To 16 Sq. Mm Evenly Crimped With High Pressure Tools & Connected To Switch Gear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manner.All As Directed By O-I-C, Es ( Only Supply ) 24.3.2 Supplying & Erecting Crimping Type Al Lugs Confirming To Is Suitable For Cables Up To 16 Sq. Mm Evenly Crimped With High Pressure Tools & Connected To Switch Gear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manner.All As Directed By O-I-C, Es ( Only Labour ) 24.3.3 Supplying & Erecting Crimping Type Al Lugs Confirming To Is Suitable For Cables Up To 16 Sq. Mm Evenly Crimped With High Pressure Tools & Connected To Switch Gear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manner.All As Directed By O-I-C, Es ( Composite ) 24.3.4 As Per Item No 24.3 But For 25 Sq. Mm As Per Item No 24.3 But For ( Only Supply ) 25.1 Flexible Cable / Borewell Cablesupply & Fixing Of White / Black Colour Pvc Insulation Of Various Sizes Of Flexible Cables As Required With Necessary Fixing Arrangement, Connection At The Both The End Using Suitable Lugs Etc. All As Directed By O-I-C, Es. 25.1.1 3 X 1.5 Sq. Mm Flexible Cable ( Only Supply ) 25.1.2 3 X 1.5 Sq. Mm Flexible Cable ( Only Labour ) 25.1.3 3 X 1.5 Sq. Mm Flexible Cable ( Composite ) 25.1.4 3 X 2.5 Sq. Mm Pvc Flexible Cable ( Only Supply ) 25.1.5 3 X 2.5 Sq. Mm Pvc Flexible Cable ( Only Labour ) 25.1.6 3 X 2.5 Sq. Mm Pvc Flexible Cable ( Composite ) 25.1.7 3 X 4 Sq. Mm Pvc Flexible Cable ( Only Supply ) 25.1.8 3 X 4 Sq. Mm Pvc Flexible Cable ( Only Labour ) 25.1.9 3 X 4 Sq. Mm Pvc Flexible Cable ( Composite ) ) 25.1.10 2 X 1.5 Sq. Mm Pvc Flexible Cable ( Only Supply ) 25.1.11 2 X 1.5 Sq. Mm Pvc Flexible Cable ( Only Labour ) 25.1.12 2 X 1.5 Sq. Mm Pvc Flexible Cable ( Composite ) 25.1.13 2 X 2.5 Sq. Mm Pvc Flexible Cable ( Only Supply ) 25.1.14 2 X 2.5 Sq. Mm Pvc Flexible Cable ( Only Labour ) 25.1.15 2 X 2.5 Sq. Mm Pvc Flexible Cable ( Composite ) 25.1.16 4 X 2.5 Sq. Mm Pvc Flexible Cable ( Only Supply ) 25.1.17 4 X 2.5 Sq. Mm Pvc Flexible Cable ( Only Labour ) 25.1.18 4 X 2.5 Sq. Mm Pvc Flexible Cable ( Composite ) 25.1.19 4 X 4 Sq. Mm Pvc Flexible Cable ( Only Supply ) 25.1.20 4 X 4 Sq. Mm Pvc Flexible Cable ( Only Labour ) 25.1.21 4 X 4 Sq. Mm Pvc Flexible Cable ( Composite ) 25.2 Supply & Fixing Of Pvc Insulated Various Sizes Of Flexible Cables As Required With Necessary Fixing Arrangement, Connection At The Both The End Using Suitable Lugs Etc For Bore Well Connection, All As Directed By O-I-C, Es. 25.2.1 3C X 1.5 Sq. Mm Cable ( Only Supply ) 25.2.2 3C X 1.5 Sq. Mm Cable ( Only Labour ) 25.2.3 3C X 1.5 Sq. Mm Cable ( Composite ) 25.2.4 3C X 2.5 Sq. Mm Cable ( Only Supply ) 25.2.5 3C X 2.5 Sq. Mm Cable ( Only Labour ) 25.2.6 3C X 2.5 Sq. Mm Cable ( Composite ) 25.2.7 3C X 4 Sq. Mm Cable ( Only Supply ) 25.2.8 3C X 4 Sq. Mm Cable ( Only Labour ) 25.2.9 3C X 4 Sq. Mm Cable ( Composite ) 26 Water Level Controller 26.1 Supply, Installation, Testing & Commissioning Of Water Level Controller For Maintaining Of Desired Level Of Water In Water Tank Etc, Having All Sensing Mechanium In Place, As Complete Unit, With All Other Necessary Arrangement Of Proper Finctioning Etc, All As Per Instruction And As Per Derection Of E-I-C, Es 26.1.1 Automatic Water Level Controller With Sensor ( Only Supply ) 26.1.2 Automatic Water Level Controller With Sensor ( Only Labour ) 26.1.3 Automatic Water Level Controller With Sensor ( Composite ) 26.1.4 Sensor For Water Level Controller ( Only Supply ) 26.1.5 Sensor For Water Level Controller ( Only Labour ) 26.1.6 Sensor For Water Level Controller ( Composite ) 26.1.7 Supplying And Erecting Centrifugal Water Pump ( Monoblock ) , 415V, 3 Phase, 50Hz, A.C. Supply, Of 3 Hp With Discharge 2 / 4.1 Liters Per Sec. For Head Of 36 / 52 M And 50Mm Suction / 40Mm Delivery Pipe On Provided Cement Concrete Foundation As Per Specification And Instruction Of Engg. - In-Charge. ( Only Supply ) 26.1.8 Supplying And Erecting Centrifugal Water Pump ( Monoblock ) , 415V, 3 Phase, 50Hz, A.C. Supply, Of 3 Hp With Discharge 2 / 4.1 Liters Per Sec. For Head Of 36 / 52 M And 50Mm Suction / 40Mm Delivery Pipe On Provided Cement Concrete Foundation As Per Specification And Instruction Of Engg. - In-Charge. ( Only Labour ) 26.1.9 Supplying And Erecting Centrifugal Water Pump ( Monoblock ) , 415V, 3 Phase, 50Hz, A.C. Supply, Of 3 Hp With Discharge 2 / 4.1 Liters Per Sec. For Head Of 36 / 52 M And 50Mm Suction / 40Mm Delivery Pipe On Provided Cement Concrete Foundation As Per Specification And Instruction Of Engg. - In-Charge. ( Composite ) 26.1.10 Supplying And Erecting Centrifugal Water Pump ( Monoblock ) , 415V, 3 Phase, 50Hz, A.C. Supply, Of 5 Hp With Discharge 5.8 / 8.5 Liters Per Sec. For Head Of 20 / 36 M And 65 Mm Suction / 50Mm Delivery Pipe On Provided Cement Concrete Foundation As Per Specification And Instruction Of Engg. - In-Charge. ( Only Supply ) 26.1.11 Supplying And Erecting Centrifugal Water Pump ( Monoblock ) , 415V, 3 Phase, 50Hz, A.C. Supply, Of 5 Hp With Discharge 2 / 4.1 Liters Per Sec. For Head Of 36 / 52 M And 50Mm Suction / 40Mm Delivery Pipe On Provided Cement Concrete Foundation As Per Specification And Instruction Of Engg. - In-Charge. ( Only Labour ) 26.1.12 Supplying And Erecting Centrifugal Water Pump ( Monoblock ) , 415V, 3 Phase, 50Hz, A.C. Supply, Of 5 Hp With Discharge 2 / 4.1 Liters Per Sec. For Head Of 36 / 52 M And 50Mm Suction / 40Mm Delivery Pipe On Provided Cement Concrete Foundation As Per Specification And Instruction Of Engg. - In-Charge. ( Composite ) 26.1.13 Supplying And Erecting Submercible Water Pump Set Suitable For Erection On Open Well Of 5Hp With 415V, 3 Phase, 50Hz, A.C. Supply, Having Delivery Head 36M And Discharge From 400 To 1600 Ltrs Per Minute ( Max. Efficiency At 21 M Head And 680 Ltr Discharge ) And Delivery Pipe Of Necessary Dia. Erected With Necessary H Type Clamp As Per Specification And Instruction Of Engg. In-Charge. ( Only Supply ) 26.1.14 Supplying And Erecting Submercible Water Pump Set Suitable For Erection On Open Well Of 5Hp With 415V, 3 Phase, 50Hz, A.C. Supply, Having Delivery Head 36M And Discharge From 400 To 1600 Ltrs Per Minute ( Max. Efficiency At 21 M Head And 680 Ltr Discharge ) And Delivery Pipe Of Necessary Dia. Erected With Necessary H Type Clamp As Per Specification And Instruction Of Engg. In-Charge. ( Only Labour ) 26.1.15 Supplying And Erecting Submercible Water Pump Set Suitable For Erection On Open Well Of 5 Hp With 415V, 3 Phase, 50Hz, A.C. Supply, Having Delivery Head 36M And Discharge From 400 To 1600 Ltrs Per Minute ( Max. Efficiency At 21 M Head And 680 Ltr Discharge ) And Delivery Pipe Of Necessary Dia. Erected With Necessary H Type Clamp As Per Specification And Instruction Of Engg. In-Charge. ( Composite ) 26.1.16 Supplying And Erecting Submercible Water Pump Set Suitable For Erection On Open Well Of Required Hp With 415V, 3 Phase, 50Hz, A.C. Supply, Having Delivery Head From 20 To 10M And Discharge From 450 To 1600 Ltrs Per Minute ( Max. Efficiency At 17 M Head And 1250 Ltr Discharge ) And Delivery Pipe Of Necessary Dia. Erected With Necessary H Type Clamp As Per Specification And Instruction Of Engg. - In-Charge. ( Only Supply ) 26.1.17 Supplying And Erecting Submercible Water Pump Set Suitable For Erection On Open Well Of Required Hp With 415V, 3 Phase, 50Hz, A.C. Supply, Having Delivery Head From 20 To 10M And Discharge From 450 To 1600 Ltrs Per Minute ( Max. Efficiency At 17 M Head And 1250 Ltr Discharge ) And Delivery Pipe Of Necessary Dia. Erected With Necessary H Type Clamp As Per Specification And Instruction Of Engg. - In-Charge. ( Only Labour ) 26.1.18 Supplying And Erecting Submercible Water Pump Set Suitable For Erection On Open Well Of Required Hp With 415V, 3 Phase, 50Hz, A.C. Supply, Having Delivery Head From 20 To 10M And Discharge From 450 To 1600 Ltrs Per Minute ( Max. Efficiency At 17 M Head And 1250 Ltr Discharge ) And Delivery Pipe Of Necessary Dia. Erected With Necessary H Type Clamp As Per Specification And Instruction Of Engg. - In-Charge. ( Composite ) 27.1 Earthingsupplying & Installation Of Tinned Copper Strip / Bare Copper Wire For Earthing System Fixed On Wall / Side Of The Trench / Slab / Coloum / Beam Along With Clips / Saddle And Spacers Etc. Including End Connection With Crimping Type Copper Lugs Complete In All Respect, With Continity Test Etc & All As Directed By Engg. -In-Charge. 27.1.1 8 Swg Tinned Copper Bare Wire ( 1 Run ) ( Only Supply ) 27.1.2 8 Swg Tinned Copper Bare Wire ( 1 Run ) ( Only Labour ) 27.1.3 8 Swg Tinned Copper Bare Wire ( 1 Run ) ( Composite ) 27.1.4 10 Swg Tinned Copper Bare Wire ( 1 Run ) ( Only Supply ) 27.1.5 10 Swg Tinned Copper Bare Wire ( 1 Run ) ( Only Labour ) 27.1.6 10 Swg Tinned Copper Bare Wire ( 1 Run ) ( Composite ) 27.1.7 12 Swg Tinned Copper Bare Wire ( 1 Run ) ( Only Supply ) 27.1.8 12 Swg Tinned Copper Bare Wire ( 1 Run ) ( Only Labour ) 27.1.9 12 Swg Tinned Copper Bare Wire ( 1 Run ) ( Only Composite ) 27.1.10 14 Swg Tinned Copper Bare Wire ( 1 Run ) ( Only Supply ) 27.1.11 14 Swg Tinned Copper Bare Wire ( 1 Run ) ( Only Labour ) 27.1.12 14 Swg Tinned Copper Bare Wire ( 1 Run ) ( Composite ) 27.1.13 16 Swg Tinned Copper Bare Wire ( 1 Run ) ( Only Supply ) 27.1.14 16 Swg Tinned Copper Bare Wire ( 1 Run ) ( Only Labour ) 27.1.15 16 Swg Tinned Copper Bare Wire ( 1 Run ) ( Composite ) 27.1.16 Copper Strip Of Size 25 X 3 Mm ( 1 Run ) ( Only Supply ) 27.1.17 Copper Strip Of Size 25 X 3 Mm ( 1 Run ) ( Only Labour ) 27.1.18 Copper Strip Of Size 25 X 3 Mm ( 1 Run ) ( Composite ) 27.1.19 Copper Strip Of Size 25 X 5 Mm ( 1 Run ) ( Only Supply ) 27.1.20 Copper Strip Of Size 25 X 5 Mm ( 1 Run ) ( Only Labour ) 27.1.21 Copper Strip Of Size 25 X 5 Mm ( 1 Run ) ( Composite ) 27.1.22 Copper Strip Of Size 50 X 6 Mm ( 1 Run ) ( Only Supply ) 27.1.23 Copper Strip Of Size 50 X 6 Mm ( 1 Run ) ( Only Labour ) 27.1.24 Copper Strip Of Size 50 X 6 Mm ( 1 Run ) ( Composite ) 27.2 Gi Earthing Strip Supplying & Installation Of Tinned Gi Strip / Bare Gi Wire For Earthing System Fixed On Wall / Side Of The Trench / Slab / Coloum / Beam Along With Clips / Saddle And Spacers Etc. Including End Connection With Crimping Type Copper Lugs Complete In All Respect, With Continuty Test Etc & All As Directed By Engg. -In-Charge. 27.2.1 Gi Strip Size 25 X 3 Mm ( 1 Run ) ( Only Supply ) 27.2.2 Gi Strip Size 25 X 3 Mm ( 1 Run ) ( Only Labour ) 27.2.3 Gi Strip Size 25 X 3 Mm ( 1 Run ) ( Compsite ) 27.2.4 Gi Strip Size 25 X 5 Mm ( 1 Run ) ( Only Supply ) 27.2.5 Gi Strip Size 25 X 5 Mm ( 1 Run ) ( Only Labour ) 27.2.6 Gi Strip Size 25 X 5 Mm ( 1 Run ) ( Compsite ) 27.2.7 Gi Wire 8 Swg, ( 1 Run ) ( Only Supply ) 27.2.8 Gi Wire 8 Swg, ( 1 Run ) ( Only Labour ) 27.2.9 Gi Wire 8 Swg, ( 1 Run ) ( Composite ) 27.3 Earting Stations / Pits 27.3.1 Maintenance Of Earthing Pits Treated Type With Charcoal , Salt , Water As Per Standard Practice. 27.3.2 Tinned Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Earth Station, 2.5 Mtr Below Ground Level As Per Drawing Complete With All Required Materials Like Cole, Charcoal, Salt, Brass Nut Bolts & Washers, Watering Arrangements, Gi Pipe ( B Class ) , Concrete Chamber, Heavy Duty Cast Iron Cover Plate & Excavation In All Types Of Soil In Ground Refilling & Removal Excess Earth Within A Radius Of 500 Mtr. Etc. ( 2 Nos, Of Neutral Earthing Of T / F, 2 Nos. For T / F Body Earthing & 2 Nos. For Panel Earthing ) Hot Dipped Gi Earth Plate Electrode 600 X 600 X 6.3 Mm Earth Station 2.5 Mtr Below The Ground Level --- Same As Above-- As Per Drawing & Specifications Complete With All Required Materials Like Coke / Charcoal, Salts , Brass Nut Bolts & Washers, Watering Arrangement, Gu Pipe ( B Class ) Concrete / Brick Chamber, Heavy Duty Cast Iron Cover Plate & Excavation In Ground, Refilling & Removing Of Excess Earth Within A Radius Of 500 Mtr.Etc. Scope Also Includes Dewatering, Shoring, & Consolidation Etc. ( Composite ) 27.4 Air Terminator / Lightening Arrestor 27.4.1 Air Terminator Consisting Of 75 To 100 Mm Dia & 6 Mm Thick Tin Copper Sphere With 5 Nos Of Spikes Of 6 Mm Dia, 100 Mm Long, 19 Mm Dia 600 Mm Long Tinned Copper Rod 150 Mm Dia 10 Mm Thickness Tinned Copper Flange, 200 X 200 X 10 Mm Tinned Brass Plate Gi Grouting Bolts / Anchor Fasteners Etc. ( Composite ) 28.1 Cable Jointing Straight Through Jointing For 1.1 Kv Pvc Insulated Al / Copper Conductors Cable Including Supply Of All Jointing Materials Like Sleeves, Tinned Copper Cable Sockets / Ferrules Terminal Protector Comprising Of Insulating Sleeves & Grommets Etc Similar To Pre-Molded Push-On Type Raychem Cable Termination & Earthing Complete As Required & Tested As Per Relevant Is Specification Including Testing & Commissioning All As Per Instruction E-I-C. 28.1.1 3.5 X 10 Sq. Mm Copper ( Only Supply ) 28.1.2 3.5 X 10 Sq. Mm Copper ( Only Labour ) 28.1.3 3.5 X 10 Sq. Mm Copper ( Composite ) 28.1.4 3.5 X 16 Sq. Mm Copper ( Only Supply ) 28.1.5 3.5 X 16 Sq. Mm Copper ( Only Labour ) 28.1.6 3.5 X 16 Sq. Mm Copper ( Composite ) 28.1.7 3.5 X 25 Sq. Mm Copper ( Only Supply ) 28.1.8 3.5 X 25 Sq. Mm Copper ( Only Labour ) 28.1.9 3.5 X 25 Sq. Mm Copper ( Composite ) 28.1.10 3.5 X 35 Sq. Mm Copper ( Only Supply ) 28.1.11 3.5 X 35 Sq. Mm Copper ( Only Labour ) 28.1.12 3.5 X 35 Sq. Mm Copper ( Composite ) 28.1.13 3.5 X 50 Sq. Mm Copper ( Only Supply ) 28.1.14 3.5 X 50 Sq. Mm Copper ( Only Labour ) 28.1.15 3.5 X 50 Sq. Mm Copper ( Composite ) 28.1.16 3.5 X 70 Sq. Mm Copper ( Only Supply ) 28.1.17 3.5 X 70 Sq. Mm Copper ( Only Labour ) 28.1.18 3.5 X 70 Sq. Mm Copper ( Composite ) 28.1.19 3.5 X 95 Sq. Mm Copper ( Only Supply ) 28.1.20 3.5 X 95 Sq. Mm Copper ( Only Labour ) 28.1.21 3.5 X 95 Sq. Mm Copper ( Composite ) 28.1.22 3.5 X 120 Sq. Mm Copper ( Only Supply ) 28.1.23 3.5 X 120 Sq. Mm Copper ( Only Labour ) 28.1.24 3.5 X 120 Sq. Mm Copper ( Composite ) 28.1.25 3.5 X 150 Sq. Mm Copper ( Only Supply ) 28.1.26 3.5 X 150 Sq. Mm Copper ( Only Labour ) 28.1.27 3.5 X 150 Sq. Mm Copper ( Composite ) 28.1.28 3.5 X 185 Sq. Mm Copper ( Only Supply ) 28.1.29 3.5 X 185 Sq. Mm Copper ( Only Labour ) 28.1.30 3.5 X 185 Sq. Mm Copper ( Composite ) 28.1.31 3.5 X 240 Sq. Mm Copper ( Only Supply ) 28.1.32 3.5 X 240 Sq. Mm Copper ( Only Labour ) 28.1.33 3.5 X 240 Sq. Mm Copper ( Composite ) 28.1.34 3.5 X 300 Sq. Mm Copper ( Only Supply ) 28.1.35 3.5 X 300 Sq. Mm Copper ( Only Labour ) 28.1.36 3.5 X 300 Sq. Mm Copper ( Composite ) 28.1.37 3.5 X 400 Sq. Mm Copper ( Only Supply ) 28.1.38 3.5 X 400 Sq. Mm Copper ( Only Labour ) 28.1.39 3.5 X 400 Sq. Mm Copper ( Composite ) 28.2 Straight Through Jointing For 11 / 33 Kv Xlpe Insulated Al Conductors Cable Including Supply Of All Jointing Materials Like Sleeves, Tinned Copper Cable Sockets / Ferrules Terminal Protector Comprising Of Insulating Sleeves & Grommets Etc Similar To Pre-Molded Push-On Type Raychem Cable Termination & Earthing Complete As Required & Tested As Per Relevant Is Specification Including Testing & Commissioning All As Per Instruction E-I-C. 28.2.1 As Described Above, 11Kv, 3 X 240 Sq.Mm Xlpe ( Only Supply ) 28.2.2 As Described Above, 11Kv, 3 X 240 Sq.Mm Xlpe ( Only Labour ) 28.2.3 As Described Above, 11Kv, 3 X 240 Sq.Mm Xlpe ( Composite ) 28.2.4 As Described Above, 33Kv, 3 X 300 Sq. Mm Xlpe ( Only Supply ) 28.2.5 As Described Above, 33Kv, 3 X 300 Sq. Mm Xlpe ( Only Labour ) 28.2.6 As Described Above, 33Kv, 3 X 300 Sq. Mm Xlpe ( Composite ) 29.1 Switch Board For Ac Pointfabrication / & Supply, Installation. Testing & Commissioning Of Ms Box Made Out Of 16 / 14 Swg Ms Sheet With Removable Top Cover Of 3 Mm White Hylam Sheet / Ms Sheet With Screws, Cup Washer Etc. & Complete Concealed In Wall With Their Following Accessories Mounted On It & Their Inter Connection With 2.5 / 4 Sq. Mm Pvc Insulated Copper Cord Wire. All As Required & As Directed By O-I-C, Es. 29.1.1 20 Amps 2 Pin + Earth ( As 20 ) Reroll Type Crompton / Mds Or Approved Make Metalic Sockets- 1 No / / / / 20 Amps Mds Make Dp Mcb With Separate Neutral Link As Controling S / W - 1No. / / / / 20 Amps Crompton Make Metalic Top- 1 No. For Above Socket. ( Only Supply ) 29.1.2 20 Amps 2 Pin + Earth ( As 20 ) Reroll Type Crompton / Mds Or Approved Make Metalic Sockets- 1 No / / / / 20 Amps Mds Make Dp Mcb With Separate Neutral Link As Controling S / W - 1No. / / / / 20 Amps Crompton Make Metalic Top- 1 No. For Above Socket. ( Only Labour ) 29.1.3 20 Amps 2 Pin + Earth ( As 20 ) Reroll Type Crompton / Mds Or Approved Make Metalic Sockets- 1 No / / / / 20 Amps Mds Make Dp Mcb With Separate Neutral Link As Controling S / W - 1No. / / / / 20 Amps Crompton Make Metalic Top- 1 No. For Above Socket. ( Composite ) 29.1.4 As Per Item No 29.1 But For 40 Amps Dp Mcb & Socket ( Only Supply ) 29.1.5 As Per Item No 29.1 But For 40 Amps Dp Mcb & Socket ( Only Labour ) 29.1.6 As Per Item No 29.1 But For 40 Amps Dp Mcb & Socket ( Composite ) 29.1.7 32 Amps 4 Pin + Earth Reroll Type Crompton / Mds / Cutler Hammer Or Approved Make Metallic Socket. - 1 No. / 32 Amps Mds Make Tpn Mcb As A Controlling S / W – 1 No / 32 Amps Crompton / Mds / Cutler Hammer Make Top ( Only Supply ) 29.1.8 32 Amps 4 Pin + Earth Reroll Type Crompton / Mds / Cutler Hammer Or Approved Make Metallic Socket. - 1 No. / 32 Amps Mds Make Tpn Mcb As A Controlling S / W – 1 No / 32 Amps Crompton / Mds / Cutler Hammer Make Top ( Only Labour ) 29.1.9 32 Amps 4 Pin + Earth Reroll Type Crompton / Mds / Cutler Hammer Or Approved Make Metallic Socket. - 1 No. / 32 Amps Mds Make Tpn Mcb As A Controlling S / W – 1 No / 32 Amps Crompton / Mds / Cutler Hammer Make Top ( Composite ) 29.2 Replacement For Item No 29.1 29.2.1 Replacement Of 20 Amps, Reroll Type Metallic Spn Sockets ( Only Supply ) 29.2.2 Replacement Of 20 Amps, Reroll Type Metallic Spn Sockets ( Only Labour ) 29.2.3 Replacement Of 20 Amps, Reroll Type Metallic Spn Sockets ( Composite ) 29.2.4 Replacement Of 32 Amps, Reroll Type Metallic Spn Sockets ( Only Supply ) 29.2.5 Replacement Of 32 Amps, Reroll Type Metallic Spn Sockets ( Only Labour ) 29.2.6 Replacement Of 32 Amps, Reroll Type Metallic Spn Sockets ( Composite ) 29.2.7 Replacement Of 40 Amps, Reroll Type Metallic Spn Sockets ( Only Supply ) 29.2.8 Replacement Of 40 Amps, Reroll Type Metallic Spn Sockets ( Only Labour ) 29.2.9 Replacement Of 40 Amps, Reroll Type Metallic Spn Sockets ( Composite ) 29.2.10 Replacement Of 63 Amps, Reroll Type Metallic Spn Sockets ( Only Supply ) 29.2.11 Replacement Of 63 Amps, Reroll Type Metallic Spn Sockets ( Only Labour ) 29.2.12 Replacement Of 63 Amps, Reroll Type Metallic Spn Sockets ( Composite ) 29.2.13 Supply & Fixing Metallic Top For 10 Amps 2P+E ( Only Supply ) 29.2.14 Supply & Fixing Metallic Top For 10 Amps 2P+E ( Only Labour ) 29.2.15 Supply & Fixing Metallic Top For 10 Amps 2P+E ( Composite ) 29.2.16 As Per Item No 29.2.13 But For 20 Amps ( Only Supply ) 29.2.17 As Per Item No 29.2.13 But For 20 Amps ( Only Labour ) 29.2.18 As Per Item No 29.2.13 But For 20 Amps ( Composite ) 29.2.19 As Per Item No 29.2.13 But For 32 Amps ( Only Supply ) 29.2.20 As Per Item No 29.2.13 But For 32 Amps ( Only Labour ) 29.2.21 As Per Item No 29.2.13 But For 32 Amps ( Composite ) 29.2.22 As Per Item No 29.2.13 But For 40 Amps ( Only Supply ) 29.2.23 As Per Item No 29.2.13 But For 40 Amps ( Only Labour ) 29.2.24 As Per Item No 29.2.13 But For 40 Amps ( Composite ) 29.2.25 Supplying & Fixing Metallic Top 32 Amps, 3 P + E ( Only Supply ) 29.2.26 Supplying & Fixing Metallic Top 32 Amps, 3 P + E ( Only Labour ) 29.2.27 Supplying & Fixing Metallic Top 32 Amps, 3 P + E ( Composite ) 29.2.28 Spike Guard Of Approved Make For Computer ( Only Supply ) 29.2.29 Heavy Duty Spike Guard Of Approved Make For Equipments ( Only Supply ) 30.1 Distribution Boards Providing & Erecting Distribution Made Out Of 2 Mm Thick ( In Case Of Fabrication ) Ms Crca Sheet With Concealed Hinges, Mounted On Ms Angle Frame & Grouted On The Wall / Fixed On The Coloum With Anchor Fastener With Earthing Terminal, Neutral Link, Interconnection With Adequate Size Of Bus-Bar / Wires, Interior Of The Db Shall Be Covered With 3 Mm Thick Frp Sheet With Necessary Cut Out, Neoprene Gasket, Painting With Seven Tank Metal Treatment Process ( Shade To Be Got Approved ) / Powder Coating All As Per Instructions Of E-I--C, Complete In All Respect. 