Request For Proposal For Supplying Various Equipments With One Year Warranty And Two Years Cmc (1Year Plus 2Years) And Chemicals, Crm And General Items ,Glasswares For 1 No. Of Sub-Divisional Level Water Testing Laboratory In Sub-Division Petarwar. , List Of Instrument Required For Upgrading District Lab/Sub- Divisional Lab For Getting Nabl , Ph Meter Digital-Digital With Electrode,Branded Must Be With Calibration Certificate Dully Approved From Nabl Certified Calibration Laboratory And Item Should Be In Calibration Scope And Certified Nabl Logo . Mannual Must Be Submitted Along With The Equipment And Should Be Ce Certified. , Digital Nephloturbiditymeter Brand-Digital With Electrode,Branded Must Be With Calibration Certificate Dully Approved From Nabl Certified Calibration Laboratoryand Item Should Be In Calibration Scope And Certified Nabl Logo . Mannual Must Be Submitted Along With The Equipment And Should Be Ce Certified. , Ion Meter With Flouride Electrode Electrode And 60 Ml Fehling Solution And All Accessories Branded Must Be With Calibration Certificate Dully Approved From Nabl Certified Calibration Laboratory And Item Should Be In Calibration Scope And Certified Nabl Logo . Mannual Must Be Submitted Along With The Equipment And Should Be Ce Certified. , Hot Air Oven, Branded Must Be With Calibration Certificate Dully Approved From Nabl Certified Calibration Laboratory And Item Should Be In Calibration Scope And Certified Nabl Logo . Mannual Must Be Submitted Along With The Equipment And Should Be Ce Certified. , Hot Plate With Magetic Stirrer-Branded Must Be With Calibration Certificate Dully Approved From Nabl Certified Calibration Laboratory And Item Should Be In Calibration Scope And Certified Nabl Logo. Mannual Must Be Submitted Along With The Equipment And Should Be Ce Certified. , Double Distillation Unit -All Quartz,Material Of Distillation Unit Shall Be Made Of High Purity Electronic Grade Transparent Quartz Only, Heaters: Demountable Boiler Panel With Compact Design Of Boilers & Condensers Easilymountable For Cleaning And Maintenance With Spiral Heaters,Electrical Requirement: 230-250 Volts 10/50Hz, Single Phase ,Dist. Water Output Capacity (Ltr/Hr) : 2.5 Ltrs/Hr,Total Power Consumed-4.4 Kw, Conductivity (?S/Cm): <1*10-6,Distillation Units Type-Vertical,Biological Activity-Pyrogen Free,Double Stage Glass (Quartz) Distillation Units-Yes,Condenser-Quartz, Cooling Water Consumption (Ltr/Hr)-2 Ltrs/Min,Boiler-Quartz,Demountable Model And Should Be Connected With Rubber Tubling And Pinch Cock For Cleaning Sediments In Primary Boilers And Must Be Ce/ Iso Certified. , Digital Analytical Digital Balance Four Digit , Analytical Balance Capacity 220 Gm Accuracy 0.1 Mg With Internal Calibration Pan Size Ø 90 Mm, Branded Must Be With Calibration Certificate Dully Approved From Nabl Certified Calibration Laboratory And Item Should Be In Calibration Scope And Certified Nabl Logo. Mannual Must Be Submitted Along With The Equipment And Should Be Ce Certified. , Weight Box With Separate Calibrated Nabl Certificate For Each And Every Single Weight)F1-Class Single Weight(1 Mg,2 Mg,5 Mg,10 Mg,50 Mg,100 Mg,200 Mg,500 Mg,1 G,2 G,5 G,10 G,20 G,50 G,100 G,200 G)Branded Must Be With Calibration Certificate Dully Approved From Nabl Certified Calibration Laboratory And Item Should Be In Calibration Scope And Certified Nabl Logo. Mannual Must Be Submitted Along With The Equipment And Should Be Ce Certified. , Digital Hygrometer-Temp.Range -500C ~ +700C,Temp. Measuring Accuracy: ± 10C,Temp. Resolution: 0.10C,Humidity Meas.Range: 10% Rh ~ 99% ,Humidity Accuracy: ±5% Rh,Humidity Resolution: 1%Branded Must Be With Calibration Certificate Dully Approved From Nabl Certified Calibration Laboratory And Item Should Be In Calibration Scope And Certified Nabl Logo. Mannual Must Be Submitted Along With The Equipment , Digital Thermometer Pressison Thermometer Branded Must Be With Calibration Certificate Dully Approved From Nabl Certified Calibration Laboratory And Item Should Be In Calibration Scope And Certified Nabl Logo. Mannual Must Be Submitted Along With The Equipment , Glass Thermometer 110 Degree Branded Must Be With Calibration Certificate Dully Approved From Nabl Certified Calibration Laboratory And Item Should Be In Calibration Scope And Certified Nabl Logo. Mannual Must Be Submitted Along With The Equipment , List Of Glasswares Required For Upgrading District Lab/Sub Divisional Lab For Getting Nabl-Glasswares (Glasswares Must Be Supported By Calibration Certificate Dully Approved By Nabl Certified Calibratiion Agency) , Burette , 25 Ml , 50 Ml , Pipette (Graduated)A-1 Class And With Certificate , 1 Ml , 5 Ml , 10 Ml , 25 Ml , Conical Flask , 100 Ml , 250 Ml , Measuring Cylinder (Graduated) , 5Ml , 10 Ml , 25 Ml , 50 Ml , 100 Ml , 250 Ml , Volumetric Flask , 50 Ml , 100 Ml , 250 Ml , 500 Ml , 1000 Ml , Beaker , 50 Ml , 100 Ml , 250 Ml , 500 Ml , 1000 Ml , Pipette - Bulb , 10 Ml , 25 Ml , Filter Funnel , 3”Dia , 5”Dia , Glass Rod (Big) , Reagent Bottle (Ground G – Stopper) , 250 Ml , 500 Ml , 1000 Ml , Reagent Bottle (With Screw Cap) , 250 Ml , 500 Ml , 1000 Ml , Amber Colour Glass Reagent Bottle With Screw Cap , 250Ml , 500Ml , 1000Ml , Amber Colour Beurette 25 Ml , Broad Mouth Glass Stopper Bottle 1000Ml , Pipette Stand , Porcelain Dish 250 Ml , Burette Stand-Accuracy As Per Class- A Plastic Coated & Burette Clamp , Ice Box , Watch Glass (Medium) , Nessler Tubes 50Ml , Test Tube Stand-Big Hole (Nessler Tube Size) Big Hole (Nessler Tube Size) , List Of Miscellenous Items Required For Upgrading District Lab/ Sub Divisional Lab For Getting Nabl , Air Conditioners (If Required) 2 (One Wet Lab And One For Micro Section) , Computer System With All Accessories (Scanner And Printer All In One) , Emergency Safety Shower Cum Eye Wash Fountain(Purchase And Instaalation)- Isi Mark , Stationary Items , Fire Extinguisher(Capacity-4 Kg,Abc Type,With Pressure Meter) , First Aid Box , Apha Standard Mannual , Complain & Suggestion Box , Safety Signages , Lay Out Of Concerned Lab , Sampledisposal Bucket , Executive Revolving Chairs (Godrej) , Office Simplechairs , Plastic Cello Chairs , Table Official Wooden (Medium Size) , Shoe Rack-Metal/Foldable(Size-4 Ft*4 Ft) , Anti Virus , Notice Board (4X3) , Dustbins With Cap , Steel Ladder , Visitor Chair For Visitors-3 Seater , Lab Safety Goggles Pack Of 20 , Hand Gloves(Standard Size) Pack Of 20 , Lab Apron Pack Of 20 , Head Caps Pack Of 20 , Laboratory Mask Pack Of 20 , Hand Senitizer , Door Mate , Ladies And Gents Sleeper , Tissue Paper-(Kimwipes) , Sampling Bag , Wall Clock , Sampling Bottle-Iso-:9001:2008 Certified, Capacity -500 Ml,Make- Tarson,Type-Wide Mouth,Grade-Polymer Plastic , Sampling Bottle-Iso-:9001:2008 Certified ,Capacity -1000 Ml,Make- Tarson,Type-Wide Mouth,Grade-Polymer Plastic , Chemicals/ Reagent Required For District/Sub-Divisional Labs For Getting Nabl , Turbidity (Crm) Certified Reference Materialsmust Be Nist Traceable With Uncertainity Of Measurement (Uom) Validity Period At Least 2 Years With Iso-17034 Certificate. , Ph Buffer Solution (Crm 4.01-(500Ml/Bottle) Certified Reference Materialsmust Be Nist Traceable With Uncertainity Of Measurement (Uom) Validity Period At Least 2 Years With Iso-17034 Certificate. , Ph Buffer Solution (Crm– 7.01 (500Ml/Bottle) Certified Reference Materialsmust Be Nist Traceable With Uncertainity Of Measurement (Uom) Validity Period At Least 2 Years With Iso-17034 Certificate. , Ph Buffer Solution (Crm– 9.18 (500Ml/Bottle ) Certified Reference Materialsmust Be Nist Traceable With Uncertainity Of Measurement (Uom) Validity Period At Least 2 Years With Iso-17034 Certificate. , Potassium Chloroplatinate Crm -200 Ml/Bottle Certified Reference Materialsmust Be Nist Traceable With Uncertainity Of Measurement (Uom) Validity Period At Least 2 Years With Iso-17034 Certificate. , Sodium Carbonate (Na2co3) -500 Gm/Pkt Certified Reference Materialsmust Be Nist Traceable With Uncertainity Of Measurement (Uom) Validity Period At Least 2 Years With Iso-17034 Certificate. , Calcium Carbonate (Caco3) -500Gm/Pkt Certified Reference Materialsmust Be Nist Traceable With Uncertainity Of Measurement (Uom) Validity Period At Least 2 Years With Iso-17034 Certificate. , Sodium Chloride (Nacl) -500Gm/Pkt Certified Reference Materialsmust Be Nist Traceable With Uncertainity Of Measurement (Uom) Validity Period At Least 2 Years With Iso-17034 Certificate. , Nitrate Standard Solution 1000Ppm Certified Reference Materialsmust Be Nist Traceable With Uncertainity Of Measurement (Uom) Validity Period At Least 2 Years With Iso-17034 Certificate. , Iron Standard Solution 1000 Ppm Certified Reference Materialsmust Be Nist Traceable With Uncertainity Of Measurement (Uom) Validity Period At Least 2 Years With Iso-17034 Certificate. , Fluoride Standard Solution 1000 Ppm Certified Reference Materialsmust Be Nist Traceable With Uncertainity Of Measurement (Uom) Validity Period At Least 2 Years With Iso-17034 Certificate. , Sulphuric Acid-98% 500 Ml/Bottle Brand (Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Methyl Orange Solution 125 Ml/Bottle Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Phenolpthalein Indicator 125 Ml/Bottle Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Sodium Hydroxide 500 Gm/Pkt Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Edta Salt (Triplex Iii) 500 Gm/Pkt Brand (Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Eriochrome Black T Indicator Powder 25 Gm/Pkt Brand (Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Murexide Indicator 5 Gm/Pkt Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Ammonium Buffer Solution500 Ml/Bottle Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Silver Nitrate 25 Gm/Pkt Vantor/Loba/Hi Media Or Equivalent Make Iso Certified Brand(Preferably Of Merck /A , Potassium Chromate500 Gm/Pkt Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Sodium Chloride (Nacl) 500 Gm/Pkt Ar Grade Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Potassium Chloride 500 Gm/Pkt Ar Grade Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , 1,10 Phenopthrolone(Gr) 5 Gm/Pkt Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Conc.Hydrochloric Acid-35% 500 Ml/Bottle Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Hydroxylamine Hydrochloride250 Gm/Pkt Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Ammonium Acetate 500 Gm/Pkt Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Conc.Glacial Acetic Acid (500 Ml/Bottle) Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Di-Isopropyl Ether 500 Ml/Bottle Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Sodium Acetate 500 Gm/Pkt Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Potassium Permanganate 500 Gm/Pkt Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Tisab-Lll (500 Ml/Bottle) Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Hexamethylene Tetramine Pure- 500 Gm/Pkt Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Hydrazinium Sulphate 100 Gm/Pkt Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Distilled Water (Conductivity Below 0.1?S)Jars Brand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Pa Coli Kit 10 Test/Kitbrand(Preferably Of Merck /Avantor/Loba/Hi Media Or Equivalent Make Iso Certified , Add Gst 18% , Add Labour Cess 1%