Tender For Supply Installation Testing Commissioning Of 40 Hp ( 02Nos. ) Electric Pump Sets With All Allied Equipment And Accessories At Newly Buildup Pump House In Seelampur Under Snz In Mcd. - Supply Installation Testing And Commissioning Of 40 Hp Electric Pump Set Horizontal End Suction Pumps With Non-Clog Impeller Having Delivery Upwards To Handle Storm / Sewage Water. The Pumps Should Be In Standard Construction Having Ss Impeller , Stainless Steel Shaft And Casing Design Of Pump Should Be Such That The Pump Losses Are Minimum, Economical In Cost And Easy To Maintain. All Rotating Parts Shall Be Statically And Dynamically Balanced To Ensure Vibration Less Operations After Erection. The Pump Should Be Coupled With Suitable Horizontal Tefc Electric Squirrel Cage Induction Motor Mounted On Common M.S Base Frame / Plate Through A Pair Of Flexible Coupling M.S Guards Etc. The 40 Hp Motor Hall Be Horizontal In Design, Foot Mounted Construction For Operation On 3 Phase, 415 Volts 10% 50 C / S , A.C Supply Having Continuous Rating And F Class Of Insulation Discharge =440 M³ / Hour Head =15 Mtr Rpm = 1450 Hp Of Motor =40Hp 2 Supply And Fixing Of B-Series Anti Vibrating Spring Foot Mounting Pad For 40 H P Pump Set. 3 Supply Anf Fixing Of 300 Mm Dia For Header Line ( 9.5 Mm Thick ) M.S Black Pipe Heavy Duty Conforming To Is:1239 Part-1 ( 1990 ) 4 Supply And Fixing Of 300 Mm Dia ( 25 Mm Thickness ) M.S Flange With Required Nut Bolts And Packing Sheet Etc Complete As Required. 5 Supply And Fixing Of 300 Mm Dia ( 8 Mm Thick ) , Length 0.75 Mtr M.S Bend . 6 Supply And Fixingof 300 Mm Dia ( 25 Mm Thickness ) M.S Blankflange 7 Supply And Fixing Of Of 150 Mm Dia M.S Black Pipe Heavy Duty ( C-Class ) Conforming To Is:1239 Part-1 ( 1990 ) 8 Supply And Fixing Of 150 Mm Dia Non Rising Spindle Sluice Valve Of Ci Body With Wedge, Bronze Ring Confirming To Is 14846 & Ss Is: 6603 ( Isi Marked ) , Pn 1.6 Ci 9 Supply And Fixing Of150 Mm Dia Swing Type Non Return Valve Of Ci Body With Door, Bronze To Rubber Rings Confirming Tois5312 10 Supply And Fixing Of 150 Mm Dia ( 12 Mm Thickness ) M.S Flange With Required Nut Bolts And Packing Sheet Etc Complete As Required. 11 Supply And Fixing Of 150 Mm Dia ( 8 Mm Thick ) , Length 0.5 Mtr M.S Bend . 12 Supplyof Corrugated & Chequered Rubber Mat Having Thickness 25 Mm And Size In 1M X 2M. 13 Sitc Of Pillar Box Size900mmx 450 Mmx 250 Mm Suitable For Mounting Incomer Of 250 A Mccb / Main Switch 4 Pole And Energy Meter 3 Phase Complete With Eleethoypic Grade Aluminium Bus Bar Of Size 25Mmx19mm Mounted On Galvanized Ms Body Power Coated Pilferage Proof Smc Door Duly Welded With Ss With Rain Com Size 40 Mmx 40 Mmx 5 Mm X600mm Height In Cutting 300 Mm Height Below Grand And Covered With Shade Proof Smc Sheet Of 3 Mm As Required. 14 Sitc Of 50 Hp Fully Automatic Star Delta Motor Starter In Sheet Steel Enclosure Type Mn With Spp Feature I / C Connection Etc. Complete As Required. 15 Sitc Of 4 Pole 320 Amp Off Load Side Handle Change Over Switch Conforming To Is: 13947 ( Part I & Iii ) In Sheet Steel Enclosure I / C Connection Etc. Complete As Required. 16 Supplying, Installing, Testing And Commissioning Of Following Capacity Tpn Tap Off Box Made Of 1.6Mm Thick Sheet Steel Enclosure Duly Painted With Powder Coating On Existing Rising Mains Complete With Tpn Disconnector Fsu And Hrc Fuses, Connections, Earthing Etc. As Required ( A ) 200 Amp 17 315Amp 18 Supply Of 70 Sq Mm X3.5 Core Xple / Pvc Insulated & Pvc Sheathed ( Heavy Duty ) Armoured Alluminium Conductor Power Cable For Working Voltage 1.1 Kv Confirming Is7098 / 1554 ( Part-I ) As Reqd 19 Supply Of 95 Sq Mm X3.5 Core Xple / Pvc Insulated & Pvc Sheathed ( Heavy Duty ) Armoured Aluminium Conductor Power Cable For Working Voltage 1.1 Kv Confirming Is7098 / 1554 ( Part-I ) As Reqd 20 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required 100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 21 225 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 22 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays Tee With Perforation Not More Than 17.5%, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 23 225 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 24 Supplying And Making End Termination With Brass Compression Glandandaluminiumlugsforfollowing Sizeofpvcinsulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required3.5X70 Sqmm ( 38Mm ) 25 3.5 X 95 Sq. Mm ( 45Mm ) 26 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nomical Size ) In Foundation Of Pump Set Including Form Work Etc As Reqd. 27 Earthling With G.I Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc ( W / O Charcoal / Coke And Salt ) As Reqd. 28 Providing And Fixing 25 Mm X5 Mm G I Stripstrip At 0.50 Meter Below Ground As Strip Earth Electrode Including Connection / Termination With Nut Bolt Spring Washer Etc As Reqd. ( Jointingshall Be Done By Overlaping And With 2 Sets Of Brass Nut Bolt And Spring Washer Spaced At 50 Mm ) 29 Sitc Of The New Vacuum Pump Of 5 Hpmodelwith Indus 3 Phase Motor Or Equivalent Vacuum Pump Of Size 40X40 Mm With Standard Fitting As Per Manufacturer Size 40 Mm G I Pipe With All Fittings Nipple Elbo Union Gate Valve 40Mm Size For Each Pump For Chargingcapable Of Priming Of Main Pump Set And Evacuation Of Air From Suction Pipe And Chamber. 30 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size Ms Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group C 31 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 32 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 33 Supplying And Fixing Metal Box Of 150 Mm X 75 Mm X60 Mm Deep ( Nominal Size ) On Surface Or In Recesswith Suitable Size Of Phenolic Laminated Sheet Coverin Front Including Providing And Fixing 3 Pin 5 / 6 Asocket Outlet And 5 / 6 A Piano Type Switch, Connections, Painting Etc. As Required. 34 Supplying And Fixing Metal Box Of 180 Mm X 100 Mm X 60 Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 6 Pin 5 / 6 A & 15 / 16 A Socket Outlet And 15 / 16 A Piano Type Switch, Connections, Painting Etc. As Required 35 Supplying And Fixing Following Way, Single Pole Andneutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Busbar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthingetc. As Required. ( But Without Mcb / Rccb / Isolator ) 8 Way, Double Door 36 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitablefor Inductive Load Of Following Poles In The Existingmcb Db Complete With Connesingle Pole 37 Double Pole 38 Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable For Working Voltage Upto 1.1Kv Confirming To Is-7098 Of Following Sizes: 2 X 10 Sq.Mm 39 Sitc Of 100 W Led Flood Light Luminiare Fitted With Lens, Madeof Pressure Die Cast Aluminum Housing & Toughened Glass Cover Complete With The Following Specification As Reqd. ( A ) Total System Wattage = 90Watt+ / -5% ( D ) Luminaire Efficacy>=100 Lm / W ( E ) Power Factor>=.95 ( F ) Protection Class-Ip-66 40 P / Fhot Press Sheet Mouldedcompound ( Smc ) Fire Retardant ( Temp. Resistance Up To 200 C ) , Ip 55 Weather Proof Polebox Of Innerdimension 2000X160x98mm ( Ns ) Complete With Suitable Arrangment For Fixing Of1nosof 6 To 32 Amp Single Pole Mcb & 63 Amp. Doublepole Isolator ( Mcb / Isolator Excluded ) Withneutral Link Duly Shorting On Din Channel With2 Nos Of Ms Clamps With Ss Back Plateofsuitable Size With Danger Monogram Property Printed On The Coveretc Asreqd. ( Without Mcb ) 41 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan Withbrush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos.Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc.Complete As Required. 42 Sitc Of Surface Mounting Led Luminaire Suitable For 1X20 Watt Led Rating Box Type Complete With Extruded Aluminium Batten Prewired With High Efficient Leds With The Following: A ) Total System Wattage 20 ±5% Wattb ) Luminaries Effucacy = 100 Lumens / Watt C ) Power Factor = 0.95 43 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And For Making Ms Mesh At Sumpwell And Bar Screen 44 Supply Of Heat Resistant Flameretardant Pvc Insulated Industrial Grade Copper Conductor ( Unsheathed ) Flexible Cables Of 35 Sqmm Single Core 45 Supply Of250 Mm ( 10 Inch ) Sweep 1250 Rpm Exhaust Fan Fresh Air Type Complete With Shutters Blades Etc As Reqd 46 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep 47 Laying And Fixing Of One Number Pvc Insulated And Pvcsheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Sizeon Wall Surface As Required. Hume / Metal Pipe 48 Above 35 Sq. Mm And Upto 95 Sq. Mm