}

Tender For Supply Of Consumables For Cathlab Items, kanpur-Uttar Pradesh

Government Departments has published Tender For Supply Of Consumables For Cathlab Items. Submission Date for this Tender is 14-03-2023. Medical Equipment Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36486811
Tender For Supply Of Consumables For Cathlab Items
Open Tender
Indian
Uttar Pradesh
Kanpur
14-03-2023

Tender Details

Supply Of Consumables For Cathlab Items-1 C Arm Cover 2 Monitor Cover 3 Plain Sheet Large 4 Sirolimus Coated Drug Eluting Ballon : Sizes: 1.5 - 4.0 Mm, Length: 10-40 Mm 5 Coronary Cutting Baloon 0.018 Compatible With Microsurgical Dilation Device 6 Rotablator Rotational Atherectomy System ( Whole Equipment ) 7 Rotablator Burr Sizes- 1.25, 1.5, 1.75, 2.0, 2.15, 2.25, 2.5 8 Rotablator - Rota Wires ( Floppy / Extra Support ) 9 Asd Device ( Titanium Nitride Coating / Platinum-Nitinol Mesh ) Quote The Prices Seprately For Device And Delivery System Compatible With Device Size: 8Mm - 42Mm 10 Pda Device ( Titanium Nitride Coating / Platinum-Nitinol / Intaglis Coating Mesh ) For All Type Of Pda Quote The Prices Seprately For Device And Delivery System Compatible With Device Size: 5 / 5 To 14 / 16 11 Left Atrial Appendage Closure Device With Disc And Lobe Design For Complete Occlusion And Sizes Available 16Mm - 30 Mm ( Euro Ce Or Dcgi Approved ) Quote The Prices Seprately For Device And Delivery System Compatible With Device 12 Pfo Device : Double-Disc Device Comprised Of Nitinol Mesh And Polyester Fabric Designed To Close All Types Of Patent Foramen Ovale ( Pfo ) 13 Multifunctional Occluder For Closure Of Muscular, Perimembranous, Post Infarct Ventricular Septal Defects, Rsov, Ap Window & Av Fistula, Should Have Low Profile, Should Come With Elongatable Waist; Quote The Prices Seprately For Device And Delivery System Compatible With Device Size: 6 - 24 Mm 14 Sizing Balloon For Asd Size: 18, 24, 34 Mm 15 Diagnostic Angiography Catheter ; Speciality Curve; Made Of High Strength Polyurethane Core And Stainless Steel Single-Wire Braiding; Extending To Tip, Having Atraumatic Soft Tip; With Winged Hub An Color Coding Band For French Size Identification, All Curves Such As Mpa, Nih, Al, Ar, Ntr, Rcb, Lcb, Hockey Stick, Ima; 4F - 6F ; Fda / Dcgi Approved 16 Diagnostic Angiography Catheter ; Speciality Curve; Made Of High Strength Pebax Material With Dual-Wire Braiding; For 1:1 Torque, Having Atraumatic Soft Tip; , All Curves Such As Mpa, Nih, Al, Ar, Ntr, Rcb, Lcb, Hockey Stick, Ima, Sones 5F-6F ; Fda / Dcgi Approved 17 Diagnostic Angiography Catheter : Radial Curve ; Suitable For Engagement For Both Left Coronary And Right Coronary From Single Catheter 5F Fda / Dcgi Approved 18 Diagnostic Angiography Wire : Teflon Coated, J Shape, 150Cm Long ; Fda / Dcgi Approved; Sizes : .032, .035, .038 19 Diagnostic Angiography Wire : Teflon Coated, St. Tip, 150Cm Long ; Fda / Dcgi Approved; Size : .032, .035, .038 20 Diagnostic Angiography Wire : Nitinol Hydrophilic Guidewire Covered With Polyurethane Containing Tungsten And A Hydrophilic Polymer Coating ( M Coat ) With High Torque Control And A Shapeable Tip 150Cm Length ; Size : .025, .035, .032; Angled Tip 21 Diagnostic Angiography Wire : Nitinol Hydrophilic Guidewire Covered With Polyurethane Containing Tungsten And A Hydrophilic Polymer Coating ( M Coat ) With High Torque Control And A Shapeable Tip 260Cm Length ; Size : .025, .035, .032; Angled Tip 22 Vascular Access Sheath : Kink Resistance; Wire Braided With Dilator And Obutrator; Length 45Cm; Size 6F-9F 23 Vascular Access Sheath : Kink Resistance; Wire Braided With Dilator And Obutrator; Length 60Cm; Size 6F-9F 24 Vascular Access Sheath : Kink Resistance; Wire Braided With Dilator And Obutrator; Length 80Cm; Size 6F-9F 25 Manifold 2 Port ; 250 Psi 26 Manifold 2 Port ; 500 Psi 27 Manifold 2 Port ; 1200 Psi 28 Manifold 3 Port 29 Puncture Needle 18G With Guidewire & Sheath In One Single Tray Packing. Rates For Different Length Different Size Must Be Quoted. Suitable For Femoral Approach 30 Puncture Needle 20G With Guidewire & Sheath In One Single Tray Packing. Rates For Different Length Different Size Must Be Quoted. Suitable For Radial Approach 31 Angiography Syringe 10Ml With Finger Rings 32 Angiography Syringe 10Ml Without Finger Rings 33 Angiography Syringe 12Ml With Finger Rings 34 Angiography Syringe 12Ml Without Finger Rings 35 High Pressure Monitoring Line Capable Of Withstanding 1200Psi 50Cm Long 36 High Pressure Monitoring Line Capable Of Withstanding 1200Psi 100Cm Long 37 High Pressure Monitoring Line Capable Of Withstanding 1200Psi 175Cm Long 38 High Pressure Monitoring Line Capable Of Withstanding 1200Psi 200Cm Long 39 Radial Compresion Band; Air Inflation Type 40 Mitral Valve Balloon Dilation Catheter; Dual Lumen ; Specially Designed Balloon, Perfectly Shaped To Fit The Mitral Valve; Short Inflation / Deflation Cycle; New Small And Soft Tip; Large Size Matrix; Longer Guide Wire To Increase Safety In Taller Patients 41 Transeptal Needle 42 Mullins Sheath 43 Pa Catheter Swanganz; Size 6F-7F 44 Avbd Balloon With Low Deflated Profiles And A Co-Axial Shaft Designed To Provide Columnar Strength And Enhance Pushability ( All Sizes ) 45 Bib Catheter An Inner Balloon 1 / 2 Of The Balloon Diameter Of The Outer Balloon; N Inner Balloon That Is 1.0 Cm Shorter Than The Outer Balloon 46 Pressure Injector Syringe 47 Ptca Perfusion Balloon 48 Radiolucent Ecg Electrode 49 Drug Eluting Stent Ce / Fda / Dcgi Approved ; Everolims Eluting Stent ( Thin Strut Design < 75 Micron ) Cobalt Chromium / Platinum Platform With Biodegradable Polymer With Established Published Scientific Evidence In Reputed International Journals. 50 Drug Eluting Stent ; Ce / Fda / Dcgi Approved; Sirolimus Eluting Stent ( Thin Strut Design < 75 Micron ) Cobalt Chromium Platform With Biodegradable Polymer; With All Sizes; Established Published Scientific Evidence In Reputed International Journals. 51 Ce Approved Non-Complaitn Coronary Balloon With Tri-Fold Layers And Tip; Entry Profile Of 0.018, Nominal Pressure Of 12 Atm And Rbp Of 18 Atm; Available In Diameter 2.0-4.5Mm And Lengths In 8Mm-25Mm 52 Workhorse Guidewire With Triple Spring 304V Stainless Steel With Niti; Distal Core And Cold Working Rotary Swaging Tip Available In Tipload; Betweeen 0.6-0.8Gm And Lengths ( 190 / 300Cm ) 53 Workhorse Guidewire With Durasteel Core, Responsease Core Grind Technology With Hydrophilic Coating And 1 Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tipload Of 0.9Gm. 54 Durasteel Gudewire With Full Polymer Coating; Variable Tipload; Between 0.8-1.2Gm Ad Variable Support. 55 Ffr Wire - 0.014 Guide Wire; High-Fidelity Piezo Electric Pressure Sensor Technology For Measurement Of Intravascular Pressure; Capable Of Wired Connection To Ffr Machine; Sensor Housing Design With Multiple Large Windows, ( Multi Window Jacket ) ; Flat Core Tip Design For A Better Shapeability & Shape Retention; Hydrophilic Coating With Radio Opaque Tip; Operating Pressure Range Of -30 To +300 Mmhg; Frequency Response Of Dc To 25Hz. 11 Should Have Radio Range Of At Least 2M; Battery Time Of Transmitter For At Least 3 Hours; Wireless Transmission Frequency Range Of 2.4000 - 2.4835 Ghz ( Ism Band ) 56 Oct Catheters- Emit Near Infrared Light To Produce High-Resolution Real-Time Images; Ompatible With 0.014 Guidewire; Outer Diameter ( Distal ) That Is Less Than 3.0 French; Usable Length Of 135 Mm; Radiopaque Markers At The Distal Tip, Imaging Lens And 50 Mm Proximal To The Lens Marker To Help Physician In Aligning Pullback To Region Of Interest; The Imaing Catheter Is Hydrophilic Coated; Rapid Exchange Tip For Guidewire Loading; The Imaging Catheter Has Shaft Markers To Notify Physician When The Distal Tip Exiting The Guide Catheter. 57 Ivus Catheter For Volcano S5 System 58 Ptca Wire- Regular Workhorse Gudewire With Tapered Elastinite Nitinol Core, Durasteel Ribbon Tip And Available In Both Hydrophilic And Hyrophobic Coatings Between Tipload 0.5-0.7Gm 59 Workhorse Guidewire With Triple Spring 304V Stainess Steel With Niti Distal Core And Cold Working Rotary Swaging Tip Available In Tipload Between 0.6-0.8Gm And Lengths ( 190 / 300Cm ) 60 Ptca Wire, Hyrophilic .014 With Polymer With Polymer Sleeve; Ht-Whisper-Durasteel Guidewire With Full Polymer Coating Available In Variable Tipload Between 0.8-1.2Gm Ad Variable Support; Ht-Pilot 50- Extra Support Durasteel Gudewire With Full Polymer Cover, Gold Marker At 4.5Cm From Distal Tip And Tipload Between 1.3 - 1.5 Gm. 61 Coronary Guide Wire- Workhorse Guidewire With Durasteel Core, Responsease Core Grind Technology With Hydrophilic Coating And 1 Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tipload Of 0.9Gm; Durasteel Gudewire With Full Polymer Coating Available In Variable Tipload Between 0.8-1.2Gm Ad Variable Support.; Ptca Gudewire With Stainless Available In Tipload Of 1Gm With Radiopaque Tip Of 3Cm.; Stainless Steel Gudewire With Intermediate Polymer Sleeve And Hyrophilic Coating Available In Tipload Between 0.6-0.7Gm With Radiopaque Tip Of 3Cm. 62 Ptca Wire With Nitinol Tip- Workhorse Guidewire With Triple Spring 304V Stainless Steel With Niti Distal Core And Cold Working Rotary Swaging Tip Available In Tipload Between 0.6-0.8Gm And Lengths ( 190 / 300Cm ) ; Regular Ptca Gudewire With Responsease Core Grind Technology And 3 Cm Palladium0-Rhenium Radiopaque Distal Tip Available In Tipload Of 0.8Gm With 190 And 300 Cm. 63 Hemeostatis Y With Stop Pull And Click Pull Types - Bleed Back Control Valve With Twin Seals: Bleed-Back Seal And Clamp Seal-Permits High Pressure Injections Up To 400 Psi. Easy Grip Push-Pull Knob For Single Operator Use And Complete Hemostasis. 64 Indeflators- The Inflation Device Should Register Pressures From Vac To 30 Atmospheres ( Vac To 441 Psi ) With A Threaded Plunger And Locking Switch Which Allow For The Generation And Sustaining Of Pressure, And A Three-Way Stopcock For Use During Preparation Of The Device And In Conjunction With Interventional Devices. 65 Ptca Wire ( Medium Support ) , All Lengths- Workhorse Guidewire With Durasteel Core, Responsease Core Grind Technology With Hydrophilic Coating And 1 Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tipload Of 0.9 Gm. 66 Ptca Wire Floppy, Intermediate, Standard Types With Different Tip Loads- Regular Workhorse Guidewire With Tapered Stainless Steel Core And Shaping Ribbon Tip Available In Tipload Of 0.6 Gm With Ptfe Coating 67 Bipolar Pacing Lead- Latex Balloon Tipped, Flow Guided For Stable Insertion; 10 Cm Depth Markers To Enhance Placement; Smooth, Polyurethane Hemocompatible Coating; Clearly Marked Terminals; Shrouded 2 Mm Pin Connector Leads, Platinum Electrodes; Flexible Tip Design For Delicate Placement. 68 Semi-Complaint Coronary Balloon- Ce Approved Semi-Complaint Coronary Balloon With Laser Bond Technology On Distal Tip With Crossing Profile Of 0.021, Tip Entry Profile Of 0.017, Nominal Pressure Of 8 Atm And Rbp Of 14 Atm Available In Diameter 1.20-4.00 Mm And Lengths 6-30Mm. 69 Non Complaint With Tri Fold Tip, Tip Entry Profile 0.018 Ce Approved Non-Complaint Coronary Balloon With Tri-Fold Layers And Tip Entry Profile Of 0.018, Nominal Pressure Of 12 Atm And Rbp Of 18Atm Available In Diameter 2.0-4.5Mm And Lengths In 8Mm-25Mm. 70 Rapid Exchange Multilayer Balloon Expandable Covered Stent- Rapid Exchange Multilayer Balloon Expandable Covered Stent With 2 Flex Stents Of 316L Stainless Steel With Spiral Link Design And Middle Layer Of Eptfe To Minimuze Foreshortening Available In Diameter : 2.8-4.8 Mm And Lengths: 16, 19, 26 71 Sku Kits With Accessories- Pack Of Accessories As A Single Sku Kit Containing One 30 Atm Capacity Inflation Device, A Bleed Back Control Valve, And Guidewire Accessories Introducer And Torquer. 72 Ptca Balloon ; Semi Compliant With Low Lesion Entry Profile Of 0.15; Suitable For Cto ; Fda / Dcgi Approved Size : 1Mm / 1.1Mm / 1.25Mm ( Sapphire Family ) 73 Ptca Balloon ; Semi Compliant Monorail Balloon With Low Lesion Entry Profile Of .017 ; Workhorse Balloon ; Size : 1.5Mm To 4Mm; Fda Approved ; 74 Non Compliant Balloon Crossing Profile 0.19 With Hydrophilic Coating On Balloon And Distal Shaft; Size 0.85 Mm Diameter And Length 6, 10, 15 Mm 75 Ptca Balloon ( Cto ) 1Mm Size 0.015 Crossing Profile 76 Ptca Balloon ( Cto ) 1.5 Mm Size With Increased Pushability 77 Non Ablsorable Haemostatic Dressing In Spounge / Pad Form Made Of 100% Natural Biopolymer With A Net Positive Charge 78 Guide Wire Hydrophilic In All Sizes 150 / 180 Cm Straight Tip Terumo Type 79 Guide Wire Hydrophilic In All Diameter, Exchange Length Straight Shaft 260 / 300 Terumo Type 80 Guide Wire Hydrophilic In All Sizes 150 / 180 Cm J Tip Terumo Type 81 Ptca Balloon Non Compliant ( Low Entry Profile ) Size 1.5 - 4.5 Mm, Super High Pressure Balloon With Crossing Profile Of 0.028 With Linear Compliance Upto 40 Atm 82 Ptca Wire For Cto Distal Tip 0.009 ( Conquest Type ) All Tip Loads 83 Ptca Wire For Cto Stainless Steel, Single Core, All Tip Loads- Gia Series 84 Ptca Wire 0.014, 300 Cm, .010 Diameter 85 Ptca Wire Distal15mm Silicontip Rope Plus Twist Technology 86 Ptca Balloon : Over The Wire Balloon, 1.5Mm , 2.0Mm, 2.5Mm Ce Approved 87 Inflation Device, With Complete Kit; Easy Grip ; Pistol Design, With Gauging > 25Atm 88 Ptca Wire Hydrophilic .014 With Distal Tapered Tip 89 Ptca Wire Hydrophilic .014 With Polymer Sleeve 90 Ptca Wire Hydrophilic .014 ( Fielder Fc Type ) 91 Ptca Wire Extra Support All Length 92 Ptca Wire Asahi ( Suoh ) 93 Cto Rapid Exchange Ptca Balloons With 0.16 Tip Entry Profile In 1 Mm To 1.5 Mm Sizes With 1.5 Mm Single Material Tip With Hybrid ( Hydro-X And Invio ) Coating. 94 Ptca Rapid Exchange Semi-Complaint Balloons With Sub-Zero Tip Technology With P-Tech Coating Having P-Tech Ss Hypotube 95 Ptca Rapid Exchange Non-Complaint Balloon Having Z Tip With Laser Velding For Zero Transition In Assorted Sizes From 1.75Mm To 5 Mm Diameter. 96 Non Complaint Scoring Balloon With Dual Wire With 0.011 Integral Wire 97 Diamond Back 360 With Glide Assist Orbital Athrectomy Device 98 Guiding Catheter; Femoral / Radial Approach; Jl, Jr, Mpa, Tiger, Voda, Hockey Stick For Left And Right System; 100Cm Length; With Kink Resistance; Having Marker Band At Distal End; With Wide Inner Lumen Of 5F - 8F; Fda / Dcgi Approved; Curve ( 3, 3.5, 4 ) 99 Aspiration Catheter With Stylet; With Full Wall Wire Braiding, Kink Resitant; With Buddy Wire Compatiblity And Large Lumen Of .044 100 Dual Lumen Micro Catheter Having Distal Shaft With Slender Flexible Tip; And Flexible And Strong Proximal Shaft 101 Microcatheter ( 0.014 Wire Compatible ) 135 Cm 102 Microcatheter ( 0.014 Wire Compatible ) 150 Cm 103 Mother And Child Catheter For Coronary Intervention 104 Cto Channel Dialater 135 Cm Length 105 Cto Channel Dialater 150 Cm Length 106 Cto Penetration Catheter 107 Dual Lumen Catheter For Side Branch Access 108 Impella Kit ( Impella Catheter, Connector Cable, Introducer Kit, Purge Cassette ) 109 Rota Console 110 Rota Link Rota Ablator Advancer 111 Rota Link Plus 112 Rotablator ( Rotational Atherectomy System ) Size: 1.25; 1.5; 1.75, 2.0 Mm 113 Ivl Intravascula Lithotripsy Intutive Catheter With Rx System For Treating Highly Calcified Lesions, Integrated 12Mm Sc Balloon, Np- 4 Atm / Rbp-10 Atm, Diameters 2.5, 3.0, 3.5, 4.0 Mm 2 Emitters ( 80 Pulses Per Catheter ) 114 Temporary Pacing Lead - 6F With Introducer Sheath 7F In Single Tray Packing To Connect External Puls Generator. 115 Coronary Snares Gooseneck Type 116 Coronary Snares Wire Loop Type 117 Bioptomes For Endomyocardial Biopsy 118 Re-Entry Catheter For Coronary Cto Including Sting Ray System 119 Otw Proximal Cerebral Protection Device With 2 Compliant Elastomeric Balloons, 8F & 9F Csi And 0.035 Wire Compatible And Shaft Length Of 95 Cm. 120 Guide Wire Amplatz Super Stiif Wire Guide-0.035-145 Cm 121 Guide Wire Amplatz Super Stiif Wire Guide-0.035-180 Cm 122 Guide Wire Amplatz Super Stiif Wire Guide-0.035-260 Cm 123 Angiographic Catheter Hydrophilic 5F 100 Cm 110 Cm All Shapes And Curves For Peripheral Angiograpy 124 Angiographic Catheter Hydrophilic 5F 100 Cm 110 Cm All Shapes And Curves For Vertebral 125 Embolisation Micro Coil Platinum 0.014” Wire All Sizes 126 Embolisation Micro Coil Platinum 0.018”Wire All Sizes 127 Embolization Microcoils Detachable Coils- .018 Regular Detachable Coils. 128 Vascular Plugs Designed To Provide Optimal Embolization Through Single Device Occlusion, Full Cross-Sectional Vessel Coverage And Controlled, Precise Deployment. Vascular Plugs Should Have The Ability To Be Recaptured And Repositioned, If Necessary. 129 Covered Stent .035 Wire Compatible Nitinol Self Expanding 130 Covered Stent .035 Wire Compatible Balloon Expandable 131 Glue N-Butyl-2-Cyanoacrylate 132 Radio-Opaque Contrast Agent; Oil Based Indicated For: Selective Hepatic Intra-Arterial Use 133 Microcatheter For Injecting Glue ( N-Butyl-2-Cyanoacrylate ) 134 Pta Balloon .035 Wire Compatible 5Mm To 12Mm Diameter Otw Type 135 Pta Balloon .035 Wire Compatible Large Diameter > 14Mm 136 Pta Balloon .018 / ..014 Wire Compatible 4Mm To 7Mm Diameter Otw Type 137 Pta Balloon .035 Wire Compatible 5Mm To 12Mm Diameter Monorail Type 138 Pta Balloon .018 / .014 Wire Compatible 4Mm To 7Mm Diameter Monorail Type 139 Pta Balloon .014 Wire Compatible Suitable For Carotid Intervention 140 Pta Balloon .035 Wire Compatible Long Length Suitable For Btk Cases 141 Embolic Protection Device ; Distal Protection Conical Filter Shape Fixed On .014 Wire 142 Embolic Protection Device ; Proximal Protection Balloon Occlusion Type 143 Embolic Protection Device Having Device System Allowing Primary Wire Movement Independent Of The Filter 144 Vascular Access Sheath For Contraletral Approach All Sizes 145 Vascular Access Sheath 45Cm With Tuohy Borst Valve 146 Vascular Access Sheath 60Cm With Tuohy Borst Valve 147 Vascular Access Sheath 90Cm With Tuohy Borst Valve 148 Vascular Access Sheath Braided For Carotid Access 149 0.018 Compatible Otw Peripheral Cutting Balloon With Microsurgical Baldes 4-8Mm, Length 15- 20 Mm – Fda / Dcgi Approved 150 Peripheral Snare Gooseneck Type 151 Large Bore Y Connector 152 Guiding Catheter Suitable For Renal Intervention 153 Guiding Catheter Suitable For Subclavian Intervention 154 Re-Entry Catheter For Cto For Peripheral Vascular 155 Connector Of Halo Catheter 156 Connectors Of Ablation Catheters ( Non-Temperature Guided ) 157 Connectors Of Ablation Catheters ( Temperature Guided ) 158 Connectors Of Diagnostic Decapolar Catheters 159 Connectors Of Diagnostic Quadripolar Catheters 160 Connectors Of Lasso Catheter 161 Ablation Catheter ( Non-Temperature Guided ) 162 Ablation Catheter ( Temperature Guided ) 163 C3 Ref Patch For 3 D Mapping 164 Circular Mapping Catheter For Pulmonary Vein Isolation 165 Decapolar Catheter ( Deflectable ) 166 Decapolar Catheter ( Fixed Curve ) 167 Dudecapolar Catheter 168 Ensite Array ( For Non-Contact Mapping ) 169 Ensite Navx Patch 170 Halo Catheter 171 Irriagted Ablation Catheter For 3 D Mapping 172 