Tender For Annual Maintenance Contract For Reep Instrument, matikhalo-Odisha

Boards / Undertakings / PSU has published Tender For Annual Maintenance Contract For Reep Instrument. Submission Date for this Tender is 03-03-2023. Couplers Tenders in matikhalo Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

36218019
Tender For Annual Maintenance Contract For Reep Instrument
Open Tender
Indian
Odisha
Matikhalo
03-03-2023

Tender Details

Annual Maintenance Contract For Reep Instrument- 1 Laying, Dressing, Termination, Ferruling Of Instrument Cable ( Power / Signal ) On Cable Tray / Supports. Including & Up To 2.5 Sq Mm 7 Core 2 Laying, Dressing, Termination, Ferruling Of Instrument Cable ( Power / Signal ) On Cable Tray / Supports. Above 7 Core & Up To 2.5 Sq. Mm 24 Core. 3 Fixing / Replacement Of Instrument Cable Tray ( Gi / Frp ) With Necessary Support Works. This Includes Bends, Coupler Plates, Suitable Fasteners & Welding, Cutting Of Supports / Ms Angles, Fixing On Walls Etc. As Directed By Eic. Size – 50 To 200 Mm, Perforated Type, 300 To 600 Mm, Ladder / Perforated Type. 4 Fabrication Of M.S. Pipes / Cs Pipes ( Seamless ) / Hdpe With Necessary Jointing System With Flange, Nipple, Distribution Header Etc. This Includes Fixing The Pipeline Sizes As Mentioned Including Cutting, Joint Welding 15 To 100 Nb With 2 Coat Epoxy Paint. 5 Fabrication Of Frames / Structural Support / Roof / Cover For Installation Of Instruments .This Includes Welding, Cutting Of Supports / Ms Angles, Fixing On Walls. With 2 Coat Epoxy Paint. 6 Fixing / Replacement / Handling Of Instrument Control Valve And Wiring And Testing .Size 15 To 150 Mm Flanged / Threaded Type. 7 Fixing / Replacement / Handling Of Instrument Flow Meter And Wiring And Testing .Size 15 To 150 Mm Flanged / Threaded Type. 8 Fixing / Replacement / Handling Of Instrument Level Sensor And Wiring And Testing .Size 15 To 80 Mm Flanged / Threaded Type. 9 Fixing / Replacement / Handling Of Instrument Pressure Transmitter / Guages And Wiring And Testing .Size 15 To 80 Mm Flanged / Threaded Type. 10 Fixing / Replacement / Handling Of Instrument Rtd / Thermocouple / Thermowell, Wiring And Testing .Size 300 To 2500 Mm Length Flanged / Threaded Type. 11 Fixing / Replacement / Handling Of Digital Panel Meter / Pid Controller / Transmitter And Wiring And Testing .Size 15 To 80 Mm Flanged / Threaded Type. 12 Fixing / Replacement / Handling Of Solenoid Valve / Pneumatic Cylinder And Wiring And Testing Flanged / Threaded Type. 13 Repair And Testing Of Instrument Control Valve.Size 15 To 150 Mm Flanged / Threaded Type. 14 Repair And Testing Of Instrument Flow Meter.Size 15 To 150 Mm Flanged / Threaded Type. 15 Repair And Testing Of Instrument Level Sensor. Size 15 To 80 Mm Flanged / Threaded Type. 16 Repair And Testing Of Instrument Pressure Transmitter / Guages .Size 15 To 80 Mm Flanged / Threaded Type. 17 Repair And Testing Of Instrument Rtd / Thermocouple / Thermowell.Size 300 To 2500 Mm Length Flanged / Threaded Type. 18 Repair And Testing Of Digital Panel Meter / Pid Controller / Transmitter. Size 15 To 80 Mm Flanged / Threaded Type. 19 Repair And Testing Of Solenoid Valve / Pneumatic Cylinder And Wiring And Testing Flanged / Threaded Type. 20 Maintenance Of Ups 6 Kva: Blowering And Cleaning, Dedusting Of Ups. Checking Voltage And Earthing And Terminal Tightness Of Each Components I.E Mcb, I / O Terminals, Fuse Etc. Checking The Voltage Restoring The Normal Working Condition. Maintenance Work To Be Carried Out As Per Direction Of Eic 21 Maintenance Of Ups 20 Kva: Blowering And Cleaning, Dedusting Of Ups. Checking Voltage And Earthing And Terminal Tightness Of Each Components I.E Mcb, I / O Terminals, Fuse Etc. Checking The Voltage Restoring The Normal Working Condition. Maintenance Work To Be Carried Out As Per Direction Of Eic 22 Maintenance Of Battery 92 Nos: Blowering And Cleaning, Dedusting Of Ups. Checking Voltage And Earthing And Terminal Tightness Of Each Components I.E Mcb, I / O Terminals, Fuse Etc. Check The Voltage Of The Each Battery With Final Output Reading .Replacing The Faulty Component Like Mcb, I / O Terminals, Fuse, Battery. Checking The Voltage Restoring The Normal Working Condition. Maintenance Work To Be Carried Out As Per Direction Of Eic. 23 Maintenance Of Plc: Blowering And Cleaning, Dedusting Of Plc.Checking Voltage And Earthing And Terminal Tightness Of Each Components I.E. Mcb, I / O Terminals, Fuse, Plc Modules, I / O Modules. Repair / Replacing The Faulty Component Like Mcb, I / O Terminals, Fuse, Plc Modules, I / O Modules / Wiring. Maintenance Work To Be Carried Out As Per Direction Of Eic . 24 Maintenance Of Compressor : Blowering And Cleaning, Dedusting, Lubrication Of Cylinder, Blow Down Etc .Checking Voltage And Earthing And Terminal Tightness Of Components I.E Mcb, Terminals, Fuse, Etc.Repair / Replacing The Faulty Component Like Mcb, I / O Terminals, Fuse, Controller Etc. Checking The Voltage Restoring The Normal Working Condition. Maintenance Work To Be Carried Out As Per Direction Of Eic. 25 Maintenance Of Dryer: Blowering And Cleaning, Dedusting Of Dryer, Lubrication Of Cylinder, Blow Down Etc .Checking Voltage And Earthing And Terminal Tightness Of Dryer Components I.E Mcb, Terminals, Fuse, Etc.Repair / Replacing The Faulty Component Like Mcb, I / O Terminals, Fuse, Etc. Checking The Voltage Restoring The Normal Working Condition. Maintenance Work To Be Carried Out As Per Direction Of Eic. 26 Preventive & Maintenance Of Instrument Control Valves: Blowering And Cleaning, Dedusting / Covering And Lubrication Of Control Valve, Check The Supply / Signal 4- 20Ma .Checking The Operation Of The Control Valve And Also Operation From The Control Room. Maintenance Work To Be Carried Out As Per Direction Of Eic. 27 Preventive & Maintenance Of Flowmeter With Transmitter: Blowering And Cleaning, Dedusting / Covering And Terminal Tightness, Check The Supply / Signal 4-20Ma .Checking The Operation And Also Operation From The Control Room.Maintenance Work To Be Carried Out As Per Direction Of Eic. 28 Preventive & Maintenance Of Level Sensor / Switch With Transmitter: Blowering And Cleaning, Dedusting / Covering And Terminal Tightness, Check The Supply / Signal 4-20Ma.Checking The Operation And Also Operation From The Control Room. Maintenance Work To Be Carried Out As Per Direction Of Eic. 29 Preventive & Maintenance Of Solenoid Valve / Pneumatic Cylinder: Blowering And Cleaning, Dedusting / Covering And Terminal Tightness, Check The Supply / Signal 4-20Ma .Checking The Operation And Also Operation From The Control Room. Maintenance Work To Be Carried Out As Per Direction Of Eic. 30 Preventive & Maintenance Of Pressure Gauge / Pressure Transmitter: Blowering And Cleaning, Dedusting / Covering And Terminal Tightness, Check The Supply / Signal 4-20Ma .Checking The Operation And Also Operation From The Control Room. Maintenance Work To Be Carried Out As Per Direction Of Eic. 31 Preventive & Maintenance Of Digital Panel Meter / Timer / Pid Controller / Lip: Blowering And Cleaning, Dedusting / Covering And Terminal Tightness, Check The Supply / Signal 4-20Ma .Checking The Operation And Also Operation From The Control Room. Maintenance Work To Be Carried Out As Per Direction Of Eic. 32 Preventive & Maintenance Of Ash Handling System: Blowering And Cleaning, Dedusting / Covering And Terminal Tightness, Check The Supply / Signal 4-20Ma .Checking The Operation And Also Operation From The Control Room.Maintenance Work To Be Carried Out As Per Direction Of Eic. 33 Preventive & Maintenance Of Tsp Bagging System: Blowering And Cleaning, Dedusting / Covering And Terminal Tightness, Check The Supply / Signal 4-20Ma / Calibration With Test Weight .Checking The Operation. Maintenance Work To Be Carried Out As Per Direction Of Eic. 34 Preventive & Maintenance Of Ball Mill Weigh Machine: Blowering And Cleaning, Dedusting / Covering And Terminal Tightness, Check The Supply / Signal 4-20Ma / Calibration With Test Weight .Checking The Operation. Maintenance Work To Be Carried Out As Per Direction Of Eic. 35 Preventive & Maintenance Of Boiler Belt Weigher: Blowering And Cleaning, Dedusting / Covering And Terminal Tightness, Check The Supply / Signal 4-20Ma / Calibration With Test Weight .Checking The Operation. Maintenance Work To Be Carried Out As Per Direction Of Eic 36 Preventive & Maintenance Of Rechloride Bagging System: Blowering And Cleaning, Dedusting / Covering And Terminal Tightness, Check The Supply / Signal 4-20Ma / Calibration With Test Weight .Checking The Operation. Maintenance Work To Be Carried Out As Per Direction Of Eic. 37 Fixing / Replacement / Testing And Calibration / Dedusting / Cleaning / Covering / Wiring Of Belt Weigher / Weighing Machine / Load Cell With Standard Weight / Standard Chain. Maintenance Work To Be Carried Out As Per Direction Of Eic . 38 Fixing / Replacement / Testing / Dedusting / Cleaning / Covering / Wiring Of Fire Alarm System / Cctv Camera. Maintenance Work To Be Carried Out As Per Direction Of Eic .

Key Value

Document Fees
Refer document
EMD
INR 66021.0 /-
Tender Value
INR 66.02 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail