Supply Of Equipment / Material , Design, Erection, Testing & Commissioning For Sop To Jsv, Lwsst / Well At Minjgran By Prov. 11 / .4 Kv 63 Kva S / Stn.A / W 11 Kv Ht Section Nurpur Under Esd Nurpur Ed Nurpur ( T.S. No. 102 / 22-23 ) ( Ii ) Tender For Supply Of Equipment / Material , Design, Erection, Testing & Commissioning For Sop To Lwss Chhatroli By Prov. 11 / .4 Kv 63 Kva S / Stn. At Chhatroli ( Batu-Ka-Nalah ) A / W 11 Kv Htlinesection Jassure Under Esd Nurpur Ed Nurpur ( T.S. No. 101 / 22-23 ) --- 1 Supply Part Of 11 / .4 Kv 63 Kva Distribution Sub Station 2 11 / .4 Kv 63Kva Dtr ( Rec Sep. Ord 11 / 1976 3 Prov. St Polepole 9 Mtr. Long W / L 200 Kgs 4 Muff For Steel Tubular Pole With Concrete Filling 5 X-Arm: [ Channel Iron ( 100X50x5 Mm ) , Length : 2800 Mm X 2 Nos ] For Incomer Line 6 Ms A.I. ( 50X50x6 Mm ) , Length: 2800 Mm X ( 1 Nos For LaS ) 7 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length : 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch 8 X-Arm: [ Channel Iron ( 100X50x6 Mm ) , Length : 2800 Mm X 2 Nos ] For Transformer Bed 9 X-Arm [ Channel Iron ( 100X50x6 Mm ) , Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer ] 10 Ms A.I. ( 50X50x6 Mm ) , Length: ( 2800 Mm ) X 2 No. 11 Ms Angle Iron ( 35X35x5 Mm ) , Length : 460 Mm X 2 Nos 12 Ms A.I. ( 50X50x6 Mm ) , Length: ( 950 Mm ) X 2 Nos. Of Bed Knee Bracing 13 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 14 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 450 Mm ) X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 15 G.O. Switch Handle Supporting: [ C.I. ( 75X40x6mm ) , Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 16 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 17 D.O Fuse Unit 18 Surge Arrester, 9 Kv Station Class 19 Discs Insulator Sets ( Comp. 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) I / C Dead End Clamps Etc. ) 20 Stay Set Complete 21 Staywire ( 7 / 3.15Mm ) ( 10 Kg Per Stay Set ) 22 Pipe Earthing With Gi, Charcoal & Salt 23 Prov. Lt Distribution Panel With Mccb ( 100 A, 10 Ka, 4P, 1 No. ) & Sfu ( 32 A 4 No. Rewireble ) For 63Kva Trf. As Per Specification 24 Half Clamp ( M.S. Flat 50X6 ) 25 Full Clamps ( M.S. Flat 50X6 ) 26 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 27 Aluminium Thimbles 28 Copper Thimble 29 Danger Plate 30 Barbed Wire ( Rec Sp F 3 / 1981 ) 31 Lt Cable 3-1 / 2 Core-95Mm Sq. 32 Alluminium Paint 33 Prov.Acsr, 6 / 1 / 3.35 Mm 34 Prov.63Kva S / Stn Structure Protection A / W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. 35 Erection Part Of 11 / .4 Kv 63 Kva Distribution Sub Station 36 11 / .4 Kv 63Kva Dtr ( Rec Sep. Ord 11 / 1976 37 Prov. St Polepole 9 Mtr. Long W / L 200 Kgs 38 Muff For Steel Tubular Pole With Concrete Filling 39 X-Arm: [ Channel Iron ( 100X50x5 Mm ) , Length : 2800 Mm X 2 Nos ] For Incomer Line 40 Ms A.I. ( 50X50x6 Mm ) , Length: 2800 Mm X ( 1 Nos For LaS ) 41 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length : 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch 42 X-Arm: [ Channel Iron ( 100X50x6 Mm ) , Length : 2800 Mm X 2 Nos ] For Transformer Bed 43 X-Arm [ Channel Iron ( 100X50x6 Mm ) , Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer ] 44 Ms A.I. ( 50X50x6 Mm ) , Length: ( 2800 Mm ) X 2 No. 45 Ms Angle Iron ( 35X35x5 Mm ) , Length : 460 Mm X 2 Nos 46 Ms A.I. ( 50X50x6 Mm ) , Length: ( 950 Mm ) X 2 Nos. Of Bed Knee Bracing 47 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 48 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 450 Mm ) X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 49 G.O. Switch Handle Supporting: [ C.I. ( 75X40x6mm ) , Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 50 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 51 D.O Fuse Unit 52 Surge Arrester, 9 Kv Station Class 53 Discs Insulator Sets ( Comp. 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) I / C Dead End Clamps Etc. ) 54 Stay Set Complete 55 Staywire ( 7 / 3.15Mm ) ( 10 Kg Per Stay Set ) 56 Pipe Earthing With Gi, Charcoal & Salt 57 Prov. Lt Distribution Panel With Mccb ( 100 A, 10 Ka, 4P, 1 No. ) & Sfu ( 32 A 4 No. Rewireble ) For 63Kva Trf. As Per Specification 58 Half Clamp ( M.S. Flat 50X6 ) 59 Full Clamps ( M.S. Flat 50X6 ) 60 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 61 Aluminium Thimbles 62 Copper Thimble 63 Danger Plate 64 Barbed Wire ( Rec Sp F 3 / 1981 ) 65 Lt Cable 3-1 / 2 Core-95Mm Sq. 66 Alluminium Paint 67 Prov.Acsr, 6 / 1 / 3.35 Mm 68 Prov.63Kva S / Stn Structure Protection A / W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. 69 Supply Part Of Ht Line With Acsr 6 / 1 / 3.35 Mm Sq. On Steel Poles ( 0.190Km ) 70 Acsr 6 / 1 / 3.35 ( 55Mm² ) { Includes 3 Conductor Lengths For 3F And Additional 1% ( Sag, Jumpering And Wastage } 71 Prov. Steel Tubular Poles. 9Mtrs 72 Muff For Steel Tubular Pole ( 2000Mm Long ) With Concrete Filling 73 Cross Arm: [ Channel Iron ( 100X50x6 Mm ) , Length 1270 Mm ( I / C Tolerence Of 100Mm Either Side ) X2 Structure ( Run Through Structure ( Formation Tringle ) 74 Angle Iron ( 50X50x5 Mm ) , Length ( 2X750 ) Mm X 1 Structures ( Run Through Structure ( Formation Tringle ) 75 Pole Top Bracket [ Msci:100X50x6mm-100Mm ] 76 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure ( Run Through Structure ( Formation Tringle ) 77 Belt Set - Ms Angle Iron: 50X50x6, Length [ 1800 Mm X 2 No. ] For Dead End Structures 78 X-Bracing Set - Ms Angle Iron: 50X50x6, Length [ 2125 Mm X2 No. ] For Dead End Structures 79 X-Arm ( Horizental ) - Ms C. Iron: 50X50x6, Length [ 2340 Mm X2 No. ] For Dead End Structures 80 Discs Insulator Sets On Dead End Structures ( Comprising 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) X ( 3 No. Conductors ) X ( 2 No. Sides ) For Dead End Structures 81 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure For Dead End Structures 82 Stay Set Complete In All Respect ( Single Pole-1No. , / D. Pole Structures-4Nos. ) 83 Stay Wire ( 7 / 3.15 Mm ) ( 8.0 Kg Per Stay Set ) 84 Ht Earthing Set Complete ( Rec Constr. Standared J-1 ) 85 Single Continous Earth Wire ( Gi, 8 Swg ) { Alongwith 1 Wire Lengths For Avg. One Road Crossing @ 20 M And Additional 1% ( Sag And Wastage ) } @ 0.102 Kg / M 86 Eye Hook For Earth Wire 87 Earth Wire Clamp 88 Ms Chanel Iron 75X40x6mm, Length: 2400Mm For Road Crossing / G.O Switch 89 Half Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 90 Full Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 91 Danger Plate ( 250X200x1.6 Mm ) 92 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 93 Barbed Wire ( Rec Sp F 3 / 1981 ) 94 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 95 Alluminium Paint 96 Erection Part Of Ht Line With Acsr 6 / 1 / 3.35 Mm Sq. On Steel Poles ( 0.190Km ) 97 Acsr 6 / 1 / 3.35 ( 55Mm² ) { Includes 3 Conductor Lengths For 3F And Additional 1% ( Sag, Jumpering And Wastage } 98 Prov. Steel Tubular Poles. 9Mtrs 99 Muff For Steel Tubular Pole ( 2000Mm Long ) With Concrete Filling 100 Cross Arm: [ Channel Iron ( 100X50x6 Mm ) , Length 1270 Mm ( I / C Tolerence Of 100Mm Either Side ) X2 Structure ( Run Through Structure ( Formation Tringle ) 101 Angle Iron ( 50X50x5 Mm ) , Length ( 2X750 ) Mm X 1 Structures ( Run Through Structure ( Formation Tringle ) 102 Pole Top Bracket [ Msci:100X50x6mm-100Mm ] 103 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure ( Run Through Structure ( Formation Tringle ) 104 Belt Set - Ms Angle Iron: 50X50x6, Length [ 1800 Mm X 2 No. ] For Dead End Structures 105 X-Bracing Set - Ms Angle Iron: 50X50x6, Length [ 2125 Mm X2 No. ] For Dead End Structures 106 X-Arm ( Horizental ) - Ms C. Iron: 50X50x6, Length [ 2340 Mm X2 No. ] For Dead End Structures 107 Discs Insulator Sets On Dead End Structures ( Comprising 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) X ( 3 No. Conductors ) X ( 2 No. Sides ) For Dead End Structures 108 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure For Dead End Structures 109 Stay Set Complete In All Respect ( Single Pole-1No. , / D. Pole Structures-4Nos. ) 110 Stay Wire ( 7 / 3.15 Mm ) ( 8.0 Kg Per Stay Set ) 111 Ht Earthing Set Complete ( Rec Constr. Standared J-1 ) 112 Single Continous Earth Wire ( Gi, 8 Swg ) { Alongwith 1 Wire Lengths For Avg. One Road Crossing @ 20 M And Additional 1% ( Sag And Wastage ) } @ 0.102 Kg / M 113 Eye Hook For Earth Wire 114 Earth Wire Clamp 115 Ms Chanel Iron 75X40x6mm, Length: 2400Mm For Road Crossing / G.O Switch 116 Half Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 117 Full Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 118 Danger Plate ( 250X200x1.6 Mm ) 119 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 120 Barbed Wire ( Rec Sp F 3 / 1981 ) 121 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 122 Alluminium Paint 123 Supply Part Of 11 / .4 Kv 63 Kva Distribution Sub Station 124 11 / .4 Kv 63Kva Dtr ( Rec Sep. Ord 11 / 1976 125 Prov. St Polepole 10 Mtr. Long W / L 200 Kgs 126 Muff For Steel Tubular Pole With Concrete Filling 127 X-Arm: [ Channel Iron ( 100X50x5 Mm ) , Length : 2800 Mm X 2 Nos ] For Incomer Line 128 Ms A.I. ( 50X50x6 Mm ) , Length: 2800 Mm X ( 1 Nos For LaS ) 129 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length : 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch 130 X-Arm: [ Channel Iron ( 100X50x6 Mm ) , Length : 2800 Mm X 2 Nos ] For Transformer Bed 131 X-Arm [ Channel Iron ( 100X50x6 Mm ) , Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer ] 132 Ms A.I. ( 50X50x6 Mm ) , Length: ( 2800 Mm ) X 2 No. 133 Ms Angle Iron ( 35X35x5 Mm ) , Length : 460 Mm X 2 Nos 134 Ms A.I. ( 50X50x6 Mm ) , Length: ( 950 Mm ) X 2 Nos. Of Bed Knee Bracing 135 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 136 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 450 Mm ) X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 137 G.O. Switch Handle Supporting: [ C.I. ( 75X40x6mm ) , Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 138 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 139 D.O Fuse Unit 140 Surge Arrester, 9 Kv Station Class 141 Discs Insulator Sets ( Comp. 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) I / C Dead End Clamps Etc. ) 142 Stay Set Complete 143 Staywire ( 7 / 3.15Mm ) ( 10 Kg Per Stay Set ) 144 Pipe Earthing With Gi, Charcoal & Salt 145 Prov. Lt Distribution Panel With Mccb ( 100 A, 12 Ka, 4P, 1 No. ) & Sfu ( 32 A 4 No. Rewireble ) For 63 Kva Trf. As Per Specification 146 Half Clamp ( M.S. Flat 50X6 ) 147 Full Clamps ( M.S. Flat 50X6 ) 148 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 149 Aluminium Thimbles 150 Copper Thimble 151 Danger Plate 152 Barbed Wire ( Rec Sp F 3 / 1981 ) 153 Lt Cable 3-1 / 2 Core-185Mm Sq. 154 Alluminium Paint 155 Prov.Acsr, 6 / 1 / 3.35 Mm 156 Prov.63Kva S / Stn Structure Protection A / W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. 157 Erection Part Of 11 / .4 Kv 63 Kva Distribution Sub Station 158 11 / .4 Kv 63Kva Dtr ( Rec Sep. Ord 11 / 1976 159 Prov. St Polepole 10 Mtr. Long W / L 200 Kgs 160 Muff For Steel Tubular Pole With Concrete Filling 161 X-Arm: [ Channel Iron ( 100X50x5 Mm ) , Length : 2800 Mm X 2 Nos ] For Incomer Line 162 Ms A.I. ( 50X50x6 Mm ) , Length: 2800 Mm X ( 1 Nos For LaS ) 163 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length : 2800 Mm X 4 Nos ] For Supporting Do Fuse Unit & Go Switch 164 X-Arm: [ Channel Iron ( 100X50x6 Mm ) , Length : 2800 Mm X 2 Nos ] For Transformer Bed 165 X-Arm [ Channel Iron ( 100X50x6 Mm ) , Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer ] 166 Ms A.I. ( 50X50x6 Mm ) , Length: ( 2800 Mm ) X 2 No. 167 Ms Angle Iron ( 35X35x5 Mm ) , Length : 460 Mm X 2 Nos 168 Ms A.I. ( 50X50x6 Mm ) , Length: ( 950 Mm ) X 2 Nos. Of Bed Knee Bracing 169 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 2800 Mm ) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 170 Ms Angle Iron ( 50X50x6 Mm ) , Length : ( 450 Mm ) X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 171 G.O. Switch Handle Supporting: [ C.I. ( 75X40x6mm ) , Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 172 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 173 D.O Fuse Unit 174 Surge Arrester, 9 Kv Station Class 175 Discs Insulator Sets ( Comp. 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) I / C Dead End Clamps Etc. ) 176 Stay Set Complete 177 Staywire ( 7 / 3.15Mm ) ( 10 Kg Per Stay Set ) 178 Pipe Earthing With Gi, Charcoal & Salt 179 Prov. Lt Distribution Panel With Mccb ( 100 A, 12 Ka, 4P, 1 No. ) & Sfu ( 32 A 4 No. Rewireble ) For 63 Kva Trf. As Per Specification 180 Half Clamp ( M.S. Flat 50X6 ) 181 Full Clamps ( M.S. Flat 50X6 ) 182 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 183 Aluminium Thimbles 184 Copper Thimble 185 Danger Plate 186 Barbed Wire ( Rec Sp F 3 / 1981 ) 187 Lt Cable 3-1 / 2 Core-185Mm Sq. 188 Alluminium Paint 189 Prov.Acsr, 6 / 1 / 3.35 Mm 190 Prov.63Kva S / Stn Structure Protection A / W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. 191 Supply Part Of Ht Line With Acsr 6 / 1 / 3.35 Mm Sq. On Steel Poles ( 0.230 Km ) 192 Acsr 6 / 1 / 3.35 ( 55Mm² ) { Includes 3 Conductor Lengths For 3F And Additional 1% ( Sag, Jumpering And Wastage } 193 Prov. Steel Tubular Poles. 9Mtrs 194 Muff For Steel Tubular Pole ( 2000Mm Long ) With Concrete Filling 195 Cross Arm: [ Channel Iron ( 100X50x6 Mm ) , Length 1270 Mm ( I / C Tolerence Of 100Mm Either Side ) X2 Structure ( Run Through Structure ( Formation Tringle ) 196 Angle Iron ( 50X50x5 Mm ) , Length ( 2X750 ) Mm X 1 Structures ( Run Through Structure ( Formation Tringle ) 197 Pole Top Bracket [ Msci:100X50x6mm-100Mm ] 198 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure ( Run Through Structure ( Formation Tringle ) 199 Belt Set - Ms Angle Iron: 50X50x6, Length [ 1800 Mm X 2 No. ] For Dead End Structures 200 X-Bracing Set - Ms Angle Iron: 50X50x6, Length [ 2125 Mm X2 No. ] For Dead End Structures 201 X-Arm ( Horizental ) - Ms C. Iron: 50X50x6, Length [ 2340 Mm X2 No. ] For Dead End Structures 202 Discs Insulator Sets On Dead End Structures ( Comprising 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) X ( 3 No. Conductors ) X ( 2 No. Sides ) For Dead End Structures 203 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure For Dead End Structures 204 Stay Set Complete In All Respect ( Single Pole-1No. , / D. Pole Structures-4Nos. ) 205 Stay Wire ( 7 / 3.15 Mm ) ( 9.0 Kg Per Stay Set ) 206 Ht Earthing Set Complete ( Rec Constr. Standared J-1 ) 207 Single Continous Earth Wire ( Gi, 8 Swg ) { Alongwith 1 Wire Lengths For Avg. One Road Crossing @ 20 M And Additional 1% ( Sag And Wastage ) } @ 0.102 Kg / M 208 Eye Hook For Earth Wire 209 Earth Wire Clamp 210 Ms Chanel Iron 75X40x6mm, Length: 2400Mm For Road Crossing / G.O Switch 211 Half Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 212 Full Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 213 Danger Plate ( 250X200x1.6 Mm ) 214 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 215 Barbed Wire ( Rec Sp F 3 / 1981 ) 216 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 217 Alluminium Paint 218 Erection Part Of Ht Line With Acsr 6 / 1 / 3.35 Mm Sq. On Steel Poles ( 0.230 Km ) 219 Acsr 6 / 1 / 3.35 ( 55Mm² ) { Includes 3 Conductor Lengths For 3F And Additional 1% ( Sag, Jumpering And Wastage } 220 Prov. Steel Tubular Poles. 9Mtrs 221 Muff For Steel Tubular Pole ( 2000Mm Long ) With Concrete Filling 222 Cross Arm: [ Channel Iron ( 100X50x6 Mm ) , Length 1270 Mm ( I / C Tolerence Of 100Mm Either Side ) X2 Structure ( Run Through Structure ( Formation Tringle ) 223 Angle Iron ( 50X50x5 Mm ) , Length ( 2X750 ) Mm X 1 Structures ( Run Through Structure ( Formation Tringle ) 224 Pole Top Bracket [ Msci:100X50x6mm-100Mm ] 225 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure ( Run Through Structure ( Formation Tringle ) 226 Belt Set - Ms Angle Iron: 50X50x6, Length [ 1800 Mm X 2 No. ] For Dead End Structures 227 X-Bracing Set - Ms Angle Iron: 50X50x6, Length [ 2125 Mm X2 No. ] For Dead End Structures 228 X-Arm ( Horizental ) - Ms C. Iron: 50X50x6, Length [ 2340 Mm X2 No. ] For Dead End Structures 229 Discs Insulator Sets On Dead End Structures ( Comprising 1 No. Disc: ^^ ( Porcelain, Bs, 12 Kv, 90 Kn ) Including Dead End Clamps Etc. ) X ( 3 No. Conductors ) X ( 2 No. Sides ) For Dead End Structures 230 11 Kv Pin Insulators ( Porcelain, 12 Kv, 10 Kn ) : 3 No Per Pole Structure For Dead End Structures 231 Stay Set Complete In All Respect ( Single Pole-1No. , / D. Pole Structures-4Nos. ) 232 Stay Wire ( 7 / 3.15 Mm ) ( 9.0 Kg Per Stay Set ) 233 Ht Earthing Set Complete ( Rec Constr. Standared J-1 ) 234 Single Continous Earth Wire ( Gi, 8 Swg ) { Alongwith 1 Wire Lengths For Avg. One Road Crossing @ 20 M And Additional 1% ( Sag And Wastage ) } @ 0.102 Kg / M 235 Eye Hook For Earth Wire 236 Earth Wire Clamp 237 Ms Chanel Iron 75X40x6mm, Length: 2400Mm For Road Crossing / G.O Switch 238 Half Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 239 Full Clamp ( On D / P Dead End Str:4Nos; On Run Through Str. 2Nos. ) 240 Danger Plate ( 250X200x1.6 Mm ) 241 M. S. Nuts & Bolts Off Sizes ( Galvanised Coated ) [ Prefarably 16Mm Ø Or More ( With Flat And Spring Washer ) 242 Barbed Wire ( Rec Sp F 3 / 1981 ) 243 G.O Ab Switch Unit ( 11Kv, 400, 663Ka ) Tripple Pole O / D Type 244 Alluminium Paint