30.1.1.1 Lighting Distribution Boardsall As Per Item No 30.1 For 40 Amps Tpn Mcb-- 1 No / / / .25Amps Dp Elcb ( 30Ma ) -- 3 Nos / / / .6 Amps Sp Mcb ( 8 Ways ) -- 24 Nos. ( Only Supply ) 30.1.1.2 All As Per Item No 30.1 For 40 Amps Tpn Mcb-- 1 No / / / .25Amps Dp Elcb ( 30Ma ) -- 3 Nos / / / .6 Amps Sp Mcb ( 8 Ways ) -- 24 Nos. ( Only Labour ) 30.1.1.3 All As Per Item No 30.1 For 40 Amps Tpn Mcb-- 1 No / / / .25Amps Dp Elcb ( 30Ma ) -- 3 Nos / / / .6 Amps Sp Mcb ( 8 Ways ) -- 24 Nos. ( Composite ) 30.1.1.4 All As Per Item No 30.1 For 40 Amps Dp Elmcb--1 No. / / / 6 / 16 Amps Sp Mcb-- 8 Nos. ( Only Supply ) 30.1.1.5 All As Per Item No 30.1 For 40 Amps Dp Elmcb--1 No. / / / 6 / 16 Amps Sp Mcb-- 8 Nos. ( Only Labour ) 30.1.1.6 All As Per Item No 30.1 For 40 Amps Dp Elmcb--1 No. / / / 6 / 16 Amps Sp Mcb-- 8 Nos. ( Composite ) 30.1.2 Power Distribution Boards 30.1.2.1 All As Per Item No 30.1 For 63 Amps Tpn Mcb--1 No. / / / 40 Amps Dp Elcb ( 30 Ma ) --3 Nos / / / 16 Amps Sp Mcb ( 8Ways ) --24 Nos. ( Only Supply ) 30.1.2.2 All As Per Item No 30.1 For 63 Amps Tpn Mcb--1 No. / / / 40 Amps Dp Elcb ( 30 Ma ) --3 Nos / / / 16 Amps Sp Mcb ( 8Ways ) --24 Nos. ( Only Labour ) 30.1.2.3 All As Per Item No 30.1 For 63 Amps Tpn Mcb--1 No. / / / 40 Amps Dp Elcb ( 30 Ma ) --3 Nos / / / 16 Amps Sp Mcb ( 8Ways ) --24 Nos. ( Composite ) 30.1.2.4 All As Per Item No 30.1 For 100 Amps Tpn Mcb / Isolator--1 No. / / / 63 Amps Dp Elcb ( 100 Ma ) --3 Nos. / / / 16 Amps Sp Mcb ( 12 Ways ) --36 Nos. ( Only Supply ) 30.1.2.5 All As Per Item No 30.1 For 100 Amps Tpn Mcb / Isolator--1 No. / / / 63 Amps Dp Elcb ( 100 Ma ) --3 Nos. / / / 16 Amps Sp Mcb ( 12 Ways ) --36 Nos. ( Only Labour ) 30.1.2.6 All As Per Item No 30.1 For 100 Amps Tpn Mcb / Isolator--1 No. / / / 63 Amps Dp Elcb ( 100 Ma ) --3 Nos. / / / 16 Amps Sp Mcb ( 12 Ways ) --36 Nos. ( Composite ) 30.1.3 Ready Made Distribution Boards Supply, Erection, Testing & Commissioning Of Sheet Metal Powered Coated Distribution Boards Inclusive Of Mcbs With Bus Bar, Neutral Link & Connection Wire Set Etc Of Mds / Siemens Make Confirming To Ip-42. All As Required & Directed By O-I-C, Es With Prior Approval. 30.1.3.1 Spn 4 Way ( Only Supply ) 30.1.3.2 Spn 4 Way ( Only Labour ) 30.1.3.3 Spn 4 Way ( Composite ) 30.1.3.4 Spn 6 Way ( Only Supply ) 30.1.3.5 Spn 6 Way ( Only Labour ) 30.1.3.6 Spn 6 Way ( Composite ) 30.1.3.7 Spn 8 Way ( Only Supply ) 30.1.3.8 Spn 8 Way ( Only Labour ) 30.1.3.9 Spn 8 Way ( Composite ) 30.1.3.10 Spn 12 Way ( Only Supply ) 30.1.3.11 Spn 12 Way ( Only Labour ) 30.1.3.12 Spn 12 Way ( Composite ) 30.1.3.13 Tpn 4 Way ( Only Supply ) 30.1.3.14 Tpn 4 Way ( Only Labour ) 30.1.3.15 Tpn 4 Way ( Composite ) 30.1.3.16 Tpn 6 Way ( Only Supply ) 30.1.3.17 Tpn 6 Way ( Only Labour ) 30.1.3.18 Tpn 6 Way ( Composite ) 30.1.3.19 Tpn 8 Way ( Only Supply ) 30.1.3.20 Tpn 8 Way ( Only Labour ) 30.1.3.21 Tpn 8 Way ( Composite ) 30.1.3.22 Tpn 12 Way ( Only Supply ) 30.1.3.23 Tpn 12 Way ( Only Labour ) 30.1.3.24 Tpn 12 Way ( Composite ) 30.1.4.1 Aluminum Anodized Name Plates For Circuit Identification With Prior Approval. ( Only Supply ) 30.1.4.2 Aluminum Anodized Name Plates For Circuit Identification With Prior Approval. ( Only Labour ) 30.1.4.3 Aluminum Anodized Name Plates For Circuit Identification With Prior Approval. ( Only Composite ) 31.1 Pvc Boardssupply, Installation Of Suitable Size Of Pvc Board Of Approved Make With Necessary Fixing Arrangement Doene By Suitable Screwing On Any Kind Of Surface For Installing Accessories Like Switches, Sockets, Regulators Oe Nay Other Similar Application As Per The Instructions And As Directed By E-I-C, Es 31.1.1 4 X 4 ( Only Supply ) 31.1.2 4 X 4 ( Only Labour ) 31.1.3 4 X 4 ( Composite ) 31.1.4 4 X 6 ( Only Supply ) 31.1.5 4 X 6 ( Only Labour ) 31.1.6 4 X 6 ( Composite ) 31.1.7 4 X 7 ( Only Supply ) 31.1.8 4 X 7 ( Only Labour ) 31.1.9 4 X 7 ( Composite ) 31.1.10 6 X 6 ( Only Supply ) 31.1.11 6 X 6 ( Only Labour ) 31.1.12 6 X 6 ( Composite ) 31.1.13 6 X 8 ( Only Supply ) 31.1.14 6 X 8 ( Only Labour ) 31.1.15 6 X 8 ( Composite ) 31.1.16 8 X 10 ( Only Supply ) 31.1.17 8 X 10 ( Only Labour ) 31.1.18 8 X 10 ( Composite ) 31.1.19 10 X 12 ( Only Supply ) 31.1.20 10 X 12 ( Only Labour ) 31.1.21 10 X 12 ( Composite ) 31.1.22 12 X 12 ( Only Supply ) 31.1.23 12 X 12 ( Only Labour ) 31.1.24 12 X 12 ( Composite ) 31.1.25 3.5 X 6 ( Only Supply ) 31.1.26 3.5 X 6 ( Only Labour ) 31.1.27 3.5 X 6 ( Composite ) 31.1.28 3.5 X 8 ( Only Supply ) 31.1.29 3.5 X 8 ( Only Labour ) 31.1.30 3.5 X 8 ( Composite ) 31.1.31 3.5 X 10 ( Only Supply ) 31.1.32 3.5 X 10 ( Only Labour ) 31.1.33 3.5 X 10 ( Composite ) 31.1.34 3.5 X 12 ( Only Supply ) 31.1.35 3.5 X 12 ( Only Labour ) 31.1.36 3.5 X 12 ( Composite ) 32 Mcbs / Mccbs / Sfus / Isolators 32.1 Supply, Fixing, Testing & Commissioning Of Mccb Of Reputed Make With Metal Enclosure Box & Lsi Protection , 35 Ka Phase Seperator , And Fixing Accessories Connected With Provided Leads On Incoming & Outgoing Side Duly With Necessary Fixing Arrangement Etc Completed In An Approved Manner, All As Per Instructions And As Directed By E-I-C, Es. 32.1.1. As Per Item No 32.1 For– 32 A ( Only Supply ) 32.1.2 As Per Item No 32.1 For– 32 A ( Only Labour ) 32.1.3. As Per Item No 32.1 For– 32 A ( Composite ) 32.1.4 As Per Item No 32.1 But For– 63 A ( Only Supply ) 32.1.5. As Per Item No 32.1 But For– 63 A ( Only Labour ) 32.1.6 As Per Item No 32.1 But For– 63 A ( Composite ) 32.1.7. As Per Item No 32.1 But For– 100 A ( Only Supply ) 32.1.8 As Per Item No 32.1 But For– 100 A ( Only Labour ) 32.1.9 As Per Item No 32.1 But For– 100 A ( Composite ) 32.1.10 As Per Item No 32.1 But For– 200 A ( Only Supply ) 32.1.11. As Per Item No 32.1 But For– 200 A ( Only Labour ) 32.1.12 As Per Item No 32.1 But For– 200 A ( Composite ) 32.1.13 As Per Item No 32.1 But For 250 A ( Only Supply ) 32.1.14 As Per Item No 32.1 But For 250 A ( Only Labour ) 32.1.15 As Per Item No 32.1 But For 250 A ( Composite ) 32.1.16 As Per Item No 32.1 But For 400 A ( Only Supply ) 32.1.17 As Per Item No 32.1 But For 400 A ( Only Labour ) 32.1.18 As Per Item No 32.1 But For 400 A ( Composite ) 32.1.19 As Per Item No 32.1 But For 630 A ( Only Supply ) 32.1.20 As Per Item No 32.1 But For 630 A ( Only Labour ) 32.1.21 As Per Item No 32.1 But For 630 A ( Composite ) 32.2 Supply, Fixing, Testing & Commissioning Of C Curve Mcb With Enclosure & Connected With Provided Leads On Incoming & Outgoing Side With All Fixing Arrangemet Etc Duly Completed Approved Manner, All As Per Instruction And As Directed By E-I-C, Es. 32.2.1 As Per Item No 32.2 For– 6 A Sp ( Only Supply ) 32.2.2 As Per Item No 32.2 For– 6 A Sp ( Only Labour ) 32.2.3 As Per Item No 32.2 For– 6 A Sp ( Composite ) 32.2.4 As Per Item No 32.2 But For– 16 A Sp ( Only Supply ) 32.2.5 As Per Item No 32.2 But For– 16 A Sp ( Only Labour ) 32.2.6 As Per Item No 32.2 But For– 16 A Sp ( Composite ) 32.2.7 As Per Item No 32.2 But For– 20 A Sp ( Only Supply ) 32.2.8 As Per Item No 32.2 But For– 20 A Sp ( Only Labour ) 32.2.9 As Per Item No 32.2 But For– 20 A Sp ( Composite ) 32.2.10 As Per Item No 32.2 But For– 32 A Sp ( Only Supply ) 32.2.11 As Per Item No 32.2 But For– 32 A Sp ( Only Labour ) 32.2.12 As Per Item No 32.2 But For– 32 A Sp ( Composite ) 32.2.13 As Per Item No 32.2 But For– 20 A Dp ( Only Supply ) 32.2.14 As Per Item No 32.2 But For– 20 A Dp ( Only Labour ) 32.2.15 As Per Item No 32.2 But For– 20 A Dp ( Composite ) 32.2.16 As Per Item No 32.2 But For– 32 A Dp ( Only Supply ) 32.2.17 As Per Item No 32.2 But For– 32 A Dp ( Only Labour ) 32.2.18 As Per Item No 32.2 But For– 32 A Dp ( Composite ) 32.2.19 As Per Item No 32.2 But For– 40 A Dp ( Only Supply ) 32.2.20 As Per Item No 32.2 But For– 40 A Dp ( Only Labour ) 32.2.21 As Per Item No 32.2 But For– 40 A Dp ( Composite ) 32.2.22 As Per Item No 32.2 But For– 63 A Dp ( Only Supply ) 32.2.23 As Per Item No 32.2 But For– 63 A Dp ( Only Labour ) 32.2.24 As Per Item No 32.2 But For– 63 A Dp ( Composite ) 32.2.25 As Per Item No 32.2 But For– 32 A Tp ( Only Supply ) 32.2.26 As Per Item No 32.2 But For– 32 A Tp ( Only Labour ) 32.2.27 As Per Item No 32.2 But For– 32 A Tp ( Composite ) 32.2.28 As Per Item No 32.2 But For– 40 A Tp ( Only Supply ) 32.2.29 As Per Item No 32.2 But For– 40 A Tp ( Only Labour ) 32.2.30 As Per Item No 32.2 But For– 40 A Tp ( Composite ) 32.2.31 All As Per Item No 30.1 For -63 A Tp ( Only Supply ) 32.2.32 As Per Item No 32.2 But For– 63 A Tp ( Only Labour ) 32.2.33 As Per Item No 32.2 But For– 63 A Tp ( Composite ) 32.2.34 As Per Item No 32.2 But For32 A, 4 Pole ( Only Supply ) 32.2.35 As Per Item No 32.2 But For32 A, 4 Pole ( Only Labour ) 32.2.36 As Per Item No 32.2 But For32 A, 4 Pole ( Composite ) 32.2.37 As Per Item No 32.2 But For40 A, 4 Pole ( Only Supply ) 32.2.38 As Per Item No 32.2 But For40 A, 4 Pole ( Only Labour ) 32.2.39 As Per Item No 32.2 But For40 A, 4 Pole ( Composite ) 32.2.40 As Per Item No 32.2 But For63 A, 4 Pole ( Only Supply ) 32.2.41 As Per Item No 32.2 But For63 A, 4 Pole ( Only Labour ) 32.2.42 As Per Item No 32.2 But For63 A, 4 Pole ( Composite ) 32.2.43 As Per Item No 32.2 But For 100 A, 4 Pole Isolator ( Mcb Type ) ( Only Supply ) 32.2.44 As Per Item No 32.2 But For 100 A, 4 Pole Isolator ( Mcb Type ) ( Only Labour ) 32.2.45 As Per Item No 32.2 But For 100 A, 4 Pole Isolator ( Mcb Type ) ( Composite ) 32.3 Supply, Fixing, Testing & Commissioning Of Tpn Sfu In Sheet Steel Enclosure Of Reputed Make With Suitable Hrc Fuses And To Be Connected With Provided List With All Necessary Fixing Arrangement As As Per Instrructions And As Directed By E-I-C, Es. 32.3.1 32 A, 415 V, Ac ( Only Supply ) 32.3.2 32 A, 415 V, Ac ( Only Labour ) 32.3.3 32 A, 415 V, Ac ( Composite ) 32.3.4 63 A, 415 V, Ac ( Only Supply ) 32.3.5 63 A, 415 V, Ac ( Only Labour ) 32.3.6 63 A, 415 V, Ac ( Composite ) 32.3.7 125 A, 415 V, Ac ( Only Supply ) 32.3.8 125 A, 415 V, Ac ( Only Labour ) 32.3.9 125 A, 415 V, Ac ( Composite ) 32.3.10 200 A, 415 V, Ac ( Only Supply ) 32.3.11 200 A, 415 V, Ac ( Only Labour ) 32.3.12 200 A, 415 V, Ac ( Composite ) 32.3.14 250 A, 415 V, Ac ( Only Labour ) 32.3.15 250 A, 415 V, Ac ( Composite ) 32.3.16 315 A, 415 V, Ac ( Only Supply ) 32.3.17 315 A, 415 V, Ac ( Only Labour ) 32.3.18 315 A, 415 V, Ac ( Composite ) 32.3.19 400 A, 415 V, Ac ( Only Supply ) 32.3.20 400 A, 415 V, Ac ( Only Labour ) 32.3.21 400 A, 415 V, Ac ( Composite ) 32.3.22 630 A, 415 V, Ac ( Only Supply ) 32.3.23 630 A, 415 V, Ac ( Only Labour ) 32.3.24 630 A, 415 V, Ac ( Composite ) 32.4 Supply, Fixing, Testing & Commissioning Of Mccb Of Reputed Make With Metal Enclosure Box Lsi Protection , 35 Ka Phase Seperator , And Fixing Accessories Connected With Provided Leads On Incoming & Outgoing Side Duly With Necessary Fixing Arrangement Etc Completed In An Approved Manner, All As Per Instructions And As Directed By E-I-C, Es. 32.4.1 As Per Item No 32.4 For 1000 A ( Only Supply ) 32.4.2 As Per Item No 32.4 For 1000 A ( Only Labour ) 32.4.3 As Per Item No 32.4 For 1000 A ( Composite ) 32.4.4 As Per Item No 32.4 But For 800 A ( Only Supply ) 32.4.5 As Per Item No 32.4 But For 800 A ( Only Labour ) 32.4.6 As Per Item No 32.4 But For 800 A ( Composite ) 32.5 Providing, Fixing, Testing & Commissioning Of Reputed Make Tpn Isolator With Provided Leads Incoming & Outgoing Side With All Necessary Fixing Arrangement Duly Completed In Approved Manner All As Per Instructions And As Directed By E-I-C, Es. 32.5.1 As Per Item No 32.5 For 400 A ( Only Supply ) 32.5.2 As Per Item No 32.5 For 400 A ( Only Labour ) 32.5.3 As Per Item No 32.5 For 400 A ( Composite ) 32.5.4 As Per Item No 32.5 But For 250 A ( Only Supply ) 32.5.5 As Per Item No 32.5 But For 250 A ( Only Labour ) 32.5.6 As Per Item No 32.5 But For 250 A ( Composite ) 32.5.7 As Per Item No 32.5 But For 125 A ( Only Supply ) 32.5.8 As Per Item No 32.5 But For 125 A ( Only Labour ) 32.5.9 As Per Item No 32.5 But For 125 A ( Composite ) 32.5.10 As Per Item No 32.5 But For 63 A ( Only Supply ) 32.5.11 As Per Item No 32.5 But For 63 A ( Only Labour ) 32.5.12 As Per Item No 32.5 But For 63 A ( Composite ) 32.6 Providing, Fixing, Testing & Commissioning Of Reputed Make Tpn Sfu With Provided Leads On Incoming & Outgoing Side With Fixing Arrangement Duly Completed In Approved Manner All As Per Instructions And As Directed By E-I-C, Es. 32.6.1 As Per Item No 32.6 For 630 A ( Only Supply ) 32.6.2 As Per Item No 32.6 For 630 A ( Only Labour ) 32.6.3 As Per Item No 32.6 For 630 A ( Composite ) 32.6.4 As Per Item No 32.6 But For 400 A ( Only Supply ) 32.6.5 As Per Item No 32.6 But For 400 A ( Only Labour ) 32.6.6 As Per Item No 32.6 But For 400 A ( Composite ) 32.6.7 As Per Item No 32.6 But For 250 A ( Only Supply ) 32.6.8 As Per Item No 32.6 But For 250 A ( Only Labour ) 32.6.9 As Per Item No 32.6 But For 250 A ( Composite ) 32.6.10 As Per Item No 32.6 But For 125 A ( Only Supply ) 32.6.11 As Per Item No 32.6 But For 125 A ( Only Labour ) 32.6.12 As Per Item No 32.6 But For 125 A ( Composite ) 32.6.13 As Per Item No 32.6 But For 200 A ( Only Supply ) 32.6.14 As Per Item No 32.6 But For 200 A ( Only Labour ) 32.6.15 As Per Item No 32.6 But For 200 A ( Composite ) 32.6.16 As Per Item No 32.6 But For 63 A ( Only Supply ) 32.6.17 As Per Item No 32.6 But For 63 A ( Only Labour ) 32.6.18 As Per Item No 32.6 But For 63 A ( Composite ) 32.6.19 As Per Item No 32.6 But For 32 A ( Only Supply ) 32.6.20 As Per Item No 32.6 But For 32 A ( Only Labour ) 32.6.21 As Per Item No 32.6 But For 32 A ( Composite ) 32.7 Providing, Fixing, Testing & Commissioning Of Reputed Make Tpn Mcb With Provided Leads On Incoming & Outgoing Side With Necessary Fixing Arrangement Duly Completed In Approved Manner All Asper Instructions And As Diredtec By E-I-C, Es. 32.7.1 All As Per Item No 32.7 For 63 A ( Only Supply ) 32.7.2 All As Per Item No 32.7 For 63 A ( Only Labour ) 32.7.3 All As Per Item No 32.7 For 63 A ( Composite ) 32.7.4 All As Per Item No 32.7 For 32 A ( Only Supply ) 32.7.5 All As Per Item No 32.7 For 32 A ( Only Labour ) 32.7.6 All As Per Item No 32.7 For 32 A ( Composite ) 32.8 Providing, Fixing, Testing & Commissioning Of Reputed Dp Mcb With Provided Leads On Incoming & Outgoing Side With Fixing Arrangement Duly Completed In Approved Manner All As Per Instructions And As Directed By E-I-C, Es. 32.8.1 All As Per Item No 32.8 For 63 A ( Only Supply ) 32.8.2 All As Per Item No 32.8 For 63 A ( Only Labour ) 32.8.3 All As Per Item No 32.8 For 63 A ( Composite ) 32.8.4 All As Per Item No 32.8 But For 40 A ( Only Supply ) 32.8.5 All As Per Item No 32.8 But For 40 A ( Only Labour ) 32.8.6 All As Per Item No 32.8 But For 40 A ( Composite ) 32.8.7 All As Per Item No 32.8 But For 32 A ( Only Supply ) 32.8.8 All As Per Item No 32.8 But For 32 A ( Only Labour ) 32.8.9 All As Per Item No 32.8 But For 32 A ( Composite ) 32.8.10 All As Per Item No 32.8 But For 20 A ( Only Supply ) 32.8.11 All As Per Item No 32.8 But For 20 A ( Only Labour ) 32.8.12 All As Per Item No 32.8 But For 20 A ( Composite ) 32.8.13 All As Per Item No 32.8 But For 16 A ( Only Supply ) 32.8.14 All As Per Item No 32.8 But For 16 A ( Only Labour ) 32.8.15 All As Per Item No 32.8 But For 16 A ( Composite ) 32.9 Providing, Fixing, Testing & Commissioning Of Reputed Make Dp Elcb With Provided Leads On Incoming & Outgoing Side With Fixing Arrangement Duly Completed In Approved Manner All As Per Instructions And As Directed By E-I-C, Es 32.9.1 All As Per Item No 32.9 For 63 A ( Only Supply ) 32.9.2 All As Per Item No 32.9 For 63 A ( Only Labour ) 32.9.3 All As Per Item No 32.9 For 63 A ( Composite ) 32.9.4 All As Per Item No 32.9 But For 40 A ( Only Supply ) 32.9.5 All As Per Item No 32.9 But For 40 A ( Only Labour ) 32.9.6 All As Per Item No 32.9 But For 40 A ( Composite ) 32.9.7 All As Per Item No 32.9 But For 25 A ( Only Supply ) 32.9.8 All As Per Item No 32.9 But For 25 A ( Only Labour ) 32.9.9 All As Per Item No 32.9 But For 25 A ( Composite ) 32.10.A Providing, Fixing, Testing & Commissioning Of Reputed Make 4 Pole Elcb With Provided Leads On Incoming & Outgoing Side With Fixing Arrangement Duly Completed In Approved Manner As Per Instructions And As Directed By E-I-C, Es. 32.10.1 All As Per Item No 32.10 For 63 A ( Only Supply ) 32.10.2 All As Per Item No 32.10 For 63 A ( Only Labour ) 32.10.3 All As Per Item No 32.10 For 63 A ( Composite ) 32.10.4 All As Per Item No 32.10 But For 40 A ( Only Supply ) 32.10.5 All As Per Item No 32.10 But For 40 A ( Only Labour ) 32.10.6 All As Per Item No 32.10 But For 40 A ( Composite ) 32.11 Providing, Fixing, Testing & Commissioning Of Reputed Make Sp Mcb With Provided Leads On Incoming & Outgoing Side With Fixing Arrangementduly Completed In Approved Manner All As Per Instructions And As Directed By E-I-C, Es. 32.11.1 All As Per Item No 32.11 For 40 / 63A ( Only Supply ) 32.11.2 All As Per Item No 32.11 For 40 / 63A ( Only Labour ) 32.11.3 All As Per Item No 32.11 For 40 / 63A ( Composite ) 32.11.4 All As Per Item No 32.11 But For 32 A ( Only Supply ) 32.11.5 All As Per Item No 32.11 But For 32 A ( Only Labour ) 32.11.6 All As Per Item No 32.11 But For 32 A ( Composite ) 32.11.7 All As Per Item No 32.11 But For 20 A ( Only Supply ) 32.11.8 All As Per Item No 32.11 But For 20 A ( Only Labour ) 32.11.9 All As Per Item No 32.11 But For 20 A ( Composite ) 32.11.10 All As Per Item No 32.11 But For 16 A ( Only Supply ) 32.11.11 All As Per Item No 32.11 But For 16 A ( Only Labour ) 32.11.12 All As Per Item No 32.11 But For 16 A ( Composite ) 32.11.13 All As Per Item No 32.11 But For 6 A ( Only Supply ) 32.11.14 All As Per Item No 32.11 But For 6 A ( Only Labour ) 32.11.15 All As Per Item No 32.11 But For 6 A ( Composite ) 32.12 Providing, Fixing, Testing & Commissioning Of Reputed Make Tpn Mcb+Elcb With Provided Leads On Incoming & Outgoing Side With Necessary Fixing Arrangement Duly Completed In Approved Manner As Per Instructions And As Directed By E-I-C, Es 32.12.1 All As Per Item No 32.12 For 32 A ( Only Supply ) 33.1 Ct / Pt And Other Panel Componentsproviding, Fixing, Testing & Commissioning Of Reputed Make Ct With Provided Bus Bar On Incoming & Leads On Outgoing Side Duly Completed In Approved Manner. Class-1, 15 Va, Resin Cast, Bar Primary Type. 33.2 Supply, Fixing, Testing And Commissioning Of Various Sizes Of Annunciator Panel As Mentioned Below With Test, Accepts, Reset Push Button, Supply On Indication With Necessary Fixing Arrangement, All As Per Instructions And As Directed By E-I-C, Es. ( Prior Approval Is Required ) 33.3 Providing 33 Kv Resin Cast Type Pt For 33 Kv Panel. Ratio- 33Kv / 22 Kv / Root3 / 110 / Root3 / 110 / Root3, Burden 100Va / 50 Va, Class 1 / 3P, H.S.V-36 Kv, Insulation -75 / 170 Kvp ( Only Supply ) 33.3.1 Providing 33 Kv Resin Cast Type Pt For 33 Kv Panel. Ratio- 33Kv / 22 Kv / Root3 / 110 / Root3 / 110 / Root3, Burden 100Va / 50 Va, Class 1 / 3P, H.S.V-36 Kv, Insulation -75 / 170 Kvp ( Only Labour ) 33.3.2 Providing 33 Kv Resin Cast Type Pt For 33 Kv Panel. Ratio- 33Kv / 22 Kv / Root3 / 110Root3 / 110 / Root3, Burden 100Va / 50 Va, Class 1 / 3P, H.S.V-36 Kv, Insulation -75 / 170 Kvp ( Composite ) 33.4 Providing 11 Kv Resin Cast Type Pt For 11 Kv Panel. Ratio-11 Kv / Root3 / 110 / Root3, Burden 100 Va, Class 1, H.S.V-12 Kv Insulation Level 28 / 75 Kvp ( Only Supply ) 33.4.1 Providing 11 Kv Resin Cast Type Pt For 11 Kv Panel. Ratio-11 Kv / Root3 / 110 / Root3, Burden 100 Va, Class 1, H.S.V-12 Kv Insulation Level 28 / 75 Kvp ( Only Labour ) 33.4.2 Providing 11 Kv Resin Cast Type Pt For 11 Kv Panel. Ratio-11 Kv / Root3 / 110 / Root3, Burden 100 Va, Class 1, H.S.V-12 Kv Insulation Level 28 / 75 Kvp ( Only Composite ) 33.5 Providing 33 Kv Resin Cast Type Ct For 33 Kv Panel. Ratio- 200 / 5-5-5 Amps.Burdun 15 Va, Class 1-5P10-Ps, H.S.V-36 Kv, Insulation Level 75 / 170 Kvp. ( Only Supply ) 33.5.1 Providing 33 Kv Resin Cast Type Ct For 33 Kv Panel. Ratio- 200 / 5-5-5 Amps.Burdun 15 Va, Class 1-5P10-Ps, H.S.V-36 Kv, Insulation Level 75 / 170 Kvp. ( Only Labour ) 33.5.2 Providing 33 Kv Resin Cast Type Ct For 33 Kv Panel. Ratio- 200 / 5-5-5 Amps.Burdun 15 Va, Class 1-5P10-Ps, H.S.V-36 Kv, Insulation Level 75 / 170 Kvp. ( Composite ) 33.6 Providing 33 Kv Resin Cast Type Ct For 33 Kv Panel. Ratio- 200 / 5-5 Amps.Burdun 15 Va, Class 1-5P10, H.S.V-36 Kv, Insulation Level 75 / 170 Kvp. ( Only Supply ) 33.6.1 Providing 33 Kv Resin Cast Type Ct For 33 Kv Panel. Ratio- 200 / 5-5 Amps.Burdun 15 Va, Class 1-5P10, H.S.V-36 Kv, Insulation Level 75 / 170 Kvp. ( Only Labour ) 33.6.2 Providing 33 Kv Resin Cast Type Ct For 33 Kv Panel. Ratio- 200 / 5-5 Amps.Burdun 15 Va, Class 1-5P10, H.S.V-36 Kv, Insulation Level 75 / 170 Kvp. ( Composite ) 33.7 Providing 11 Kv Resin Cast Ct For 11 Kv Panel.Ratio-600-300 / 5-5-5.Burdun 15 Va, Class 1-5P10-Ps, H.S.V-12 Kv, Insulation Level 28 / 75 Kvp ( Only Supply ) 33.7.1 Providing 11 Kv Resin Cast Ct For 11 Kv Panel.Ratio-600-300 / 5-5-5.Burdun 15 Va, Class 1-5P10-Ps, H.S.V-12 Kv, Insulation Level 28 / 75 Kvp ( Only Labour ) 33.7.2 Providing 11 Kv Resin Cast Ct For 11 Kv Panel.Ratio-600-300 / 5-5-5.Burdun 15 Va, Class 1-5P10-Ps, H.S.V-12 Kv, Insulation Level 28 / 75 Kvp ( Composite ) 33.8 Providing 11 Kv Resin Cast Ct For 11 Kv Panel.Ratio-600-300 / 5-5.Burdun 15 Va, Class Ps, H.S.V-12 Kv, Insulation Level 28 / 75 Kvp ( Only Supply ) 33.8.1 Providing 11 Kv Resin Cast Ct For 11 Kv Panel.Ratio-600-300 / 5-5.Burdun 15 Va, Class Ps, H.S.V-12 Kv, Insulation Level 28 / 75 Kvp ( Only Labour ) 33.8.2 Providing 11 Kv Resin Cast Ct For 11 Kv Panel.Ratio-600-300 / 5-5.Burdun 15 Va, Class Ps, H.S.V-12 Kv, Insulation Level 28 / 75 Kvp ( Composite ) 33.9 Providing 33Kv, 3 Amps, Eshwari Or Equivalent Make Ht Pt Fuse ( Only Supply ) 33.9.1 Providing 33Kv, 3 Amps, Eshwari Or Equivalent Make Ht Pt Fuse ( Only Labour ) 33.9.2 Providing 33Kv, 3 Amps, Eshwari Or Equivalent Make Ht Pt Fuse ( Composite ) 33.10.A Providing 11Kv, 3 Amps, Eshwari Or Equivalent Make Ht Pt Fuse ( Only Supply ) 33.10.1 Providing 11Kv, 3 Amps, Eshwari Or Equivalent Make Ht Pt Fuse ( Only Labour ) 33.10.2 Providing 11Kv, 3 Amps, Eshwari Or Equivalent Make Ht Pt Fuse ( Composite ) 34.1 Panel Accessories Providing, Fixing, Testing & Commissioning Of Ammeter 144 X 144 Mm Size, 240 Deg. Scale Taught Band Type For Various Ct Ratings. ( Only Supply ) 34.1.1 Providing, Fixing, Testing & Commissioning Of Ammeter 144 X 144 Mm Size, 240 Deg. Scale Taught Band Type For Various Ct Ratings. ( Only Labour ) 34.1.2 Providing, Fixing, Testing & Commissioning Of Ammeter 144 X 144 Mm Size, 240 Deg. Scale Taught Band Type For Various Ct Ratings. ( Composite ) 34.2.0 Providing, Fixing, Testing & Commissioning Of Ammeter 144 X 144 Mm Size, 90 Deg. Scale Mi Type For Various Ct Ratings. ( Only Supply ) 34.2.1 Providing, Fixing, Testing & Commissioning Of Ammeter 144 X 144 Mm Size, 90 Deg. Scale Mi Type For Various Ct Ratings. ( Only Labour ) 34.2.2 Providing, Fixing, Testing & Commissioning Of Ammeter 144 X 144 Mm Size, 90 Deg.Scale Mi Type For Various Ct Ratings. ( Composite ) 34.2.3 Providing, Fixing, Testing & Commissioning Of Ammeter 96 X 96 Mm Size, 90 Deg.Scale Mi Type For Various Ct Ratings. ( Item No. 8. ) ( Only Supply ) 34.2.4 Providing, Fixing, Testing & Commissioning Of Ammeter 96 X 96 Mm Size, 90 Deg.Scale Mi Type For Various Ct Ratings. ( Item No. 8. ) ( Only Labour ) 34.2.5 Providing, Fixing, Testing & Commissioning Of Ammeter 96 X 96 Mm Size, 90 Deg.Scale Mi Type For Various Ct Ratings. ( Item No. 8. ) ( Composite ) 34.2.6 Providing, Fixing, Testing & Commissioning Of Voltmeter 96 X 96 Mm Size, 90 Deg.Scale Mi Type For Various Ct Ratings. ( Item No. 8. ) ( Only Supply ) 34.2.7 Providing, Fixing, Testing & Commissioning Of Voltmeter 96 X 96 Mm Size, 90 Deg.Scale Mi Type For Various Ct Ratings. ( Item No. 8. ) ( Only Labour ) 34.2.8 Providing, Fixing, Testing & Commissioning Of Voltmeter 96 X 96 Mm Size, 90 Deg.Scale Mi Type For Various Ct Ratings. ( Item No. 8. ) ( Composite ) 34.3.A Providing, Fixing, Testing & Commissioning Of Pt, 415 / 110 V ( 10 Va ) ( Only Supply ) 34.3.1 Providing, Fixing, Testing & Commissioning Of Pt, 415 / 110 V ( 10 Va ) ( Only Labour ) 34.3.2 Providing, Fixing, Testing & Commissioning Of Pt, 415 / 110 V ( 10 Va ) ( Composite ) 34.4 Providing, Fixing, Testing & Commissioning Of Voltmeter 0 – 500 V, 144 X 144 Mm Size, 240 Deg. Scale Taught Band Type For Variousct Ratings. ( Item No. 8. ) ( Only Supply ) 34.4.1 Providing, Fixing, Testing & Commissioning Of Voltmeter 0 – 500 V, 144 X 144 Mm Size, 240 Deg. Scale Taught Band Type For Variousct Ratings. ( Item No. 8. ) ( Only Labour ) 34.4.2 Providing, Fixing, Testing & Commissioning Of Voltmeter 0 – 500 V, 144 X 144 Mm Size, 240 Deg. Scale Taught Band Type For Variousct Ratings. ( Item No. 8. ) ( Composite ) 34.5 Providing, Fixing, Testing & Commissioning Of Voltmeter 0 – 500 V, 144 X 144 Mm Size, 90 Deg. Scale Mi Type For Above Said Ct Ratings. ( Item No. 8. ) ( Only Supply ) 34.5.1 Providing, Fixing, Testing & Commissioning Of Voltmeter 0 – 500 V, 144 X 144 Mm Size, 90 Deg.Scale Mi Type For Above Said Ct Ratings. ( Item No. 8. ) ( Only Labour ) 34.5.2 Providing, Fixing, Testing & Commissioning Of Voltmeter 0 – 500 V, 144 X 144 Mm Size, 90 Deg. Scale Mi Type For Above Said Ct Ratings. ( Item No. 8. ) ( Composite ) 34.6 Providing, Fixing, Testing & Commissioning Of Kwh+Mdi 3 Phase 4 Wires. ( Only Supply ) 34.6.1 Providing, Fixing, Testing & Commissioning Of Kwh+Mdi 3 Phase 4 Wires. ( Only Labour ) 34.6.2 Providing, Fixing, Testing & Commissioning Of Kwh+Mdi 3 Phase 4 Wires. ( Composite ) 34.6.3 Providing, Fixing, Testing & Commissioning Of Single Phase Direct Reading Digital Kwh Meter Suitable Up To 40Amps. ( Only Supply ) 34.6.4 Providing, Fixing, Testing & Commissioning Of Single Phase Direct Reading Digital Kwh Meter Suitable Up To 40Amps.. ( Only Labour ) 34.6.5 Providing, Fixing, Testing & Commissioning Of Single Phase Direct Reading Digital Kwh Meter Suitable Up To 40Amps. ( Composite ) 34.6.6 Providing, Fixing, Testing & Commissioning Of Three Phase Direct Reading Digital Kwh Meter Suitable Up To 40Amps. ( Only Supply ) 34.6.7 Providing, Fixing, Testing & Commissioning Of Single Phase Direct Reading Digital Kwh Meter Suitable Up To 40Amps ( Only Labour ) 34.6.8 Providing, Fixing, Testing & Commissioning Of Single Phase Direct Reading Digital Kwh Meter Suitable Up To 40Amps ( Composite ) 34.7 Providing, Fixing, Testing & Commissioning Of Digital Pf Meter, Inclusivre Of Auxilaries ( Only Supply ) 34.7.1 Providing, Fixing, Testing & Commissioning Of Digital Pf Meter, Inclusivre Of Auxilaries ( Only Labour ) 34.7.2 Providing, Fixing, Testing & Commissioning Of Digital Pf Meter, Inclusivre Of Auxilaries ( Composite ) 34.8 Providing, Fixing, Testing & Commissioning Of Analog Pf Meter ( Only Supply ) 34.8.1 Providing, Fixing, Testing & Commissioning Of Analog Pf Meter ( Only Labour ) 34.8.2 Providing, Fixing, Testing & Commissioning Of Analog Pf Meter ( Composite ) 34.9 Providing, Fixing, Testing & Commissioning Of Frequency Meter, Inclusive Of Auxiluries If Any ( Only Supply ) 34.9.1 Providing, Fixing, Testing & Commissioning Of Frequency Meter, Inclusive Of Auxiluries If Any ( Only Labour ) 34.9.2 Providing, Fixing, Testing & Commissioning Of Frequency Meter, Inclusive Of Auxiluries If Any ( Composite ) 34.10.A Providing, Fixing, Testing & Commissioning Of Selector Switch For Ammeter & Voltmeter ( Only Supply ) 34.10.1 Providing, Fixing, Testing & Commissioning Of Selector Switch For Ammeter & Voltmeter ( Only Labour ) 34.10.2 Providing, Fixing, Testing & Commissioning Of Selector Switch For Ammeter & Voltmeter ( Composite ) 34.11 Providing, Fixing, Testing & Commissioning Of Breaker Selector Switch. 10 A, 3 Pole, 3 Way With Off Type Srp 139 C ( Only Supply ) 34.11.1 Providing, Fixing, Testing & Commissioning Of Breaker Selector Switch. 10 A, 3 Pole, 3 Way With Off Type Srp 139 C ( Only Labour ) 34.11.2 Providing, Fixing, Testing & Commissioning Of Breaker Selector Switch. 10 A, 3 Pole, 3 Way With Off Type Srp 139 C ( Composite ) 34.12 Providing, Fixing, Testing & Commissioning Of Make Breaker Control Switch. ( Tnc Switch ) ( Only Supply ) 34.12.1 Providing, Fixing, Testing & Commissioning Of Make Breaker Control Switch. ( Tnc Switch ) ( Only Labour ) 34.12.2 Providing, Fixing, Testing & Commissioning Of Make Breaker Control Switch. ( Tnc Switch ) ( Composite ) 34.13 Providing, Fixing, Testing & Commissioning Of Auto / Mannual Selector Switch ( Only Supply ) 34.13.1 Providing, Fixing, Testing & Commissioning Of Auto / Mannual Selector Switch ( Only Labour ) 34.13.2 Providing, Fixing, Testing & Commissioning Of Auto / Mannual Selector Switch ( Only Composite ) 34.14 Providing, Fixing, Testing & Commissioning Of 2P2w Rotary Switch ( Only Supply ) 34.14.1 Providing, Fixing, Testing & Commissioning Of 2P2w Rotary Switch ( Only Labour ) 34.14.2 Providing, Fixing, Testing & Commissioning Of 2P2w Rotary Switch ( Composite ) 34.15 Providing, Fixing, Testing & Commissioning Of 3P3w Rotary Switch ( Only Supply ) 34.15.1 Providing, Fixing, Testing & Commissioning Of 3P3w Rotary Switch ( Only Labour ) 34.15.2 Providing, Fixing, Testing & Commissioning Of 3P3w Rotary Switch ( Composite ) 34.16 Providing, Fixing, Testing & Commissioning Of 1 Way Toggle Switch ( Only Supply ) 34.16.1 Providing, Fixing, Testing & Commissioning Of 1 Way Toggle Switch ( Only Labour ) 34.16.2 Providing, Fixing, Testing & Commissioning Of 1 Way Toggle Switch ( Composite ) 34.17 Providing, Fixing, Testing & Commissioning Of 2 Way Toggle Switch ( Only Supply ) 34.17.1 Providing, Fixing, Testing & Commissioning Of 2 Way Toggle Switch ( Only Labour ) 34.17.2 Providing, Fixing, Testing & Commissioning Of 2 Way Toggle Switch ( Composite ) 34.18 Providing, Fixing, Testing & Commissioning Of Indicating Lamp, 48 V Dc. ( Only Supply ) 34.18.1 Providing, Fixing, Testing & Commissioning Of Indicating Lamp, 48 V Dc. ( Only Labour ) 34.18.2 Providing, Fixing, Testing & Commissioning Of Indicating Lamp, 48 V Dc. ( Composite ) 34.19 Providing, Fixing, Testing & Commissioning Of Indicating Lamp, 24 V Dc. ( Only Supply ) 34.19.1 Providing, Fixing, Testing & Commissioning Of Indicating Lamp, 24 V Dc. ( Only Labour ) 34.19.2 Providing, Fixing, Testing & Commissioning Of Indicating Lamp, 24 V Dc. ( Composite ) 34.2 Providing, Fixing, Testing & Commissioning Of Indicating Lamp, 230 V Ac ( Only Supply ) 34.20.1 Providing, Fixing, Testing & Commissioning Of Indicating Lamp, 230 V Ac ( Only Labour ) 34.20.2 Providing, Fixing, Testing & Commissioning Of Indicating Lamp, 230 V Ac ( Composite ) 34.21 Providing, Fixing, Testing & Commissioning Of Indicating Lamp, Led Type. 34.21.1 For Red, Orange, Yellow, Off-White, Green Coloured Led Lamp ( Only Supply ) 34.21.2 For Red, Orange, Yellow, Off-White, Green Coloured Led Lamp ( Composite ) 34.21.3 For Red, Orange, Yellow, Off-White, Green Coloured Led Lamp ( Composite ) 34.21.4 As Per Item No 34.21 But For Blue Coluored Led Lamp ( Only Supply ) 34.21.5 As Per Item No 34.21 But For Blue Coluored Led Lamp ( Only Labour ) 34.21.6 As Per Item No 34.21 But For Blue Coluored Led Lamp ( Composite ) 34.21.7 Providing And Fixing Of Centrifugal Switch ( Only Supply ) 34.21.8 Providing And Fixing Of Centrifugal Switch ( Only Labour ) 34.21.9 Providing And Fixing Of Centrifugal Switch ( Composite ) 34.22 Providing, Fixing, Testing & Commissioning Of Push Buttons ( Only Supply ) 34.22.1 Providing, Fixing, Testing & Commissioning Of Push Buttons ( Only Labour ) 34.22.2 Providing, Fixing, Testing & Commissioning Of Push Buttons ( Composite ) 34.23 Providing, Fixing, Testing & Commissioning Of Luminous Type Push Button White Colour With Bulb. ( Only Supply ) 34.23.1 Providing, Fixing, Testing & Commissioning Of Luminous Type Push Button White Colour With Bulb. ( Only Labour ) 34.23.2 Providing, Fixing, Testing & Commissioning Of Luminous Type Push Button White Colour With Bulb. ( Composite ) 34.24 Providing, Fixing, Testing & Commissioning Of Auxilary Contactor With 2No + 2Nc Auxiliary Contacts Suitable For 230 V Ac. ( Only Supply ) 34.24.1 Providing, Fixing, Testing & Commissioning Of Auxilary Contactor With 2No + 2Nc Auxiliary Contacts Suitable For 230V Ac. ( Only Labour ) 34.24.2 Providing, Fixing, Testing & Commissioning Of Auxilary Contactor With 2No + 2Nc Auxiliary Contacts Suitable For 230V Ac. ( Composite ) 34.24.3 Providing, Fixing, Testing & Commissioning Of Auxilary Contactor With 2No + 2Nc Auxiliary Contacts Suitable For 24 / 48 V Dc. ( Only Supply ) 34.24.4 Providing, Fixing, Testing & Commissioning Of Auxilary Contactor With 2No + 2Nc Auxiliary Contacts Suitable For 24 / 48 V Dc. ( Only Labour ) 34.24.5 Providing, Fixing, Testing & Commissioning Of Auxilary Contactor With 2No + 2Nc Auxiliary Contacts Suitable For 24 / 48 V Dc. ( Composite ) 34.24.6 Providing, Fixing, Testing & Commissioning Of Add On Auxilary Contact Block With 1No + 1Nc ( Only Supply ) 34.24.7 Providing, Fixing, Testing & Commissioning Of Add On Auxilary Contact Block With 1No + 1Nc ( Only Labour ) 34.24.8 Providing, Fixing, Testing & Commissioning Of Add On Auxilary Contact Block With 1No + 1Nc ( Composite ) 34.25 Providing, Fixing, Testing & Commissioning Of Auxilary Contactor With 4No + 4Nc Auxiliary Contacts. ( Only Supply ) 34.25.1 Providing, Fixing, Testing & Commissioning Of Auxilary Contactor With 4No + 4Nc Auxiliary Contacts. ( Only Labour ) 34.25.2 Providing, Fixing, Testing & Commissioning Of Auxilary Contactor With 4No + 4Nc Auxiliary Contacts. ( Composite ) 34.26 Providing, Fixing, Testing & Commissioning Of Auxilary Relay Suitable For 24 / 48 Volts. ( Only Supply ) 34.26.1 Providing, Fixing, Testing & Commissioning Of Auxilary Relay Suitable For 24 / 48 Volts. ( Only Labour ) 34.26.2 Providing, Fixing, Testing & Commissioning Of Auxilary Relay Suitable For 24 / 48 Volts. ( Composite ) 34.27 Providing, Fixing, Testing & Commissioning Of Auxilary Relay Suitable For 24 / 48 Volts. ( Only Supply ) 34.27.1 Providing, Fixing, Testing & Commissioning Of Auxilary Relay Suitable For 24 / 48 Volts. ( Only Labour ) 34.27.2 Providing, Fixing, Testing & Commissioning Of Auxilary Relay Suitable For 24 / 48 Volts. ( Composite ) 34.28 Providing, Fixing, Testing & Commissioning Of Space Heater Of Strip Type 60 W, 240 V Ac ( Only Supply ) 34.28.1 Providing, Fixing, Testing & Commissioning Of Space Heater Of Strip Type 60 W, 240 V Ac ( Only Labour ) 34.28.2 Providing, Fixing, Testing & Commissioning Of Space Heater Of Strip Type 60 W, 240 V Ac ( Composite ) 34.29 Thermo Stat For Space Heater 240 V Ac, 30 Deg. To 90 Deg. ( Only Supply ) 34.29.1 Thermo Stat For Space Heater 240 V Ac, 30 Deg. To 90 Deg. ( Only Labour ) 34.29.2 Thermo Stat For Space Heatre 240 V Ac, 30 Deg. To 90 Deg. ( Composite ) 34.30 Supply And Fixing Of 240 V Ac, Hooter Cands Make ( Only Supply ) 34.30.1 Supply And Fixing Of240 V Ac, Hooter Cands Make ( Only Labour ) 34.30.2 Supply And Fixing Of240 V Ac, Hooter Cands Make ( Composite ) 34.31 Providing 33 Kv Resin Cast Type Ct For 33 Kv Panel. Ratio- 600 / 5-5-5 Amps.Burdun 15 Va, Class-1 / 5P10 / Ps, H.S.V-36 Kv, Insulation Level 75 / 170 Kvp. ( Only Supply ) 34.31.1 Providing 33 Kv Resin Cast Type Ct For 33 Kv Panel. Ratio- 200 / 5-5-5 Amps.Burdun 15 Va, Class 1-5P10-Ps, H.S.V-36 Kv, Insulation Level 75 / 170 Kvp. ( Only Labour ) 34.31.2 Providing 33 Kv Resin Cast Type Ct For 33 Kv Panel. Ratio- 200 / 5-5-5 Amps.Burdun 15 Va, Class 1-5P10-Ps, H.S.V-36 Kv, Insulation Level 75 / 170 Kvp. ( Composite ) 34.32 Providing Dc Power Pack With Battery Backup ( Only Supply ) 34.32.1 Providing Dc Power Pack With Battery Backup ( Only Labour ) 34.32.2 Providing Dc Power Pack With Battery Backup ( Composite ) 35 Electrical Accessories Supply, Fixing, Testing And Commissioning Of The Following Electrical Accessories On The Hylam Sheet / Modular Plates / Pvc Board Etc Or As Directed By Wherever Required Including Appropriate Size Of Copper Conductor Of Pvc Wires Interconnection Using Lugs, Insulatin Tape Etc. In Complete Manner As Directed By E-I-C, Es With Prior Approval. Procurement Of These Items Shall Be Done In Accordence With Approved Makes. Approval Shall Be Sought From E-I-C, Es For Other Brand Or Make. In Case Of Reeplacement, Old / Removed Items Shall Be Handed Over To E-I-C, Es As It Is. Agency Has To Supply Material As Per Existing Makes As Site Linke Anchor / Roma Precision Etc. 35.1.1 6 Amp, , Flush Type S / W ( Only Supply ) 35.1.2 6 Amp, , Flush Type S / W ( Only Labour ) 35.1.3 6 Amp, , Flush Type S / W ( Composite ) 35.1.4 6 Amp, , 3 Pin Socket ( Only Supply ) 35.1.5 6 Amp, , 3 Pin Socket ( Only Labour ) 35.1.6 6 Amp, , 3 Pin Socket ( Composite ) 35.1.7 16 Amp, , Switch ( Only Supply ) 35.1.8 16 Amp, , Switch ( Only Labour ) 35.1.9 16 Amp, , Switch ( Composite ) 35.1.10 16 Amp, , 3 Pin Socket ( Only Supply ) 35.1.11 16 Amp, , 3 Pin Socket ( Only Labour ) 35.1.12 16 Amp, , 3 Pin Socket ( Composite ) 35.1.13 16 Amp, , 5 Pin Socket ( Only Supply ) 35.1.14 16 Amp, , 5 Pin Socket ( Only Labour ) 35.1.15 16 Amp, , 5 Pin Socket ( Composite ) 35.1.16 6 Amp, Top ( Only Supply ) 35.1.17 6 Amp, Top ( Only Labour ) 35.1.18 6 Amp, Top ( Composite ) 35.1.19 16 Amp, Top ( Only Supply ) 35.1.20 16 Amp, Top ( Only Labour ) 35.1.21 16 Amp, Top ( Composite ) 35.1.22 6 Amp, Two-Way Switch , Make Precision ( Only Supply ) 35.1.23 6 Amp, Two-Way Switch , Make Precision ( Only Labour ) 35.1.24 6 Amp, Two-Way Switch , Make Precision ( Composite ) 35.1.25 16 Amp Two-Way Switch ( Only Supply ) 35.1.26 16 Amp Two-Way Switch ( Only Labour ) 35.1.27 16 Amp Two-Way Switch ( Composite ) 35.1.28 16 Amp, 5 Pin, Switch Socket Combination Board ( Only Supply ) 35.1.29 16 Amp, 5 Pin, Switch Socket Combination Board ( Only Labour ) 35.1.30 16 Amp, 5 Pin, Switch Socket Combination Board ( Composite ) 35.1.31 2X15a, 5Pin, Switch Socket Combination Board ( Only Supply ) 35.1.32 2X15a, 5Pin, Switch Socket Combination Board ( Only Labour ) 35.1.33 2X15a, 5Pin, Switch Socket Combination Board ( Composite ) 35.1.34 6 Amp, Bell Push ( Only Supply ) , 35.1.35 6 Amp, Bell Push ( Only Labour ) 35.1.36 6 Amp, Bell Push ( Composite ) 35.1.37 Ceiling Rose ( Only Supply ) 35.1.38 Ceiling Rose ( Only Labour ) 35.1.39 Ceiling Rose ( Composite ) 35.1.40 Angle Holder ( Only Supply ) 35.1.41 Angle Holder ( Only Labour ) 35.1.42 Angle Holder ( Composite ) 35.1.43 Batten Holder ( Only Supply ) 35.1.44 Batten Holder ( Only Labour ) 35.1.45 Batten Holder ( Composite ) 35.1.46 Bell With Indication, Reset Push Button ( Only Supply ) 35.1.47 Bell With Indication, Reset Push Button ( Only Labour ) 35.1.48 Bell With Indication, Reset Push Button ( Composite ) 35.1.49 Buzzer Of Any Approved Make ( Only Supply ) 35.1.50 Buzzer Of Any Approved Make ( Only Labour ) 35.1.51 Buzzer Of Any Approved Make ( Composite ) 35.1.52 3 Pin Telephone Socket, ( Only Supply ) 35.1.53 3 Pin Telephone Socket, ( Only Labour ) 35.1.54 3 Pin Telephone Socket, ( Composite ) 35.1.55 Telephone Socket ( Rj – 11 Jack ) ( Only Supply ) 35.1.56 Telephone Socket ( Rj – 11 Jack ) ( Only Labour ) 35.1.57 Telephone Socket ( Rj – 11 Jack ) ( Composite ) 35.1.58 Rj-45 Jack Socket ( Only Supply ) 35.1.59 Rj-45 Jack Socket ( Only Labour ) 35.1.60 Rj-45 Jack Socket ( Composite ) 35.1.61 Rj-11 Pin ( Only Supply ) 35.1.62 Rj-11 Pin ( Only Labour ) 35.1.63 Rj-11 Pin ( Composite ) 35.1.64 Rj-45 Pin ( Only Supply ) 35.1.65 Rj-45 Pin ( Only Labour ) 35.1.66 Rj-45 Pin ( Composite ) 35.1.67 Telephone 3 Pin Plug Top ( Only Supply ) 35.1.68 Telephone 3 Pin Plug Top ( Only Labour ) 35.1.69 Telephone 3 Pin Plug Top ( Composite ) 35.1.70 Tv Socket ( Only Supply ) 35.1.71 Tv Socket ( Only Labour ) 35.1.72 Tv Socket ( Composite ) 35.1.73 Tv Pin ( Male+ Female ) ( Only Supply ) 35.1.74 Tv Pin ( Male+ Female ) ( Only Labour ) 35.1.75 Tv Pin ( Male+ Female ) ( Compositey ) 35.1.76 Tv Connector ( Splitter ) 35.1.77 As Per Item No 35.1.76 For 2 Way ( Only Supply ) 35.1.78 As Per Item No 35.1.76 For 2 Way ( Only Labour ) 35.1.79 As Per Item No 35.1.76 For 2 Way ( Composite ) 35.1.80 As Per Item No 35.1.76 But For 3 Way ( Only Supply ) 35.1.81 As Per Item No 35.1.76 But For 3 Way ( Only Labour ) 35.1.82 As Per Item No 35.1.76 But For 3 Way ( Composite ) 35.1.83 As Per Item No 35.1.76 But For 4 Way ( Only Supply ) 35.1.84 As Per Item No 35.1.76 But For 4 Way ( Only Labour ) 35.1.85 As Per Item No 35.1.76 But For 4 Way ( Composite ) 35.1.86 Tv Cable Gland For Rj-11 ( Only Supply ) 35.1.87 Tv Cable Gland For Rj-11 ( Only Labour ) 35.1.88 Tv Cable Gland For Rj-11 ( Composite ) 35.1.89 Glass Fuse, 2 A / 4A ( Only Supply ) 35.1.90 Glass Fuse, 2 A / 4A ( Only Labour. ) 35.1.91 Glass Fuse, 2 A / 4A ( Composite ) 35.1.92 Glass Fuse 6A / 10 A ( Only Supply ) 35.1.93 Glass Fuse 6A / 10 A ( Only Labour ) 35.1.94 Glass Fuse 6A / 10 A ( Composite ) 35.1.95 250 W, , Ceiling Fan Regulator ( Only Supply ) 35.1.96 250 W, , Ceiling Fan Regulator ( Only Labour ) 35.1.97 250 W, , Ceiling Fan Regulator ( Composite ) 35.1.98 300 W, , Ceiling Fan Regulator ( Only Suppply ) 35.1.99 300 W, , Ceiling Fan Regulator ( Only Labour ) 35.1.100 300 W, , Ceiling Fan Regulator ( Composite ) 35.1.101 750 W, , Ceiling Fan Regulator ( Only Supply ) 35.1.102 750 W, , Ceiling Fan Regulator ( Only Labur ) 35.1.103 750 W, , Ceiling Fan Regulator ( Composite ) 35.1.104 1000 W, , Ceiling Fan Regulator ( Only Supply ) 35.1.105 1000 W, , Ceiling Fan Regulator ( Only Labour ) 35.1.106 1000 W, Ceiling Fan Regulator ( Composite ) 35.1.107 Iron Connector Flat / Round ( Only Supply ) 35.1.108 Iron Connector Flat / Round ( Only Labour ) 35.1.109 Iron Connector Flat / Round ( Composite ) 35.1.110 Industrial Alarm Bell ( Only Supply ) 35.1.111 Industrial Alarm Bell ( Only Labour ) 35.1.112 Industrial Alarm Bell ( Composite ) 35.1.113 25 Amps, Dp Switch Flush Type With Neon Indication. ( Only Supply ) 35.1.114 25 Amps, Dp Switch Flush Type With Neon Indication. ( Only Labour ) 35.1.115 25 Amps, Dp Switch Flush Type With Neon Indication. ( Composite ) 35.1.116 32 Amps, Dp Switch Flush Type With Neon Indication ( Only Supply ) 35.1.117 32 Amps, Dp Switch Flush Type With Neon Indication ( Only Labour ) 35.1.118 32 Amps, Dp Switch Flush Type With Neon Indication ( Composite ) 35.1.119 Glass For Halogen Fittings. ( Only Supply ) 35.1.120 Glass For Halogen Fittings. ( Only Labour ) 35.1.121 Glass For Halogen Fittings. ( Composite ) 35.1.122 Speed Regulator H-70 K Ohm ( Only Supply ) 35.1.123 Speed Regulator H-70 K Ohm ( Only Labour ) 35.1.124 Speed Regulator H-70 K Ohm ( Composite ) 35.1.125 Regulator For Hoods As Per Sample ) ( Only Supply ) 35.1.126 Regulator For Hoods As Per Sample ) ( Only Labour ) 35.1.127 Regulator For Hoods In As Per Sample ) ( Composite ) 35.1.128 16 Amp, Switch With Red Indicator ( Only Supply ) 35.1.129 16 Amp, Switch With Red Indicator ( Only Labour ) 35.1.130 16 Amp, Switch With Red Indicator ( Composite ) 35.1.131 16 Amp, Switch With Red Indicator ( Only Supply ) 35.1.132 16 Amp, Switch With Red Indicator ( Only Labour ) 35.1.133 16 Amp, Switch With Red Indicator ( Composiet ) 35.1.134 Carbon Brush For Mixers Etc. ( All Sizes ) ( Only Supply ) 35.1.135 Carbon Brush For Mixers Etc. ( All Sizes ) ( Only Labour ) 35.1.136 Carbon Brush For Mixers Etc. ( All Sizes ) ( Composite ) 35.1.137 Carbon Brush Used For Special Purpose M / C ( Only Supply ) 35.1.138 Carbon Brush Used For Special Purpose M / C ( Only Labour ) 35.1.139 Carbon Brush Used For Special Purpose M / C ( Composite ) 35.2 Modular Accesseries For Anchor Roma , Legrand , As Per Existing At Site Matching Or Equivalent. General Guidelines Are As Per Item No 35.1 35.2.1 6 Amp, Switch ( Only Supply ) 35.2.2 6 Amp, Switch ( Only Labour ) 35.2.3 6 Amp, Switch ( Composite ) 35.2.4 16 Amp, Switch ( Only Supply ) 35.2.5 16 Amp, Switch ( Only Labour ) 35.2.6 16 Amp, Switch ( Composite ) 35.2.7 6 Amp, Two-Way Switch ( Only Supply ) 35.2.8 6 Amp, Two-Way Switch ( Only Labour ) 35.2.9 6 Amp, Two-Way Switch ( Composite ) 35.2.10 10 / 16 Amp , Two –Way Switch ( Only Supply ) 35.2.11 10 / 16 Amp , Two –Way Switch ( Only Labour ) 35.2.12 10 / 16 Amp , Two –Way Switch ( Composite ) 35.2.13 6 Amp, Socket ( Only Supply ) 35.2.14 6 Amp, Socket ( Only Labour ) 35.2.15 6 Amp, Socket ( Composite ) 35.2.16 16 Amp, 3 Pin Socket ( Only Supply ) 35.2.17 16 Amp, 3 Pin Socket ( Only Labour ) 35.2.18 16 Amp, 3 Pin Socket ( Compoxite ) 35.2.19 16 Amp, 5 Pin Socket ( Only Supply ) 35.2.20 16 Amp, 5 Pin Socket ( Only Labour ) 35.2.21 16 Amp, 5 Pin Socket ( Composite ) 35.2.22 Telephone Socket ( Rj -11 ) ( Only Supply ) 35.2.23 Telephone Socket ( Rj -11 ) ( Only Labour ) 35.2.24 Telephone Socket ( Rj -11 ) ( Composite ) 35.2.25 Fan Dimmer , 400 / 600W ( 0Nly Supply ) 35.2.26 Fan Dimmer, 400 / 600W ( 0Nly Labour ) 35.2.27 Fan Dimmer, 400 / 600W ( Composite ) 35.2.28 1 Way Tv Socket ( Only Supply ) 35.2.29 1 Way Tv Socket ( Only Labour ) 35.2.30 1 Way Tv Socket ( Composite ) 35.2.31 2 Way Tv Socket ( Only Supply ) 35.2.32 2 Way Tv Socket ( Only Labour. ) 35.2.33 2 Way Tv Socket ( Composite ) 35.2.34 6 Amp, Switch With Indicator ( Only Supply ) 35.2.35 6 Amp, Switch With Indicator ( Only Labour ) 35.2.36 6 Amp, Switch With Indicator ( Composite ) 35.2.37 Bell Push ( Only Supply ) 35.2.38 Bell Push ( Only Labour ) 35.2.39 Bell Push ( Composite ) 35.2.40 Fan Dimmer , 1000W ( 0Nly Supply ) 35.2.41 Fan Dimmer, 1000W ( 0Nly Labour ) 35.2.42 Fan Dimmer, 1000W ( Composite ) 35.2.43 Blank Plate ( 0Nly Supply ) 35.2.44 6 To 32A Sp Mcb In Provided Modular Box Including Face Plate Surface / Conealed Type ( 0Nly Supply ) 35.2.45 6 To 32A Sp Mcb In Provided Modular Box Including Face Plate Surface / Conealed Type ( 0Nly Labour ) 35.2.46 6 To 32A Sp Mcb In Provided Modular Box Including Face Plate Surface / Conealed Type ( Composite ) 35.2.47 16 To 32A Dp Mcb With Modular Box Including Face Plate Surface / Conealed Type ( 0Nly Supply ) 35.2.48 16 To 32A Dp Mcb With Modular Box Including Face Plate Surface / Conealed Type ( 0Nly Labour ) 35.2.49 16 To 32A Dp Mcb With Modular Box Including Face Plate Surface / Conealed Type ( Composite ) 35.2.50 Rj-45 Data Socket ( 0Nly Supply ) 35.2.51 Rj-45 Data Socket ( 0Nly Labour ) 35.2.52 Rj-45 Data Socket ( Composite ) 35.3 Surface ( Pvc ) Boxes For Modular Accessories 35.3.1 1 Or 2 Way ( Only Supply ) 35.3.2 1 Or 2 Way ( Only Labour ) 35.3.3 1 Or 2 Way ( Composite ) 35.3.4 3 Way ( Only Supply ) 35.3.5 3 Way ( Only Labour ) 35.3.6 3 Way ( Composite ) 35.3.7 4 Way ( Only Supply ) 35.3.8 4 Way ( Only Labour ) 35.3.9 4 Way ( Composite ) 35.3.10 6 Way ( Only Supply ) 35.3.11 6 Way ( Only Labour ) 35.3.12 6 Way ( Composite ) 35.3.13 8 Way ( Only Supply ) 35.3.14 8 Way ( Only Labour ) 35.3.15 8 Way ( Composite ) 35.3.16 8 Way Vertical / Rectangular ( Only Supply ) 35.3.17 8 Way Vertical / Rectangular ( Only Labour ) 35.3.18 8 Way Vertical / Rectangular ( Composite ) 35.3.19 12 Way ( Only Supply ) 35.3.20 12 Way ( Only Labour ) 35.3.21 12 Way ( Composite ) 35.3.22 16 Way ( Only Supply ) 35.3.23 16 Way ( Only Labour ) 35.3.24 16 Way ( Composite ) 35.3.25 18 Way ( Only Supply ) 35.3.26 18 Way ( Only Labour ) 35.3.27 18 Way ( Composite ) 35.4 Concealed ( Ms ) Boxes For Modular Accessories & General Accessories 35.4.1 1 Or 2 Way ( Only Supply ) 35.4.2 1 Or 2 Way ( Only Labour ) 35.4.3 1 Or 2 Way ( Composite ) 35.4.4 3 Way ( Only Supply ) 35.4.5 3 Way ( Only Labour ) 35.4.6 3 Way ( Composite ) 35.4.7 4 Way ( Only Supply ) 35.4.8 4 Way ( Only Labour ) 35.4.9 4 Way ( Composite ) 35.4.10 6 Way ( Only Supply ) 35.4.11 6 Way ( Only Labour ) 35.4.12 6 Way ( Composite ) 35.4.13 8 Way ( Only Supply ) 35.4.14 8 Way ( Only Labour ) 35.4.15 8 Way ( Composite ) 35.4.16 8 Way Vertical / Rectangular ( Only Supply ) 35.4.17 8 Way Vertical / Rectangular ( Only Labour ) 35.4.18 8 Way Vertical / Rectangular ( Composite ) 35.4.19 12 Way ( Only Supply ) 35.4.20 12 Way ( Only Labour ) 35.4.21 12 Way ( Composite ) 35.4.22 16 Way ( Only Supply ) 35.4.23 16 Way ( Only Labour ) 35.4.24 16 Way ( Composite ) 35.4.25 18 Way ( Only Supply ) 35.4.26 18 Way ( Only Labour ) 35.4.27 18 Way ( Composite ) 35.5 Face Plate For Modular Accessories 35.5.1 1 Way ( Only Supply ) 35.5.2 1 Way ( Only Labour ) 35.5.3 1 Way ( Composite ) 35.5.4 2 Way ( Only Supply ) 35.5.5 2 Way ( Only Labour ) 35.5.6 2 Way ( Composite ) 35.5.7 3 Way ( Only Supply ) 35.5.8 3 Way ( Only Labour ) 35.5.9 3 Way ( Composite ) 35.5.10 4 Way ( Only Supply ) 35.5.11 4 Way ( Only Labour ) 35.5.12 4 Way ( Composite ) 35.5.13 6 Way ( Only Supply ) 35.5.14 6 Way ( Only Labour ) 35.5.15 6 Way ( Composite ) 35.5.16 8 Way ( Only Supply ) 35.5.17 8 Way ( Only Labour ) 35.5.18 8 Way ( Composite ) 35.5.19 8 Way Vertical / Rectangular ( Only Supply ) 35.5.20 8 Way Vertical / Rectangular ( Only Labour ) 35.5.21 8 Way Vertical / Rectangular ( Composite ) 35.5.22 12 Way ( Only Supply ) 35.5.23 12 Way ( Only Labour ) 35.5.24 12 Way ( Composite ) 35.5.25 16 Way With Or With Indicator ( Only Supply ) 35.5.26 16 Way With Or With Indicator ( Only Labour ) 35.5.27 16 Way With Or With Indicator ( Composite ) 35.5.28 18 Way ( Only Supply ) 35.5.29 18 Way ( Only Labour ) 35.5.30 18 Way ( Composite ) 35.5.31 Cord Less Bell ( Only Supply ) 35.6 Mcb Fixing Channel ( Only Supply ) 35.6.1 Mcb Fixing Channel ( Only Labour ) 35.6.2 Mcb Fixing Channel ( Composite ) 35.7 Connector Fixing Channel ( Cst Channel ) ( Only Supply ) 35.7.1 Connector Fixing Channel ( Cst Channel ) ( Only Labour ) 35.7.2 Connector Fixing Channel ( Cst Channel ) ( Composite ) 35.8 Ht Electrical Tape ( Strippex ) , 25 Mm X .76 Mm X 9.1 M , One Roll, Make Stanvac ( Only Supply ) 35.9 Supply / Fixing Of Assorted Accessories 35.9.1 6 Amps, 3 Pin Multi Plug Connector ( Only Supply ) 35.9.2 6 Amps, 3 Pin Multi Plug Connector ( Only Labour ) 35.9.3 6 Amps, 3 Pin Multi Plug Connector ( Composite ) 35.9.4 16 Amps, Multi Plug Connector ( Only Supply ) 35.9.5 16 Amps, Multi Plug Connector ( Only Labour ) 35.9.6 16 Amps, Multi Plug Connector ( Composote ) 35.9.7 6A, Supper Adaptor Pearl ( Only Supply ) 35.9.8 6A, Supper Adaptor Pearl ( Only Labour ) 35.9.9 6A, Supper Adaptor Pearl ( Composite ) 35.9.10 1 Way Bed Switch ( Only Supply ) 35.9.11 1 Way Bed Switch ( Only Labour ) 35.9.12 1 Way Bed Switch ( Composite ) 35.9.13 Adaptor ( Only Supply ) 35.9.14 Adaptor ( Only Labour ) 35.9.15 Adaptor ( Composite ) 35.9.16 3 Pin Flexi Cord 6 A, ( Extension Board ) ( Only Supply ) 35.9.17 16 A, Flexi Cord, ( Extension Board ) ( Only Supply ) 35.10.A Supply / Fixing Of Various Gang Boxes: 35.10.1 1 Way ( Only Supply ) 35.10.2 1 Way ( Only Labour ) 35.10.3 1 Way ( Composite ) 35.10.4 2 Way ( Only Supply ) 35.10.5 2 Way ( Only Labour ) 35.10.6 2 Way ( Composite ) 35.10.7 3 Way ( Only Supply ) 35.10.8 3 Way ( Only Labour ) 35.10.9 3 Way ( Composite ) 35.10.10 4 Way ( Only Supply ) 35.10.11 4 Way ( Only Labour ) 35.10.12 4 Way ( Composite ) 35.10.13 5 Way ( Only Supply ) 35.10.14 5 Way ( Only Labour ) 35.10.15 5 Way ( Composite ) 35.11 Supply / Fixing Of Various Domestic Gang Boxes: 35.11.1 1 Way ( Only Supply ) 35.11.2 1 Way ( Only Labour ) 35.11.3 1 Way ( Composite ) 35.11.4 2 Way ( Only Supply ) 35.11.5 2 Way ( Only Labour ) 35.11.6 2 Way ( Composite ) 35.11.7 3 Way ( Only Supply ) 35.11.8 3 Way ( Only Labour ) 35.11.9 3 Way ( Composite ) 35.11.10 4 Way ( Only Supply ) 35.11.11 4 Way ( Only Labour ) 35.11.12 4 Way ( Composite ) 35.11.13 Double Domestic ( Only Supply ) 35.11.14 Double Domestic ( Only Labour ) 35.11.15 Double Domestic ( Composite ) 35.11.16 Water Proof Jb For Mk Switch ( To Be Used In Icu ) ( Only Supply ) 35.11.17 Water Proof Jb For Mk Switch ( To Be Used In Icu ) ( Only Labour ) 35.11.18 Water Proof Jb For Mk Switch ( To Be Used In Icu ) ( Composite ) 35.11.19 Legrand Make Modular Type Door Key Switch With Key Fob ( Only Supply ) 35.11.20 Legrand Make Modular Type Door Key Switch With Key Fob ( Only Labour ) 35.11.21 Legrand Make Modular Type Door Key Switch With Key Fob ( Composite ) 35.11.22 10A Modular Switch Legrand ( Only Supply ) 35.11.23 10A Modular Switch Legrand ( Only Labour ) 35.11.24 10A Modular Switch Legrand ( Composite ) 35.11.25 10A Modular Socket Legrand ( Only Supply ) 35.11.26 10A Modular Socket Legrand ( Only Labour ) 35.11.27 10A Modular Socket Legrand ( Composite ) 35.11.28 20A Modular Switch Legrand ( Only Supply ) 35.11.29 20A Modular Switch Legrand ( Only Labour ) 35.11.30 20A Modular Switch Legrand ( Composite ) 35.11.31 20A Modular Socket Legrand ( Only Supply ) 35.11.32 20A Modular Socket Legrand ( Only Labour ) 35.11.33 20A Modular Socket Legrand ( Composite ) 36.1 Supplying & Replacing The Following Spare Of Electrical Motor Starter Controls Etc. Or Whereever Applicable With Coil Voltage 240 V / 440 V.All As Per Instructions And As Directed By E-I-C, Es. Old Items Shall Be Returned To E-I-C, Es As It Is.Air Brake Contactors 36.1.1 Air Brake Contactor L & T Make Type Ml1 Or Equivalent ( Only Supply ) 36.1.2 Air Brake Contactor L & T Make Type Ml1 Or Equivalent ( Only Labour ) 36.1.3 Air Brake Contactor L & T Make Type Ml1 Or Equivalent ( Composite ) 36.1.4 Ml 1.5 Or Equivalent ( Only Supply ) 36.1.5 Ml 1.5 Or Equivalent ( Only Labour ) 36.1.6 Ml 1.5 Or Equivalent ( Composite ) 36.1.7 Ml 2 Or Equivalent ( Only Supply ) 36.1.8 Ml 2 Or Equivalent ( Only Labour ) 36.1.9 Ml 2 Or Equivalent ( Composite ) 36.1.10 Ml 3 Or Equivalent ( Only Supply ) 36.1.11 Ml 3 Or Equivalent ( Only Labour ) 36.1.12 Ml 3 Or Equivalent ( Composite ) 36.1.13 Ml 4 Or Equivalent ( Only Supply ) 36.1.14 Ml 4 Or Equivalent ( Only Labour ) 36.1.15 Ml 4 Or Equivalent ( Composite ) 36.1.16 Ml 6 Or Equivalent ( Only Supply ) 36.1.17 Ml 6 Or Equivalent ( Only Labour ) 36.1.18 Ml 6 Or Equivalent ( Composite ) 36.1.19 Ml 10 Or Equivalent ( Only Supply ) 36.1.20 Ml 10 Or Equivalent ( Only Labour ) 36.1.21 Ml 10 Or Equivalent ( Composite ) 36.1.22 Ml 12 Or Equivalent ( Only Supply ) 36.1.23 Ml 12 Or Equivalent ( Only Labour ) 36.1.24 Ml 12 Or Equivalent ( Composite ) 36.2 Supply & Replacement Of Following Spare Parts, Kit For L & T Or Equivalent Make Power Contactor. Work Is To Be Carried Out As Per Instructions Ans As Per Direction Of E-I-C, Es. Old / Remob Ved Items Shall Be Returned To E-I-C, Es As It Is. 36.2.1 Ml 1 Or Equivalent ( Only Supply ) 36.2.2 Ml 1 Or Equivalent ( Only Labour ) 36.2.3 Ml 1 Or Equivalent ( Composite ) 36.2.4 Ml 1.5 Or Equivalent ( Only Supply ) 36.2.5 Ml 1.5 Or Equivalent ( Only Labour ) 36.2.6 Ml 1.5 Or Equivalent ( Composite ) 36.2.7 Ml 2 Or Equivalent ( Only Supply ) 36.2.8 Ml 2 Or Equivalent ( Only Labour ) 36.2.9 Ml 2 Or Equivalent ( Composite ) 36.2.10 Ml 3 Or Equivalent ( Only Supply ) 36.2.11 Ml 3 Or Equivalent ( Only Labour ) 36.2.12 Ml 3 Or Equivalent ( Composite ) 36.2.13 Ml 4 Or Equivalent ( Only Supply ) 36.2.14 Ml 4 Or Equivalent ( Only Labour ) 36.2.15 Ml 4 Or Equivalent ( Composite ) 36.2.16 Ml 6 Or Equivalent ( Only Supply ) 36.2.17 Ml 6 Or Equivalent ( Only Labour ) 36.2.18 Ml 6 Or Equivalent ( Composite ) 36.2.19 Ml 10 Or Equivalent ( Only Supply ) 36.2.20 Ml 10 Or Equivalent ( Only Labour ) 36.2.21 Ml 10 Or Equivalent ( Composite ) 36.2.22 Ml 12 Or Equivalent ( Only Supply ) 36.2.23 Ml 12 Or Equivalent ( Only Labour ) 36.2.24 Ml 12 Or Equivalent ( Composite ) 36.3 Supply & Fixing Of Hrc Fuses As Per Instructions And As Directed By E-I-C, Es. Old / Removed Item Shall Be Returned To E-I-C, Es. 36.3.1 1A To 6A ( Only Supply ) 36.3.2 1A To 6A ( Only Labour ) 36.3.3 1A To 6A ( Composite ) 36.3.4 16A ( Only Supply ) 36.3.5 16A ( Only Labour ) 36.3.6 16A ( Composite ) 36.3.7 32A ( Only Supply ) 36.3.8 32A ( Only Labour ) 36.3.9 32A ( Composite ) 36.3.10 63A ( Only Supply ) 36.3.11 63A ( Only Labour ) 36.3.12 63A ( Composite ) 36.3.13 100A ( Only Supply ) 36.3.14 100A ( Only Labour ) 36.3.15 100A ( Composite ) 36.3.16 125A ( Only Supply ) 36.3.17 125A ( Only Labour ) 36.3.18 125A ( Composite ) 36.3.19 160A ( Only Supply ) 36.3.20 160A ( Only Labour ) 36.3.21 160A ( Composite ) 36.3.22 250A ( Only Supply ) 36.3.23 250A ( Only Labour ) 36.3.24 250A ( Composite ) 36.3.25 315A ( Only Supply ) 36.3.26 315A ( Only Labour ) 36.3.27 315A ( Composite ) 36.3.28 400A ( Only Supply ) 36.3.29 400A ( Only Labour ) 36.3.30 400A ( Composite ) 36.3.31 630A ( Only Supply ) 36.3.32 630A ( Only Labour ) 36.3.33 630A ( Composite ) 36.3.34 800 A ( Only Supply ) 36.3.35 800 A ( Only Labour ) 36.3.36 800 A ( Composite ) 36.4 Replacement Of The Following Item Make Bakelite Cut Out Complete Fuse Holder Db Mounted, All As Per Instructions And As Directed By E-I-C, Es. Old / Removed Items Shall Be Returened To E-I-C, Es. 36.4.1 16 A ( Only Supply ) 36.4.2 16 A ( Only Labour ) 36.4.3 16 A ( Composite ) 36.4.4 32 A ( Only Supply ) 36.4.5 32 A ( Only Labour ) 36.4.6 32 A ( Composite ) 36.4.7 63 A ( Only Supply ) 36.4.8 63 A ( Only Labour ) 36.4.9 63 A ( Composite ) 36.5 Replacement Of The Kit-Kat Fuse All As Per Instructions And As Directed By E-I-C, Es. Old / Removed Items Shall Be Returened To E-I-C, Es. 36.5.1 1A Delay Fuse ( Only Supply ) 36.5.2 1.5 A Delay Fuse ( Only Supply ) 36.5.3 5 Amps ( Only Supply ) 36.5.4 5 Amps ( Only Labour ) 36.5.5 5 Amps ( Composite ) 36.5.6 10 Amps ( Only Supply ) 36.5.7 10 Amps ( Only Labour ) 36.5.8 10 Amps ( Composite ) 36.5.9 15 Amps ( Only Supply ) 36.5.10 15 Amps ( Only Labour ) 36.5.11 15 Amps ( Composite ) 36.6 Replacement Of The Porcelain Fuse ( Base +Top ) All As Per Instructions And As Directed By E-I-C, Es. Old / Removed Items Shall Be Returened To E-I-C, Es. 36.6.1 5 Amps ( Only Supply ) 36.6.2 5 Amps ( Only Labour ) 36.6.3 5 Amps ( Composite ) 36.6.4 10 Amps ( Only Supply ) 36.6.5 10 Amps ( Only Labour ) 36.6.6 10 Amps ( Composite ) 36.6.7 25 Amps ( Only Supply ) 36.6.8 25 Amps ( Only Labour ) 36.6.9 25 Amps ( Composite ) 36.6.10 32 Amps ( Only Supply ) 36.6.11 32 Amps ( Only Labour ) 36.6.12 32 Amps ( Composite ) 36.7 Replacement Of The Neutral Link All As Per Instructions And As Directed By E-I-C, Es. Old / Removed Items Shall Be Returened To E-I-C, Es. 36.7.1 16 A ( Only Supply ) 36.7.2 16 A ( Only Labour ) 36.7.3 16 A ( Composite ) 36.7.4 32 A ( Only Supply ) 36.7.5 32 A ( Only Labour ) 36.7.6 32 A ( Composite ) 36.7.7 63 A ( Only Supply ) 36.7.8 63 A ( Only Labour ) 36.7.9 63 A ( Composite ) 36.8 Replacement Of Elmex / Connectwell Connector Block Suitable For Following Cable Sizes & Reconnection Of Vided Leads, All As Per Instructions And As Directed By E-I-C, Es. Old / Removed Items Shall Be Returned To E-I-C, Es As It Is. 36.8.1 1.5 Sq. Mm ( Only Supply ) 36.8.2 1.5 Sq. Mm ( Only Labour ) 36.8.3 1.5 Sq. Mm ( Composite ) 36.8.4 2.5 Sq. Mm ( Only Supply ) 36.8.5 2.5 Sq. Mm ( Only Labour ) 36.8.6 2.5 Sq. Mm ( Composite ) 36.8.7 4 Sq. Mm ( Only Supply ) 36.8.8 4 Sq. Mm ( Only Labour ) 36.8.9 4 Sq. Mm ( Composite ) 36.8.10 6 Sq. Mm ( Only Supply ) 36.8.11 6 Sq. Mm ( Only Labour ) 36.8.12 6 Sq. Mm ( Composite ) 36.8.13 10 Sq. Mm ( Only Supply ) 36.8.14 10 Sq. Mm ( Only Labour ) 36.8.15 10 Sq. Mm ( Composite ) 36.8.16 16 Sq. Mm ( Only Supply ) 36.8.17 16 Sq. Mm ( Only Labour ) 36.8.18 16 Sq. Mm ( Composite ) 36.8.19 25 Sq. Mm ( Only Supply ) 36.8.20 25 Sq. Mm ( Only Labour ) 36.8.21 25 Sq. Mm ( Composite ) 36.8.22 35 Sq. Mm ( Only Supply ) 36.8.23 35 Sq. Mm ( Only Labour ) 36.8.24 35 Sq. Mm ( Composite ) 36.8.25 50 Sq. Mm ( Only Supply ) 36.8.26 50 Sq. Mm ( Only Labour ) 36.8.27 50 Sq. Mm ( Composite ) 36.8.28 70 Sq. Mm ( Only Supply ) 36.8.29 70 Sq. Mm ( Only Labour ) 36.8.30 70 Sq. Mm ( Composite ) 36.8.31 95 Sq. Mm ( Only Supply ) 36.8.32 95 Sq. Mm ( Only Labour ) 36.8.33 95 Sq. Mm ( Composite ) 36.8.34 120 Sq. Mm ( Only Supply ) 36.8.35 120 Sq. Mm ( Only Labour ) 36.8.36 120 Sq. Mm ( Composite ) 36.8.37 Ct Shorting Terminals ( Only Supply ) 36.8.38 Ct Shorting Terminals ( Only Labour ) 36.8.39 Ct Shorting Terminals ( Composite ) 36.9 Supply / Replacement Of Terminal Strips / Blocks For Varios Types Of Motors Etc As Per Instructions And As Directed By E-I-C, Es. Old / Removed Items Shall Be Returned To E-I-C, Es As It Is. 36.9.1 Motors Up To 10 Hp ( Only Supply ) 36.9.2 Motors Up To 10 Hp ( Only Labour ) 36.9.3 Motors Up To 10 Hp ( Composite ) 36.9.4 Motors Up To 20 Hp ( Only Supply ) 36.9.5 Motors Up To 20 Hp ( Only Labour ) 36.9.6 Motors Up To 20 Hp ( Composite ) 36.9.7 Motors Up To 30 Hp ( Only Supply ) 36.9.8 Motors Up To 30 Hp ( Only Labour ) 36.9.9 Motors Up To 30 Hp ( Composite ) 36.9.10 Motors Up To 40 Hp ( Only Supply ) 36.9.11 Motors Up To 40 Hp ( Only Labour ) 36.9.12 Motors Up To 40 Hp ( Composite ) 36.9.13 Motors Up To 50 Hp ( Only Supply ) 36.9.14 Motors Up To 50 Hp ( Only Labour ) 36.9.15 Motors Up To 50 Hp ( Composite ) 36.9.16 Motors Up To 60 Hp ( Only Supply ) 36.9.17 Motors Up To 60 Hp ( Only Labour ) 36.9.18 Motors Up To 60 Hp ( Composite ) 37.1 .Ms Sheet For Boxes Etc Ms Sheet For 16 Swg To Be Used For Fabrication Of Boxes, Panels, Cable And Boxes Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc & Painting With Red Oxide Lead Paint & Two Coats Of Enamel Paint All As Per Instructions And As Directed By E-I-C, Es. 37.1.1 As Per Item No 37.1 For 14 Swg ( Only Supply ) 37.1.2 As Per Item No 37.1 For 14 Swg ( Only Labour ) 37.1.3 As Per Item No 37.1 For 14 Swg ( Composite ) 37.1.4 As Per Item No 37.1 For But For 16 Swg ( Only Supply ) 37.1.5 As Per Item No 37.1 For But For 16 Swg ( Only Labour ) 37.1.6 Sas Per Item No 37.1 For But For 16 Swg ( Composite ) 37.1.7 As Per Item No 37.1 For But For 18 Swg ( Only Supply ) 37.1.8 As Per Item No 37.1 For But For 18 Swg ( Only Labour ) 37.1.9 As Per Item No 37.1 For But For 18 Swg ( Composite ) 37.2 Supply, Fabrication & Installation Of Ms Angle / Strip / Plate / Rod / Channel Etc. As Per Given Design Duly Painted With 2 Coats Of Red Oxide & 2 Coats Of Enamel Paint Of Approved Shade All As Per The Instruction Of Eic. ( Composite ) 37.3 Hylam Sheet 3 Mm Thick To Be Used For Covering Ms Sheet Box Including Cutting, Drilling, Fixing With Nut Bolts / Screws, Cup Washers Etc. Complete As Required & To Satisfaction Of In Charge With Making Necessary Grove / Cutting For Fixing Electrical Accessories. ( Only Supply ) 37.3.1 Hylam Sheet 3 Mm Thick To Be Used For Covering Ms Sheet Box Including Cutting, Drilling, Fixing With Nut Bolts / Screws, Cup Washers Etc. Complete As Required & To Satisfaction Of In Charge With Making Necessary Grove / Cutting For Fixing Electrical Accessories. ( Only Labour ) 37.3.2 Hylam Sheet 3 Mm Thick To Be Used For Covering Ms Sheet Box Including Cutting, Drilling, Fixing With Nut Bolts / Screws, Cup Washers Etc. Complete As Required & To Satisfaction Of In Charge With Making Necessary Grove / Cutting For Fixing Electrical Accessories. ( Composite ) 37.4 Bakelite Sheet 3 Mm Thick To Be Used For Covering Ms Sheet Box Including Cutting, Drilling, Fixing With Nut Bolts / Screws, Cup Washers Etc. Complete As Required & To Satisfaction Of In Charge With Making Necessary Grove / Cutting For Fixing Electrical Accessories. ( Only Supply ) 37.4.1 Bakelite Sheet 3 Mm Thick To Be Used For Covering Ms Sheet Box Including Cutting, Drilling, Fixing With Nut Bolts / Screws, Cup Washers Etc. Complete As Required & To Satisfaction Of In Charge With Making Necessary Grove / Cutting For Fixing Electrical Accessories. ( Only Labour ) 37.4.2 Bakelite Sheet 3 Mm Thick To Be Used For Covering Ms Sheet Box Including Cutting, Drilling, Fixing With Nut Bolts / Screws, Cup Washers Etc. Complete As Required & To Satisfaction Of In Charge With Making Necessary Grove / Cutting For Fixing Electrical Accessories. ( Composite ) 37.5 Supplying & Erecting / Fixing 6 Mm Thick Marine Plywood Of Good Quality With Necessary Material ( Only Supply ) 37.5.1 Supplying & Erecting / Fixing 6 Mm Thick Marine Plywood Of Good Quality With Necessary Material ( Only Labour ) 37.5.2 Supplying & Erecting / Fixing 6 Mm Thick Marine Plywood Of Good Quality With Necessary Material ( Composite ) 38.1 Timers For Starters / Preventers Supply, Fixing & Testing Of On Delay Timer 0 To 60 Sec. ( Only Supply ) 38.2 Supply, Fixing & Testing Of On Delay Timer 0 To 60 Sec. ( Only Labour ) 38.3 Supply, Fixing & Testing Of On Delay Timer 0 To 60 Sec. ( Composite ) 38.4 Supply, Fixing & Testing Of Off Delay Timer ( Only Supply ) 38.5 Supply, Fixing & Testing Of Off Delay Timer ( Only Labour ) 38.6 Supply, Fixing & Testing Of Off Delay Timer ( Composite ) 38.7 Supply, Fixing & Testing Of Fm / 1 Quartz 24 Hrs Set Electronic Timer ( Only Supply ) 38.8 Supply, Fixing & Testing Of Star Delta Starter Timer [ 0-60 Sec. ] [ 1 No + 1 Nc ( Only Labour ) 38.9 Supply, Fixing & Testing Of Fm / 1 Quartz 24 Hrs Set Electronic Timer ( Composite ) 39 Supply, Fixing & Testing Of Star Delta Starter Timer [ 0-60 Sec. ] [ 1 No + 1 Nc ( Only Labour ) 39.1 Supply, Fixing & Testing Of Star Delta Starter Timer [ 0-60 Sec. ] [ 1 No + 1 Nc ( Only Labour ) 39.2 Supply, Fixing & Testing Of Star Delta Starter Timer [ 0-60 Sec. ] [ 1 No + 1 Nc ( Composite ) 39.3 Single Phase Preventer Type Mpr1 ( Only Supply ) 39.4 Single Phase Preventer Type Mpr1 ( Only Labour ) 39.5 Single Phase Preventer Type Mpr1 ( Composite ) 39.6 Supply, Fixing & Testing Of 0-24 Hrs Set Digital Timer ( Only Supply ) 39.7 Supply, Fixing & Testing Of 0-24 Hrs Set Digital Timer ( Only Labour ) 39.8 Supply, Fixing & Testing Of 0-24 Hrs Set Digital Timer ( Composit ) 40.1 Supply, Installation & Testing Of App Type Capacitors / Apfc Relays, 440 V, 50 Hz, All As Per Instructions Ans As Directed By E-I-C, Es Old / Removed Items Shall Be Returned To E-I-C, Es As It Is. 25 Kvar ( Only Supply ) 40.2 25 Kvar ( Only Labour ) 40.3 25 Kvar ( Composite ) 40.4 50 Kvar ( Only Supply ) 40.5 50 Kvar ( Only Labour ) 40.6 50 Kvar ( Composite ) 40.7 100 Kvar ( Only Supply ) 40.8 100 Kvar ( Only Labour ) 40.9 100 Kvar ( Composite ) 40.10.A Supply, Installation & Testing Of Apfc Relay Suitable For 8 Equal Steps, 440 V, 50 Hz, Ac. ( Only Supply ) 40.11 Supply, Installation & Testing Of Apfc Relay Suitable For 8 Equal Steps, 440 V, 50 Hz, Ac. ( Only Labour ) 40.12 Supply, Installation & Testing Of Apfc Relay Suitable For 8 Equal Steps, 440 V, 50 Hz, Ac. ( Composite ) 40.13 Supply, Installation & Testing Of Kvar Meter. 144 X 144 With Transducer. ( Only Supply ) 40.14 Supply, Installation & Testing Of Kvar Meter. 144 X 144 With Transducer. ( Only Labour ) 40.15 Supply, Installation & Testing Of Kvar Meter. 144 X 144 With Transducer. ( Composite ) 41.1 Fittings & Fixtures Supply / Replacement, Installation, Testing & Commissioning Of Following Various Fixtures & Fittings Complete With Fluorescent Tube / Incandescent Lamp / Pl-S Lamp Or Any Other Suitale Lamp Etc. On Surface Of Slab / Beam / Wall By Means Of Brackets Made Out Of 25 X 3 Mm Strip & 2 Nos. Of 6 Mm Anchor Fastener / Suspended From Slab / Beam By Means Of 19 Mm Dia. Conduit Pipe, Ball & Socket Arrangement Flexible 2 Core 40 / 30 Size Cable / Wire Connection Etc.Or By Means Of Suitable Fixing Arrangement, Complete In All Respect & As Per Instruction Of Engg. -In-Charge & With Prior Approval By Presenting Sample Fitting. Make:Philips / Crompton / Ge / Wipro / Orient Or Equivalent. In Case Of Replacement Old / Removed Items Shall Be Reuturned To E-I-C, Es As It Is. 1 X 40 W Rail ( Box ) Type Fluorescent Fitting ( Only Supply ) 41.2 1 X 40 W Rail ( Box ) Type Fluorescent Fitting ( Only Labour ) 41.3 1 X 40 W Rail ( Box ) Type Fluorescent Fitting ( Composite ) 41.4 2 X 40 W Rail Type Fluorescent ( Only Supply ) 41.5 2 X 40 W Rail Type Fluorescent ( Only Labour ) 41.6 2 X 40 W Rail Type Fluorescent ( Composite ) 41.7 2 X 40 W Decorative Mirror Optic Fluorescent Fitting ( Only Supply ) 41.8 2 X 40 W Decorative Mirror Optic Fluorescent Fitting ( Only Labour ) 41.9 2 X 40 W Decorative Mirror Optic Fluorescent Fitting ( Composite ) 41.10.A 1 X 40 W Decorative Mirror Optic Fluorescent Fitting ( Only Supply ) 41.11 1 X 40 W Decorative Mirror Optic Fluorescent Fitting ( Only Labour ) 41.12.A 1 X 40 W Decorative Mirror Optic Fluorescent Fitting ( Composite ) 41.13 2 X 40 W Industrial Type Fluorescent Fitting ( Only Supply ) 41.14 2 X 40 W Industrial Type Fluorescent Fitting ( Only Labour ) 41.15 2 X 40 W Industrial Type Fluorescent Fitting ( Composite ) 41.16 2 X 9 W Pl- S Decorative Recess Type Fitting. ( Only Supply ) 41.17.A 2 X 9 W Pl- S Decorative Recess Type Fitting. ( Only Labour ) 41.18 2 X 9 W Pl- S Decorative Recess Type Fitting. ( Composite ) 41.19 2 X 11 W Decorative Surface Type Fitting ( Only Supply ) 41.20.A 2 X 11 W Decorative Surface Type Fitting ( Only Labour ) 41.21 2 X 11 W Decorative Surface Type Fitting ( Composite ) 41.22 1 X 40 W Decorative Mirror Optic Fluorescent Fitting Surface Type ( Only Supply ) 41.23 1 X 40 W Decorative Mirror Optic Fluorescent Fitting Surface Type ( Only Labour ) 41.24 1 X 40 W Decorative Mirror Optic Fluorescent Fitting Surface Type ( Composite ) 41.25 2 X 40 W Decorative Mirror Optic Fluoresce Fitting Surface Type ( Only Supply ) 41.26 2 X 40 W Decorative Mirror Optic Fluoresce Fitting Surface Type ( Only Labour ) 41.27 2 X 40 W Decorative Mirror Optic Fluoresce Fitting Surface Type ( Composite ) 41.28 Bulkhead Fitting Suitable For Pl – S 9 W Lamp ( Only Supply ) 41.29 Bulkhead Fitting Suitable For Pl – S 9 W Lamp ( Only Labour ) 41.30.A Bulkhead Fitting Suitable For Pl – S 9 W Lamp ( Composite ) 41.31 1 X 30 W Germicidal Fluorescent Box Type Ss Fitting With Ulitrea-Violet Tube Light ( Only Supply ) 41.32 1 X 30 W Germicidal Fluorescent Box Type Ss Fitting With Ulitrea-Violet Tube Light ( Only Labour ) 41.33 1 X 30 W Germicidal Fluorescent Box Type Ss Fitting With Ulitrea-Violet Tube Light ( Composite ) 41.34 1 X 30 W Germicidal Fluorescent Box Type Fitting With Ulitrea-Violet Tube Light ( Only Supply ) 41.35 1 X 30 W Germicidal Fluorescent Box Type Fitting With Ulitrea-Violet Tube Light ( Only Labour ) 41.36 1 X 30 W Germicidal Fluorescent Box Type Fitting With Ulitrea-Violet Tube Light ( Composite ) 41.37 1 X 20 / 18 W Germicidal Fluorescent Box Type Fitting With Ulitrea-Violet Tube Light ( Only Supply ) 41.38 1 X 20 / 18 W Germicidal Fluorescent Box Type Fitting With Ulitrea-Violet Tube Light ( Only Labour ) 41.39 1 X 20 / 18 W Germicidal Fluorescent Box Type Fitting With Ulitrea-Violet Tube Light ( Composite ) 41.40.A 100 W Decorative Fixtures For The Dark Room ( Gemini Global Cat No. 3083 ) ( Only Supply ) 41.41 100 W Decorative Fixtures For The Dark Room ( Gemini Global Cat No. 3083 ) ( Only Labour ) 41.42 100 W Decorative Fixtures For The Dark Room ( Gemini Global Cat No. 3083 ) ( Composite ) 41.43 Decorative Incandescent Fixtures For Red Indication Lamp ( Only Supply ) 41.44 Decorative Incandescent Fixtures For Red Indication Lamp ( Only Labour ) 41.45 Decorative Incandescent Fixtures For Red Indication Lamp ( Composite ) 41.46 Decorative Incandescent Fixtures With 75 W Comptalux Lamp ( Only Supply ) 41.47 Decorative Incandescent Fixtures With 75 W Comptalux Lamp ( Only Labour ) 41.48 Decorative Incandescent Fixtures With 75 W Comptalux Lamp ( Composite ) 41.49 Decorative Incandescent Fixtures For Lecture Hall [ 100W ] ( ( Only Supply ) 41.50.A Decorative Incandescent Fixtures For Lecture Hall [ 100W ] ( ( Only Labour ) 41.51 Decorative Incandescent Fixtures For Lecture Hall [ 100W ] ( ( Composite ) 41.52 1 X 9 W Decorative Wall Mounted Fixtures With Electronic Ballast ( Only Supply ) 41.53 1 X 9 W Decorative Wall Mounted Fixtures With Electronic Ballast ( Only Labour ) 41.54 1 X 9 W Decorative Wall Mounted Fixtures With Electronic Ballast ( Composite ) 41.55 2 X 9 W Decorative Fixtures For ( Entrance Canopy ) ( Only Supply ) 41.56 2 X 9 W Decorative Fixtures For ( Entrance Canopy ) ( Only Labour ) 41.57 2 X 9 W Decorative Fixtures For ( Entrance Canopy ) ( Composite ) 41.58 2 X 25 W Exit Light Fixture ( Only Supply ) 41.59 2 X 25 W Exit Light Fixture ( Only Labour ) 41.60.A 2 X 25 W Exit Light Fixture ( Composite ) 41.61 2 X 18 W Fluorescent Industrial Fitting For Fume Hood ( Only Supply ) 41.62 2 X 18 W Fluorescent Industrial Fitting For Fume Hood ( Only Labour ) 41.63 2 X 18 W Fluorescent Industrial Fitting For Fume Hood ( Composite ) 41.64 1 X 9 W Decorative Surface Fitting For Wash Basin Mirror ( Only Supply ) 41.65 1 X 9 W Decorative Surface Fitting For Wash Basin Mirror ( Only Labour ) 41.66 1 X 9 W Decorative Surface Fitting For Wash Basin Mirror ( Composite ) 41.67 Night Lamp Fixture 15 W ( Only Supply ) 41.68 Night Lamp Fixture 15 W ( Only Labour ) 41.69 Night Lamp Fixture 15 W ( Composite ) 41.70.A Halogen Lamp Fitting. 41.70.1 Suitable For 500 W ( Only Supply ) 41.70.2 Suitable For 500 W ( Only Labour ) 41.70.3 Suitable For 500 W ( Composite ) 41.70.4 Suitable For 1000 W ( Only Supply ) 41.70.5 Suitable For 1000 W ( Only Labour ) 41.70.6 Suitable For 1000 W ( Composite ) 41.71 Decorative Incandescent Fixture With 60 W / 75 W Reflector Lamp ( Only Supply ) 41.72 Decorative Incandescent Fixture With 60 W / 75 W Reflector Lamp ( Only Labour ) 41.73 Decorative Incandescent Fixture With 60 W / 75 W Reflector Lamp ( Composite ) 41.74 Incandescent Lamp Fitting With 60 W / 100 W Lamp For Radiological Lab , Surface Type ( Only Supply ) 41.75 Incandescent Lamp Fitting With 60 W / 100 W Lamp For Radiological Lab , Surface Type ( Only Labour ) 41.76 Incandescent Lamp Fitting With 60 W / 100 W Lamp For Radiological Lab , Surface Type ( Composite ) 41.77 Incandescent Lamp Fitting With 60 W / 100 W Lamp For Radiological Lab , Recess Type ( Only Supply ) 41.78 Incandescent Lamp Fitting With 60 W / 100 W Lamp For Radiological Lab , Recess Type ( Only Labour ) 41.79 Incandescent Lamp Fitting With 60 W / 100 W Lamp For Radiological Lab , Recess Type ( Composite ) 41.80.A Recessed Adjustable Down Lighter With Separate T / F 1 X 12 V, 50 W Halogen ( Only Supply ) 41.81 Recessed Adjustable Down Lighter With Separate T / F 1 X 12 V, 50 W Halogen ( Only Labour ) 41.82 Recessed Adjustable Down Lighter With Separate T / F 1 X 12 V, 50 W Halogen ( Composite ) 41.83 Floor Washer ( Only Supply ) 41.84 Floor Washer ( Only Labour ) 41.85 Floor Washer ( Composite ) 41.86 Turbolite With 6 Cell Reflector ( Only Supply ) 41.87 Turbolite With 6 Cell Reflector ( Only Labour ) 41.88 Turbolite With 6 Cell Reflector ( Composite ) 41.89 Solaris Down Lighter ( Only Supply ) 41.90.A Solaris Down Lighter ( Only Labour ) 41.91 Solaris Down Lighter ( Composite ) 41.92 Moisture Proof Halogen Recessed Fixture ( Only Supply ) 41.93 Moisture Proof Halogen Recessed Fixture ( Only Labour ) 41.94 Moisture Proof Halogen Recessed Fixture ( Composite ) 41.95 Gemini Baflux Max 2X 18 W Plc Lamp ( Only Supply ) 41.96 Gemini Baflux Max 2X 18 W Plc Lamp ( Only Labour ) 41.97 Gemini Baflux Max 2X 18 W Plc Lamp ( Composite ) 41.98 Rivia Mini With 1 Plc -10W ( Only Supply ) 41.99 Rivia Mini With 1 Plc -10W ( Only Labour ) 41.100.A Rivia Mini With 1 Plc -10W ( Composite ) 41.101 Emergency Tube Light Fixture Suitable To Fix 9W Pl Lamp, ( Only Supply ) 41.102 Emergency Tube Light Fixture Suitable To Fix 9W Pl Lamp, ( Only Labour ) 41.103 Emergency Tube Light Fixture Suitable To Fix 9W Pl Lamp, ( Composite ) 41.104 Reputed Make Tbs 300 / 418 M1 Hpf , 4 X ‘Tl’D 18 W / Tl 20 W Recessed Mounting Mirror Optic Fluorescent Lighting Fixture. ( Only Supply ) 41.105 Reputed Make Tbs 300 / 418 M1 Hpf , 4 X ‘Tl’D 18 W / Tl 20 W Recessed Mounting Mirror Optic Fluorescent Lighting Fixture. ( Only Labour ) 41.106 Reputed Make Tbs 300 / 418 M1 Hpf , 4 X ‘Tl’D 18 W / Tl 20 W Recessed Mounting Mirror Optic Fluorescent Lighting Fixture. ( Composite ) 41.107 Reputed Make Fbs 285 / 218 2 X Pl-L 18 W Recessed Mirror Optic Pl Fitting Or Equivalent ( Only Supply ) 41.108 Reputed Make Fbs 285 / 218 2 X Pl-L 18 W Recessed Mirror Optic Pl Fitting Or Equivalent ( Only Labour ) 41.109 Reputed Make Fbs 285 / 218 2 X Pl-L 18 W Recessed Mirror Optic Pl Fitting Or Equivalent ( Composite ) 41.110.A Dn 622 ( White ) Recessed Accent Lighting With Matt Finished With Reflector, Reputed Make Suitable Or 1 X 100 W Glass Lamp Or Equivalent ( Only Supply ) 41.111 Dn 622 ( White ) Recessed Accent Lighting With Matt Finished With Reflector, Reputed Make Suitable Or 1 X 100 W Glass Lamp Or Equivalent ( Only Labour ) 41.112 Dn 622 ( White ) Recessed Accent Lighting With Matt Finished With Reflector, Reputed Make Suitable Or 1 X 100 W Glass Lamp Or Equivalent ( Composite ) 41.113 Fdn 622 / 01 ( White ) Recessed Accent Lighting With Matt Finished With Reflector Inclusive Of Gear Box, Reputed Make , Suitable For 1 X Pl-S 9W, Or Equivalent ( Only Supply ) 41.114 Fdn 622 / 01 ( White ) Recessed Accent Lighting With Matt Finished With Reflector Inclusive Of Gear Box, Reputed Make , Suitable For 1 X Pl-S 9W, Or Equivalent ( Only Labour ) 41.115 Fdn 622 / 01 ( White ) Recessed Accent Lighting With Matt Finished With Reflector Inclusive Of Gear Box, Reputed Make , Suitable For 1 X Pl-S 9W, Or Equivalent ( Composite ) 41.116 Fbh 145 / 113 Low Depth Recessed Low Glare Down Lighter Inclusive Of Enclosed Control Gear Box , Matt Finish Reflector Including Glass Attachment, Suitable For 1 X Pl-C 10 / 13 W , Reputed Make Or Equivalent ( Only Supply ) 41.117 Fbh 145 / 113 Low Depth Recessed Low Glare Down Lighter Inclusive Of Enclosed Control Gear Box , Matt Finish Reflector Including Glass Attachment, Suitable For 1 X Pl-C 10 / 13 W , Reputed Make Or Equivalent ( Only Labour ) 41.118 Fbh 145 / 113 Low Depth Recessed Low Glare Down Lighter Inclusive Of Enclosed Control Gear Box , Matt Finish Reflector Including Glass Attachment, Suitable For 1 X Pl-C 10 / 13 W , Reputed Make Or Equivalent ( Composite ) 41.119 Fbh 145 / 213 Low Depth Recessed Low Glare Down Lighter Inclusive Of Enclosed Control Gear Box , Matt Finish Reflector Including Glass Attachment, Suitable For 2 X Pl-C 10 / 13 W , Reputed Make Or Equivalent ( Only Supply ) 41.120.A Fbh 145 / 213 Low Depth Recessed Low Glare Down Lighter Inclusive Of Enclosed Control Gear Box , Matt Finish Reflector Including Glass Attachment, Suitable For 2 X Pl-C 10 / 13 W , Reputed Make Or Equivalent ( Only Labour ) 41.121 Fbh 145 / 213 Low Depth Recessed Low Glare Down Lighter Inclusive Of Enclosed Control Gear Box , Matt Finish Reflector Including Glass Attachment, Suitable For 2 X Pl-C 10 / 13 W , Reputed Make Or Equivalent ( Composite ) 41.122 Dn 652, Recessed Adjustable Accent Lighting Luminary Inclusive Of Separate Transformer With Lamp Or Equivalent ( Only Supply ) 41.123 Dn 652, Recessed Adjustable Accent Lighting Luminary Inclusive Of Separate Transformer With Lamp Or Equivalent ( Only Labour ) 41.124 Dn 652, Recessed Adjustable Accent Lighting Luminary Inclusive Of Separate Transformer With Lamp Or Equivalent ( Composite ) 41.125 2 X 36W Pll Fixture ( Only Supply ) 41.126 2 X 36W Pll Fixture ( Only Labour ) 41.127 2 X 36W Pll Fixture ( Composite ) 41.128 25W, Plc, Lighting Fixture ( Only Supply ) 41.129 25W, Plc, Lighting Fixture ( Only Labour ) 41.130.A 25W, Plc, Lighting Fixture ( Composite ) 41.131 1X28w, Energy Efficient Box Type Fitting ( Only Supply ) 41.132 1X28w, Energy Efficient Box Type Fitting ( Only Labour ) 41.133 1X28w, Energy Efficient Box Type Fitting ( Composite ) 41.134 25W, Plc Lighting Fixture ( Only Supply ) 41.135 25W, Plc Lighting Fixture ( Only Labour ) 41.136 25W, Plc Lighting Fixture ( Composite ) 41.137 Led Light Fixtures 6W Recessed Mounted Led Lighting Fixture ( Only Supply ) 41.138 6W Recessed Mounted Led Lighting Fixture ( Only Labour ) 41.139 6W Recessed Mounted Led Lighting Fixture ( Composite ) 41.140.A 9W Recessed Mounted Led Lighting Fixture ( Only Supply ) 41.141 9W Recessed Mounted Led Lighting Fixture ( Only Labour ) 41.142 9W Recessed Mounted Led Lighting Fixture ( Composite ) 41.143 12W Recessed Mounted Led Lighting Fixture ( Only Supply ) 41.144 12W Recessed Mounted Led Lighting Fixture ( Only Labour ) 41.145 12W Recessed Mounted Led Lighting Fixture ( Composite ) 41.146 15W Recessed Mounted Led Lighting Fixture ( Only Supply ) 41.147 15W Recessed Mounted Led Lighting Fixture ( Only Labour ) 41.148 15W Recessed Mounted Led Lighting Fixture ( Composite ) 41.149 18W Recessed Mounted Led Lighting Fixture ( Only Supply ) 41.150.A 18W Recessed Mounted Led Lighting Fixture ( Only Labour ) 41.151 18W Recessed Mounted Led Lighting Fixture ( Composite ) 41.152 24W Recessed Mounted Led Lighting Fixture ( Only Supply ) 41.153 24W Recessed Mounted Led Lighting Fixture ( Only Labour ) 41.154 24W Recessed Mounted Led Lighting Fixture ( Composite ) 41.155 3W Recessed Led Type Halogen Lighting Fixture ( Only Supply ) 41.156 3W Recessed Led Type Halogen Lighting Fixture ( Only Labour ) 41.157 3W Recessed Led Type Halogen Lighting Fixture ( Composite ) 41.158 6W Recessed Led Type Halogen Lighting Fixture ( Only Supply ) 41.159 6W Recessed Led Type Halogen Lighting Fixture ( Only Labour ) 41.160.A 6W Recessed Led Type Halogen Lighting Fixture ( Composite ) 41.161 9W Recessed Led Type Halogen Lighting Fixture ( Only Supply ) 41.162 9W Recessed Led Type Halogen Lighting Fixture ( Only Labour ) 41.163 9W Recessed Led Type Halogen Lighting Fixture ( Composite ) 41.164 36W, 2X2 Size Recessed Led Lighting Fixture ( Only Supply ) 41.165 36W, 2X2 Size Recessed Led Lighting Fixture ( Only Labour ) 41.166 36W, 2X2 Size Recessed Led Lighting Fixture ( Composite ) 41.167 42W, 2X2 Size Recessed Led Lighting Fixture ( Only Supply ) 41.168 42W, 2X2 Size Recessed Led Lighting Fixture ( Only Labour ) 41.169 42W, 2X2 Size Recessed Led Lighting Fixture ( Composite ) 41.170 32W, 4 Long Fully Diffused Recessed Led Lighting Fixture ( Only Supply ) 41.171 32W, 4 Long Fully Diffused Recessed Led Lighting Fixture ( Only Labour ) 41.172 32W, 4 Long Fully Diffused Recessed Led Lighting Fixture ( Composite ) 41.173 6W Surface Mounted Led Lighting Fixture ( Only Supply ) 41.174 6W Surface Mounted Led Lighting Fixture ( Only Labour ) 41.175 6W Surface Mounted Led Lighting Fixture ( Composite ) 41.176 9W Surface Mounted Led Lighting Fixture ( Only Supply ) 41.177 9W Surface Mounted Led Lighting Fixture ( Only Labour ) 41.178 9W Surface Mounted Led Lighting Fixture ( Composite ) 41.179 12W Surface Mounted Led Lighting Fixture ( Only Supply ) 41.180 12W Surface Mounted Led Lighting Fixture ( Only Labour ) 41.181 12W Surface Mounted Led Lighting Fixture ( Composite ) 41.182 15W Surface Mounted Led Lighting Fixture ( Only Supply ) 41.183 15W Surface Mounted Led Lighting Fixture ( Only Labour ) 41.184 15W Surface Mounted Led Lighting Fixture ( Composite ) 41.185 18W Surface Mounted Led Lighting Fixture ( Only Supply ) 41.186 18W Surface Mounted Led Lighting Fixture ( Only Labour ) 41.187 18W Surface Mounted Led Lighting Fixture ( Composite ) 41.188 24W Surface Type Led Lighting Fixture ( Only Supply ) 41.189 24W Surface Type Led Lighting Fixture ( Only Labour ) 41.190 24W Surface Type Led Lighting Fixture ( Composite ) 41.191 22W, 4 Long Surface Type Led Lighting Fixture ( Only Supply ) 41.192 22W, 4 Long Surface Type Led Lighting Fixture ( Only Labour ) 41.193 22W, 4 Long Surface Type Led Lighting Fixture ( Composite ) 41.194 8W, 2 Long Surface Type Led Lighting Fixture ( Only Supply ) 41.195 8W, 2 Long Surface Type Led Lighting Fixture ( Only Labour ) 41.196 8W, 2 Long Surface Type Led Lighting Fixture ( Composite ) 41.197 32W, 4 Long Fully Diffused Surface Led Lighting Fixture ( Only Supply ) 41.198 32W, 4 Long Fully Diffused Surface Led Lighting Fixture ( Only Labour ) 41.199 32W, 4 Long Fully Diffused Surface Led Lighting Fixture ( Composite ) 41.200 22W, 4 Long Led Tube ( Only Supply ) With One Year Warranty 41.201 22W, 4 Long Led Tube ( Only Labour ) 41.202 22W, 4 Long Led Tube ( Only Composite ) 42 Providing, Fixing & Commissioning Of Ceiling Fan White / Brown Colour As Per Requirement Including Down Rod, Double Ball Baring Etc All As Per Instructions And As Directed By E-I-C, Es. In Case Of Replacement Old / Removed Item Shall Be Returned To E-I-C, Es As It Is. 42.1 Size 1400 Mm Sweep ( Only Supply ) 42.2 Size 1400 Mm Sweep ( Only Labour ) 42.3 Size 1400 Mm Sweep ( Composite ) 42.4 Size 1200 Mm Sweep ( Only Supply ) 42.5 Size 1200 Mm Sweep ( Only Labour ) 42.6 Size 1200 Mm Sweep ( Composite ) 42.7 Size 900 Mm Sweep ( Only Supply ) 42.8 Size 900 Mm Sweep ( Only Labour ) 42.9 Size 900 Mm Sweep ( Composite ) 42.10.A Same As Per Item No 42 But For Wall Mounted Fan 42.10.1 Providing 1 Phase Decorative Type 4 Speed Wall Mounted Fan, Roller Button, Having Swap Facility, ( Only Supply ) 42.10.2 Providing 1 Phase Decorative Type 4 Speed Wall Mounted Fan, Roller Button, Having Swap Facility, ( Only Labour ) 42.10.3 Providing 1 Phase Decorative Type 4 Speed Wall Mounted Fan, Roller Button, Having Swap Facility, ( Composite ) 42.11 Same As Per Item No 42 But For Pedestal Mounted Fan 42.11.1 Providing 1 Phase Decorative Type Pedestal Fan, Roller Button, Having Swap Facility, ( Only Supply ) 42.11.2 Providing 1 Phase Decorative Type Pedestal Fan, Roller Button, Having Swap Facility, ( Only Labour ) 42.11.3 Providing 1 Phase Decorative Type Pedestal Fan, Roller Button, Having Swap Facility, ( Composite ) 42.11.4 Providing 1 Phase Heavy Dutye Type Pedestal Fan, Roller Button, Having Swap Facility, ( Only Supply ) 42.11.5 Providing 1 Phase Heavy Dutye Type Pedestal Fan, Roller Button, Having Swap Facility, ( Only Labour ) 42.11.6 Providing 1 Phase Heavy Dutye Type Pedestal Fan, Roller Button, Having Swap Facility, ( Composite ) 43 Providing & Erecting 1 Phase Or Exhaust Fan Metal Body With Ms Frame & Gravity Louvers, 1400 Rpm, 230 V, 50 Hz, All As Per Instructions And As Directed By E-I-C, Es. In Case Of Replacement Old / Removed Items Shall Be Returned To E-I-C, Es. 43.1.A 150 Mm ( Only Supply ) 43.2 150 Mm ( Only Labour ) 43.3 150 Mm ( Composite ) 43.4 200 Mm ( Only Supply ) 43.5 200 Mm ( Only Labour ) 43.6 200 Mm ( Composite ) 43.7 225 Mm ( Only Supply ) 43.8 225 Mm ( Only Labour ) 43.9 225 Mm ( Composite ) 43.10 300 Mm ( Only Supply ) 43.11 300 Mm ( Only Labour ) 43.12 300 Mm ( Composite ) 43.13 375 Mm ( Only Supply ) 43.14 375 Mm ( Only Labour ) 43.15 375 Mm ( Composite ) 43.16 450 Mm ( Only Supply ) 43.17 450 Mm ( Only Labour ) 43.18 450 Mm ( Composite ) Street Lighting Supply / Replacement, Testing & Commissioning Of External Terminal Box Of Size 200 X 250 X 150 Mm Made Of 4 Mm Thick Cast Iron / Pvc, Neatly Painted Complete With Front Operable Door With Allen Key Locking Arrangement, Arrangement For Gland Entry, Water Proof Gasket, 4 Nos. Of 8 Mm Dia. 40 Mm Long Brass Terminals On 150 X 30 X 10 Mm Bakelite Strip, 16 A Hrc Fuse Base & Carrier With 6 A Hrc Fuse / 16A Sp Mcb, 16 A Neutral Link, Nipple Or Sleeve Of External Dia. 38 Mm Which Can Be Inserted In 38 Mm Dia. Gi Pipe, All As Directed By O-I-C, Es. Equvilent Arrangement Can Be Done Only After Prior Approval For Make As Well As Other Releted Fixing / Control Gear Arrangement. In Case Of Replacement Old / Removed Item Shall Be Returned To E-I-C, Es. Led Street Light Fitting Of Following Ratings Having Pressure Die-Cast Aluminimum Housing With Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint , Suitable To Following Features. - Luminaires Suitable With Base Plate And Fitted On A Existing Site Pole.-In Built Electronic Led Driver, -High Transmisivity Diffuser>85%, -Ip-65 / 67-High Efficacy, -Provide Uniform Low Glare Lighting , -Cri-70, -Warm White-Operating Temperature:--40 To +60 Celsius Degree-Operatable Voltage - 220-240 V, 50 Hz, Pf>0.9, 44.1.1 70 / 85W Cfl Lamp Fitting ( Only Supply ) 44.1.2 70 / 85W Cfl Lamp Fitting ( Only Labour ) 44.1.3 70 / 85W Cfl Lamp Fitting ( Composite ) 44.1.4 9 / 11W, 12V, 75 Ah Solar Stree Light Fitting ( Only Supply ) 44.1.5 9 / 11W, 12V, 75 Ah Solar Stree Light Fitting ( Only Labour ) 44.1.6 9 / 11W, 12V, 75 Ah Solar Stree Light Fitting ( Composite ) 44.1.7 Led Street Lights 20W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.8 20W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.9 20W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.10 25W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.11 25W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.12 25W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.13 35W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.14 35W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.15 35W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.16 60W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.17 60W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.18 60W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.19 70W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.20 70W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.21 70W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.22 90W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.23 90W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.24 90W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.25 120W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.26 120W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.27 120W, Led Street Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.28 20W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.29 20W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.30 20W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.31 30W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.32 30W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.33 30W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.34 50W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.35 50W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.36 50W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.37 80W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.38 80W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.39 80W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.40 100W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.41 100W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.42 100W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.43 120W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.44 120W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.45 120W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.46 150W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.47 150W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.48 150W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.49 200W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.50 200W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.51 200W, Led Flood Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.52 30W, Led Dom Light Fitting, Ip-65 / 67 Outdoor Type ( Only Supply ) 44.1.53 30W, Led Dom Light Fitting, Ip-65 / 67 Outdoor Type ( Only Labour ) 44.1.54 30W, Led Dom Light Fitting, Ip-65 / 67 Outdoor Type ( Composite ) 44.1.55 Led Street Light Drivers20w, Led Street Light Driver ( Only Supply ) 44.1.56 20W, Led Street Light Driver ( Only Labour ) 44.1.57 20W, Led Street Light Driver ( Composite ) 44.1.58 25W, Led Street Light Driver ( Only Supply ) 44.1.59 25W, Led Street Light Driver ( Only Labour ) 44.1.60 25W, Led Street Light Driver ( Composite ) 44.1.61 30 / 40W, Led Street Light Driver ( Only Supply ) 44.1.62 30 / 40W, Led Street Light Driver ( Only Labour ) 44.1.63 30 / 40W, Led Street Light Driver ( Composite ) 44.1.64 60W, Led Street Light Driver ( Only Supply ) 44.1.65 60W, Led Street Light Driver ( Only Labour ) 44.1.66 60W, Led Street Light Driver ( Composite ) 44.1.67 70W, Led Street Light Driver ( Only Supply ) 44.1.68 70W, Led Street Light Driver ( Only Labour ) 44.1.69 70W, Led Street Light Driver ( Composite ) 44.1.70 90W, Led Street Light Driver ( Only Supply ) 44.1.71 90W, Led Street Light Driver ( Only Labour ) 44.1.72 90W, Led Street Light Driver ( Composite ) 44.1.73 120W, Led Street Light Driver ( Only Supply ) 44.1.74 120W, Led Street Light Driver ( Only Labour ) 44.1.75 120W, Led Street Light Driver ( Composite ) 44.1.76 150W, Led Street Light Driver ( Only Supply ) 44.1.77 150W, Led Street Light Driver ( Only Labour ) 44.1.78 150W, Led Street Light Driver ( Composite ) 44.1.79 200W, Led Street Light Driver ( Only Supply ) 44.1.80 200W, Led Street Light Driver ( Only Labour ) 44.1.81 200W, Led Street Light Driver ( Composite ) 44.2 Street Light Pole Erection 44.2.1 7 Mtr. Hot Dip Galvanised Octagonal Street Light Pole With 1.5M Long Single Arm Bracket, Suitable For 44 M / Sec Wind Speed With Suitable Foundation Bolts, Bakelite With 1 No. 6A Sp Mcb And Stud Type Terminal Block / Connector Box Of Approved Make Suitable For Terminating Cable Up To 4Cx16 Sqmm Size ( Only Supply ) . 44.2.2 7 Mtr. Hot Dip Galvanised Octagonal Street Light Pole With 1.5M Long Single Arm Bracket, Suitable For 44 M / Sec Wind Speed With Suitable Foundation Bolts, Bakelite With 1 No. 6A Sp Mcb And Stud Type Terminal Block / Connector Box Of Approved Make Suitable For Terminating Cable Up To 4Cx16 Sqmm Size ( Only Labour ) . 44.2.3 7 Mtr. Hot Dip Galvanised Octagonal Street Light Pole With 1.5M Long Single Arm Bracket, Suitable For 44 M / Sec Wind Speed With Suitable Foundation Bolts, Bakelite With 1 No. 6A Sp Mcb And Stud Type Terminal Block / Connector Box Of Approved Make Suitable For Terminating Cable To 4Cx16 Sqmm Size ( Composite ) . 44.2.4 Same As Item No. 44.3.3 But With Double Arm Brackets ( Only Supply ) . 44.2.5 Same As Item No. 44.3.3 But With Double Arm Brackets ( Only Labour ) . 44.2.6 Same As Item No. 44.3.3 But With Double Arm Brackets ( Composite ) . 44.2.7 7 Mtr. Hot Dip Galvanised Octagonal Street Light Pole With Hexagonal Bracket Suitable To Mount Integral Flood Light Fixture & 1.5M Double Arm Bracket Suitable To Mount Two Nos. Of Street Light Fixture. Suitable For 47 M / Sec Wind Speed. ( Fixtures Can Be Mounted On The Hexagonal Bracket On Six Sides Of The Bracket But At Max Only 3 No. Of Integral Flood Lights Can Be Mounted At A Time. ) .With Suitable Foundation Bolts, Bakelite With 2 Nos. 6A Sp Mcb And Stud Type Terminal Block / Connector Box Of Approved Make Suitable For Terminating Cable Up To 4Cx16 Sqmm Size ( Only Supply ) . 7 Mtr. Hot Dip Galvanised Octagonal Street Light Pole With Hexagonal Bracket Suitable To Mount Integral Flood Light Fixture & 1.5M Double Arm Bracket Suitable To Mount Two Nos. Of Street Light Fixture. Suitable For 47 M / Sec Wind Speed. ( Fixtures Can Be Mounted On The Hexagonal Bracket On Six Sides Of The Bracket But At Max Only 3 No. Of Integral Flood Lights Can Be Mounted At A Time. ) .With Suitable Foundation Bolts, Bakelite With 2 Nos. 6A Sp Mcb And Stud Type Terminal Block / Connector Box Of Approved Make Suitable For Terminating Cable Up To 4Cx16 Sqmm Size ( Only Labour ) . 7 Mtr. Hot Dip Galvanised Octagonal Street Light Pole With Hexagonal Bracket Suitable To Mount Integral Flood Light Fixture & 1.5M Double Arm Bracket Suitable To Mount Two Nos. Of Street Light Fixture. Suitable For 47 M / Sec Wind Speed. ( Fixtures Can Be Mounted On The Hexagonal Bracket On Six Sides Of The Bracket But At Max Only 3 No. Of Integral Flood Lights Can Be Mounted At A Time. ) .With Suitable Foundation Bolts, Bakelite With 2 Nos. 6A Sp Mcb And Stud Type Terminal Block / Connector Box Of Approved Make Suitable For Terminating Cable Up To 4Cx16 Sqmm Size ( Composite ) . 3 Mtr. Hot Dip Galvanised Octagonal Post Top Type Pole Having Spigot On Top Of Pole, Suitable For 44 M / Sec Wind Speed With Foundation Bolts, Bakelite With 1 No. 6A Sp Mcb And Stud Type Terminal Block / Connector Box Of Approved Make Suitable For Terminating Cable Up To 4Cx16 Sqmm Size ( Only Supply ) . 3 Mtr. Hot Dip Galvanised Octagonal Post Top Type Pole Having Spigot On Top Of Pole, Suitable For 44 M / Sec Wind Speed With Foundation Bolts, Bakelite With 1 No. 6A Sp Mcb And Stud Type Terminal Block / Connector Box Of Approved Make Suitable For Terminating Cable Up To 4Cx16 Sqmm Size ( Only Labour ) . 3 Mtr. Hot Dip Galvanised Octagonal Post Top Type Pole Having Spigot On Top Of Pole, Suitable For 44 M / Sec Wind Speed With Foundation Bolts, Bakelite With 1 No. 6A Sp Mcb And Stud Type Terminal Block / Connector Box Of Approved Make Suitable For Terminating Cable Up To 4Cx16 Sqmm Size ( Composite ) . Casting Of New Foundation For 7 Mtr. Poles Of Above Type Inlcuding Excavation Of Pole Pit. The Concrete Mix For Rcc Foundation Of Octagonal Pole Shall Be M20. The Scope Shall Also Include Grouting Of Foundation Bolts Including Curing & Provision Of Dwc Hdpe Pipe For Passage The Cable And Finishing The Surface ( Composite ) . Casting Of New Foundation For 3 Mtr. Poles Of Above Type Inlcuding Excavation Of Pole Pit. The Concrete Mix For Rcc Foundation Of Octagonal Pole Shall Be M20. The Scope Shall Also Include Grouting Of Foundation Bolts Including Curing & Provision Of Dwc Hdpe Pipe For Passage The Cable And Finishing The Surface ( Composite ) . Lamp Holders 44.4 Lamp Holders 44.4.1 Lamp Holders For Lamp ( Any Type ) Inclusive Of Halogen Holder Assembly. ( Only Supply ) 44.4.2 Lamp Holders For Lamp ( Any Type ) Inclusive Of Halogen Holder Assembly. ( Only Labour ) 44.4.3 Lamp Holders For Lamp ( Any Type ) Inclusive Of Halogen Holder Assembly. ( Composite ) 44.6.25 Supply & Fixing Of 70W Cfl Lamp Reputed Make ( Only Supply ) 44.6.26 Supply & Fixing Of 70W Cfl Lamp Reputed Make ( Only Labour ) 44.6.27 Supply & Fixing Of 70W Cfl Lamp Reputed Make ( Composite ) 44.6.28 Supply & Fixing Of 65W Cfl Lamp Reputed Make ( Only Supply ) 44.6.29 Supply & Fixing Of 65W Cfl Lamp Reputed Make ( Only Labour ) 44.6.30 Supply & Fixing Of 65W Cfl Lamp Reputed Make ( Composite ) 44.6.31 Supply & Fixing Of 85W Cfl Lamp Reputed Make ( Only Supply ) 44.6.32 Supply & Fixing Of 85W Cfl Lamp Reputed Make ( Only Labour ) 44.6.33 Supply & Fixing Of 85W Cfl Lamp Reputed Make ( Composite ) 44.6.34 Supply & Fixing Of 35W Cfl Lamp Reputed Make ( Only Supply ) 44.6.35 Supply & Fixing Of 35W Cfl Lamp Reputed Make ( Only Labour ) 44.6.36 Supply & Fixing Of 35W Cfl Lamp Reputed Make ( Composite ) 45.1 Telephone System All General Guidelines Will Be As Per Any Kind Of Point Wiring. Telephone Point Wiring With 2 Pair 0.5 Mm Guage Unarmored Wire Laid Through Rigid Pvc Pipe ( Only Supply ) 45.2 Telephone Point Wiring With 2 Pair 0.5 Mm Guage Unarmored Wire Laid Through Rigid Pvc Pipe ( Only Labour ) 45.3 Telephone Point Wiring With 2 Pair 0.5 Mm Guage Unarmored Wire Laid Through Rigid Pvc Pipe ( Composite ) 45.4 Telephone Point Wiring With 2 Pair 0.5 Mm Guage Unarmored Wire Should Be Drawn Through Pvc Casing Capping. ( Only Supply ) 45.5 Telephone Point Wiring With 2 Pair 0.5 Mm Guage Unarmored Wire Should Be Drawn Through Pvc Casing Capping. ( Only Labour ) 45.6 Telephone Point Wiring With 2 Pair 0.5 Mm Guage Unarmored Wire Should Be Drawn Through Pvc Casing Capping. ( Composite ) 45.7 Telephone Point Wiring With 5 Pair 0.5 Mm Guage Unarmored Wire Should Be Drawn Through Pvc Rigid Pipe. ( Only Supply ) 45.8 Telephone Point Wiring With 5 Pair 0.5 Mm Guage Unarmored Wire Should Be Drawn Through Pvc Rigid Pipe. ( Only Labour ) 45.9 Telephone Point Wiring With 5 Pair 0.5 Mm Guage Unarmored Wire Should Be Drawn Through Pvc Rigid Pipe. ( Composite ) 45.10.A Telephone Point Wiring With 5 Pair 0.5 Mm Guage Unarmored Wire Should Be Drawn Through Pvc Casing Capping. ( Only Supply ) 45.11 Telephone Point Wiring With 5 Pair 0.5 Mm Guage Unarmored Wire Should Be Drawn Through Pvc Casing Capping. ( Only Labour ) 45.12 Telephone Point Wiring With 5 Pair 0.5 Mm Guage Unarmored Wire Should Be Drawn Through Pvc Casing Capping. ( Composite ) 45.13 Telephone Point Wiring With 1 Pair 0.5 Mm Gauge Unarmored Wire Should Be Drawn Through Pvc Casing Capping. ( Only Supply ) 45.14 Telephone Point Wiring With 1 Pair 0.5 Mm Gauge Unarmored Wire Should Be Drawn Through Pvc Casing Capping. ( Only Labour ) 45.15 Telephone Point Wiring With 1 Pair 0.5 Mm Gauge Unarmored Wire Should Be Drawn Through Pvc Casing Capping. ( Composite ) 45.16 Telephone Point Wiring With 1 Pair 0.5 Mm Gauge Unarmored Wire Should Be Drawn Through Pvc Rigid Pipe. ( Only Supply ) 45.17 Telephone Point Wiring With 1 Pair 0.5 Mm Gauge Unarmored Wire Should Be Drawn Through Pvc Rigid Pipe. ( Only Labour ) 45.18 Telephone Point Wiring With 1 Pair 0.5 Mm Gauge Unarmored Wire Should Be Drawn Through Pvc Rigid Pipe. ( Composite ) 45.19 Telephone Point Wiring With 1 Pair 0.5 Mm Gauge Unarmored Wire Should Be Drawn Through Provided Pvc Rigid Pipe / Casing Capping. 45.19.1 1 Pair, 0.5 Mm Gauge ( Only Supply ) 45.19.2 1 Pair, 0.5 Mm Gauge ( Only Labour ) 45.19.3 1 Pair, 0.5 Mm Gauge ( Composite ) 45.19.4 2 Pair, 0.5 Mm Gauge ( Only Supply ) 45.19.5 2 Pair, 0.5 Mm Gauge ( Only Labour ) 45.19.6 2 Pair, 0.5 Mm Gauge ( Composite ) 45.19.7 5 Pair, 0.5 Mm Guage ( Only Supply ) 45.19.8 5 Pair, 0.5 Mm Guage ( Only Labour ) 45.19.9 5 Pair, 0.5 Mm Guage ( Composite ) 45.19.10 Providing & Installation Of Analogue Telephone Instrument 45.19.11 Providing Testing Cord For Crone Block ( Only Supply ) 45.19.12 Providing Crone Tool ( Only Supply ) 45.19.13 Replacement Of Cord For Tele. Instrument, With Rj 11 Jack At Both Ends. ( Only Supply ) 45.19.14 Servicing / Repair Of Telephone Instrument ( Composite ) 45.19.15 Supply & Laying Of Cat-6 Cable Through Provided Casing-Capping, Pvc Conduit All As Directed By O-I-C, Es ( Only Supply ) 45.19.16 Supply & Laying Of Cat 6 Cable Through Provided Casing-Capping, Pvc Conduit All As Directed By O-I-C, Es ( Labour ) 45.19.17 Supply & Laying Of Cat 6 Cable Through Provided Casing-Capping, Pvc Conduit All As Directed By O-I-C, Es ( Composite ) 45.19.18 Providing & Installation Of Cordless Telephone Instrument 45.19.19 Providing & Installation Of Caller Id Telephone Instrument 45.19.23 Supply Of Camera Equivalent 1.3Mp / 2Mp Ip Ir Dome Camera 45.19.24 Supply Of Camera ( 2Mp ) Ip Ir Bullet Camera 45.19.27 Camera Turbo Hd720p Or Equivalent , Indoor Ir Turret 1.0 Megapixel Analogue Camera 45.19.28 Supply Of Crimping Tool 3 In 1 Modular Crimping Tool, Rj45, Rj11 Cat5e / Cat6 Lan Cutter With Cable Cutter 45.19.29 Sitc Of 8 Port Poe Network Switch’S, Gigabit Ethernet Web Smart Chassis In A 1U Form Factor With 24 X 10 / 100 / 1000 Poe Base-T Ports, 2 Fixed Sfp ( 1G ) With Internal Power Supply ( 192W Poe Budget ) . 45.19.30 Sitc Of 16 Port Poe Network Switch’S, Gigabit Ethernet Web Smart Chassis In A 1U Form Factor With 24 X 10 / 100 / 1000 Poe Base-T Ports, 2 Fixed Sfp ( 1G ) With Internal Power Supply ( 192W Poe Budget ) . 45.19.31 Sitc Of 24 Port Poe Network Switch’S, Gigabit Ethernet Web Smart Chassis In A 1U Form Factor With 24 X 10 / 100 / 1000 Poe Base-T Ports, 2 Fixed Sfp ( 1G ) With Internal Power Supply ( 192W Poe Budget ) . 45.19.32 Supply Of 8 Port Normal Switch Or Equivalent 45.19.33 Supply Of Cat 6 Patch Cord 01 Mtr 45.19.34 Supply Of Cat 6 Patch Cord 03 Mtr 46.1 Battery System Supply, Installation, Testing & Commissioning Of 2 Volt Batteries Suitable 150 Ah Lead Acid Battery Set And Buy Back Of Old Battery ( Only Supply ) 46.2 Supply, Installation, Testing & Commissioning Of 2 Volt Batteries Suitable To 150 Ah Lead Battery Set And Buy Back Of Old Battery. ( Only Labour ) 46.3 Supply, Installation, Testing & Commissioning Of 2 Volt Batteries Suitable To 150 Ah Lead Battery Set And Buy Back Of Old Battery. ( Composite ) 46.4 Supply, Installation, Testing & Commissioning Of 12 Volt Batteries Suitable To 150 Ah Lead Battery Set And Buy Back Of Old Battery. ( Only Supply ) 46.5 Supply, Installation, Testing & Commissioning Of 12 Volt Batteries Suitable To 150 Ah Lead Battery Set And Buy Back Of Old Battery. ( Only Labour ) 46.6 Supply, Installation, Testing & Commissioning Of 12 Volt Batteries Suitable To 150 Ah Lead Battery Set And Buy Back Of Old Battery. ( Composite ) 46.7 Supply, Installation, Testing & Commissioning Of 12 Volt Smf Batteries . ( Only Supply ) 46.8 Supply, Installation, Testing & Commissioning Of 12 Volt Smf Batteries . ( Only Labour ) 46.9 Supply, Installation, Testing & Commissioning Of 12 Volt Smf Batteries . ( Composite ) 46.10.A Supply, Installation, Testing & Commissioning Of 12 Volt, 7Ah Smf Batteries For Ups. ( Only Supply ) 46.11 Supply, Installation, Testing & Commissioning Of 12 Volt, 7Ah Smf Batteries For Ups.. ( Only Labour ) 46.12 Supply, Installation, Testing & Commissioning Of 12 Volt, 7Ah Smf Batteries For Ups. ( Composite ) 46.13 Supply, Installation, Testing & Commissioning Of 65 Ah Make Maintenance Free Sealed Batteries Having 2 Cells, Each Cell Of 12 V To Give Max. Voltage Of 24 V For Fire Alarm System ( Supply ) 46.14 Supply, Installation, Testing & Commissioning Of 65 Ah Make Maintenance Free Sealed Batteries Having 2 Cells, Each Cell Of 12 V To Give Max. Voltage Of 24 V For Fire Alarm System ( Labour ) 46.15 Supply, Installation, Testing & Commissioning Of 65 Ah Make Maintenance Free Sealed Batteries Having 2 Cells, Each Cell Of 12 V To Give Max. Voltage Of 24 V For Fire Alarm System ( Composite ) 46.16 Supply, Installation, Testing & Commissioning Of 180Ah Make Maintenance Free Lead Acid Batteries Having Give Max. Voltage Of 12 V For Dg Set And Buy Back Of Old Battery ( Only 46.17 Supply, Installation, Testing & Commissioning Of 180Ah Make Maintenance Free Lead Acid Batteries Having Give Max. Voltage Of 12 V For Dg Set And Buy Back Of Old Battery ( Only 46.18 Supply, Installation, Testing & Commissioning Of 180Ah Make Maintenance Free Lead Acid Batteries Having Give Max. Voltage Of 12 V For Dg Setand Buy Back Of Old Battery ( Composite ) 46.19 Supply, Installation, Testing & Commissioning Of 100 Ah Pulse Lite Batteries Having Give Voltage Of 12 V For Dg Set And Buy Back Of Old Battery ( Only Supply ) 46.20 Supply, Installation, Testing & Commissioning Of 100 Ah Pulse Lite Batteries Having Give Voltage Of 12 V For Dg Set And Buy Back Of Old Battery ( Only Labour ) 46.21 Supply, Installation, Testing & Commissioning Of 100 Ah Pulse Lite Batteries Having Give Voltage Of 12 V For Dg Set And Buy Back Of Old Battery ( Composite ) 46.22 Distilled Water For Batteries ( Lt. ) ( Only Supply ) 46.23 Battery Solution ( Litre ) ( Only Supply ) 46.24 Petroleum Jelly ( Kg ) ( Only Supply ) 46.25 Castrol Make Ap 3 Ball Bearing Grease ( Only Supply ) 46.26 Battery Cell Tester, 2 V Dc ( Only Supply ) 46.27 Battery For Emergency Tube Light ( Only Supply ) 46.28 Hydrometer For Battery Solution Checking ( Only Supply ) 46.29 Rechargeable Battery, 9 V ( For Mike Etc ) ( Only Supply ) 46.30.A Rechargeable Battery, 1.5 V ( Only Supply ) 46.31 Pencil Cell For A / C Remote ( Only Supply ) 46.32 Pencil Cell For Cordless Bell ( Only Supply ) 46.33 Pencil Cell For Urinal Sensor, Clock And General Use ( Only Supply ) 46.34 Charger For Rechargeable Batteries Of Best Quality ( Only Supply ) 46.35 Crc / Ctc Etc. For General Maintenance ( Only Supply ) 46.36 Steelgrip Pvc Insulation Tape ( Only Supply ) 46.37 Cutter Machine Blade ( Only Supply ) 46.38 Supply Of Battery Connetion Cords / Leads Having Lsuitable Lug / Clamp At The End Etc With Size Of Core / Wire To Connect The Battery To Ups / Chargers Etc. All As Per Instructions Of ( Only Supply ) 46.39 Supply Of 12 V / 6 Ah To 10Ah Range Maintenance Free / Sealed Rocket / / Amara Raja Or Other Equivalent Battery Suitable For Ups. Prior Approval For Make & Other Specification Is Required. ( Only Supply ) 46.40.A Supply, Installation, Testing & Commissioning Of 160Ah Make Maintenance Free Lead Acid Batteries Having Give Max. Voltage Of 12 V For Dg Set ( Only Supply ) 46.41 Supply, Installation, Testing & Commissioning Of 160Ah Make Maintenance Free Lead Acid Batteries Having Give Max. Voltage Of 12 V For Dg Set ( Only Labour ) 46.42 Supply, Installation, Testing & Commissioning Of 160Ah Make Maintenance Free Lead Acid Batteries Having Give Max. Voltage Of 12 V For Dg Set ( Composite ) 46.43 Supply, Installation, Testing & Commissioning Of 100 Ah Vrla Batteries Having Give Max. Voltage Of 30 V For Dg Set And Buy Back Of Old Battery ( Only Supply ) 46.44 Supply, Installation, Testing & Commissioning Of 100 Ah Vrla Batteries Having Give Max. Voltage Of 30 V For Dg Set And Buy Back Of Old Battery ( Only Labour ) 46.45 Supply, Installation, Testing & Commissioning Of 100 Ah Vrla Batteries Having Give Max. Voltage Of 30 V For Dg Set And Buy Back Of Old Battery ( Composite ) 46.46 Supply, Installation, Testing & Commissioning Of 200Ah Amaron Solar Smf Maintenance Free Lead Acid Batteries Having Give Max. Voltage Of 12 V For Solar Panel ( Only Supply ) 46.47 Supply, Installation, Testing & Commissioning Of 200Ah Amaron Solar Smf Maintenance Free Lead Acid Batteries Having Give Max. Voltage Of 12 V For Solar Panel ( Only Labour ) 46.48 Supply, Installation, Testing & Commissioning Of 200Ah Amaron Solar Smf Maintenance Free Lead Acid Batteries Having Give Max. Voltage Of 12 V For Solar Panel ( Composite ) 46.49 12Volt 26Ah Maintenance Free Battery ( Only Supply ) 46.50.A 12Volt 26Ah Maintenance Free Battery ( Only Labour ) 46.51 12Volt 26Ah Maintenance Free Battery ( Composite ) 46.52 12Volt 42Ah Maintenance Free Battery ( Only Supply ) 46.53 12Volt 42Ah Maintenance Free Battery ( Only Labour ) 46.54 12Volt 42Ah Maintenance Free Battery ( Composite ) 46.55 12Volt 7Ah Maintenance Free Battery ( Only Supply ) 46.56 12Volt 7Ah Maintenance Free Battery ( Only Labour ) 46.57 12Volt 7Ah Maintenance Free Battery ( Composite ) 46.58 12Volt 12Ah Maintenance Free Battery ( Only Supply ) 46.59 12Volt 12Ah Maintenance Free Battery ( Only Labour ) 46.60.A 12Volt 12Ah Maintenance Free Battery ( Composite ) 46.61 12Volt 7.5Ah Maintenance Free Battery ( Only Supply ) 46.62 12Volt 7.5Ah Maintenance Free Battery ( Only Labour ) 46.63 12Volt 7.5Ah Maintenance Free Battery ( Composite ) 47.00 The System Of Wiring Shall Consist Of Isi Marked Single Core, Pvc Insulated, Frls, 1100 Volt Grade, Stranded, Flexible Copper Conductor Wires As Per Is : 694 Amended Upto Date. 47.1 Copper Wires Pvc , Panel Wires For Interconnections. 1.5 Sq. Mm ( Only Supply ) 47.2 1.5 Sq. Mm ( Only Labour ) 47.3 1.5 Sq. Mm ( Composite ) 47.4.A 2.5 Sq. Mm ( Only Supply ) 47.5 2.5 Sq. Mm ( Only Labour ) 47.6 2.5 Sq. Mm ( Composite ) 47.7 4 Sq. Mm ( Only Supply ) 47.8 4 Sq. Mm ( Only Labour ) 47.9 4 Sq. Mm ( Composite ) 47.10.A 6 Sq. Mm ( Only Supply ) 47.11 6 Sq. Mm ( Only Labour ) 47.12 6 Sq. Mm ( Composite ) 47.13 10 Sq. Mm ( Only Supply ) 47.14 10 Sq. Mm ( Only Labour ) 47.15 10 Sq. Mm ( Composite ) 47.16 16 Sq. Mm ( Only Supply ) 47.17 16 Sq. Mm ( Only Labour ) 47.18 16 Sq. Mm ( Composite ) 47.19 25 Sq. Mm ( Only Supply ) 47.20.A 25 Sq. Mm ( Only Labour ) 47.21 25 Sq. Mm ( Composite ) 47.22 35 Sq. Mm ( Only Supply ) 47.23 35 Sq. Mm ( Only Labour ) 47.24 35 Sq. Mm ( Composite ) 47.25 50 Sq. Mm ( Only Supply ) 47.26 50 Sq. Mm ( Only Labour ) 47.27 50 Sq. Mm ( Composite ) 47.28 70 Sq. Mm ( Only Supply ) 47.29 70 Sq. Mm ( Only Labour ) 47.30.A 70 Sq. Mm ( Composite ) 47.30.1 95 Sq. Mm ( Only Supply ) 47.30.2 95 Sq. Mm ( Only Labour ) 47.30.3 95 Sq. Mm ( Composite ) 47.31 Connection Wire For Strip Heaters Along With Porcelain Balls Over It Etc. ( Only Supply ) 47.32 Connection Wire For Strip Heaters Along With Porcelain Balls Over It Etc. ( Only Labour ) 47.33 Connection Wire For Strip Heaters Along With Porcelain Balls Over It Etc. ( Composite ) 47.34 Porcelain Balls, Small Termination Insulator Etc For Strip Heaters / Other Any Type Of Heater, All As Directed By O-I-C, Es ( Only Supply ) ( One Pack ) 47.35 Porcelain Balls, Small Termination Insulator Etc For Strip Heaters / Other Any Type Of Heater, All As Directed By O-I-C, Es ( Only Labuor ) 47.36 Porcelain Balls, Small Termination Insulator Etc For Strip Heaters / Other Any Type Of Heater, All As Directed By O-I-C, Es ( Composite ) 47.37 Supply Of Various Kinds / Sizes Of Ms / Gi Bolts / Screws Etc As Per Requirment Etc All As Instructed By E-I-C. ( Only Supply ) 47.38 Supply Of Various Kinds / Sizes Of Brass Bolts / Screws Etc As Per Requirment Etc All As Instructed By E-I-C. ( Only Supply ) 47.39 Supply Of Various Kinds / Sizes Of Anchor Fastners As Per Requirment Etc All As Instructed By E-I-C. ( Only Supply ) 6 Mm 47.40 Supply Of Various Kinds / Sizes Of Anchor Fastners As Per Requirment Etc All As Instructed By E-I-C. ( Only Supply ) 8 Mm 47.41 Supply Of Various Kinds / Sizes Of Anchor Fastners As Per Requirment Etc All As Instructed By E-I-C. ( Only Supply ) 10 Mm 47.42 Supply Of Various Kinds / Sizes Of Anchor Fastners As Per Requirment Etc All As Instructed By E-I-C. ( Only Supply ) 12 Mm 47.43 Supply Of Verious Size Of Drill Bit 47.43.1 Drill Bit 3 / 16 Ms 47.43.2 Drill Bit 3 / 16 Concrete 47.43.3 Drill Bit 3 / 16 Hammering 47.43.4 Drill Bit 1 / 8 Ms 47.43.5 Drill Bit Wooden Set 47.43.6 Drill Bit Concrete Set 47.43.7 Drill Bit Roraty Hammer 4Mm 47.43.8 Drill Bit Roraty Hammer 8 Mm 47.43.9 Drill Bit Roraty Hammer 10 Mm 47.43.10 Drill Bit Roraty Hammer 12 Mm 47.43.11 Drill Machine Rotary Hammering Type 47.43.12 Drill Pair Set Mm 47.43.13 Drill Pair Set Inches 47.43.14 Mini Hacksaw Blade Taparia Make 47.43.15 Hacksaw Blade Big Size 47.43.16 Mini Hacksaw Blade Taparia Make With Frame 47.43.17 Hacksaw Blade Big Size With Frame 47.43.18 Hole Saw Cutter Ms 16Mm To 32Mm 47.43.19 Hole Saw Cutter Ms 32Mm To 75Mm 47.43.20 Hole Saw Cutter Ms 75Mm To 150Mm 47.43.21 Hole Saw Cutter Ms 150Mm To 300Mm 47.43.22 Pvc Grip Rawal Plastic Wall Plug Per Pkt Qty 200Each 47.43.23 Grinding Wheel Blade 48.1 Oil Filtration For 2 Mva Transformer 48.2 Oil Filtration For 4 / 4.5 Mva Transformer 48.3 Supply & Topping Up Of Transformer Oil 48.4 Yearly Servicing For Air Circuit Breakers, 800A , 1000 A / 1250 A / 1600 A / 2000A / 2500A / 3200 A, 440 V, Mpact, Ge Make , Abb , Sterling Existing Make , Testing Of Breakers , All Type Test To Be Carry Out , Greasing Activity, And Complete Servicing. 48.5 Yearly Servicing Of Circuit Breakers 48.5.1 33 Kv Sf6 Circuit Breaker 48.5.2 11 Kv Sf6 Circuit Breaker 48.5.3 33Kv Vacuum Circuit Breaker 48.5.4 11Kv Vacuum Circuit Breaker 48.6 Testing & Calibration Of All Types Of Relays, Existing Makes Relays In Ht Panel, Lt Panel 48.6.1 Cdg 31 / Cdag 51 48.6.2 Vajh / Vajc 48.6.3 Vaa / Vdg 48.6.4 Vtt 48.6.5 Vagm / Cag / Ccum / Ycgf / Cdv / Mfvum 48.6.6 Vax 48.6.7 Apfc Relay 48.6.8 Tcs Relay Ber 2 / Ber1 48.6.9 Feeder Protection Relay Bcf1 48.6.10 Lock Out Relay 86 48.6.11 Restricted Earthfault Relay 48.6.12 Reverse Power Relay 48.6.13 Earthfault Relay 48.6.14 Calibration Of Multimeter , Clamp Meter And Megger, Earth Tester 48.7.1 Annual Servicing For Transformers 2.0 Mva 48.7.2 Annual Servicing For Transformers 4.5 / 4.0 Mva 48.8 Cable Fault Detecting / Fault Finding For All Sizes Of Cables. 48.9 Supply & Installation Of Required Size Of Teak Wood Bushes For Sealing The Existing Hume Pipe End Wherever Cable Passes Through With Bituminous Compound Filling Etc. All As Per Instructions Of E-I-C. ( Only Supply ) 48.10.A Supply & Installation Of Required Size Of Teak Wood Bushes For Sealing The Existing Hume Pipe End Wherever Cable Passes Through With Bituminous Compound Filling Etc. All As Per Instructions Of E-I-C. ( Only Labour ) 48.11 Supply & Installation Of Required Size Of Teak Wood Bushes For Sealing The Existing Hume Pipe End Wherever Cable Passes Through With Bituminous Compound Filling Etc. All As Per Instructions Of E-I-C. ( Composite ) 48.12 Testing & Calibration Of All Types Of Energy Meter 48.13 Supply And Erecting Approved Make 33 Kv Fuse Barrel With Metal Fittings. ( Only Supply ) 48.14 Supply And Erecting Approved Make 33 Kv Fuse Barrel With Metal Fittings. ( Only Labour ) 48.15 Supply And Erecting Approved Make 33 Kv Fuse Barrel With Metal Fittings. ( Composite ) 48.16 Providing Pair Of Duly Tested Rubber Hand Glows Suitable For Working On 33Kv Supply ( Only Supply ) 48.17 Supplying And Fixing Of Pvc Synthetic Elastomer Electrically Insulating Mat With Class-C Insulation Confirming To Is:15652-2006 Having 3Mm Thickness Up To 33 Kv ( Only Supply ) 48.18 Supplying And Fixing Of Pvc Synthetic Elastomer Electrically Insulating Mat With Class-C Insulation Confirming To Is:15652-2006 Having 3Mm Thickness Up To 33 Kv ( Only Labour ) 48.19 Supplying And Fixing Of Pvc Synthetic Elastomer Electrically Insulating Mat With Class-C Insulation Confirming To Is:15652-2006 Having 3Mm Thickness Up To 33 Kv ( Composite ) 48.20.A Supplying And Fixing Of Pvc Synthetic Elastomer Electrically Insulating Mat With Class-B Insulation Confirming To Is:15652-2006 Having 2.5Mm Thickness Up To 11 Kv ( Only Supply ) 48.21 Supplying And Fixing Of Pvc Synthetic Elastomer Electrically Insulating Mat With Class-B Insulation Confirming To Is:15652-2006 Having 2.5Mm Thickness Up To 11 Kv ( Only Labour ) 48.22 Supplying And Fixing Of Pvc Synthetic Elastomer Electrically Insulating Mat With Class-B Insulation Confirming To Is:15652-2006 Having 2.5Mm Thickness Up To 11 Kv ( Composite ) 48.23 Supplying And Fixing Of Pvc Synthetic Elastomer Electrically Insulating Mat With Class-A Insulation Confirming To Is:15652-2006 Having 2.0Mm Thickness Up To 3.3 Kv ( Only Supply ) 48.24 Supplying And Fixing Of Pvc Synthetic Elastomer Electrically Insulating Mat With Class-C Insulation Confirming To Is:15652-2006 Having 2.0Mm Thickness Up To 3.3 Kv ( Only Labour ) 48.25 Supplying And Fixing Of Pvc Synthetic Elastomer Electrically Insulating Mat With Class-C Insulation Confirming To Is:15652-2006 Having 2.0Mm Thickness Up To 3.3 Kv ( Composite ) 48.26 Supplying Standerd First Aid Box With Necessary Antiseptic Cream, Medicine For Use On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Use Bandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution Etc. ( Only Supply ) 48.27 Testing And Calibration Of Energy Meters. 48.28 Supply And Fixing Of 33Kv, Epoxy Type Insulator For Bus Bar Support ( Only Supply ) 48.29 Supply And Fixing Of 33Kv, Epoxy Type Insulator For Bus Bar Support ( Only Labour ) 48.30.A Supply And Fixing Of 33Kv, Epoxy Type Insulator For Bus Bar Support ( Composite ) 49.1 Pa Address System Male –Female, All Kinds Of Audio / Video Pins ( Only Supply ) ( Pair ) 49.2 Male–Female, All Kinds Of Audio / Video Pins ( Only Labour ) ( Pair ) 49.3 Male –Female, All Kinds Of Audio / Video Pins ( Composite ) ( Pair ) 49.4 2 Core Multistranded Double Sheathed Flexible Cable For Speaker & Laying In Casing-Capping ( Only Supply ) 49.5 2 Core Multistranded Double Sheathed Flexible Cable For Speaker & Laying In Casing-Capping ( Only Labour ) 49.6 2 Core Multistranded Double Sheathed Flexible Cable For Speaker & Laying In Casing-Capping ( Composite ) 49.7 2 Core Multistranded Double Sheathed Flexible Cable For Speaker & Laying In Pvc 25Mm Conduit ( Only Supply ) 49.8 2 Core Multistranded Double Sheathed Flexible Cable For Speaker & Laying In Pvc 25Mm Conduit ( Only Labour ) 49.9 2 Core Multistranded Double Sheathed Flexible Cable For Speaker & Laying In Pvc 25Mm Conduit ( Composite ) 49.16 Cable Tie Nylon 6 / 6 – Uv Stabilized Uv Stabilized Nylon 6 / 6 Use In Continuous Or Extended Exposure To Outdoor Sunlight. Weather Resistant Grade, Enduring Additional Ultraviolet ( Uv ) Light. 49.16.1 As Per 49.16 For 100 Mm Size Pkt For 100 Nos ( Only Supply ) 49.16.2 As Per 49.16 For 200 Mm Size Pkt For 100 Nos ( Only Supply ) 49.16.3 As Per 49.16 For 300 Mm Size Pkt For 100 Nos ( Only Supply ) 49.17 Multimeter Make Mecho , 415Volt ( Only Supply ) 49.18 Clamp Meter Mecho Make , 415Volt ( Only Supply ) 49.19 Hand Driven Insulation Tester 500Volt ( Only Supply ) 49.20.A Meggar Digital Insulation Tester 500Volt ( Only Supply ) 49.21 Supply, Installation, Laying And Connection Of G.I. Perforated & Ladder Type Cable Tray With Bends, Tees, Clamps And Couplers For Fixing Of Cable With Suitable Ms Structure And Anchor Fastner For Supporting And Necessary Hardware With Necessary Welding Has To Be Done To Complete The Job From Isa / Ismc / Plate. The Job Also Includes To Paint The Structure With Two Coats Of Red Oxide And Two Coats Color Of Enamel Paint As Approved . All Material Shall Be Hot Dip Galvanised As Per Is ( 816 G / M2 ) And Specifications. The Structural Steel Supports For The Trays Are To Be Provided At Every 1 Mtrs. As Per Technical Specifications. 49.21.1 600Mm ( W ) X 75Mm ( H ) X 2Mm ( Thk ) Ladder Type Tray 49.21.2 300Mm ( W ) X 75Mm ( H ) X 2Mm ( Thk ) Ladder Type Tray 49.21.3 150Mm ( W ) X 75Mm ( H ) X 2Mm ( Thk ) Ladder Type Tray 49.21.4 150Mm ( W ) X 75Mm ( H ) X 2Mm ( Thk ) Perforated Type Tray 49.22 Fiber Accessories 49.22.1 Supply Of 12 Core , 9 / 125 Micron Single Mode Os2 - Corrugated Steel Tape Armoured Loose Tube Gel Filled Fiber Optical Cable, All As Per Instruction Of E-I-C And As Directed By Oic, Es ( Only Supply ) 49.22.2 Supply Of 12 Core , 9 / 125 Micron Single Mode Os2 - Corrugated Steel Tape Armoured Loose Tube Gel Filled Fiber Optical Cable, All As Per Instruction Of E-I-C And As Directed By Oic, Es ( Composite ) 49.22.3 Supply Of Os2 Fully Loaded Fiber Tray Liu, Which Includes Adaptors , Pigtails, Splice Protectors Etc For The Termination Of 12 Core Single Mode Fiber Cable. ( Only Supply ) 49.22.4 Supply Of Os2 Fully Loaded Fiber Tray Liu, Which Includes Adaptors , Pigtails, Splice Protectors Etc For The Termination Of 12 Core Single Mode Fiber Cable. ( Composite ) 49.22.5 Supply Of Sm Duplex Type 03 Mtr Patch Cord , Om2 , Lc-Lc, Lc - Sc Any Combination As Required ( Only Supply ) 49.22.6 Supply Of Sm Duplex Type 10 Mtr Patch Cord , Om2 , Lc-Lc, Lc - Sc Any Combination As Required ( Only Supply ) 49.22.7 Supply Of Hdmi Cable For Monitor Including End Connectors 49.22.8 Fiber Core Splicing Charges Per Core Composite Work

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 03-05-2023 Date Corrigendum Date 10-05-2023
2 25-04-2023 Date Extension Date 03-05-2023

Key Value

Document Fees
Refer document
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail