}

Supply Of Consumables, Reagents And Other Items-Transfusion Medicine, kollam-Kerala

Government Departments has published Supply Of Consumables, Reagents And Other Items-Transfusion Medicine. Submission Date for this Tender is 16-03-2023. Uniform Tenders in kollam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

36572990
Supply Of Consumables, Reagents And Other Items-Transfusion Medicine
Open Tender
Indian
Kerala
Kollam
16-03-2023

Tender Details

SUPPLY OF CONSUMABLES, REAGENTS AND OTHER ITEMS-Transfusion Medicine Supply Of Reagents, Consumables And Others For The Department Of Transfusion Medicine , Consumables, Reagents & Other Items , Lancet - Ready To Use Manual Blood Lancet; Sharp Point, All Sides Tapered Provides Quick, Clean Puncture Ribbed Surface For Firm Grip; Typical Incision Depth; Approximately 2Mm; Single Use; Sterile Individually Packed; Chrome-Polished Stainless Steel; Length, Approximately 40Mm,Width, Approximately 6Mm,Thickness, Approximately 0.5Mm , Tourniquet- Elastic Arm Tourniquet With Plastic Buckle; Should Have A Stretchy Strap That Helps In Easy Adjustment; Adjustable Cuff Size From 2 Inch To 5 Inch Diameter; Should Be Comfortable For The Blood Donor , Spot Plaster - Should Provide Coverage And Protection Of Phlebotomy Site; Should Besterile Andbreathable; Square Or Round Shaped. , Exercise Ball - Soft Rubber Ball; 10 Cm Diameter; Adequate Grip , Storage Vial Autoclavable Sv 10 - 10Ml Vials Plastic Vials; Should Be Autoclavable Durable And Long Lasting , Microtip Yellow 2-200Microlitre - Microtip 2-200 Microlitre Compatible With Multi Channel Pipette;Even Liquid Dispensing And A Good Fit On The Micropipette. Autoclavable; Hydrophobic, Medical Grade Polypropylene, Free Of Lubricants, Dyes And Heavy Metals;Tips With Good Seal On Micro-Pipettes; More Transparency For Clear Visualization ; High Clarity And Finer Tip Orifice , Vacuum Tubes Edta - Vacuum Polyproplene Tubes With Edta; Transparent And See Through 13X75 Mm Size. , Vacuum Tubes Plain -Vacuum Polyproplene Tubes; Transparent And See Through 13X75 Mm Size. , Vacuum Tubes With Gel - Vacuum Polyproplene Tubes With Gel Activator; Transparentand See Through; 13X75 Mm Size. , Test Tube Rack Sv 10 - Should Fit 10Ml Vials Plastic Autoclavable Vials; Durable And Long Lasting , Test Tube Racks - Should Fit20 , 13* 75 Mm Test Tubes; Durable And Long Lasting. , Filter Paper Kalpi - Sheets Should Have 0.5 M Width , Available As Rolls; Should Have Good Absorption , Slides For Microscopy - Microscope Glass Slides 75 X 25 X 1.4 Mm; Scratch Resisitant And Clear; Suitable For Haema Agglutination Tests.-50/Pkt , Acdsolution A Anticoagulant - 500 Mlanticoagulant Citrate Dextrose Solution(Acd) Solution A; Should Be Sterile And Pyrogen Free Solution In A Polyolefin Bag Or Bottle; Should Not Contain Antimicrobial And Bacteriostatic Reagents;The Bag Should Be Nontoxic And Biologically Inert; The Bag-Solution Unit Should Beclosed System; The Bag/ Bottle Should Beoverwrapped To Provide Extra Protection ; Each 100 Ml Should Contain: (%W/V) Citric Acid, Monohydrate 0.8 G; Dextrose Monohydrate 2.45 G; Sodium Citrate Dihydrate 2.2 G; And Water For Injection. , 3 Cell Panel Screening Cells - 3-Cell Screening For Patients; Should Contains A Set Of 3 Vials , 10 Ml Each For Iat And Nacl Testing; Should Include Two Rhd Positive Cells (Ccdee, Cw+, Ccdee) And One Cell Rhd Negative (Cc.Ee) With Configuration: R1wr1, R2r2, Rr; Should Include Double Dose For Fya, Fyb, Jka, Jkb, M, S And S, And At Least One Cell Positive For K, Lea, Leb, P1 And N; Should Betested By Serology For Hla Class I Antigens; Should Have A Stability Of 7 Weeks ; Should Be Supplied On Standing Order Every 4 Weeks; Should Be Compatible With Cat Used In Matrix Centrifuge. , 11 Cell Panel Cells - A Set Of 11 (4 Ml) Vials For Iat And Nacl Testing; Should Have Afixed Rh Phenotype Pattern And Assured Presence Of Cells Possessing Double-Dose Antigens Throughout Representing The Common Asian /Indian Blood Group Antigens; Should Betested By Serology For Hla Class I Antigens; Shouldhave A Stability Of 7 Weeks; Should Be Supplied On Standing Order Every 4 Weeks;Should Be Compatible With Cat Used In Matrix Centrifuge. , Anti H Antisera - Ready To Use Purified Lectin Extract Of Ulex Europaeus Seeds; Optically Clear ; Titre: ~ 1:16 With O Group Cells; Specificity: Negative Reacting With O Phenotype H; Reactivity:Graded Reactivity With Different Red Cells,O>A >A B>B>A >A B ; Shouldmaintain Optimum Ph ,Ionic Strngth, Protein Concentration And Antibody Activity; Stability Of1 Year-5Ml/Pack , Anti A1 Antisera - Ready To Use Purified Lectin (Phytohemagglutinin) Extract Of Dolichos Biflorus Seeds; Optically Clear Solution; Should Have Titre Of 1 ~ 1:16 With A1cells And1 ~ 1:16 With A1b Cells; Specificity Of A1 Antigen Shouldmaintain Optimum Ph ,Ionic Strngth, Protein Concentration And Antibody Activity; Sta-Bility Of2 Year.-5Ml/Pack , Anti D Igg - Should Have Atitreupto 512 Dilution By Two Fold Serial Dilution In Tubes; Thereagent Should Bespecific For The Purpose Or Not With Rh Negative Cells As It Should Not Sensitize Rh Negative Cells; Should Eliminate Prozone Phenomenon With Strongly Sensitized Cells In Dat; Should Eliminate Negative Reaction With Weakly Sensitized Cells In Dat; Stableat 2-8ºc With Shelf Life Of 2 Years; Sodium Azide Is Added To The Antibodies At 0.1% Concentration As Preservative-10Ml/Pack , Anti D (Igg+ Igm) - Should Contain Anti-D (Igm + Igg) Monoclonal Antibodies; Should Agglutinate In Saline Solution;Should Be Active At Room Temperature And 37°C; Usable On Glass Slide As Well As In The Tube; Should Have A Shelf Life Of 2 Years At 2-8 Degree C; Should Have An Avidity Of 5-10 Sec; Igm Titre Should Be 1/256 And Igg 1/8; 10Ml/Pack , Pappain - Stabilized Ready To Use Papain Reagent (Liquid State); Standardised As Per Aabb And Fda Guidelines; Should Have Thiol Reducing Agent; Stable For 2 Years At 2-8Degree C; Can Be Used In Cat Compatible With Matrix Centrifuge-5Ml/Pack , Bovine Albumin (10Ml)- 22% Purified Bovine Serum Albumin; Ph 7.1 (± 0.2%) ; Globulin Free Should Give Single Band On Gel Electrophoresis; Standardized As Peraabb And Fda Guidelines; Optimum Concentration Of Stabilisers. Stable At 2-8Degree C For 2 Years.-10Ml/Pack , Anti C - Ready To Use Reagents Prepared From Monoclonal Cell Culture Supernatant Of Respective Human Cell Lines;Should Be Able To Detect 1:32 With R’R (Dce/Dce) Phenotype,1:32 With Rr (Dce/Dce) Phenotype,1:32 With R”R (Dce/Dce) Phenotype;100%Specificity To C Antigen; Shouldmaintain Optimum Ph ,Ionic Strngth, Protein Concentration And Antibody Activity; Stability Of2 Year; Standardised As Per Aabb And Fda Guidelines; 10Ml Vial , Anti C - Ready To Use Reagents Prepared From Monoclonal Cell Culture Supernatant Of Respective Human Cell Lines;Should Be Able To Detect 1:32 With R’R (Dce/Dce) Phenotype,1:32 With Rr (Dce/Dce) Phenotype,1:32 With R”R (Dce/Dce) Phenotype;100%Specificity To C Antigen; Shouldmaintain Optimum Ph ,Ionic Strngth, Protein Concentration And Antibody Activity; Stability Of2 Year; Standardised As Per Aabb And Fda Guidelines.-2Ml/Pack , Anti E - Ready To Use Reagents Prepared From Monoclonal Cell Culture Supernatant Of Respective Human Cell Lines;Should Be Able To Detect 1:32 With R’R (Dce/Dce) Phenotype,1:32 With Rr (Dce/Dce) Phenotype,1:32 With R”R (Dce/Dce) Phenotype;100%Specificity To E Antigen; Shouldmaintain Optimum Ph ,Ionic Strngth, Protein Concentration And Antibody Activity; Stability Of2 Year; Standardised As Per Aabb And Fda Guidelines--2Ml/Pack , Anti E - Ready To Use Reagents Prepared From Monoclonal Cell Culture Supernatant Of Respective Human Cell Lines;Should Be Able To Detect 1:32 With R’R (Dce/Dce) Phenotype,1:32 With Rr (Dce/Dce) Phenotype,1:32 With R”R (Dce/Dce) Phenotype;100%Specificity To E Antigen; Shouldmaintain Optimum Ph ,Ionic Strngth, Protein Concentration And Antibody Activity; Stability Of2 Year; Standardised As Per Aabb And Fda Guidelines--2Ml/Packl , Anti Lewis A - 100% Specificity To Anti Le A Antigen; Shouldmaintain Optimum Ph ,Ionic Strngth, Protein Concentration And Antibody Activity; Stability Of2 Year; Standardised As Per Aabb And Fda Guidelines--2Ml/Pack , Anti Duffy A - 100% Specificity To Duffy A Antigen; Shouldmaintain Optimum Ph ,Ionic Strngth, Protein Concentration And Antibody Activity; Stability Of2 Year; Standardised As Per Aabb And Fda Guidelines--2Ml/Pack , Anti M - 100% Specificity To M Antigen; Shouldmaintain Optimum Ph ,Ionic Strngth, Protein Concentration And Antibody Activity; Stability Of2 Year; Standardised As Per Aabb And Fda Guidelines--2Ml/Pack , Monospecific Gel Cards - Should Havemicrotubes Pre-Filled With Gel In A Suitable Buffer Containing Monospecific Anti-Igg Antibodies; Should Rule Out Anti Complement Activity In Ahg Tests Performed; Card Should Be Photocopiable ; Shelf Life Of 1 Year; Standardised As Per Fda Guidelines; Should Be Compatible With Matrix Centrifuge. , Elution Kit For Aiha - Should Identifyantibodies From Sensitized Red Cells ; Ready-To-Use Reagents For The Acid Elution Of Most Common Antibodies; Should Havestability;Color Change To Indicate End Of Reaction Phase . , Forward &Reverse Abo Grouping Card - Forward And Reverse Cat With Grouping Card With Autocontrol; Should Contain Monoclonal Anti-A, Anti-B And Anti-D (Igm) (Vi-)A Negative Control Andneutral Gel Used For Reverse Grouping; Card Should Be Photocopiable ; Shelf Life Of 1 Year; Should Be One Profile/Card; Standardised As Per Aabb Guidelines; Should Be Compatible With Matrix Centrifuge.; 24/Pack , Rh Kell Grouping Cards - Forward And Reverse Cat With Grouping Card With Autocontrol; Should Contain Monoclonal Anti-A, Anti-B And Anti-D (Igm) (Vi-)A Negative Control Andneutral Gel Used For Reverse Grouping; Card Should Be Photocopiable ; Shelf Life Of 1 Year; Should Be One Profile/Card; Standardised As Per Aabb Guidelines; Should Be Compatible With Matrix Centrifuge;24/Pack , Rh View Box - Should Have Soft Fluorescent, Glare-Free Light That Provides Excellent Uniform Slide Illumination; 230 V,50 Hz; Temperature Indicator Required; Compact And Light Weight; , Haemoglobinometer - Portable Hand Held Analyser; Light Weight Less Than 250 Gm For Transportation To Camp Site ; Interpretable Results Within 10 Seconds; Cuvettes Should Be Reagent Free; Should Have Battery Back Up; Should Have An Option For Software Installation For Easy Data Transmission; Should Have Two Charging Possibilities- Usb And Adaptor; Should Be Robust For Mobile Use; Should Have Minimal Maintainenance And Cleaning; Should Have Option For Barcode Scans. , Anti N-100% Specificity Ton Antigen; Shouldmaintain Optimum Ph ,Ionic Strngth, Protein Concentration And Antibody Activity; Stability Of2 Year; Standardised As Per Aabb And Fda Guidelines; 2Ml/Pack

Key Value

Document Fees
INR 943 /-
EMD
INR 2806.0 /-
Tender Value
INR 2.80 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail