| 1 | Dismantling roofs with care including stacking of serviceable material and disposal of unserviceable material with in 50 Mtr. lead for : Stone slab roofing complete with lime dhar and kharanja. |
| 2 | Dismantling stone rubble masonry including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. In Cement mortar. |
| 3 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 4 | Dismantling of flooring with care including stacking of servceable material and diposal of unserviceable material with in 50 Mtr. Lead for Cement concrete flooring. |
| 5 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 4: 8 or leaner mix. |
| 6 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 7 | Carriage of Building Rubbish Stone metal (Grit and ballast etc.) lead upto 5km. |
| 8 | Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering All up to plinth level IS 456-2000: 1:3:6 (1Cement :3 Course Sand :6 Graded stone aggregate 20 mm nominal size |
| 9 | Random Rubble stone masonary for foundation and plinth in Cement Sand Mortar above 30 Cm. thick wall IS 1597 (Part-I) 1992 in : Cement Sand Mortar 1:6 (1-Cement:6-Sand). |
| 10 | Random Rubble stone masonary for superstructure above plinth level one storey height above 30 Cm. thick walls IS 1597 (Part-I) 1992 in :Cement Sand Mortar 1:6 (1-Cement:6-Sand). |
| 11 | Pillar masonry including bed plates as per specifications.Bed plate to be paid separately. |
| 12 | Extra for facing as per design and detailed specifications IS 1597 (Part-II) 1992 including additional cost of stonesover item No. 6.1 & 6.2 for : Course rubble facing Second Sort. |
| 13 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns, etc. up to plinth level. |
| 14 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members andremoval of formwork for superstructure up to 4.5 mtr aboveplinth,for: Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands , coping, bed plates, anchor blocks, sills, chhajjas lintel, beam etc. |
| 15 | Providing and laying in position specified grade of reinforced cement concrete including curing compaction finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement.All work up to plinth levelIS 456-2000: 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size) |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs, girders having slopes up to 15o, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases, up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good and joints excluding the cost of centering, shuttering and reinforcement IS 456-2000: with 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size). |
| 17 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. Thermo Mechanically treated bars |
| 18 | Marble stone flooring table rubbed, 18-20 mm thick over 20 mm (Av.) thick base of CM 1:4 (1-Cement:4-coarse sand) jointing with white cement mortar 1:2 (1-White cement:2-marble dust) with pigment to match the shade of the marble slab including grinding rubbing and polishing complete IS 1130-1969. Rajnagar 2nd quality with light spots and streaks.Size upto 1501 to 3600 Cm2 |
| 19 | Grading roof water proofing treatment with : Cement concrete 1:2:4 (1-Cement:2-coarse sand :4-graded stone aggregate 20mm nominal size). |
| 20 | Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering All up to plinth level IS 456-2000: 1:2:4 (1Cement :2 Course Sand 4 Graded stone aggregate 20 mm nominal size) |
| 21 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished:20 mm thick. |
| 22 | Plaster on new surface on ceiling in cement sand mortar 1:4 including raking of joints etc. complete fine finish:12 mm thick. |
| 23 | Supply and fixing Jodhpur sand stone Machine cut Dash, Coping,sill,lintel fixed in cement sand mortar 1:4.9 cm (3.5\") thick |
| 24 | Supplying and fixing stone liri in CM 1:4 work facing with proper projection and chiesel dressing of edges of stone two line dressing of building corners, jambs etc. including uniform joints using aluminium square section of size 12 mm to 15 mm as per requirement of course and width of stone not less than 12 Cm., with requisitenumber headers (minimum length of stone 0.9 M) 6 cm. to 9 Cm. thick. |
| 25 | Add extra for 7 to 10 cm. thick courses. |
| 26 | Supplying and fixing Jodhpur machine cut stone Kadau 19cm (7.5\")hight in CM 1:4 with rock facing with proper projection and machine cut edges of stone, two line dressing of building corners, jambs etc. including uniform joints using aluminium square section of size 12 mm to 15 mm as per requirement of course and width of stone not less than 12 Cm., with reqisite humber headers (minimum length of sotne 0.9 M). |
| 27 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete |
| 28 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Three or more coats). |
| 29 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 30 | Providing and laying 20 to 25 mm size glazed tiles pieces for rooof treatment having colour and shade as approved by the Engineer incharge over 25 mm thick layer of cement mortar mix 1:4 with application of cement slurry including finishing of joints with ordinary cement and curing etc. complete in all respect. Washing with acid. |
| 31 | Providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design. |
| 32 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:3:6 (1-Cement:3-coarse sand:6-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 33 | Providing & fixing MS sheet single leaf door shutters in angle iron frame 35x35x5 mm suitablly diagonally braced with 25x3mm flat ironabove and below lock rail of size 50x5 mm beading extra includingall fittings, as per direction of Engineer incharge but excluding cost of chokhats including two coats of anti corrositve red oxide primer panit. MS sheet 22 SWG |
| 34 | Add extra for double leaf shuttters |
| 35 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 36 | Providing and fixing Square bars or other flat welded to window, ventilators etc. |
| 37 | Providing & fixing anodizing alumium work (Anodizing to be got done from approved Anodizer) for doors, windows, ventilators and partition with extruded built up standard tubular and other sections of approved make confirming to IS : 733 and IS : 1285 anodised transparent 81 dyed to required shade according to IS : 1868 (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gas at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required inlcuding cleat angle Aluminum snap beading for glazing/paneling, C.P. Brass/ Stainless Steel screws, Al. Tower bolt & Al. handle & Al. Aldrop etc. all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and peneling to be paid for separately).For Fixed portion |
| 38 | For shutters of doors, windows & ventilators incl. providing and fixing hinges/ rollers etc. and making provision for fixing of fittings wherever reqd. (lockes shall be paid for separately). |
| 39 | Providing and Fixing 12mm thick prelaminated three layer medium density (exterior grade) particle board Grade-I, Type-II confirming to IS 12823 bonded formaldehyde synthetic resin of approved brand and manufacture in paneling fixed in aluminium doors, windows/ stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
| 40 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVS/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (Cost. of aluminium snap beading shall be paid in basic item.) With glass panes of 5.0mm thickness (weight not less than 13.75 Kg/Sqm) as per IS : 2835 |
| 41 | P&F expanded grill made of anodised aluminium as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminium window/ vent with reqd. screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. |
| 42 | Providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. |
| 43 | Painting with enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work. |
| 44 | Deep groove pointing on stone masonry in white cement sand mortar (1:3) with colour pigment of approved shade for all type of masonry incl. racking of joint as per specification complete in all respect. |
| 45 | Supply & Fixing ofone side polished Black granite/ White Marble stone 20 mm thick of size 3\" x 2 \" with engraved and gold colour painted letters (up to 200 letters) & border as per direction of engineer - in charge on existing pedestals including transportation |
| 46 | Brick masonary in foundation and plinth with bricks of class designation 75 mm. IS 2212-1991 in : Cement Sand Mortar 1:6 (1-Cement:6-coarse sand). Add extra over item No. 5.1 for brick work in superstructure up to third storey IS 1077-1986. |
| 47 | PART-B( SANITORY WORK) |
| 48 | Providing and fixing Ist quality standard White Ivory Glazed Tiles ISI marked [IS:13753] of size 300mm x 200mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster). Category-I. |
| 49 | Providing and fixing Ist quality MAT finished ceremic tile size 300x300mm confirming to IS : 13753 colour such as white, grey, ivory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slsurry including nicely finished joints using water proof joint filler power and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster). |
| 50 | P & F CPVC Pipes in SDR 11 (Internal work) with CPVC fittings (IS:15778 Mark)including cutting and making good the walls and floors : Exposed on Wall |
| 51 | (a) 25mm dia |
| 52 | ( b)20mm dia |
| 53 | P & F Indian type white glazed vitreous china Ist quality W.C. orissa pan (IS:2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor : Size 580x440 mm. |
| 54 | P & FLowlevelflushingCisternof 10 litters capacity (IS:2556 mark)of approved make with completefittingsC.I. brackets dulypainted,brassballcock with ball, (IS :1703 Mark)complete including cuttingandmakinggood thewall PVC with PVC bend as per IS:7231 |
| 55 | P&F water closet seat covers with brass hinges complete Solid PVC (ISI marked) grade-I white for EWC. |
| 56 | P & F W VC wash basin (1st quality, IS : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15mm C.P. Pillar cock (IS : 8934 Mark) & 32 mm C.P. brass waste coupling pipe complete including cutting & making with the good wall size 510mm x 400mm |
| 57 | P&F Bib Cock (IS:8931 Mark), Superior quality of approved make: C.P. Brass bib cock 15mm. norminal bore |
| 58 | P&F StopCock(IS:8931Mark), Superior quality andof approved make: C.P Brass Concealed Stop Cock 15mm |
| 59 | P&FInletConnection (Angle,Valves) Superior quality, of approved make for Wash basin, Gyser etc.C.P. Inlet connection 15mm. brass (IS 8931 marked) |
| 60 | P&FFull-wayValve (IS:778Mark)or wheel Valve of approved make: |
| 61 | (a) Gun-metal 25mm nominal bore |
| 62 | (b) Gun-metal 15mm nominal bore |
| 63 | P & F PVC storage Tank confirming to (IS : 12701/89) Standards of approved make with cover, 25mm dia 1M long G.I. over flow pipe & 25cm. Long wash out pipe with plug & socket. Including making connection etc. complete of approved design 1000 litres capacity. |
| 64 | P&F Ball Cock (IS:1703 Mark) with Rod & P.V.C. Ball complete: Brass wt.400 gm. 15mm. |
| 65 | P&F Grating of approved quality/make. C.P brass with Light & superior quality size 125 mm dia. |
| 66 | P & F rigid PVC pipes (IS : 4985 Mark) class II (4kg./cm2) approved quality/make including jointing the pipe with solvent cement rubber ring and lubricant |
| 67 | (a) 110 mm dia |
| 68 | Construction of chamber in all type of soil with 300 mm thick masonry in Cm 1:6 m 100mm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.-do- size 450 x 450mm upto depth of 0.5m & 15Kg CI cover with frame |
| 69 | P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (large) or half stall size 590x375x390 mm. URS-WHT-13263 Urinal with Fixing Accessories, with sensor OR ITS EQUIVALENT as approved by E.I.C |
| 70 | P & F W.V.C. Urinal Partition plate of approved standard make of size 630x315 mm including making good the wall. |
| 71 | PART (C) ELECTRIFICATION WORK |
| 72 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 73 | Short point (up to 3 mtr.) |
| 74 | Medium point (up to 6 mtr.) |
| 75 | Long point(up to 10 mtr.) |
| 76 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 77 | Short point (up to 3 mtr.) |
| 78 | Medium point (up to 6 mtr.) |
| 79 | Long point(up to 10 mtr..) |
| 80 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 40 Arating |
| 81 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Metal door (single phase) IK-09 and IP-43 with Metal end box 8 Way (8+2) |
| 82 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 1 x 1.5 sq.mm |
| 83 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 84 | 2 x 2.5 sq.mm |
| 85 | 3 x 2.5 sq.mm |
| 86 | 3 x 6.0 sq. mm. |
| 87 | S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along withISI marked (IS:14768 P-II 2003) accessories inrecessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required includingcutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 25 mm |
| 88 | Providing & Fixing of IS 11037:1984marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 89 | P & F 16mm M.S. Fan clamps of standard shap & size in RCC slab including cutting chase and making good and paintings exposed portion at the clamps complee in new roofs. |
| 90 | Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy = 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.=0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing |
| 91 | Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |