Supply Of Mv Switchgear (Drawout Type) Supply Of Mv Switchgear (Drawout Type)For Numaligarh Refinery Expansion Project , Mv Switchgear 415V, 1000 A, 50Ka (1 Sec) Nrep Main Substation (Ss#10): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 1000A, 50Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 50Ka (1 Sec) Nrep Main Substation (Ss#10): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 50Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 50Ka(1 Sec) Nrep Main Substation (Ss#10): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 50Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 800 A, 50Ka (1 Sec) Nrep Main Substation (Ss#10): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 800A, 50Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 50Ka (1 Sec) Nrep Main Substation (Ss#10): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 50Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 800 A, 50Ka (1 Sec) Utility Substation (Ss#13): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 800A, 50Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 65Ka (1 Sec) Utility Substation (Ss#13): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 65Ka (1 Sec) Utility Substation (Ss#13): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 65Ka (1 Sec) Utility Substation (Ss#13): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 1000 A, 65Ka (1 Sec) Etp & Cooling Tower Substation (Ss#14): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 1000A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 1000 A, 65Ka (1 Sec) Etp & Cooling Tower Substation (Ss#14): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 1000A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr , Mv Switchgear 415V, 1000 A, 65Ka (1 Sec) Etp & Cooling Tower Substation (Ss#14): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 1000A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr , Mv Switchgear 415V, 800 A, 65Ka (1 Sec) Etp & Cooling Tower Substation (Ss#14): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 800A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 65Ka (1 Sec) Etp & Cooling Tower Substation (Ss#14): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 65Ka (1 Sec) Etp & Cooling Tower Substation (Ss#14): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 65Ka (1 Sec) Etp & Cooling Tower Substation (Ss#14): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 4000 A, 65Ka (1 Sec) Etp & Cooling Tower Substation (Ss#14): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 4000A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 4000 A, 65Ka (1 Sec) Etp & Cooling Tower Substation (Ss#14): Mv Switchgear - 415 V Ac, 3Ph, 4W, 50Hz, 4000A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 1600 A, 65Ka (1 Sec) Etp & Cooling Tower Substation (Ss#14): Mv Switchgear – 415 V Ac, 3Ph, 4W, 65Hz, 1600A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 1250 A, 65Ka (1 Sec) Offsites-I Substation (Ss#17): Mv Switchgear – 415 V Ac, 3Ph, 4W, 50Hz, 1250A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 4000 A, 65Ka (1 Sec) Offsites-I Substation (Ss#17): Mv Switchgear – 415 V Ac, 3Ph, 4W, 50Hz, 4000A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 4000 A, 65Ka (1 Sec) Offsites-I Substation (Ss#17): Mv Switchgear – 415 V Ac, 3Ph, 4W, 50Hz, 4000A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 65Ka (1 Sec) Offsites-I Substation (Ss#17): Mv Switchgear – 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 800 A, 65Ka (1 Sec) Offsites-Ii Substation (Ss#18): Mv Switchgear – 415 V Ac, 3Ph, 4W, 50Hz, 800A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 65Ka (1 Sec) Offsites-Ii Substation (Ss#18): Mv Switchgear – 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 65Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 3150 A, 50Ka (1 Sec) Offsites-Ii Substation (Ss#18): Mv Switchgear – 415 V Ac, 3Ph, 4W, 50Hz, 3150A, 50Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 800 A, 50Ka (1 Sec) Offsites-Ii Substation (Ss#18): Mv Switchgear – 415 V Ac, 3Ph, 4W, 50Hz, 800A, 50Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 800 A, 50Ka (1 Sec) Cdu/Vdu Substation (Ss#15): Mv Switchgear – 415 V Ac, 3Ph, 4W, 50Hz, 800A, 50Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchgear 415V, 1600A, 50Ka (1 Sec) Switchyard Substation (Ss#21): Mv Switchgear – 415 V Ac, 3Ph, 4W, 50Hz, 1600A, 50Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr , Mv Switchgear 415V, 2000A, 50Ka (1 Sec) Mcr-2 (Dcu): Mv Switchgear – 415 V Ac, 3Ph, 4W, 50Hz, 2000A, 50Ka For 1 Sec, Draw-Out Type As Per Sld, Feeder List & Tender Documents Attached With Mr , Special Tools And Tackles For The Entire Package For Erection, Installation, Testing, Commissioning, Operation & Maintenance As Per Oem Recommendations As Per Manufacturer’S Recommendation , Pre-Commissioning / Commissioning / Start-Up Spare Parts For Entire Mv Switchboards - 415V As Per Manufacturer’S Recommendation , Training To 2 Nos. Of Owner Personnel At Oem’S Factory For 1 Week For The Entire Package (Including Condition Monitoring). , Training To 10 Nos. Of Owner Personnel At Nrep Site For 1 Week For The Entire Package (Including Condition Monitoring). , Supervision Services For Installation, Testing And Commissioning For The Entire Package And Commissioning / Support Engineer From Oem Shall Be Stationed At Nrep Site For The Duration Of 1 Month From The Date Of Commissioning & Handover For The Entire Package , Cost For Additional Warranty Period Of 24 Months After Commissioning Or 36 Months After Dispatch Whichever Is Earlier”As Per Note 12.