Tender For Rejuvenation Of Jjy Schemes Including Replacement Of Submersible Pump Sets / Panels / Cables And Other Allied Works Required For Functioning Of Tube Well In All Respect Including One Year Defect Liability Period Under Jen Section Kolu Pabuji, Jodhpur-Rajasthan

Government Departments has published Tender For Rejuvenation Of Jjy Schemes Including Replacement Of Submersible Pump Sets / Panels / Cables And Other Allied Works Required For Functioning Of Tube Well In All Respect Including One Year Defect Liability Period Under Jen Section Kolu Pabuji. Submission Date for this Tender is 09-02-2023. Coats and Jackets Tenders in Jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

36030103
Tender For Rejuvenation Of Jjy Schemes Including Replacement Of Submersible Pump Sets / Panels / Cables And Other Allied Works Required For Functioning Of Tube Well In All Respect Including One Year Defect Liability Period Under Jen Section Kolu Pabuji
Open Tender
Indian
Rajasthan
Jodhpur
09-02-2023

Tender Details

Rejuvenation of JJY Schemes including replacement of submersible pump sets / panels / cables and other allied works required for functioning of tube well in all respect including one year defect liability period under JEN Section Kolu Pabuji Rejuvenation Of Jjy Schemes Including Replacement Of Submersible Pump Sets / Panels / Cables And Other Allied Works Required For Functioning Of Tube Well In All Respect Including One Year Defect Liability Period Under Jen Section Kolu Pabuji , Phed Bsr / 2022-23 / Chapter-2 / 2.14 / Supply& Installationof Single Phase Isl Marked Submersible Motor Pump Set Of Three Star Or Better Rating Of Bee And As Per Is: 8034-2018 ( Pump ) And Is 9283-2013 ( Motor ) Or As Amended Up To Date Of Approved Make Of Following Duty Condition With Required Accessories Including Making Connection Suitable For Tube Well / Dcb. The Job Includesloweringof Motor Pump, Installationof Complete Fitting & Accessories, Jointing Of Electrical Cables Up To Switch Board, Testingofsubmersiblepumpsetandinterconnectionuptowatermains, Complete In All Respect. , 2.14.1 ) Up To 2.0 Kw , 2.14.2 ) Above 2.0 Kw , Phed Bsr / 2022-23 / Chapter-2 / 2.15 / Supply & Installation Of 3 Phase Isi Marked Submersible Motor Pump Set Of Five Star Rating By Bee And As Per Is: 8034-2018 ( Pump ) And Is 9283-2013 ( Motor ) Or As Amended Up To Date Of Approved Make Of Following Duty Condition With Required Accessories Including Making Connection Suitable For Tube Well / Dcb. The Job Includes Lowering Of Motor Pump, Installation Of Complete Fitting & Accessories, Jointing Of Electrical Cables Up To Switch Board, Testing Of Submersible Pump Set And Interconnection Up To Water Mains, Complete In All Respect. , 2.15.1 ) Up To 5.5 Kw ( 7.5 Hp ) & Head Up To 120 Mtr. , 2.15.2 ) Up To 5.5 Kw ( 7.5 Hp ) & Head Above 120 Mtr. , 2.15.3 ) 7.5 Kw ( 10 Hp ) & Head Up To 120 Mtr. , 2.15.4 ) 7.5 Kw ( 10 Hp ) & Head Above 120 Mtr , 2.15.5 ) 9.3 Kw ( 12.5 Hp ) & Head Up To 120 Mtr. , 2.15.6 ) 9.3 Kw ( 12.5 Hp ) & Head Above 120 Mtr. , 2.15.7 ) 11 Kw ( 15 Hp ) & Head Up To 120 Mtr. , 2.15.8 ) 11 Kw ( 15 Hp ) & Head Above 120 Mtr. , 2.15.9 ) 3 Kw ( 17.5 Hp ) & Head Up To 120 Mtr. , 2.15.10 ) 13 Kw ( 17.5 Hp ) & Head Above 120 Mtr. , 2.15.11 ) 15 Kw ( 20 Hp ) And Above, Head Up To 120 Mtr. , 2.15.12 ) 15 Kw ( 20 Hp ) And Above, Head Above 120 Mtr. , Phed Bsr / 2022-23 / Chapter-2 / 2.16 / Supply And Fixing Of Electric Feeder Panel ( Having Projected Canopy ) For Submersible Pump Set Single Phase Upto 5 Hp, Comprising Of Dol Starter, Mcb, Indicating Light, Ammeter, Volt Meter, Connection Plate, Condensers Of Approved Make And The Panel Enclosure Should Be Made Out From 18 Gauge M.S. Sheet With Powder Coating. Panel Size Height 600 Mm Width 500 Mm Depth 250 Mm With Stand ( Made Of Angle Iron Of Size 35X35x5mm ) Duly Bolted / Screwed With Enclosure Box Having 4 Legs, Each Leg’S Length 18 And Double Door Including In Built Locking System. The Legs Should Be Embedded In M-15 Cement Concrete Platform. The Size Of Cc Platform Should Be Equal Or Bigger Than The Base Size Of Panel Having Height Of At Least 200 Mm From Ground Level. The Operation Of Panel Should Be Suitable For On 240 Volt Ac Supply. , Phed Bsr / 2022-23 / Chapter-2 / 2.17 / Supply And Fixing Of Electric Control Feeder Panel Comprising Of Suitable Rating Mccb, Dol Starter, Overload Relay, Ampere Meter, Volt Meter, Phase Preventer, Phase Indicators, Lighting Arrangement Etc Complete Suitable For Three Phase Pump Set. The Panel Should Have Space For Energy Meter ( Supplied By Discom ) . All These Equipments Shall Be Housed By Panel Box Made Out From 18 Gauge M.S. Sheet With Powder Coating. Panel Should Be Of Minimum Size 900 X 600 X 300Mm With Stand ( Made Of Angle Iron Of Size 35X35x5mm ) Duly Bolted / Screwed With Enclosure Box Having 4 Legs, Each Leg’S Length 18 And Double Door Including In Built Locking System. The Legs Should Be Embedded In M-15 Cement Concrete Platform. The Size Of Cc Platform Should Be Equal Or Bigger Than The Base Size Of Panel Having Height Of At Least 200 Mm From Ground Level. The Panel Should Have Opening Of Suitable Size In Front Of Space For Energy Meter With Glass For Meter Reading. The Operation Of Panel Should Be Suitable For On 440 Volt Ac Supply. 2.17.1 ) Up To 5.00 Hp , Phed Bsr / 2022-23 / Chapter-2 / 2.18 / Supply And Fixing Of Electric Control Feeder Panel Comprising Of Suitable Rating Mccb , Fully Automatic Star-Delta Starter, Over Load Relay, Ampere Meter With Cts, Volt Meter, Phase Preventer, Suitable Starting Capacitors, Phase Indicators, Lightingarrangementetc. Completesuitablefor Threephasepumpset. The Panel Should Have Space For Energy Meter ( Supplied By Discom ) .All These Equipments Shall Be Housed By Panel Box Made Out From 18 Gauge M.S. Sheet With Powder Coating. Panel Should Be Ofminimum Size 900 X 600 X 450 Mm With Stand ( Made Of Angle Iron Of Size 35X35x5mm ) Duly Bolted / Screwed With Enclosure Box Having 4 Legs, Each Leg’S Length 18 And Double Door Including In Built Locking System.The Legs Should Be Embedded In M-15 Cement Concrete Plat Form. The Size Of Cc Platform Should Be Equal Or Bigger Than The Base Size Of Panel Having Height Of At Least 200 Mm From Ground Level. The Panel Should Have Opening Of Suitable Size In Front Of Space For Energy Meter With Glass For Meter Reading. The Operation Of Panel Should Be Suitable For On 440 Volt Ac Supply. , 2.18.1 ) Above5 Hpand Upto 10 Hp , 2.18.2 ) Above 10 Hp And Up To 15 Hp , 2.18.3 ) Above 15 Hp And Up To 20 Hp , 2.18.4 ) Above 20 Hp And Up To 30 Hp , Phed Bsr / 2022-23 / Chapter-2 / 2.19 / Supply & Fixing Of Isi Marked Three Core Pvc Flat Submersible Cable As Per Is 694:1990 Or Amended Up To Date And Conductor As Per Class 5 Of Is 8130:1980 Including Making Connection Etc. , 2.19.1 ) 3 Core 4.0 Sq.Mm , 2.19.2 ) 3 Core 6.0 Sq.Mm , 2.19.3 ) 3 Core 10.0 Sq.Mm , 2.19.4 ) 3 Core 16.0 Sq.Mm , Phed Bsr / 2022-23 / Chapter-2 / 2.20 / Supply & Fixing Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. , 2.20.1 ) 10.0 Sq.Mm, 4 Core , 2.20.2 ) 16.0 Sq.Mm, 4 Core , 2.20.3 ) 25.0 Sq.Mm, 3.5 Core , 2.20.4 ) 35.0 Sq.Mm, 3.5 Core , Phed Bsr / 2022-23 / Chapter-2 / 2.21 / Plate Earthing As Per Is:3043 With G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe Including All Accessories Like Nut, Bolts, Reducer , Nipple, Wire Meshed Funnel, And C.C. Finished Chamber Covered With Hinged Type With Locking Arrangement C.I. Cover, C.I. Frame Of Size 300Mm X 300Mm Complete With Alternate Layers Of Salt And Coke / Charcoal, Testing Of Earth Resistance As Required. , Phed Bsr / 2022-23 / Chapter-2 / 2.22 / Supply & Fixing M S Clamp Set Of 50X6 Mm Flat From Iron With Nuts And Bolts Etc For Holding The Riser Pipe Assembly Of Submersible Pump Set. , Phed Bsr / 2022-23 / Chapter-2 / 2.23 / Supply & Fixing Tube Well Cover Of Ms Sheet 8Mm Thick At Top & 5Mm Thick 100Mm Wide Shroud Around The Edge So As To Form A Cap On The Top End Of Casing Pipe With Gi Nipple 45Cm Long & Two Gi Flanges At Both Ends In 80Mm Sizes Passing Through A Hole In The Centre Of Ms Sheet. A 25 Mm Socket With End Plug Shall Also Be Welded Over Top Plate. A Gi Nipple Having Outside Thread Of Size 1 / 2 ( For Installation Pressure Gauge ) Shall Be Provided & Welded With 80Mm Gi Nipple Near Top Plate Nipple Shall Be Provided With End Plug. , 2.23.1 ) 125 Mm Dia , 2.23.2 ) 150 Mm Dia , 2.23.3 ) 200 Mm Dia , 2.23.4 ) 250 Mm Dia , Phed Bsr / 2022-23 / Chapter-2 / 2.24 / Providing & Lowering In Tube Well Isi Marked Gi Pipe “B Class As Per Is:1239 Or Amended Up To Date Threaded And Double Flanged ( Welded ) On Both Ends And Two Number 25X3mm Ms Flat Welded On Both Ends Between Pipe & Flange, Rubber Washer & Nut Bolts Etc. Complete In All Respect. , 2.24.1 ) 32 Mm Dia , 2.24.2 ) 50 Mm Dia , 2.24.3 ) 65 Mm Dia , 2.24.4 ) 80 Mm Dia , Phed Bsr / 2022-23 / Chapter-2 / 2.25 / Providing & Lowering In Tube Well Isi Marked Hdpe Pipe As Per Is 4984:1995 Or Amended Upto Date In Pe 80 Grade And Class Pn 10 Of Following Dia. Including Hdpe / Gi Fittings And Pvc Rope Confirming To Is 5175:1992 Or Amended Upto Date, Along With Clamping Of Submersible Cable Etc. Complete In All Respect. , 2.25.1 ) 40 Mm Dia , 2.25.2 ) 50 Mm Dia , 2.25.3 ) 63 Mm Dia , 2.25.4 ) 75 Mm Dia , 2.25.5 ) 90 Mm Dia , Phed Bsr / 2022-23 / Chapter-2 / 2.26 / Providing, Installing, Testing And Commissioning Of Double Flanged Bulk Flow Meter With Removable Mechanism, Of Class B Conforming To Iso 4064 / 1 Or Amended Upto Date Of Approved Make Including Cost Of All Material And Labour As Per Specifications With Gi Box ( Sheet 16 Swg ) Suitable With Locking Arrangement Of Following Dia. , 2.26.1 ) 50 Mm Dia , 2.26.2 ) 65 Mm Dia , 2.26.3 ) 80 Mm Dia , Phed Bsr / 2022-23 / Chapter-2 / 2.27 / Providing & Fixing Pump Safety Cage As Per Specifications Or As Directed By Engineer In Charge. , Phed Bsr / 2022-23 / Chapter-2 / 2.28 / Providing And Fixing Of Isi Marked Pvc Storage Tank Of Following Capacity As Per Is: 12701-1989 ( Of Approved Make ) With Cover, 25 Mm Dia. 1 Mtr Long Gi Overflow Pipe, 25 Cm Long 25 Mm Dia Washout Gi Pipe With Plug & Socket, Including P&F 32 Mm Dia Ball Cock ( Float Valve ) Is 1703 Marked With Rod And Pvc Ball Complete With Brass Weight 1000 Gm, Including P&F 15 Mm Dia Ci Quarter Turn Heavy Duty Bib Cocks Four Nos. Of Superior Quality And Approved Make, Including Interconnections Complete Job. , 2.28.1 ) 1000 Litres Capacity , 2.28.2 ) 2000 Litres Capacity , Phed Bsr / 2022-23 / Chapter-2 / 2.29 / Fabrication & Fixing M.S. Stand Of Specified Class Of Angle Iron Lshaped Of 50 Mm Size With Four Legs Grouted By 300*300*300 Mm Cc Block M-15 In The Ground And All Legs Tied Up With Each Other Through Same Size Of Angle Iron Along With Cross Bars To Support The Bottom Of 1000 Ltr. / 2000 Ltr. Pvc Tank Complete In All Respect. , Phed Bsr / 2022-23 / Chapter-2 / 2.30 / Providing & Fixing Of Double Flanged, Ci Body, Isi Marked Nrv Of Approved Make Of Following Sizes , 2.30.1 ) 65 Mm Dia , 2.30.2 ) 80 Mm Dia , Phed Bsr / 2022-23 / Chapter-2 / 2.31 / Proving And Fixing 32 Mm Dia Full Way Valve Or Wheel Valve As Per Is:778 Or Amended Up To Date Of Approved Make, On Pump Delivery Pipe. , Phed Bsr / 2022-23 / Chapter-2 / 2.32 / Supplying & Installing 100 Mm Diameter Sealed Diaphragm Bourdon Type Pressure Gauge Of Range 0 To 10 Kg. Including All Jointing Material As Per Specification With Safety Cover. , Phed Bsr / 2022-23 / 2.34 Providing And Lowering Of Isi Mark Pvc-U Casing And Screen Pipe As Per Is : 12818 : 2010 Or Amended Upto Date Having Pipe Thickness As Per Is Code Suitable For Tw And Dcb With Threading , Winding With Superior Quality Of Plastic Mesh & Rope In Three Layers With End Cap Complete As Per Technical Specification And Direction Of Engineer In Charge. , 2.34.1 ) Shallow Well Casing Pipe ( Cs ) Suitable For Depth Up To 80 Mtr. , 2.34.1.1 ) 150 Mm Nominal Dia ( Internal Dia ) . , 2.34.1.2 ) 200 Mm Nominal Dia ( Internal Dia ) . , 2.34.1.3 ) 250 Mm Nominal Dia ( Internal Dia ) . , 2.34.2 ) Medium Well Casing Pipe ( Cm ) Suitable For Depth Above 80 Mtr And Up To 250 Mtr. , 2.34.2.1 ) 100 Mm Nominal Dia ( Internal Dia ) . , 2.34.2.2 ) 125 Mm Nominal Dia ( Internal Dia ) . , 2.34.2.3 ) 150 Mm Nominal Dia ( Internal Dia ) . , 2.34.2.4 ) 200 Mm Nominal Dia ( Internal Dia ) . , 2.34.2.5 ) 250 Mm Nominal Dia ( Internal Dia ) . , Phed Bsr / 2022-23 / 1.4 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpeisi Marked Pipes As Per Is-4984: 1995 ( Amended Up To Date ) With Necessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe Byelectro Fusion Welding Method, Including All Taxes , Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) , Satisfactory Hydraulic Testing, Disinfection, Commissioning Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earth Work ) . Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. Supply May Be In Coil Or Straight Length In 6 M / 12 M. , Hdpe Pe-80Pn-6 , 75 Mm Dia , 90 Mm Dia , Phed Bsr / 2022-23 / Chapter-6 / 6.1 / Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci D / F Sluice Valves Straight And Pocket Less Body Passage Of Approved Make Of Following Pressure Rating & Dia Complete, Confirfing To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200 Stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss , Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , Epoxy ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel Insersion Rubber Of Black Epdm 6Mm Thick . Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. , 6.1.1 - Manually Operated Ci Sluice Valve Of Class Pn-1.0 , 6.1.1.1 -80 Mm Hw , 6.1.1.2 - 100 Mm Hw

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-
Disclaimer :