Lassocatheter 173 Mapping Catheter For 3 D Mapping 174 Navistar Thermocool 175 Non-Irrigated Ablation Catheter For 3 D Mapping 176 Patch Electrode For Rf Ablation 177 Patch Electrodes For Hands Off Defibrillator 178 Quadripolar Catheter ( Deflectable ) 179 Quadripolar Catheter ( Fixed Curve ) 180 Quadripolar Catheter ( Woven ) 181 Reflexion Spiral Catheter 182 Xp Ref Patch For 3 D Mapping 183 X-Ray Film Digital ( Di-Hl ) 14X17 100 Sheet / Pack 184 X-Ray Film Digital ( Di-Hl ) 10X12 150 Sheet / Pack 185 X-Ray Film Digital ( Di-Hl ) 8X10 150 Sheet / Pack 186 X-Ray Film 12X15 50 Sheet / Pack 187 X-Ray Film 10X12 50 Sheet / Pack 188 X-Ray Film 8X10 50 Sheet / Pack 189 X-Ray Film Fixer 190 X-Ray Film Developer 191 Omnipaque, Visipaque Iohexol - Non Ionic - 320 Mg / 50 Ml 192 Omnipaque, Visipaque Iohexol - Non Ionic - 320 Mg / 100 Ml 193 Omnipaque, Visipaque Iohexol - Non Ionic - 350 Mg / 50 Ml 194 Omnipaque, Visipaque Iohexol - Non Ionic - 350 Mg / 100 Ml 195 Iopromide 370 Mg / 100 Ml 196 Iopromide 370 Mg / 50 Ml 197 Bipolar Pacing Lead With Introducer Set 198 Drug Eluting Stent , Sirolimus Eluting, Nickle Cobalt Free ( Vasculoy ) Alloy 199 Intravascular Lithotripsy Balloon For Peripheral Use Having 5 Electrodes 200 Intravascular Lithotripsy Balloon For Coronary Use Having 2 / 3 Electrodes 201 High Pressure Dual Layer Balloon , Having High Rbp Of 35Atm 202 High Pressure .085 Balloon, With Single Marker , Having Rbp 23Atm 203 Inflation Device For High Pressure Till 55Atm 204 Femoral Vascular Access Sheath W / O Puncture Needle 4F-8F 11Cm 205 Radial Vascular Introducer Sheath 11Cm .025 Guidewire 206 Radial Vascular Introducer Sheath 5F, 6F 7Cm 207 Y Connector Push Pull Type With Detachable Side Connecting Tube 208 Inflation Device 30Atm Gun Type Grip 209 Stent For Coarctation Of Aorta; Premounted ; Covered Stent ; .013 Platinum / Iridium Wire That Is Arranged In A “Zig” Pattern, Laser Welded At Each Joint And Over Brazed With 24K Gold; Stent Covered With Ptfe Patch 210 Stent For Coarctation Of Aorta; Premounted ; Un Covered Stent ; .013 Platinum / Iridium Wire That Is Arranged In A “Zig” Pattern, Laser Welded At Each Joint And Over Brazed With 24K Gold; Stent Covered With Ptfe Patch 211 Drug Eluting Stent Zotralimus Eluting With Cobalt Chromium Platform Biostable Polymer 212 Drug Eluting Stent Zotralimus Eluting Continous Sinusoid Design Fda / Dcgi Approved 213 Drug Eluting Stent Sirolimus Eluting, Thin Struts Of 60 Micron, Having Biolute And Probio Coating, Fda / Dcgi Approved 214 Guiding Catheter; Flat Dual Braiding ; Jl, Jr, Mpa, Tiger, Voda, Hockey Stick For Left And Right System; 100Cm Length; With Kink Resistance; Having Marker Band At Distal End; With Wide Inner Lumen Of 5F ( .058 ) , 6F ( .071 ) , 7F ( .082 ) , 8F 215 Ptca Wire Workhorse .014 Sion-Tec Technology Tip Load .7 Gm 216 Ptca Wire Workhorse .014 Sion-Tec Technology Tip Load .5 Gm 217 Post Dilation Balloon For Tavi Zmed 218 Transcatheter Aortic Valve , Self Expanding Fda / Dcgi Approved With 219 Confida Wire For Tavi 220 Valve Loading Systems For Self Expanding Transcatheter Aortic Valve Fda / Dcgi Approved 221 Delivery Sytem For Self Expanding Transcatheter Aortic Valve Fda / Dcgi Approved 222 Percutaneous Heart Pump With Upto 3.5 To 4.1 L / Min Of Ventricular Unloading Non-Medicated Coronary Stent 223 Balloon Mounted, Non-Medicated Stent On Stainless Steel Platform 224 Balloon Mounted, Non Medicated Stent On Non-Stainless-Steel Platform With Uniform Ultrathin Struts ( Up To 60 Microns ) 225 Balloon Mounted, Non Medicated Stent On Non-Stainless-Steel Platform With Uniform Thin Struts ( 61-80 Microns ) 226 Balloon Mounted; Non Medicated Stent On-Stainless-Steel Platform With Strut Thickness ( >80 Microns ) 227 Balloon Mounted; Non Medicated Stent On-Stainless-Steel Platform For Coronary Artery Diameters All Sizes Including 4.5 Or More 228 Balloon Mounted; Non Medicated Stent On-Stainless-Steel Platform For Coronary Artery Disease Segment All Lengths Including 8Mm Or More Medicated Coronary Stent - Sirolimus Eluting ( Fda / Ce / Dgci Approved ) 229 Balloon Mounted, Sirolimus Eluting Stent On Non-Stainless-Steel Platform With Biodegradable Polymer Having Uniform Ultrathin Struts ( Up To 60 Microns ) And Diameters Of 2.25 To More Than 4.5 Mm And Off Varying Length With Established Published Scientific Evidence In Reputed International / National Journals. 230 Balloon Mounted, Sirolimus Eluting Stent On Non-Stainless-Steel Platform With Biodegradable Polymer Having Uniform Ultrathin Struts ( 61 To 80 Microns ) And Diameters Of 2.25 To More Than 4.5 Mm And Off Varying Length With Established Published Scientific Evidence In Reputed International / National Journals. 231 Balloon Mounted, Sirolimus Eluting Stent On Non-Stainless-Steel Platform With Biodegradable Polymer Having Uniform Ultrathin Struts ( More Than 80 Microns ) And Diameters Of 2.25 To More Than 4.5 Mm And Off Varying Length With Established Published Scientific Evidence In Reputed International / National Journals. 232 Balloon Mounted, Sirolimus Eluting Stent On Non-Stainless-Steel Platform With Biostable Polymer Having Uniform Ultrathin Struts ( Up To 80 Microns ) And Diameters Of 2.25 To More Than 4.5 Mm And Off Varying Length With Established Published Scientific Evidence In Reputed International / National Journals. 233 Drug Eluting Stent ; Ce / Fda / Dcgi Approved; Sirolimus Eluting ( Thin Strut Design <75 Micron ) ; Hybrid Design, Cobalt Chromium Platform With Biodegradable Polymer; Abluminal Coating, All Sizes With Established Published Scientific Evidence In Reputed International Journals. Medicated Coronary Stent - Everolimus Eluting ( Fda / Ce / Dgci Approved ) 234 Balloon Mounted, Everolimus Eluting Stent With Biodegradable Polymer On Non-Stainless-Steel Platform With Biodegradable Polymer Having Uniform Ultrathin Struts ( Upto 60 Microns ) And Diameters Of 2.25 Mm To 4.0 Mm Or More Of Varying Lengths With Established Published Scientific Evidence In Reputed International / National Journals. 235 Balloon Mounted, Everolimus Eluting Stent With Biodegradable Polymer On Non-Stainless-Steel Platform With Biodegradable Polymer Having Uniform Ultrathin Struts ( 61 To 80 Microns ) And Diameters Of 2.25 Mm To 4.0 Mm Or More Of Varying Lengths With Established Published Scientific Evidence In Reputed International / National Journals. 236 Balloon Mounted, Everolimus Eluting Stent With Biodegradable Polymer On Non-Stainless-Steel Platform With Biodegradable Polymer Having Uniform Ultrathin Struts ( More Than 80 Microns ) And Diameters Of 2.25 Mm To 4.0 Mm Or More Of Varying Lengths With Established Published Scientific Evidence In Reputed International / National Journals. Other Coronary Stent 237 Balloon Mounted, Dual Drug Coated Drug Eluting Stents 238 Bioresorbable Coronary Vascular Scaffold 239 Coronary Stent Graft / Coronary Covered Stent With Sandwich Design Of Variable Diameters And Lengths 240 Coronary Stent Graft / Coronary Covered Stent Of Variable Diameters And Lengths, With Single Stent Design And 5 French Guid Catheter Compatibility Peripheral Vascular Stents ( Carotid Stents Self-Expandable ) 241 Nitinol Carotid Stent, 0.014 Guide Wire Compatible, 5-10 Mm Diameter - Non Tapered 242 Nitinol Carotid Stent, 0.014 Guide Wire Compatible, 5-10 Mm Diameter - Tapered 243 Nitinol Monorail Closed Cell Design With Flared End-Stapered, 6F Sheath Compatible 244 Stainless Steel, Monorail, Self-Expandable Carotid Stent Peripheral Vascular Stents ( Carotid Stents Self-Expandable ) 245 Monorail 0.014 Wire Compatible Stainless-Steel Renal Stent Of Diameter 4-7 Mm Of Varying Lengths 246 Monorail 0.014 Wire Compatible Cobolt Chromium Renal Stent Of Diameter 4-7 Mm Of Varying Lengths 247 Monorail 0.014 Wire Compatible Cobolt Chromium Renal Stent Of Diameter 5-7 Mm Of Varying Lengths, 5F Compatible 248 Monorail 0.018 Wire Compatible Balloon Mounted Renal Stents Of Diameter 4-7 Mm Of Varying Lengths 249 Balloon Mounted, Over The Wire, Renal Stent Balloon Mounted Peripheral Stents 250 Peripheral Stainless-Steel Stent Of Diameter 5-10 Mm And Lengths 20-60 Mm 251 Peripheral Stainless-Steel Stent Of Diameter 5-10 Mm And Length 17-57 Mm 252 Peripheral Stainless-Steel Stent Of Diameter 11-14 Mm And Length 20-60 Mm 253 Peripheral Stainless-Steel Stent High Radial Strength Of Diameter 15-24 Mm 254 Peripheral Balloon Expendable Cobalt Chromium Stent With High Radial Force With Smaller Introducer Sheath, Semi Flexible Hybrid Cell Design, With Lengths From 13 Mm Up To 57 Mm & Diameter From 6 Mm Up To 32 Mm 255 Peripheral Cobalt Chromium Stent 5-10 Mm Diameter And Length 15-16 Mm 256 Peripheral Cobalt Chromium Stent With Thin Struts, Over The Wire, 0.035 Guide Wire Compatible, 6F Sheath Compatible Across All Sizes ( 7Mm To 10 Mm Diameter ) 257 Peripheral Non Balloon Mounted, Stainless Steel, Vascular Stent 258 Peripheral Non Balloon Mounted, Cobolt Chromium, Vascular Stent Self Expanding Peripheral Stents 259 Over The Wire, 0.035 Wire Compatible, Nitinol Peripheral Stent Of Diameter 5-10 Mm Of Varying Lengths 260 Over The Wire, 0.035 Wire Compatible, Nitinol Peripheral Stent Of Diameter 11-14 Mm Of Varying Lengths 261 Over The Wire, 0.035 Wire Compatible, Nitinol Peripheral Stent Of Diameter 5-14 Mm And 20-120 Mm Length 262 Over The Wire, 0.035 Wire Compatible, Nitinol Peripheral Stent Of Diameter 15-24 Mm Of Varying Length 263 Over The Wire, 0.035 Wire Compatible, Nitinol Peripheral Stent Of All Sizes And Variable Lengths 264 Over The Wire, 0.035 Wire Compatible, Self-Expandable Stent Of Braided Construction, With Higher Flexibility And Improved Compression Resistance, Of Diameter 5-24 Mm And Variable Length Peripheral Stent Grafts 265 Aortic Stent Graft Self Expandable Tubular Diameter 23 Mm Or Less And 34 Mm Or More With Delivery System. The Manufacturer Should Agree To Supply The Size Customized To The Patients Anatomy Based On Ct Imaging 266 Aortic Stent Graft Self Expandable Bifurcated Diameter 23 Mm Or Less And 34 Mm Or More With Delivery System & Contralateral Limb. The Manufacturer Should Agree To Supply The Size Customized To The Patients Anatomy Based On Ct Imaging 267 Aortic Stent Graft System For Thoracic Endovascular Aortic Repair With Delivery System. Proximal Stent Graft Diameter From 22Mm Or Less To 46 Mm Or More In Varying Lengths. The Manufacturer Should Agree To Supply The Size Customized To The Patients Anatomy Based On Ct Imaging 268 Extension Tube Graft For Aortic Stent Graft 269 Iliac Extension For Aortic Stent Graft 270 Balloon Expandable Peripheral Stent Graft Of All Diameters And Varying Lengths 271 Balloon Expandable Stent Graft With Ptfe Expandable To 24 Mm 272 Self-Expandable Peripheral Stent Graft Of All Diameters And Varying Lengths 273 Self-Expandable Covered Stent Of Diameters 6Mm-14Mm And 20-70 Mm Length 274 Self-Expandable Aortic Stent Graft Expandable To 24 Mm 275 Self-Expandable Stent Graft Expandable To 14 Mm 276 Ptfe Covered Balloon Expendable Cobalt Chromium Stent With High Radial Strengths, Of Length 18 To 57 Mm And Diameters Up To 35 Mm Peripheral Stents For Coarctation Of Aorta 277 Non Mounted Stents For Coarctation Of Aorta Length 30Mm To > 60Mm Various Diameter Of 12 Mm To > 30 Mm 278 Balloon Pre-Mounted Stents For Coarctation Of Aorta Length 30Mm To > 60Mm Various Diameter Of 12 Mm To > 30 Mm 279 Covered Stents For Coarctation Of Aorta Length 30Mm To > 70Mm Various Diameter Of Upto > 40 Mm 280 Drug Eluting Bioabsorbable Scaffold With 100 Micron Strut Thickness Made Of Plla Pacemaker 281 Pro Mri Aicd Single Chamber 1. Price Of Pulse Generator & All Type Of Matchine Endocardial And Epicardial Leads Should Be Quoted Seprating. However Rate Comparision Shall Be Done By Taking The Total Price Of All Of These. 2. Minimum Warranty Of 5 Years 282 Pro Mri Combo Device 1. Price Of Pulse Generator & All Type Of Matchine Endocardial And Epicardial Leads Should Be Quoted Seprating. However Rate Comparision Shall Be Done By Taking The Total Price Of All Of These. 2. Minimum Warranty Of 5 Years 283 Pro Mri Dual Chamber Aicd 1. Price Of Pulse Generator & All Type Of Matchine Endocardial And Epicardial Leads Should Be Quoted Seprating. However Rate Comparision Shall Be Done By Taking The Total Price Of All Of These. 2. Minimum Warranty Of 5 Years 284 Permanent Pacemaker --Vvir- Single Chamber Pacemaker Should Have Follwing Feature 1. Device Should Periodically Automatically Assess And Adjust Pacing Thresholds And Make Necessary Changes In Pacing Outputs 2. Ventricle Beat To Beat Capture Confirmation With Back-Up Pulse. 3. Passive / Active Fixation, Bipolar Lead 4. Auto Sensing 5. Auto P / R Check 6. Autoinizialization 7. Auto Threshold Check 8. Patients Lifetime Free Replacement Warranty Of Whole Device. 9. Approval Of Ce. / F.D.A. / D.C.G.I 10. Price Of Pulse Generator & All Type Of Machine Endo & Epi Cardial Leads Should Be Quoted Seprating. However Rate Comparision Shall Be Done By Taking The Total Price Of All Of These. 11. Established Published Scientific Evidence In Reputed International Journals. 285 Permanent Pacemaker --Ddd- Pacemaker Should Have Follwing Feature 1. Device Should Periodically Automatically Assess And Adjust Pacing Thresholds And Make Necessary Changes In Pacing Outputs 2. Passive / Active Fixation, Bipolar Lead 3. Over Drive Mode 4. At / Af Burden Monitoring And Atrial Overdrive Pacing For Suppression Of Atrial Arrhythmias. 5. Ventricle Beat To Beat Capture Confirmation With Back-Up Pulse. 6. Automatic And Fully Programable Atrial And Ventricle Sensitivity Settings. 7. Clinical Programming And Remote Monitoring. 8. A.V. Hysteresis 9. Retrograde Conduction Test Capability 10. Auto Mode Conversion 11. Patients Lifetime Free Replacement Warranty Of Whole Device. 12. Approval Of Ce. / F.D.A. / D.C.G.I 13. Price Of Pulse Generator & All Type Of Matchine Endocardial And Epicardial Leads Should Be Quoted Seprating. However Rate Comparision Shall Be Done By Taking The Total Price Of All Of These. 14. Established Published Scientific Evidence In Reputed International Journals. 286 Ce Approved 3 And 1.5 Tesla Whole Body Mri Conditionaldual Chamber Rate Responsive ( Dddr ) Pacemaker 1. Multi-Programmable, 3 And 1.5 Tesla Whole Body Mri Conditional Dual Chamber Rate Responsive Pacemaker 2. Active Fixation Mri Conditional Is-1 Compatible Bipolar Leads With All Accessories 3. Device Should Periodically Automatically Assess And Adjust Pacing Thresholds And Make Necessary Changes In Pacing Outputs 4. Device Should Be Able To Detect And Record Tachyarrhythmias And Store Their Electrograms 5. Patients Lifetime Free Replacement Warranty Of Whole Device. 6. Price Of Pulse Generator & All Type Of Matchine Endocardial And Epicardial Leads Should Be Quoted Seprating. However Rate Comparision Shall Be Done By Taking The Total Price Of All Of These. 7. Established Published Scientific Evidence In Reputed International Journals. 287 Permanent Pacemaker --Dddr- Pacemaker Should Have Follwing Feature 1. Device Should Periodically Automatically Assess And Adjust Pacing Thresholds And Make Necessary Changes In Pacing Outputs 2. Passive / Active Fixation, Bipolar Lead 3. Over Drive Mode 4. A.V. Hysteresis 5. Retrograde Conduction Test Capability 6. Auto Mode Conversion 7. Device Should Be Fully Programmable 8. Patients Lifetime Free Replacement Warranty Of Whole Device. 9. Approval Of Ce. / F.D.A. / D.C.G.I 10. Price Of Pulse Generator & All Type Of Matchine Endocardial And Epicardial Leads Should Be Quoted Seprating. However Rate Comparision Shall Be Done By Taking The Total Price Of All Of These. 11.Established Published Scientific Evidence In Reputed International Journals. 288 Fda Approved Single Chamber Icd 1. Multi-Programmable Single Chamber Icd 2. Active Or Passive Fixation Lead With All Accessories 3. For Comparative Analysis, Price Of The Whole Unit ( Device And Lead ) . 4. Minimum Warranty Of 5 Years 5. Price Of Pulse Generator & All Type Of Matchine Endocardial And Epicardial Leads Should Be Quoted Seprating. However Rate Comparision Shall Be Done By Taking The Total Price Of All Of These. 289 Fda Approved Combo Device- Crtd ( Biventricular Pacemaker With Defibrillator ) 1. Multi-Programmable Biventricular Pacemaker With Icd 2. Active Or Passive Fixation Leads With All Accessories 3. Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When It Is Required. 4. Must Quote Price Of Compatible Active And Passive Fixation Leads Separately For Use In Future 5. For Comparative Analysis Price Of The Whole Unit ( Pacemaker And Lead ) Will Be Taken Into Consideration 6. Minimum Warranty Of 5 Years 7. Price Of Pulse Generator & All Type Of Matchine Endocardial And Epicardial Leads Should Be Quoted Seprating. However Rate Comparision Shall Be Done By Taking The Total Price Of All Of These. 290 –Fda Approved Biventricular Pacemakers 1. Multi-Programmable Biventricular Rate Responsive Pacemaker 2. Passive / Active Fixation, Bipolar Leads 3. Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When Required. 4. Minimum Warranty Of 5 Years 5. Price Of Pulse Generator & All Type Of Matchine Endocardial And Epicardial Leads Should Be Quoted Seprating. However Rate Comparision Shall Be Done By Taking The Total Price Of All Of These. 6. Option Of Programming Multipoint Pacing For Lv Lead With Programmable Delays ( Av, Vv And Lv Intraventricular ) 7. Dynamic Av Delay Optimization 8. Choice Of Quadripolar Lead With Multiple Programmable Vectors. 291 Mri Safe Singel Chamber Vvir Pacemaker Mri Lead & Sheath With Patient Life Time Free Replacement Warranty In Pacemaker And Lead Both. Pacemaker Can Be Tested Upto 3.0 Tesla Machine. Other Items 292 Crystaline Silver Mesh Dressing With Silcryst Technology Having Sustained Release Of Silver 70-100 Ppm For 72 Hours, Made Of Rayon Polyster Mesh Sandwiched Between Polythylene Layers Binded With Ultrasonic Welds Effective Against Mrsa & Vre & Superbug. Size 10X10 Cm 293 Crystalline Silver Mesh Dressing With Solcryst Technology Having Sustained Release Of Silver 70-100 Ppm For 72 Hours, Made Of Rayon Polyster Mesh Sandwiched Between Polythylene Layers Binded With Ultrasonic Welds Effective Against Mrsa & Vre & Superbug. Size 20 X 40 Cm 294 Crystalline Silver Mesh Dressing With Silcryst Technology Having Sustained Release Of Silver 70-100 Ppm For 72 Hours, Made Of Rayon Polyster Mesh Sandwiched Between Polyethylene Layers Binded With Ultrasonic Welds Effective Against Mrsa & Vre & Superbug Size: 40X40 Cm 295 An Advanced Triple-Layer Construction Which Combines An Absorbent Hydrocellular Pad Sandwiched Between A Perforated Soft Gel Adhesive Wound Contact Layer And A Highly Permeable Water Proof Outer Film. Triple-Action Technology Absorbs, Retains, And Transpires Exudate To Provide Optimal Fluid Management Maintains Optimal Moisture Balance; Sze: 7.5 X 7.5 Cm 296 An Advanced Triple-Layer Construction Which Combines An Absorbent Hydrocellular Pad Sandwiched Between A Perforated Soft Gel Adhesive Wound Contact Layer And A Highly Permeable Water Proof Outer Film. Triple-Action Technology Absorbs, Retains, And Transpires Exudate To Provide Optimal Fluid Management Maintains Optimal Moisture Balance; Sze: 10 X 10 Cm 297 An Advanced Triple-Layer Construction Which Combines An Absorbent Hydrocellular Pad Sandwiched Between A Perforated Soft Gel Adhesive Wound Contact Layer And A Highly Permeable Water Proof Outer Film. Triple-Action Technology Absorbs, Retains, And Transpires Exudate To Provide Optimal Fluid Management Maintains Optimal Moisture Balance; Sze: 10 X 20 Cm 298 An Advanced Triple-Layer Construction Which Combines An Absorbent Hydrocellular Pad Sandwiched Between A Perforated Soft Gel Adhesive Wound Contact Layer And A Highly Permeable Water Proof Outer Film. Triple-Action Technology Absorbs, Retains, And Transpires Exudate To Provide Optimal Fluid Management Maintains Optimal Moisture Balance; Sze: 10 X 25 Cm 299 An Advanced Triple-Layer Construction Which Combines An Absorbent Hydrocellular Pad Sandwiched Between A Perforated Soft Gel Adhesive Wound Contact Layer And A Highly Permeable Water Proof Outer Film. Triple-Action Technology Absorbs, Retains, And Transpires Exudate To Provide Optimal Fluid Management Maintains Optimal Moisture Balance; Sze: 10 X 30 Cm 300 An Antimicrobial A Ssd Advanced Triple-Layer Construction Which Combines An Absorbent Hydrocellular Pad Sandwiched Between A Perforated Silicon Gel Adhesive Wound Contact Layer And A Highly Permeable Waterproof Outer Film. Triple Action Technology Absorbs, Retains, And Transpires Exudate To Provide Optimal Fluid Management Maintains Optimal Moisture Balance Size: 7.5 X 7.5 Cm 301 An Antimicrobial A Ssd Advanced Triple-Layer Construction Which Combines An Absorbent Hydrocellular Pad Sandwiched Between A Perforated Silicon Gel Adhesive Wound Contact Layer And A Highly Permeable Waterproof Outer Film. Triple Action Technology Absorbs, Retains, And Transpires Exudate To Provide Optimal Fluid Management Maintains Optimal Moisture Balance Size: 10 X 10 Cm 302 An Antimicrobial A Ssd Advanced Triple-Layer Construction Which Combines An Absorbent Hydrocellular Pad Sandwiched Between A Perforated Silicon Gel Adhesive Wound Contact Layer And A Highly Permeable Waterproof Outer Film. Triple Action Technology Absorbs, Retains, And Transpires Exudate To Provide Optimal Fluid Management Maintains Optimal Moisture Balance Size: 17.5 X 17.5 Cm 303 A Low Adherent, Absorbent Wound Dressing With Polyester Wound Contact Layer & Central Cotton / Viscose Highly Absorbent Layer; And An Outer Hydrophobic Non-Woven Layer Lowering Risk Of Exudate Strike Through & Risk Of Fibre Shed Or New Tissue Cell Growth From The Wound Into The Absorbent Pad; Size: 10 X 10 Cm 304 A Low Adherent, Absorbent Wound Dressing With Polyester Wound Contact Layer & Central Cotton / Viscose Highly Absorbent Layer; And An Outer Hydrophobic Non-Woven Layer Lowering Risk Of Exudate Strike Through & Risk Of Fibre Shed Or New Tissue Cell Growth From The Wound Into The Absorbent Pad; Size: 10 X 20 Cm 305 A Low Adherent, Absorbent Wound Dressing With Polyester Wound Contact Layer & Central Cotton / Viscose Highly Absorbent Layer; And An Outer Hydrophobic Non-Woven Layer Lowering Risk Of Exudate Strike Through & Risk Of Fibre Shed Or New Tissue Cell Growth From The Wound Into The Absorbent Pad; Size: 50 Cm X 7 Mtr 306 Transparent Conformable Moisture Vapour Permeable Polyurethane Film Preventing Sweat Accumulation During Surgery Film With Green Handles For Better Holding & Thin Film That Prevents Lateral Migration Of Skin Flora; Size 15 X 28 Cm 307 Transparent Conformable Moisture Vapour Permeable Polyurethane Film Preventing Sweat Accumulation During Surgery Film With Green Handles For Better Holding & Thin Film That Prevents Lateral Migration Of Skin Flora; Size 30 X 28 Cm 308 Transparent Conformable Moisture Vapour Permeable Polyurethane Film Preventing Sweat Accumulation During Surgery Film With Green Handles For Better Holding & Thin Film That Prevents Lateral Migration Of Skin Flora; Size 40 X 42 Cm 309 Transparent Conformable Moisture Vapour Permeable Polyurethane Film Preventing Sweat Accumulation During Surgery Film With Green Handles For Better Holding & Thin Film That Prevents Lateral Migration Of Skin Flora; Size 45 X 28 Cm 310 Transparent Conformable Moisture Vapour Permeable Polyurethane Film Preventing Sweat Accumulation During Surgery Film With Green Handles For Better Holding & Thin Film That Prevents Lateral Migration Of Skin Flora; Size 45 X 55 Cm 311 Soft, Self-Adhesive, Reusable Silicone Gel Sheet Minimum Thickness 4Mm Made From Occlusive Silicone Sheet Designed For Use In The Management Of Both Existing And New Hypertrophic Scars And Keloids; Size 12 X 6 Cm 312 Soft, Self-Adhesive, Reusable Silicone Gel Sheet Minimum Thickness 4Mm Made From Occlusive Silicone Sheet Designed For Use In The Management Of Both Existing And New Hypertrophic Scars And Keloids; Size 12 X 15 Cm 313 Amorphous Hydrogel In Applipak Composing Of 2.3% Carboxymethylcellulose 20% Propylene Glycol & Purified Water, Promotes Rapid But Gentle Debridement Of Necrotic Tissue; - 25 Gm 314 An Antimicrobial Absorbent Hydrocellular Foam Dressing For Sacral Region A Ssd Activity For 7 Days Triple Layered Structure Consisting Of Breathable, Waterproof Triple-Action Technology Polyurethane Top Film, Highly Absorbent; Size 17 X 17 Cm 315 An Antimicrobial Absorbent Hydrocellular Foam Dressing For Sacral Region A Ssd Activity For 7 Days Triple Layered Structure Consisting Of Breathable, Waterproof Triple-Action Technology Polyurethane Top Film, Highly Absorbent; Size 22 X 22 Cm 316 Battery Operated Portable Negative Pressure Wound Therapy Kit Containing 1 Device & 2 Dressings And Securing Strips; Size 10 X 40 Cm 317 Battery Operated Portable Negative Pressure Wound Therapy Kit Containing 1 Device & 2 Dressings And Securing Strips; Size 25 X 25 Cm 318 Battery Operated Portable Negative Pressure Wound Therapy Kit Containing 1 Device & 2 Dressings And Securing Strips; Size 10 X 20 Cm 319 Radial Vascular Introducer Sheath 7, 11Cm 0.021 Gyudewire 320 Femoral Vascular Access Sheath W / O Puncture Needle 4F-11F 11Cm 321 Ce Approved Non-Complaint Coronary Balloon With Three Or More Pleating And Multilayered Polyamide Balloon. Crossing Profile Of Less Than 1 Mm. Selective Hydrophilic Coating. Kink-Resistant Shaft. Tip Entry Profile Of 0.016, Nominal Pressure Of 12 Atm And Rbp Of 18 Atm; Available In Diameter 2.0-5, 0Mm And Lengths In 6Mm-30Mm 322 Hemoestatis Y With Novel Push-Pull System - Bleed Back Control Hemostatic Valve, Inner Lumen 7F Compatibility, Pressure Resistance Upto 8 At, Eashy Grip Push-Pull Knob For Single Operator Use And Complete Hemostasis. 323 Aspiration Catheter With Stylet, Rx Port With > 20Cm And Vaclok Syringe For Aspiration. Available Both In 6F & 7F, Kink Resitant; Hydrophilic Coating On Tip And Shaft, Made Of Polyetheretherketone, With Removable Core Wire, Extracting Lumen Distal Area Of 93 Mm2 324 Baloon Mounteed, Sirolimus-Eluting Stent On Cobalt Chromium Platform With A Biodegradable Polymer Having Uniform Ultrathin Struts ( 60 Microns ) Across In All Diameters Ranging From 2.00 To 4.5 Mm And Lengths 8.00-48.00 Mm. Overexpansion Limits Up To 5.50 Mm. Availability Of Quarter Sizes For Diameters Less Than 3.00 Mm. Published 3-Year Rct Data / 2Yr Meta-Analysis. Established Scientific Evidence Published In Reputed International / National Journals. Availability Of Published / Presented Data On Bigh Bleeding Risk Patients. 325 Balloon Mounted, Everolimus Eluting Stent With Biodegradable Polymer On Cobalt-Chromium Platform, Having 2 Long Dual Link With Biodegradable Polymer Having Uniform Ultrathin Struts ( 60 Microns ) In All Diameters Ranging From 2.00 To 4.5 Mm And Lengths 8.00-48.00 Mm. Overexpansion Limits Up To 5.50 Mm. Availability Of Quarter Sizes For Diameters Less Than 3.00Mm With Established Published Scientific Evidence In Reputed International / National Journals. 326 Iohexol Non-Ionic 350Mg / 100Ml, Polyproplyne Bottle 327 Iohexol Non-Ionic 350Mg / 50Ml, Polyproplyne Bottle 328 Iohexol Non-Ionic 320Mg / 50Ml, Polyproplyne Bottle 329 Iohexol Non-Ionic 320Mg / 100Ml, Polyproplyne Bottle 330 Vascular Mimetic Implant For Distal Sfa, Popliteal & Across Joints 018 Nitinol Interwoven Design Without Joints 331 Suture Mediated Vascular Closure Device, With No Re - Access Restriction, Flexibility To Pre-Close And Close Over The Wire 332 Guide Wire – 014 Dedicated Peripheral Cto Guide Wire With Various Tip Load Upto 13.5 Mg. 333 Guide Wire- 018 Stainless Support Guide Wire With Various Tip Length 3Cm / 5Cm With Shape Able Straight & J Tip. ( Steel Core Type ) 334 Guide Wire- 014 Hybrid Peripheral Guide Wire With Distal Nitinol Tip And Proximal Durasteel With 1:1 Torque 335 Guide Wire- 018 Hybrid Peripheral Guide Wire With Distal Nitinol Tip And Proximal Durasteel With 1:1 Torque. – ( Command 18 St Type ) 336 Coronary Stent Dual Drug Eluting Sirolimus+Probulcol , On Cobalt Chromium Platform 337 Coronary Stent Dual Drug Eluting Everolimus+Probulcol , On Cobalt Chromium Platform 338 Percutaneous Micro Axial Pumps That Act As Mechanical Circulatory Support ( Mcs ) 339 Catheter For Angiojet 340 Ptca Balloon 1.00Mm Dia Specially For Cto 341 Ptca Wire, 0.014 , Cto Wire With Act One Construction, Tapered Tip Options, 0.010 ( 1.7Gf Wire ) , 0.011 ( 3.5Gf Wire ) And 0.012 ( 4.5Gf Wire ) , Hydrophillic Coating 40Cm, Varying Tip Load 342 Ptca Wire, 0.014 Frontline Guide Wire With Act One Construction, Hydrophillic Coating 28Cm, Tip Load 0.7Gf, Regular Length 343 Ptca Wire 0.014 For Crossing Complex Lesion, For Cto, Tapered .014 To .009, Core To Tip Design, Tip Load 9Gf / 12Gf , Varying Length 344 Guide Extension Having Half-Pipe Technology For Smooth Device Entry 345 Microcatheter For Cto With Preshaped Tips Of 45Deg / 90Deg / 120Deg 346 Contrast Iodixanol Visipaque In Pet Bottle 320Mg / 100Ml 347 Contrast Iodixanol Visipaque In Pet Bottle 320Mg / 50Ml 348 Sirolimus Eluted Balloon 349 Thrombus Aspiration Catheter 350 Y-Connector Should Be 10Fr Inner Lumen Diameter, Suitable For A Variety Of Advanced Multi Device Techniques; Size 60 Mm; Should Be One Touch Control; The Twist And Lock Haemostatic Valve Is Easy To Use With Single Hand Operation: Should Be Minimum Bloodloss: Should Be The Fixed Valve; Should Be Prevent Of Pressure: Pressure Resistance With Fixed Valve Closed < 550 Psi 351 Fenestrated Radial Entry Shield 352 Ep Sub Clavian Shield 353 No Brainer Head Cover For Radiation Protection 354 Radiation Protection Gloves 355 Fenestrated Radial Entry Shield: Single Layer, Sterilized, Non-Pvc, Pb-Free And Light Weight Absorbable Radial Intervention Drape To Stop Scattered Radiation In Both Ap And Oblique Viewing Angles During Radial Artery Access Procedures. Must Be Ce Certified, Have Barc Test Certificate, And Lead Equivalency Should Not Be Greater Than 0.130Mmpb. Attenuation Drape Size: 406Mmx305mm. Outer Fabric Should Be Made Of Paper. Mandatory Document Must Provide: 1. Environmental Safety Documents From Notified Government Body. 2. Clinical Proof Of Attenuation At Different Procedures. 3. Patient Safety Documents. 4. Core Material Test Report. 356 Femoral Entry Angiography Shield: Single Layer, Sterilized, Non-Pvc, Pb-Free And Light Weight Absorbable Femoral Entry Drape To Stop Scattered Radiation In Both Ap And Oblique Viewing Angles During Like Multi Vessel, Cto, Angioplasty, Ep Ablation Etc Procedures. Mustbe Ce Certified, Have Barc Test Certificate, And Lead Equivalency Should Not Be Greater Than 0.130Mmpb. Attenuation Drape Size: 406Mmx356mm. Outer Fabric Should Be Made Of Paper. Mandatory Document Must Provide: 1. Environmental Safety Documents From Notified Government Body. 2. Clinical Proof Of Attenuation At Different Procedures. 3. Patient Safety Documents. 4. Core Material Test Report. 357 Ep Subclavian Shield: Single Layer, Sterilized, Non-Pvc, Pb-Free And Light Weight Absorbable Radial Multipurpose Drape To Stop Scattered Radiation In Different Viewing Angles During Cardiac Ep Devices Procedures. Mustbe Ce Certified, Have Barc Test Certificate, And Lead Equivalency Should Not Be Greater Than 0.130Mmpb. Attenuation Drape Size: 406Mmx356mm. Outer Fabric Should Be Made Of Paper. Mandatory Document Must Provide: 1. Environmental Safety Documents From Notified Government Body. 2. Clinical Proof Of Attenuation At Different Procedures. 3. Patient Safety Documents. 4. Core Material Test Report. 358 No Brainer Head Cover For Radiation Protection: Non Vinyl, Lead ( Pb ) -Free X-Ray Attenuation, Light Weight

Key Value

Document Fees
INR 1180 /-
EMD
INR 100000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail