}

Tender For Supply, Erection Of Pre-Fab Insulated Partition For Dna Barcoding Building At Dr.Babasaheb Ambedkar Marathwada University Aurangabad., aurangabad-Maharashtra

Dr. Babasaheb Ambedkar Marathwada University has published Tender For Supply, Erection Of Pre-Fab Insulated Partition For Dna Barcoding Building At Dr.Babasaheb Ambedkar Marathwada University Aurangabad.. Submission Date for this Tender is 09-03-2023. Miscellaneous Fasteners Tenders in aurangabad Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

36179194
Corrigendum : Tender For Supply, Erection Of Pre-Fab Insulated Partition For Dna Barcoding Building At Dr.Babasaheb Ambedkar Marathwada University Aurangabad.
Open Tender
Indian
Maharashtra
Aurangabad
09-03-2023

Tender Details

Supply, Erection Of Pre-Fab Insulated Partition For Dna Barcoding Building At Dr.Babasaheb Ambedkar Marathwada University Aurangabad. Supply, Erection Of Pre-Fab Insulated Partition For Dna Barcoding Building At Dr.Babasaheb Ambedkar Marathwada University Aurangabad. , Supply, Erection Of Pre-Fab Insulated Partition For Dna Barcoding Building At Dr.Babasahebambedkar Marathwada University Aurangabad. , Wall Panel & Partition Panel 50 Mm Thick Pufinsulated Thick Panel With 0.45Mm Ppgi Sheet Both Sides In 40±2 Kg Density. Puf Panel Shall Bemanufactured By Using High Quality Huntsmans Chemicals & N Pantane As A Blowing Agent. Thepu Panel Shall Be Cfc Free And Zero Ozonedepleting Panel Made Out Of Continuous Line Running On Uninterrupted Power Supply. Panel Shall Have Pre Coated Gisheet On Both Side Of Polyurethane Foam Confirming To Is 12436:1988. The Pre Coated Sheet Shall Be Ofminimum 240 Mpa Steel Grade Confirming To Is 14246:1995 And Shall Have Zinc Coating Of Minimum 120Gsm As Per Is : 277 : 1992, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Micron. The Ppgi Sheet Shall Have Plastic Protective Guard Film Of Minimum 25 Microns To Avoid Scratches During Transportation. The Panels Shall Be Vertically Joined Together By Tongue And Groove Joints. The Pu Foam Shall Be Self-Extinguishing, Fire Retardant Type Having Minimum Density Of 40 Kg/Cu.Mt (+, -2 Kgs). Partition Windows Should Be Provided As Per Requirement. , Supplying And Erecting Prefabricated Door For Labortory Puf Insulated Room Complete Air Tight Of Size 1.7 M (W) X 2.1M (H) Made From 0.5 Mm Thick P.P. Sheet On Both Sides Having Sandwiched Puf Insulation Of 40 Kg/Mtr Cube Density, Thermal Conductivity Less Than 0.02 Wb/Mtr Cube And 50 Mm Thickness Complete Installing Alongwith The Door Frame Firmly To The Cold Room Panels Having Non Corrosive Handles, Locks, Hinges, Heaters In Door Leaf And Frame, Audio Alarm For Door Open Condition, Auto Lock And Release Mechanism In An Approve Manner. , Supplying And Erecting Prefabricated Door For Labortory Puf Insulated Room Complete Air Tight Of Size 1.2 M (W) X 2.1M (H) Made From 0.5 Mm Thick P.P. Sheet On Both Sides Having Sandwiched Puf Insulation Of 40 Kg/Mtr Cube Density, Thermal Conductivity Less Than 0.02 Wb/Mtr Cube And 50 Mm Thickness Complete Installing Alongwith The Door Frame Firmly To The Cold Room Panels Having Non Corrosive Handles, Locks, Hinges, Heaters In Door Leaf And Frame, Audio Alarm For Door Open Condition, Auto Lock And Release Mechanism In An Approve Manner. , Supplying And Erecting Prefabricated Door For Labortory Puf Insulated Room Complete Air Tight Of Size 0.900 M (W) X 2.1336 M (H) Made From 0.5 Mm Thick P.P. Sheet On Both Sides Having Sandwiched Puf Insulation Of 40 Kg/Mtr Cube Density, Thermal Conductivity Less Than 0.02 Wb/Mtr Cube And 50 Mm Thickness Complete Installing Alongwith The Door Frame Firmly To The Cold Room Panels Having Non Corrosive Handles, Locks, Hinges, Heaters In Door Leaf And Frame, Audio Alarm For Door Open Condition, Auto Lock And Release Mechanism In An Approve Manner. , Supplying And Erecting Prefabricated Door Forlabortory Puf Insulated Room Complete Air Tight Of Size 0.762 M (W) X 2.1336 M (H) Made From 0.5 Mm Thick P.P. Sheet On Both Sides Having Sandwiched Puf Insulation Of 40 Kg/Mtr Cube Density, Thermal Conductivity Less Than 0.02 Wb/Mtr Cube And 50 Mm Thickness Complete Installing Alongwith The Door Frame Firmly To The Cold Room Panels Having Non Corrosive Handles, Locks, Hinges, Heaters In Door Leaf And Frame, Audio Alarm For Door Open Condition, Auto Lock And Release Mechanism In An Approve Manner.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 02-03-2023 DATE EXTESTION Date 09-03-2023
2 13-02-2023 Corrigendum Other 01-03-2023

Key Value

Document Fees
INR 3000 /-
EMD
INR 50000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail