| 1 | Excavation of soft/loose soils in trenches n.exc 1.50mwide and n.exc 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, drain, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth including any type old pipe and getting out complete all as specified and directed. |
| 2 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. |
| 3 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including rubbish off the premises complete all as specified and directed. |
| 4 | M&L PCC (1:4:8) type D-2(using 40mm graded stone agg.) as in foundation/sub base of open drain, saucer drain, culvert, interlocking and chequreded tilecomplete all as specified and directed. |
| 5 | M&L for brick workwith sub class \"B\" straight or curved on plan exc 6m mean radius and built in CM 1:4 complete all as specified and directed. |
| 6 | All as per srl item No 5 above but except bricks. |
| 7 | Returning, filling in including spreading leveling, watering and wellramming in layers n.exc 25 cm of soil all as specified & directed. |
| 8 | Removing surplus soil to a distanceexceedingexc. 1.50 km but n exc. 5 km and depositing where directed |
| 9 | M&L 15mm thick rendering on fair faces of brick work surface in cement mortar (1:4) with using Water Proofing Liquid’ as per manufacturer\"s instructions.(Note : Rate of WPC included in quoted rate and nothing extra payble on this acount).complete all as specified and directed. |
| 10 | M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping/bed block including weathering slightly rounded or chamfered angles and throating as directed and including necessary form work required complete all as specified and directed. |
| 11 | M&L for cement concrete type B-2, 1:2:4 in surface channels and drains all as specified and directed |
| 12 | Extra for forming fair finished drain or channel upto 65 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etccomplete all as specified and directed. |
| 13 | Cleaning ofdrain having inner width upto 0.6m and depth upto 1.2 metre by removingmud, garbage, debries, sludge, vegitation etc having average depth 0.45 m through manually or machnically complete all as specified and directed. |
| 14 | S&F 110mm bore UPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 15 | M&L 75mm thickPCC (1:3:6) type C1 (using 20mm stone aggregate) as in floors/pavings /plinth protection etc, finished even and fair with using extra cement including joint filling with mastic etc complete all as specified and directed. |
| 16 | M&L for 100 mm thickPCC (1:4:8) type D2 (using 40mm stone aggregate) as in sub base of floor complete all as specified and directed. |
| 17 | M&L for 50mm thick sand cushion/Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 18 | M&L 60mm thick Coloured cement concrete interlockingpaver blocks hydraulically pressed of compressive strength not less than M-35 grade complete all as specified and directed including dismantling old paver tiles |
| 19 | M&L for Coloured Machine pressed cement concrete chequered tiles 30cm X 30cm X 25mm thick machine pressed; set jointed and pointed in neat cement slurry in floors and cut and pointed with white cement and pigment over 20 mm thick screed bed in cement mortor (1:6) complete all as specified and directed including dismantling old tiles |
| 20 | M&L for 15mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on wall, finish the surface even and smooth without using extra cement as whole or in patch etc including taking down cement plaster on brick walls etc including raking out joints hacking for key scrubbing down with water etc all as directed, rubbish of the premises complete all as specified and directed. |
| 21 | M&L for15mm thick rendering on concrete surface/brick surface in cement mortar (1:4) surface finished even and fair mixed with liquid WPCas per manufacturer\"s instructions including taking down cement plaster on brick walls etc including raking out joints hacking for key scrubbing down with water etc all as directed, rubbish of the premises complete all as specified and directed.(Note : Rate of WPC included in quoted rate and nothing extra payble on this acount). |
| 22 | M&L preparation of surfacesand applying two coats of cement base paint over a coat of primer on external surfaces of walls complete all as specified and directed. |
| 23 | Demolition of reinforced cement concreteas manhole cover and similar workn.exc 15cm thick and removal of rubbish beyond MOD land complete all as specified and directed. |
| 24 | M&L RCC cement concrete(1:2:4) type B-1 (using 20mm graded stone aggregate) as in manhole covers slab and similar work set in cement mortar 1:6 complete all as specified and directed. |
| 25 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 26 | M&L preparation of old steel and iron surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 27 | M&L preparation of surfaces by complete removal of existing treatment & applying two coats of cement base paint on walls over a coat of primerall as specified & directed. |
| 28 | M&L 16-18mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. and including demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar and removal of rubbish beyond MOD land complete all as specified and directed. |
| 29 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion or fixed in PCC and providing now one complete making good disturbed ground complete all as specified and directed. (Note:- Post shall be measured and paid separately) |
| 30 | S&F MS work as in Y Shape angle as in post and struts & similar work including cutting top to shapes as directed, drilling holes notching of wires etc conforming to Fe410-0 or FE 310-0 complete all as specified and directed including dismantling of mild steel work of any description. |
| 31 | S&F in repairs Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed. |
| 32 | S&F laying of punched type cencertina coil ( PPTC) 610 mm dia, 50 turns and made up of 2.60 mm HTGS spring core wire having tensile strength of 1600N sqm mand punched tape shall be of hot dipped galvanised min 200 micron and having barbs of 24 mm width @ 24 mm width @ 35 mm centre to centre complete all as specified and directed. |
| 33 | M&L for framed work such as grills, grating etc with ends of bars shouldered or riveted or forged into spikes framed guard bars and similar work confirming to Fe - 410-0 or Fe - 310 - 0 including dismantling of mild steel work of any description complete all as specified and directed. |
| 34 | M&L for preparation of newsteel surfaces, painting two coats of synthetic enamel paints over a coat of red oxide primerexc 10mm width or girth complete all as specified and directed. |
| 35 | M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and including dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed. |