}

Providing Electricity Supply As Per Prescribed Roster In The Newly Created Nagar Panchayat, Pisawa Under The Area Of ​​Electricity Distribution Division-Pancham, Khair, As Per Desired Work Specification, khair-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited has published Providing Electricity Supply As Per Prescribed Roster In The Newly Created Nagar Panchayat, Pisawa Under The Area Of ​​Electricity Distribution Division-Pancham, Khair, As Per Desired Work Specification. Submission Date for this Tender is 31-03-2023. Wall Construction Tenders in khair Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37011780
Providing Electricity Supply As Per Prescribed Roster In The Newly Created Nagar Panchayat, Pisawa Under The Area Of ​​Electricity Distribution Division-Pancham, Khair, As Per Desired Work Specification
Open Tender
NCB
Uttar Pradesh
Khair
31-03-2023

Tender Details

Providing Electricity Supply As Per Prescribed Roster In The Newly Created Nagar Panchayat, Pisawa Under The Area Of ​​Electricity Distribution Division-Pancham, Khair, As Per Desired Work Specification- 1 St Pole 11 Mtr. Long 2 Pcc Pole 8.5 Mtr. Long 3 Stone Pad ( 300X300x75 Mm ) 4 Top Channel ( 125X65x2240mm ) 5 Dropper Channel ( 100X50x2028mm ) 6 V-Type Steel Cross Arm With Clamp 7 11 Kv Pin Insulator With Pin Complete 8 11 Kv Disc Insulator With Fitting 9 M.S. T-Off Channel With Clamp B&N ( 100X50x1300mm ) 10 F-Bracket For Fitting Top Channel 11 Holding Clamp For Tpmo & Fuse Set With Bolt Nut 12 Danger Board With Clamp N&B 13 Stay Complete 14 Earthing Complete 15 Tpmo Complete 16 Distribution Box With Clamp 17 Abc 3X120 + 1X95 + 1X16 Sq.Mm. 18 P.G. Clamp 19 End Clamp 20 Eye Hook With Clamp For Pcc Pole With N&B 21 Pearsing Connector 22 Bolt, Nut & Washers 23 11 / 0.4 Kv 400 Kva Transformer 24 11 / 0.4 Kv 250 Kva Transformer 25 10 Mva 33 / 11 Kv Power Transformer With Accessories 26 Lt Xle Cable Al. 1X400 Sq.Mm. 27 Lt Xle Cable Al. 1 X 240 Sq.Mm. 28 Lt Xle Cable Al. 3.5 X 240 Sq.Mm. 29 Cable Al. 3X300 Sq.Mm. Xlpe Cable 11 Kv 30 Cable Al. 3X185 Sq.Mm. Xlpe Cable 11 Kv 31 11 Kv Vcb I / C Ctr 600 / 300 / 5A 350 Mva, 24 Volt 32 11 Kv Vcb O / G Ctr 200 / 100 / 5A 350 Mva 33 11 Kv Ct / Pt Metering Pole Mounted Unit 34 11 Kv Cable Jointing Kit Indoor 3X300 Sq.Mm. 35 11 Kv Cable Jointing Kit Outdoor3x300 Sq.Mm. 36 11 Kv Cable Jointing Kit Outdoor3x185 Sq.Mm. 37 11 Kv Cable Jointing Kit Indoor3x185 Sq.Mm. 38 11 Kv Fuse Set 39 Phase Wire Acsr Weasel Conductor 40 Phase Wire Acsr Dog Conductor 41 Body And Neutral Earthing Of Following L.T. Distribution Transformers Installed By Digging Of Pit Up To Water Level Depth ( Approx. 100’ ) And Then Inserting1-1 / 4 Dia G.I. Pipe Of B Grade, Conforming To The Requirement Of Is Specification And Then Connecting The Top Of The Inserted Pipe And Transformer Body Through Gi Strip Of Size 50X6 Mm With The Help Of Nut And Bolt Or Through Gas Welding, As Per Direction Of Supervising Engineer Including The Cost Of Arrangement Of All Material, Labourer, T&P, Carrier Etc. Required For Proper Completion Of Work. 42 10 Mva Power Transformer 43 11 / 0.4 Kv 400 Kva Transformer 44 11 / 0.4 Kv 250 Kva Transformer 45 11 Kv Vcb 46 Complete Chemical Earthing Of 33 Kv Vcb By Digging Pits 6” Dia Upto 3 Mtr. Deep Including Chemical Filled Pipe In Between ( Pipe-In-Pipe ) Isi Mark B Grade & Connecting With G.I Strip Of Size 50Mm X 6Mm With Neutral / Body Of 11 / 0.4 Kv Distribution Transformer To Above Pipe-In-Pipe ( Pip ) And Filling Of Chemical Crystalline Conductive Mixture Containing Highly Conductive Material Around The ( Pipe-In-Pipe ) Up To 3 Mtr. Including Making Of Chamber At The Top Of The Earthing. Other Details Are As Below:-1. Earth Pipe Material – Mild Steel, Galvanized.2-Main Electrode Diameter – 42.4Mm.3-Auxiliary Electrode Pipe, Diameter – 76Mm. 4-Wall Thickness Of Main Electrode: - 2.6Mm.5-Wall Thickness Of Auxiliary Hole: - 3.2Mm.6- Length Of Earthing Electrode ( Pip ) :- 3 Meter. 47 Construction Of Following Transformer Of Plinth Of Size 5’X5x4’ Above Ground Level And One Ft. Below The Ground Level Of 9”. After Excavation Of 4” Earth, Brick Ballast Shall Be Provided And Rammering Will Be Done Properly After That A Retaining Wall Of 9” Width By First Class Brick In Ratio 1:4 Of Cement And Sand Shall Be Made. The Earth Shall Be Filled Up To One Ft. Below The Top Of The Plinth. After This Brick Ballast Shall Be Provided Up To 6” From The Earth Level And Proper Rammering Shall Be Done. One No. Jall Of 12 Mm M.S. Tor Shall Be Fixed In The Hollow Of Plinth And One Ft. Thick Rcc In Ratio Of Cement, Sand And Stone Ballast Shall Be Laid On The Top Of The Plinth. The 12 Mm Thick Plastering Shall Be Done All Around The Plinth In 1:4 Ratio Of Cement And Sand. The Contractor Shall Be Responsible To Complete The Work As Per Direction Of Supervising Engineer. It Including The Cost Of All Material, Labour T&P, Carrier Etc. Required For Proper Completion Of Work. 48 11 / 0.4 Kv 400 Kva Transformer 49 11 / 0.4 Kv 250 Kva Transformer 50 Fabrication & Erection Of Fencing And Construction Of Retaining Wall Aroundfollowing Capacity T / Fthe Complete 11 / 0.4 Kv Substation Shall Be Provided With Two Meter Height Fencing And Retaining Wall Around The Substation. One No. Gate With Proper Locking Arrangement For Entry Of Personnel Shall Also Be Provided. The Fencing Shall Be Made Of 50X25 Mm X10 Swg Rectangular Welded Mesh Of Wire Mesh In Length. Wire Mesh Shall Be Fixed On Panels Made Of 50X50x6 Mm M.S. Angle. The Wire Mesh On Panels Will Be Supported By 25X3 Mm M.S. Flat On All The Bracings Diagonally And 50X6 M.S. Flat Horizontally At The Center Of The Panel. The Panel Will Be Joined By Bolts & Nuts Of Appropriate Size With Each Other And On The Main Support On Corners Including Supply Of All Material, Labour, Carrier And T & P Etc. Required For Proper Completion Of Work. The Painting Of Complete Fencing Shall Also Be Done With One Coat Of Red Oxide Primer And Two Coat Of Synthetic Green Paint. For Construction Of Retaining Wall Around The Fencing, Excavation Of Earth Shall Be Done In Foundation In Ordinary Soil Including Disposal Of Surplus Earth At Some Suitable Distance. The Dimension Of Excavation Shall Be 1M Wide, 0.45 M Deep And Suitable Length As Per Wire Mesh. After Excavation Of Earth A Cement Concreted Pad Shall Be Laid In Foundation. Concreting Shall Be Done With Ist Class Brick Ballast, Coarse Sand And Cement In Proportion Of 8:4:1. First Class Brickwork Shall Also Be Done In Foundation And Super Structure In 1:6 Cement And Coarse Sand Including Necessary Cutting And Moulding Of Bricks In Foundation Depth Of Wall 0.30 M, Thickness Of Wall 0.35 M & Superstructure Brick Work Thickness Of Wall 0.23 M & Depths 0.30 M Including Supply Of All Material, Labour, Carrier And T & P Etc. Required For Proper Completion Of Work. 51 11 / 0.4 Kv 400 Kva Transformer 52 11 / 0.4 Kv 250 Kva Transformer 53 Demounting & Carriage Of Following Capacity Transformer Due To Overloaded Including The Work Of Its Loading & Unloading, Dragging Etc. And Also Including The Cost Of Labour And T&P Etc. Required For Proper Completion Of Work. 54 11 / 0.4 Kv 100 Kva Transformer 55 11 / 0.4 Kv 250 Kva Transformer 56 11 / 0.4 Kv 63 Kva Transformer 57 11 / 0.4 Kv 25 Kva Transformer 58 08 Mva 33 / 11 Kv Power Transformer With Accessories 59 Dismantling And Removal Of Existing Conductor / Cable / Gi Wire From The Various Area Preparing Their Coils And Then Stacking In The Respective Je’S ( Store ) As Per Direction Of Supervising Engineer. It Includes The Work Of Cartage, Cost Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work. 60 Abc Lt 1X16 + 1X25 Sq.Mm. 61 Acsr Weasel Conductor 62 Concreating Of Pole 63 Concreating Of Stay 64 Guarding Of Old 11 Kv Line By Laying Two Nos. Gi Wire Parallel And Fixing Of Lacings ( Tilli ) At A Distance At 2-3 Mtr. As Per Respo Manual And Also Including The Cost Of Arragement Of Labour, T & P Etc. Required For Proper Completion Of Work. 65 Safe Carriage Of Old Line Material Viz. Conductor, G.I. Earth Wire, Abc Conductor, Cross Arm, Angle, Channel, Insulators, Clamps & Other Line Material From Any Other Place Or From Site Of Work To The Work Of Its Loading & Unloading At The Respective Ends Including The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. 66 Dismanteling Of Old Damaged 11 Kv Vcbs After Opening Its 11 Kv Cable Connection Removing Earthing Bus Bar Cts And Taking It Out Side Switch Yard.The Work Of Cartage, Cost Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work.

Key Value

Document Fees
INR 5900 /-
EMD
INR 326000.0 /-
Tender Value
INR 3.25 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail