}

Tender For Providing Supply, Erection, Testing And Commissioning Of Hvac, aurangabad-Maharashtra

Government Departments has published Tender For Providing Supply, Erection, Testing And Commissioning Of Hvac. Submission Date for this Tender is 09-03-2023. Coats and Jackets Tenders in aurangabad Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

36331290
Tender For Providing Supply, Erection, Testing And Commissioning Of Hvac
Open Tender
Indian
Maharashtra
Aurangabad
09-03-2023

Tender Details

Providing Supply, Erection, Testing And Commissioning Of Hvac , Providing Supply, Erection, Testing And Commissioning Of Hvac , Supply, Installing & Commissioning Ceiling Suspended Compact Ahu-Condensing Unit Air-Cooled Ducted Air Conditioner Unit Comprising Of Scroll Compressor Based On R410a Refrigerant Air-Cooled Condenser With Caklit Lcd Display Of 5.5+5.5=11 Tr / 11 Tr Nominal Capacity Having Compact, Slim & Sleek Evaporating Units Made Of Crca Steel Body Duly Powder Coated, Coils Having Inner Grooved Copper Tubes, External Motor Driven Fans Having Low Noise Levels And Condensing Unit Powder Coated For Corrosion And With Inner Grooved Copper Tubes, Hermetic Scroll Compressors Running On 3Ph Power Supply, In-Built Interlock Safety Features Such As Lp, Hp Etc. With Complete Installation Of The System With First Charge Of R410a, Required Length Interconnected Cabling Between Interconnected Control Cabling From Indoor Unit And Outdoor Unit Having Electronic Digital Temperature Management & Control System With Display. Along With Valve Station & Expansion Valve Complete All As Specified And Directed By , Supply, Installing & Commissioning Ceiling Suspended Compact Ahu-Condensing Unit Air-Cooled Ducted Air Conditioner Unit Comprising Of Scroll Compressor Based On R410a Refrigerant Air-Cooled Condenser With Caklit Lcd Display Of 8.5 Tr Nominal Capacity Having Compact, Slim & Sleek Evaporating Units Made Of Crca Steel Body Duly Powder Coated, Coils Having Inner Grooved Copper Tubes, External Motor Driven Fans Having Low Noise Levels And Condensing Unit Powder Coated For Corrosion And With Inner Grooved Copper Tubes, Hermetic Scroll Compressors Running On 3Ph Power Supply, In-Built Interlock Safety Features Such As Lp, Hp Etc. With Complete Installation Of The System With First Charge Of R410a, Required Length Interconnected Cabling Between Interconnected Control Cabling From Indoor Unit And Outdoor Unit Having Electronic Digital Temperature Management & Control System With Display. Along With Valve Station & Expansion Valve Complete All As Specified And Directed By , Supply, Installing & Commissioning 300 Cfm Energy Recovery Ventilator /Heat Recovery Unit With Blower For Supply And Exhaust Air, Heat Recovery Wheel Capable Of Sensible As Well As Latent Heat Recovery Of Minimum 65%, With All Necessary Accessories Such As Filter, Damper, Acceess Door Etc. , Supply, Installing & Commissioning 200 Cfm Energy Recovery Ventilator /Heat Revovery Unit With Blower For Supply And Exhaust Air, Heat Recovery Whell Capable Of Sensible As Well As Latent Heat Recovery Of Minimum 65%, With All Necessary Accessories Such As Filter, Damper, Access Door Etc. , Sitc Of Refrigerant Piping For Ahu Units Between Indoor & Outdoor Units (Pair Of Suction And Discharge) & Thermal Insulation Of Closed Cell Nitrile Rubber With Antimicrobial And Antifungal Properties. Piping Inside Occupied Spaces Shall Be Supported. Suction Line Should Be Covered With 19 Mm Nitrile Rubber Insulation. All The Exposed Cu Piping On Shaft Must Be Covered With Factory Laminated Glass Cloth Covering Shall Be 275 +/- 25 Kg / 50 Mm (Min), Thickness Shall Be 0.18 Mm / 7 Mil & Shall Be Uv Resistant For Artificial Weathering As Per En Iso 4892-2 Method - A. Thickness Of Glass Cloth Shall Be 0.18Mm/7 Mil. Consisting Of 5/8 & 1 1/8 Dia Copper Pipe With Insulation. , Providing Vacuumizing The Airconditioner System To 200 Micron And Charging With R-410A/ Green Refrigerant Gas For Air Conditioning Unit. , Supplying And Erecting Gi Sheet 0.6 Mm (24 Swg) Having Zinc Coating Of 275 Microns With Galvanization Process Compliance To Is 2629:1985 To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. And Painting With One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint. , Supply & Fixing Of Acoustic Insulation For Supply Air Duct Using 12/15 Mm Thick Class 1 Rating Open Cell Nitrile Rubber Elastomeric Insulation With Density Of 140 - 180 Kg / M³. The Insulation Manufactured As Per Bs 476 Part 7 & Which Should Also Meet Ul 94Test Supplementary Materials For Air Distribution System Which Should Not Absorbs Less 0.2% Water By Volume (Astm C 209), Should Not Support Microbial Growth (Astm 2180, G21, G22) And Should Not Emit Objectionable Odors (Astm C 665) And Should Have Thermal Conductivity Of 0.04W/M K @ 20 Degc As Per Din En 12667. And Water Vapor Permeance Of 0.10. Adhesive Shall Be Used Additionally With Voc Level Not Exceeding 50 Grms / Litre. , Supply & Fixing Of Thermal Insulation For Supply Air Duct & Return Air Duct 19 Mm Thick Class O Closed Cell Nitrile Rubber Based Microban Antimicrobial Product Production Elastomeric Insulation With The Density Of 40 - 55 Kg/M³. The Insulation Manafactured As Per Bs 476 Part 7Test & Which Should Also Meet Ul94 Supplementary Materials For Air Distribution System Which Should Not Absorbs Less 0.2% Water By Volume (Astm D 1056), Should Not Support Microbial Growth (Astm D2180, G21, G22) And Should Not Emit Objectionable Odors (Astm C 665) And Should Have Thermal Conductivity Of 0.033W/M.K @ 0Deg C As Per Din En 12667. And Water Vapor Permeance Of 0.10. Joints Should Be Sealed With 50 Mm Wide 3 Mm Thick Self Adhesive Tape (Black Cotton Tape Not Acceptable). Adhesive Shall Be Used Additionally With Voc Level Not Exceeding 50 Grms / Litre. ( All Insulation Should Be Laying By Internally ). , Supply & Installation Of Fire Proof Canvas Connection For Units. Canvas Connector Should Be Silicon Coated Both Side, And Canvas Shall Be Thermally Rated For 2 Hours. , Supply, Installation, Testing And Commissioning Of Manually Operated, Opposed Blade, Duct Mounted, Flanged Volume Control Dampers Of Required Sizes In Gi Construction Complete With Operating Mechanism, Mounting Arrangement, Rubber Refrigerant Kits Etc. Complete. , Supplying And Erecting Flat Flexible 4 Core 1.5 Sq Mm Pvc Sheathed Copper Cable Suitably Clamped At Fixed Intervals. , Supplying And Erecting Flat Flexible 6 Core 1.5 Sq Mm Pvc Sheathed Copper Cable Suitably Clamped At Fixed Intervals. , Supplying And Erecting Flat Flexible 4 Core 2.5 Sq Mm Pvc Sheathed Copper Cable Suitably Clamped At Fixed Intervals. , Supplying And Erecting Flat Flexible 3 Core 4 Sq Mm Pvc Sheathed Copper Cable Suitably Clamped At Fixed Intervals. , Supplying And Erecting Gi Wire Of 14 Guage Of High Purity Of Required Sizes Used For Earthing On Wall With Necessary G. I. Clamps Fixed On Wall/Cable/ Conduit With Screws Complete. , Supplying And Erecting Iron Work, Sheet Metal Work Consisting Of Crca Sheets, Various Sections Of Iron, Plates, Chequered Plates, Rods, Bars, Ms Pipes, Etc. For Panel Board Or Any Other Purpose With Bending, Cutting, Drilling And Welding Complete Erected At The Position With Necessary Materials Duly Painted With One Coat Of Red Oxide And Two Coats Of Enamel Paint To Match The Switchgears Or As Per Directions By The Authority. , Supplying And Erecting Aluminium Powder Coated Lineargrill Of Suitable Size For Width Length Withcollar Dampers Having Matching Colour With The Existing False Ceiling And Suitable For Deflection Of 15/30/45 Degree. , Supply And Erecting Electrical Control Panel For Operation Of 2 Nos 11Tr And 1 Nos 8.5 Tr Consisting Of One Nos Incomer 100 Amp And Outgoing 63 Amp For Ahu/Idu And Odus Along With Ammeter, Voltmeter, Selector Switch, Indicating Lamp And Suitable Internal Wiring And Required Controls Such As Contractor And Other Controls Required For Operating Of Ac System Idu & Odu With Required Panel Fabrication From 16Swg Ms Sheet Metal With Powder Coating Required Panel Support Structure Can Be Self-Standing/ Wall Mounting As Required As Per Site Condition Or All Required Switchgear, Mcb, Mccb, Elcb Ect As Per Ac Manufacturers Requirements.

Key Value

Document Fees
INR 5000 /-
EMD
INR 80000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail