| 1 | Taking down existing unserviceable ceiling fan of any sweep and size from fan hook from different location, disconnecting and sealing electrical line for annual maintenance/ servicing; dismantling various parts of ceiling fan for repair/ replacement, servicing etc., cleaning thoroughly, greasing of ball bearings, oiling of bush bearings, replacing split pin and rubber real, repair/replacement of minor worn out parts, including re-assembling the fan after servicing and replacement of existing major worn out spare parts under ser Item No. 2 to 7 in case required,servicing and hanging in its original location complete with and including making electrical connection from ceiling rose to fan and testing complete all as directed.NOTE: Taking out existing defective major spare parts and fixing new spare parts on fans will be measured and paid separatelyunder ser item No. 2 to 7 here-in-after. However the rate quoted shall be deemed to be included for all other minor parts which are essential for smooth functioning of fani.e. greasing, oiling, split pin, rubber real, PVC canopy, rubber bush, hanging clamp etc. included in the quoted rates. |
| 2 | S&F in replacement of stator shaft suitable for fixing top and bottom bearings of ceiling fan of any size |
| 3 | S&F in replacement of ceiling fan condenser 2.5 Mfd 50Hz, 240 V |
| 4 | S&F in replacement of ceiling fan condenser 4.0 Mfd 50Hz, 240 V |
| 5 | S&F in replacement of ball bearings suitable for ceiling fan 1200 mm sweep. |
| 6 | S&F in replacement of ball bearings suitable for ceiling fan 1400 mm sweep. |
| 7 | S&F in replacement of Gun metal self-lubricated bush suitable for ceiling fan of any size |
| 8 | Taking down existing unserviceable exhaust fan of any sweep and size from fan hook from different location, disconnecting and sealing electrical line for annual maintenance/ servicing; dismantling various parts of exhaust fan for repair/ replacement, servicing etc., cleaning thoroughly, greasing of ball bearings, oiling of bush bearings, replacing split pin and rubber real, repair/replacement of minor worn out parts, including re-assembling the exhaust fan after servicing and replacement of existing major worn out spare parts under ser Item No. 9 to 12 in case required,servicing and fixing in its original location complete with and including making electrical connection from ceiling rose to fan and testing complete all as directed.NOTE: Taking out existing defective major spare parts and fixing new spare parts on fans will be measured and paid separatelyunder ser item No. 9 to 12 here-in-after. However the rate quoted shall be deemed to be included for all other minor parts which are essential for smooth functioning of fani.e. greasing, oiling, etc. included in the quoted rates. |
| 9 | S&F in replacement of ball bearings suitable for exhaust fan 230/300mm dia sweep |
| 10 | S&F in replacement of ball bearings suitable for 380/450mm dia sweep |
| 11 | S&F in replacement of Fan Condenser square type 1.5/1.85 Mfd 50Hz, 240 V |
| 12 | S&F in replacement of Gun metal self-lubricated bush suitable for exhaust fan of any size |
| 13 | Taking down existing unserviceable geysers of any capacity and make from different locations as directed, disconnecting and sealing electrical and water connections for annual maintenance/servicing, removing existing grouted blunt threaded bolts, nuts & washers, dismantling the same for servicing including taking out sludge from inner tank and washing/cleaning with diluted Hydrochloric acid, repair/replacement of minor worn out parts,reassembling including after replacement of existing major worn out spare parts under ser Item No. 14 to 23 in case required, and refixing the same in its original location, connecting all electrical connections and water connections including making good to the disturbed surface and testing complete all as directed.NOTE: Taking out existing defective major spare parts and fixing new spare parts on geysers will be measured and paid separately under ser item No. 14 to 23 here-in-after. However the rate quoted shall be deemed to be included for all other minor parts which are essential for smooth functioning of geysers i.e. indicator lamp, plug top etc. |
| 14 | S&F in replacement heating element threaded type/triangle type/round type with rubber washer (ISI marked), 2.0KW, suitable for 50 ltr Geyser capacity including necessary nuts, bolts and washers. |
| 15 | S&F in replacement heating element threaded type/triangle type/round type with rubber washer (ISI marked), 1.5KW, suitable for 25 ltr Geyser capacity including necessary nuts, bolts and washers. |
| 16 | S&F in replacement Thermostat stem type, 12” long, suitable to adjust up to 70ºC for Geyser |
| 17 | S&F in replacement Thermostat stem type, 9” long, suitable to adjust up to 70ºC for Geyser |
| 18 | S&F in replacement thermal cut out stem type ISI marked suitable for any capacity geyser |
| 19 | S&F in replacement fusible plug made of brass having lead alloy fuse suitable for any capacity geyser. |
| 20 | S&F in replacement pressure release valve chromium plated screws suitable for 15mm dia of any capacity geyser |
| 21 | S&F in replacement non return valve brass size 15mm dia suitable for 15mm dia GI pipe |
| 22 | S&F in replacement PVC steel braided inlet/outlet connection pipe 15mm dia, 450mm long with two numbers brass union, nipple, check/end nuts with washers, etc, for hot water and cold water connections |
| 23 | M&L for repairs of leakage to geysers of 25 ltrs capacity of any make by spot copper brazing and pressure testing for leakage complete all as directed. |
| 24 | Taking out carefully burnt starter assembly & burnt copper winding as directed, cleaning stator slots and providing new paper insulation within slots, rewinding of stator assembly with new supper enamelled copper winding wire of appropriate gauge suitable for 1400mm (56\") dia sweep ceiling fan complete including varnishing, backing, re-assembling the ceiling fan motor after re-winding and hanging including making electrical connection from ceiling rose to fan and testing at all speed complete all as directed |
| 25 | All as per ser item No. 24 here-in-before but ceiling fan of size 1200mm (48\") |
| 26 | All as per ser item No. 24 here-in-before but exhaust fan of size 450/350mm (18\"/14\") |
| 27 | All as per ser item No. 24 here-in-before but exhaust fan of size 230/300mm (10\"/12\") |
| 28 | M&L for annual painting of ceiling fan of any size; scraping out of old existing paint with emery paper and painting with one coat of approved quality synthetic enamel paint in existing colour by spraying including filling cavities, re-assembling the ceiling fan after painting and hanging in its original location including writing MES No. and testing complete all as directed. |
| 29 | All as per ser item No. 28 here-in-before but for exhaust fan of any size |
| 30 | All as per ser item No. 28 here-in-before but for geyser of any size |
| 31 | Dismantling incoming and outgoing pipes from solar water storage tank and solar panel and all electrical components, cleaning completely water tank, solar panel and all the pipes properly and re-connecting and re-assembling the solar water heating system in its original location complete with and including provn of new cable of existing size and testing complete all as directed.NOTE: Minor parts, if any, other than those specified in the schedule and required for smooth functioning of solar geyser shall be deemed to be included in the quoted |
| 32 | M&L for repair of solar panel including replacement of worn out/ damage accessories as per existing specification and making all electrical and water connections complete all as directed. |
| 33 | Supply, laying, connecting and testing UPVC high pressure pasted pipe all as per ASTM - 1785 sch 80 as per IS-554, with working pressure upto 10 Kg/cm2 of size 15mm dia including fixed complete to walls, ceiligs or in floors etc., with all fittings including taking down existing unserviceable all as directed. |
| 34 | S&F in repair gun metal, globe or gate valve with ISI mark IS-778 Class-I of size 15mm bore dia wheel head screwed both ends suitable for fitting with UPVC pipe complete all as directed |
| 35 | S&F in repair Ball brass valves, high pressure, with polythene float and fly nut, with epoxy coated aluminium rod complete screwed of size 15mm bore dia for PVC over head tank inside UPVC/PPR pipe and fixed complete all as directed |
| 36 | S&F in repair rotational moulded polyethylene water storage tanks triple layer of capacity 250 litres, 100% UV stabilised, rust proof, Algae formation protection, free maintainance, asthetic design, Cylindrical vertical with closed top, hoisted and fixed in position and connecting up complete all as specified in SSR Part - INOTE: PVC water tank should be triple layer (i.e., White layer-maintains water temperature; Black layer-protects from UV radiation; Blue layer-for better visibility inside tank) |