Purchase Of Consumable General Surgical Items For One Years Rate Contract Basis Part I And Further Extendable Upto 01 Year , Purchase Of Consumable General Surgicalitems For Ctvs Department On Two Years Rate Contract Basis Part I , Silicone Tracheostomy Tube Without Cuff ( Size 3.0, 3.5, 4.0, 4.5 ) . • Siliconetracheostomy Tube • Transparent And Flexible Flange , Tracheostomy Tube With Cuff ( Size 3.0, 3.5, 4.0, 4.5, 5.0 ) • Soft Seal; Low Pressure –High Volume Cuff • Inflation Cuff Showing Internal Diameter Of Tt With Spring Loaded One Way Valve For Inflating And Monitoring Cuff Pressure • Transparent And Flexible Flange , Percutaneous Tracheostomy Tube ( Size 6.0, 7.0, 8.0, 9.0 ) • Soft Seal; Low Pressure –High Volume Cuff • Inflation Cuff Showing Internal Diameter Of Tt With Spring Loaded One Way Valve For Inflating And Monitoring Cuff Pressure • Transparent And Flexible Flange • The Obturator Should Have Hole For Guidewire , Percutaneous Tracheostomy Set With Single Dilator • Should Have Introducer Needle With Sheath. • Should Be With Tracheostomy Tube. • Should Have A Short Dilator And Guidewire. • The Guide Wire Should Have Position Markings. • Should Have Single Dilator ( White Tusk / Blue Rhino ) With Gradual • Gradation For Dilatation. • Guiding Catheter Over Which The Dilator Is Introduced. • Should Be Supplied With Essential Accessories -Scalpel, Syringe , Percutaneous Tracheostomy Dilatation Set With Forceps. • Should Have Introducer Needle With Sheath. • Should Be With Tracheostomy Tube. • Should Have A Short Dilator And Guidewire. • The Guide Wire Should Have Position Markings. • Should Have A Single Guidewire Dilating Forceps For Dilatation. • Guiding Catheter Over Which The Dilator Is Introduced. • Should Be Supplied With Essential Accessories -Scalpel, Syringe , T-Piece With Apl Valve ( Infant ) Should Be Good Quality, Light Weight, Non-Conductive Disposable T Piece With Corrugate Tubing 1.8M Circuit Length, Low Resistance, 500 Ml Bag With Apl Valve With 15F / 22F Connector, Safety Cap. , Pvc Venturi Mask With 6 Diluters ( Adult ) • Variable Venturi System To Ensure Accurate Concentrations Of Oxygen With Single Unit. • Transparent Air Entrainment Mask With Soft Anatomical Form With Adjustable Elastic Strap For Adult. • Rotating Type Connector For Patient’S Comfort. • Unique Spring Loaded Mechanism Locks Prescribed Concentration In Place Ensuring Safety And Correct Oxygen Concentrations. • 210 Cm Multichannel Tube To Ensure Continuous Flow Of Oxygen. • Non-Sterile, Individually Packed In Polybag , Pvc Venturi Mask With 6 Diluters ( Pediatric ) • Variable Venturi System To Ensure Accurate Concentrations Of Oxygen With Single Unit. • Transparent Air Entrainment Mask With Soft Anatomical Form With Adjustable Elastic Strap For Adult. • Rotating Type Connector For Patient’S Comfort. • Unique Spring Loaded Mechanism Locks Prescribed Concentration In Place Ensuring Safety And Correct Oxygen Concentrations. • 210 Cm Multichannel Tube To Ensure Continuous Flow Of Oxygen. • Non-Sterile, Individually Packed In Polybag. , Oxygen Recovery Kit • It Should Be Specially Designed Kit With ‘T’ Shaped Connector For Delivering Oxygen. • It Should Have 15 Mm Connector To Fit All Tracheal Tubes. • It Should Have Suction Port At Elbow To Facilitate Oro-Bronchial Suctioning Without Disconnecting The Patient From Oxygen Source. • It Should Have Two-Meter Long Star Lumen Tube To Enable To Connect The T-Connector With Oxygen Source. • Distal End Should Be Open For Exhaling The Waste Gases. • Should Be Sterile And Individually Packed In Peelable Pack. • Unit Should Comprise Of: ‘T’ Shape Connector & Two Meter Long Tube. , Bite Block Size 4: Bite Block Size 4 For Oral Fixation Of Ett Size 6.5-8.0Mm, Laryngeal Tube Size 2 & 2.5 Tube Should Clip Into The Bite Block For Protection Against Occlusion , Bite Block Size 5 :-Bite Block Size 5 For Oral Fixation Of Ett Size > 8.5Mm, Laryngeal Tube Size 2 & 2.5 Lma 2 & 2.5 Tube Should Clip Into The Bite Block For Protection Against Occlusion. , Bite Block Size 6: Bite Block Size 6 For Oral Fixation Of Laryngeal Tube Size 3, 4, &5 And Lmas, Tube Should Clip Into The Bite Block For Protection Against Occlusion. , Disposable Ventilator / Breathing Circuit With Heater Wire ( Adult ) • Should Be Light Weight And Flexible To Minimize Drag On Circuits, • Corrugated High Quality ( Ethylene Vinyl Acetate ) Eva Material Tubings • Color Coded Heated Inspiratory Limb, 1.5M ( 22 Mm ) • Silver Impregnated 0.5M Humidifier Connection Tube, • Expiratory Limb With Water Trap 1.8 M • Autofill Humidification Chamber • Standard Y Piece • Angle Connector With Gas Sampling Port • Water Trap • Free From Phthalates And Latex , Disposable Ventilator / Breathing Circuit With Heater Wire ( Paed ) • Should Be Light Weight And Flexible To Minimize Drag On Circuits, • Corrugated High Quality Eva ( Ethylene Vinyl Acetate ) Material Tubings • Color Coded Heated Inspiratory Limb, 1.5M ( 22 Mm ) • Silver Impregnated 0.5M Humidifier Connection Tube, • Expiratory Limb With Water Trap 1.8 M • Autofill Humidification Chamber • Standard Y Piece • Angle Connector With Gas Sampling Port • Water Trap • Free From Phthalates And Latex , Disposable Chamber For Bal Collection With Adapter • Disposable Sterile Container For Bronchoscopy Application. , Nasojejunal Tube 12 Fr, 14Fr, 16 Fr • Sterile, Nasojejunal Tube, Single Use Only • Medical-Grade Silicone Construction • Latex And Dehp Free • High Performing Anti-Reflux Valve • Radiopaque Striping • Length 120 Cm , Patient Warming Blanket ( Adult ) Body Full Size: ( 206X87cm ) • ( Adult ) Body Full Size: ( 206X87cm ) • Should Be Disposable And Two Layered; • Should Consist Of Non-Woven Propylene Fabric For Body Warming. • Should Be Usable With Forced Air Warming Units. • Material Should Be Latex Free And Should Meet Flammability Standard 16 Cpr 1610 For Safety. • Should Be Compatible With Common Machines , Patient Warming Blanket ( Paediatric ) Full Body ( 100X120cm ) • ( Paediatric ) Full Body ( 100X120cm ) • Should Be Disposable And Two Layered; • Should Consist Of Non-Woven Propylene Fabric For Body Warming. • Should Be Usable With Forced Air Warming Units. • Material Should Be Latex Free And Should Meet Flammability Standard 16 Cpr 1610 For Safety. • Should Be Compatible With Common Machines , Enteral Feeding Bag ( Dehp Free ) • Enteral Feeding Bag Intended For Gastro-Intestinal Feeding.1-1.5 Litre Capacity Bag. • Ice Pouch Should Be Provided On The Rear Side Of The Bag For Preserving The Food For Longer Intervals Of Time. • Transfer Set Should Be Directly Connected To The Bag. • Roller Controller Should Be Provided On The Transfer Set Facilitates Control On The Administered Feed. • The Feeding Bag Should Be Graduated To Determine Precisely The Quantity Of The Administered Feed. • Feeding Bagshould Be Provided With A Closure Cap Anda Hanger For Safe Hanging During And After Use. • Sterile, Individually Packed In Peelable Pouch. , Tenckhoff Soft Pd Catheteradult • 15 Fr Tenckhoff Catheter, Catheter Length 37 Cm; • Side Ports 20 • Curved Tip Guide Wire • Introducer 16 Fr; 17 Cm • Sheath Length 10 Cm • Distal Tip To Cuff Distance 16.5 Cm • Scalpel Blade