Tender For Provision Of Religious Institute Hall ( Sarv Dharmstal ) Under Ge ( N ) Bathinda At Bathinda Mil Station - Lump Sum Price Worked Out By The Contractor For “Building / Structure Work” As Listed In Schedule ‘A’ Part - Iabove / Below The Lump Sum Price Inserted By The Mes Against This Schedule Under Col 6. 3 Schedule A Part-Ii ( Earth Work ) 4 Lump Sum Price Worked Out By The Contractor For “Earth Works” As Listed In Schedule ‘A’ Part -Iiabove / Below The Lump Sum Price Inserted By The Mes Against This Schedule Under Col 6. 5 Schedule A Part-Iii ( External Water Supply ) 6 Lump Sum Price Worked Out By The Contractor For “External Water Supply Works” As Listed In Schedule ‘A’ Part -Iiiabove / Below The Lump Sum Price Inserted By The Mes Against This Schedule Under Col 6. 7 Schedule A Part-Iv ( Internal Electric Supply ) 8 Lump Sum Price Worked Out By The Contractor For “Internal Electric Supply Works” As Listed In Schedule ‘A’ Part -Ivabove / Below The Lump Sum Price Inserted By The Mes Against This Schedule Under Col 6. 9 Schedule A Part-V ( External Electric Supply ) 10 Lump Sum Price Worked Out By The Contractor For “External Electric Supply Works” As Listed In Schedule ‘A’ Part -V ( Section-A ) Above / Below The Lump Sum Price Inserted By The Mes Against This Schedule Under Col 6. 11 Schedule A Part-Vi ( Misc Works ) 12 M & L For Construction Of Valve Pit Type B Of Size 60Cm X 60 Cm X 60 Cm ( Internal Dimension ) Of Brick Masonry Laid With Cement Mortar ( 1:4 ) Including Cover Of Ms Sheet 3.15 Mm Thick And Angle Iron Frame 50Mmx 50Mmx 6Mm With Hinges, Handle And Locking Arrangement Including Painting With Two Coat Of Synthetic Enamelled Paint Over A Coat Of Red Oxide Primer And Grouting To Pcc 1:2:4 Type B-1, Using 20Mm Graded Crushed Stone Aggregates, Rendering 15 Mm Thick In Cement Mortar 1:3 And Three Coats Of White Wash On Internal Surfaces And External Exposed Surfaces, Foundation Concrete 1:3:6 Type C-2 Using 40 Mm Graded Crushed Stone Aggregates Including Necessary Earthwork, Returning Filling, Removal Complete All As Specified And Shown On Drawings.Note:- Applicable Drawing For Valve Pit Is Drawing No. Btd-811 Sheet 1 / 2 To 2 / 2 13 Supply, Fabricating, Installation, Testing, Commissioning And Electrically Connecting Lt Feeder Pillar Box Cubical Type Of Size 60 Cm X 40 Cm X30 Cm , 415 Volts, Factory Made, Machine Pressed, Dust And Vermin Proof, Out Door Type , Made With Crca Sheet 3.15 Mm Thick, Feeder Pillar Box Shall Be Powder Coated With 7 Tank Process For Treatment Of Degreasing, Pickling & Two Coats Primer, Before Being Given The Stove Epoxy Finish.Frontopeningwith Single Door With Provn Of Rubber Beading And Locking System, Including 200 Amp Aluminium Bus Bar Set Of 4 With Provn Of Hole On Bus Bar For Fixing Of Cable Mounted On Pvc / Epoxy Insulators, Including Mccb 100 Amp, 4 Pole, 415 Volts Rating With Breaking Capacity 16 Ka, Adjustable Setting = 80-100% And Mounted On Angle Iron Legs Frame Made With Angle Iron Size 25 Mm X 25Mm X 5 Mm And Legs Duly Spray Painted Internally And Externally With Tow Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer , Legs Grouted In Pcc ( 1:2:4 ) Type B-1 ( Using 20Mm Graded Crushed Stone Aggregate ) Including Necessary Earth Work Complete, Including All Provn Of Opening For Incoming / Outgoing Cables And Testing Complete All As Directed By Engr-In-Charge.Note:- The Cost Of 200 Amp Aluminium Bus Bar Set Of 4 Pvc / Epoxy Insulator And Mccb 100 Amp , 4 Pole , 415 Volts Rating With Breaking Capacity 16 Ka Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 14 M & L For Making The Hole Under Road And Hard Standing Not Less Than 1 Metre Depth And Suitable For Laying And Inserting Pipe Upto 80 Mm Dia Any Length By Mechanical Drill System Or Auger System And Making The Surface Good As Per Existing Surface Complete All As Specifed And Directed. Note: Gi Tubing Shall Be Measured And Paid Separately. 15 M & L For Earthing Complete With Galvanized Iron Or Steelearth Plateelectrode Of Size 60 Cm X 60Cm X 6.0Mm Thick Buried Directly In Ground, Vertically To A Depth Not Less Than 2.25 Mtr Below Normal Ground Level With Top Edge Of Earth Plate At Depth Of Not Less Than 1.5 Mtr Below Normal Ground Level Surrounded From All Sides With Alternate Layers Of Charcoal And Common Salt And Connected To Galvanized Earth Lead Wire 4.0 Mm Dia By Means Of Gi Bolts, Nuts Washers & Check Nuts And Washers Of Gi ( Including Making Of Test Point Withgalvanized Earth Lead Wire 4.0 Mm Dia Including Gi Protection Pipe 20 Mm Bore Light Grade For Protection Of Gi Wire To The Extent Of 7.5 Mtr All As Directed, Gi Pipe Light Grade 20 Mm Bore For Watering Including Providing Funnel And Wire Mesh, Gi Frame With Suitably Reinforced Rcc Pit Cover, Pcc Chamber Pit With Pcc ( 1:3:6 ) Type C2 Using 40 Mm Graded Stone Aggregates Complete Including Excavation And Earth Work In Any Type Of Strata , All As Specified And Shown In Electrical Plate No 3 Of Ssr-2009 Part - I, Pcc Pit Shall Be Provided At Least 50 Cm Away From The Earth Pit And Not Just On Earth Pit Including Testing On Completion Complete All As Specified And Directed. 16 M & L For Earthing Complete With Galvanized Iron Or Steelearth Plateelectrode Of Size 60 Cm X 60Cm X 6.0Mm Thick Buried Directly In Ground, Vertically To A Depth Not Less Than 2.25 Mtr Below Normal Ground Level With Top Edge Of Earth Plate At Depth Of Not Less Than 1.5 Mtr Below Normal Ground Level Surrounded From All Sides With Alternate Layers Of Charcoal And Common Salt And Connected To Gi Earth Strip 32 X 6 Mm Thick By Means Of Gi Bolts, Nuts Washers & Check Nuts And Soldering The Strip, Electrode Connected To Panel Board Or On Poles Or On Transformer ( Including Making Of Test Point With Gi Strip Of Size 32 X 6 Mm ) Including Gi Protection Pipe 40 Mm Bore Light Grade Dia For Protection Of Strip Upto The Extent Of 7.5 Mtr All As Directed, Gi Pipe Light Grade 20 Mm Bore For Watering Including Providing Funnel And Wire Mesh, Gi Frame With Suitably Reinforced Rcc Pit Cover, Pcc Chamber Pit With Pcc ( 1:3:6 ) Type C2 Using 40 Mm Graded Stone Aggregates Complete Including Excavation And Earth Work In Any Type Of Strata , All As Specified And Shown In Electrical Plate No 3 Of Ssr-2009 Part - I, Pcc Pit Shall Be Provided At Least 50 Cm Away From The Earth Pit And Not Just On Earth Pit Including Testing On Completion Complete All As Specified And Directed. Note:- The Rate Quoted By The Contractor Shall Be Deemed To Be Included Of Earth Strip 32X6mm And Pit Protection Pipe 40Mm Dia Light Grade Up To 7.5 Mtr Distance. Earth Strip Beyond 7.5 Mtr Will Be Measured And Paid Separately Under Relevant Items