| 1 | Taking down carefullyCopper/ aluminium point wiringlight, Fan, socket orpower completeincluding fixture & fitting such as switches, sockets or power socket complete fitting bracket holder, boards, and making good disturbed surfaces of wall and ceiling etc complete all as specified and directed. |
| 2 | Taking down carefully unserviceable sub main wiring/PVC cable including conduit/casing patti etc complete all as specified and directed. |
| 3 | Taking down unserviceable DBs any type / size carefully disconnecting and making good disturbed surfaces complete all as all as specified and directed. |
| 4 | Taking down unserviceable MCB SP/SPN/Isolator/MCCB/RCCBs ofany rating & size complete all as specified and directed. |
| 5 | M &L for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated 1100V, FRLS grade with multistranded copper conductor ISI marked drawn through with and including PVC casing & capping fixed on surface wall/ceiling and including modular cover plates and modular flush boxes for mounting of switches, sockets regulators etc including 1.5 Sqmm PVC insulted unsheathed cable multistranded with copper conductor and connecting to earth dolly for light, fan, plug and bell and making goodthe distributed surfacess completely matched and finished with existing surfacess complete all as specified and directed.(a)One light point controlled by one 5 Amps one way switch. |
| 6 | (b)One light point controlled by two way switch |
| 7 | (c)One ceiling Fan, Exhaust Fan point controlled by one 5 Amps switch. |
| 8 | (d ) One bell/buzzer point controlled by one bell push button on independent board. |
| 9 | (e)One 3 Pin 6 Amps socket point on the independent board. |
| 10 | (f)One 3 pin 6 Amp socket point on the same board with other switch. |
| 11 | All as perabove item No-5.00 but with 2.5 Sqmm cable for 15 Amp switch socket out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor as earthing continuity conductor complete all as specified and directed. |
| 12 | Cutting chases ,pinning in making good to facing where required and pointing in cement motar 1:3 to end or edges of landings,steps, cills,sunshades ,shelves, lintels, etc.and cutting hases for concealed water tubing or concealed water tubing or concealed conduit wiring,etc.and making good cutting exceeding 10cm girth complete all as specified and directed. |
| 13 | M &L for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FRLS grade with multistranded copper conductor ISI marked drawn through with and including PVC Conduit recess/surface fixed modular cover plates and modular flush boxes for mounting of switches, sockets regulators etc including 1.5 Sqmm PVC insulted unsheathed cable multistranded with copper conductor and connecting to earth dolly for light, fan, plug and bell and making goodthe distributed surfacess completely matched and finished with existing surfacess complete all as specified and directed.(a)One light point controlled by one 6 Amps one way switch |
| 14 | (b)One ceiling Fan, Exhaust Fan point controlled by one 6 Amps switch. |
| 15 | (c ) One bell/buzzer point controlled by one bell push button on independent. |
| 16 | (d)One light point controlled by 2 Nos,6 amps Two way switch. |
| 17 | (e)One 3 pin socket out let 6 Amp point on independent board |
| 18 | (f)One 3 Pin socket out let 6 Amp point on the same board with other switch. |
| 19 | All as per above item No-8.00but with 4 Sqmm cable for 16 Amps switch sockets out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor as earthing continuity conductor complete all as specified and directed. |
| 20 | Supply and fixing switch piano flushtype , single pole one way 5 Amps all asspecified and directed. |
| 21 | Supply and fixing switch piano flush type , single pole two way 5 Amps all as specified and directed. |
| 22 | Supply and fixing Bell push flush type SP 5 Amps all as specified and directed. . |
| 23 | Supply and fixing switch socketcombination out let 5 pin 6 Amps flush type all as specified and directed. |
| 24 | Supply and fixing switch socket combination 2 in 1, 5 and 16 Amps flush type all as specified and directed. |
| 25 | Supply and fixing modularswitch 6 Amps all as specified and directed. |
| 26 | Supply and fixing modularswitch 6 Amps 2 way all asspecified and directed. |
| 27 | Supply and fixing modularswitch 16 Ampsall asspecified and directed. |
| 28 | Supply and fixing Bell pushmodular type SP 6 Amps all asspecified and directed. |
| 29 | Supply and fixing socketcombination out let 2/3 pin 6 Amps modular type all as specified and directed. . |
| 30 | Supply and fixing switch socket out let 2 / 3 pin 6 and 16 Amps 2 modular type all as specified and directed. . |
| 31 | Supply and fixing ceiling rose, 3 phase ,PVC polycarbonate, insulated body all as specified and directed. . |
| 32 | Supply and fix fan regulator electronic 2 modular type volts AC 50 HZ ,100 Watts,4 step complete all as specified and directed. |
| 33 | Supply and fix call bell (Ding Dong) 240 V, 50 Hz all as specified and directed. |
| 34 | M&L for lamp holder pendant/angle type insulated body with back plate all as specified and directed. |
| 35 | Supply and fixing in replacement of existing unserviceable T/L fitting 36/40 W on existing wall withNew LED Batten for LED tube light 18/20 wattswith necessary braket,clamps ,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed .Make-Make-Havells. REGALBATTENT or equivalent in Crompton/Wipro/Philips as approved. |
| 36 | Supply and fixingLED Rod tube light 18/20 wattswith necessary fixing arrangement etc complete all as specifed and directed .-Havells:PHOTONULTRAE or equivalent in Crompton/Wipro/Philips as approved. |
| 37 | Supply and fixing in replacement of existing unserviceable T/L fitting 20 W/Lamp holder on existing wall with LED light fitting 10 watts with LED tube rod, ready to use pack with necessary braket,clamps ,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed.Make-Havells-ENDURALINEARNEO or eqvt ompton/Wipro/Philips as approved. |
| 38 | Supply & fixing of surface mounting round downlight LED 12 watt luminarie complete fittingwith all fixing arrangementall as specifiedand directed . Make-Havells Cat No LHEAABP or eqvt in Crompton/Wipro/Philips as approved. |
| 39 | Supply & fixing of 30 Watt LED security light fitting with pressure dia cast housing, prismatic, polycarbonate diffuser and IP65 protection with 0.6 mtr long 20/25 mm (as per manufacturer standard)dia GI Pipe in 45 degree bend shape and necessary clamping devices required at site complete all as specifiedand directed . Havells :VILUMINASLor Philips/Wipro /Crompton as approved. |
| 40 | Supply & fixing of recess mounting 2x2 LEDluminarie, 36 W deep drawn CRCA housing with high power LED premium white powder coated frame blends seamlessly with ceiling layout, suitable for 600x600 mm modular ceiling grid and also can be suspended with provided kit, complete fittingwith all fixing arrangementall as specifiedand directed . Make-Havells : PLANO2X2 or equivalent to Wipro/Philips/ Crompton as approved. |
| 41 | Supply and fix modular White cover plate with frame, 1 module complete all as specified and directed. Make : LEGRAND/ Anchor Roma as approved. |
| 42 | Supply and fix modular white cover plate with framebut 2 module complete all as specified and directed.Make : LEGRAND/ Anchor Roma as approved. |
| 43 | Supply and fix modular white cover plate with framebut 3 module complete all as specified and directed.Make : LEGRAND/ Anchor Roma as approved. |
| 44 | Supply and fix modular white cover plate with framebut 4 module complete all as specified and directed.Make : LEGRAND/ Anchor Roma as approved. |
| 45 | Supply and fix modular white cover plate with framebut 6 module complete all as specified and directed.Make : LEGRAND/ Anchor Roma as approved. |
| 46 | Supply and fix modular white cover plate with framebut 8 module complete all as specified and directed.Make : LEGRAND/ Anchor Roma as approved. |
| 47 | M&L for submain wiring alongwith earth wire with the following sizes of FRLSPVC insulatedcopper conductor single core cable, multistrandedon the surface recess through with and including suitable size ofPVC casing and capping/PVC conduitwith its accessories all as specified and directedfor the following(a) 2x1.5 sq mm and 1x1.5 sq mm as earth wire. |
| 48 | (b) 2x2.5 sq mm and 1x2.5 sq mm as earth wire. |
| 49 | (c) 2x4.0 sq mm and 1x4 sq mm as earth wire. |
| 50 | (d) 4x6.0 sq mm and 2x6 sq mm as earth wire. |
| 51 | Supply & fix MCCB DB VTPN 4 ways,with metal double door ,IP -43 protection suitable for MCCB as incommer and MCB as out going, 415 volt 3 phase complete with appropriate size copper bus bar and neutral link confirming to cat part No-5077 45 of legrand complete including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site complete all as specified and directed.Make : Legrandor eqvt make of ABB/Siemens/L&T as approved. |
| 52 | S & F sheet metal enclosuresDB\"s 2 waySPNsingledoor suitable for 240 Vcompletefixed flush in wall including chases in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.Make :Legrand or eqvt make of ABB/Siemens/L&T as approved. |
| 53 | Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.Make :Legrand or eqvt make of ABB/Siemens/L&T as approved. |
| 54 | Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.Make :Legrand Or eqvt make of ABB/Siemens/L&T as approved. |
| 55 | Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.Make :Legrand Or eqvt make of ABB/Siemens/L&T as approved. |
| 56 | S & F MCB single pole (SP) 240 volt 06-40 amp for inductive loadconnected through cable lugs of suitable size complete all as directed and specified. Make:Legrand/ABB/Siemens/L&T as approved. |
| 57 | S & F MCB single pole and neutral (SPN) 240 volt 06-40 amp for inductive loadconnected through cable lugs of suitable size complete all as directed and specified.Make:Legrand/ABB/Siemens/L&T as approved. |
| 58 | S & F MCB Tripplepole (TP) 240 volt 40-63 amp for inductive loadconnected through cable lugs of suitable size complete all as directed and specified.Make:Legrand/ABB/Siemens/L&T as approved. |
| 59 | S & FixMCB Triple pole and Neutral 415 volts, 40-63Amps, all as specified and as directed.Make:Legrand/ABB/Siemens/L&T as approved. |
| 60 | Supply and fixingSingle pole and nuetral enclouser with two pin and earthplug and socket complete with one single pole MCB with 240 V 20 AMPs complete all as specified and directed.Make:Legrand/ABB/Siemens/L&T as approved. |
| 61 | M & L for galvanised steel earthing complete with 60 cm x 60 cm x 6 mm thick galvanised steel earth electrode and 4 mm dia galvanised earth lead wire burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to earth lead 4.0 mm dia GI wire protected by 15 mm bore light grade galvanised iron pipe and other and connected to test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron wire mesh, charcoal and common salt in alternater of 15 cm complete thickness all around the GI plate electrode complete with earth pit PCC 1:3:6 type CI and RCC 1:2:4 type B1as in cover 50 mm thick with & including reinforcement with 8mm dia TMT bar at 75 mm spacing both ways andnecesary excavation and earth work in hard/dense soil and disposal of spoilto a distance not exc 50 mtr and necessary testing complete all as shown in electrical plate No 03 connected to earthing test point including taking out old U/S earthing material complete all as directed and specified.NOTE:- Cost of earthing lead and protection pipe upto 7.5M shall deemed to be included in quoted rate. |
| 62 | S&FixLED wall mountingLight fitting,14 watt, 230 volts, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified & directed.Make :- HavellsCat Part No.LHFOECEor equivalent model of WIPRO / Philips / Jaquar as approved. |
| 63 | S&FixLED wall mountingLight fitting,9 watt, 230 volts, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. all as specified & directed.Make :- HavellsCat Part No.LHFOFUEor equivalent model of WIPRO / Philips / Bajaj and Jaquar as approved. |
| 64 | S&FixLED Decorative wall Light fitting,9 watt, 230 volts, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. all as specified & directed.Make :- HavellsCat Part No.LHFOAJDor equivalent model of WIPRO / Philips / Bajaj and Jaquar as approved. |
| 65 | Supply & fix LED 9W Tulip LED Bollard for 360 degree light with a modern look using new generation technology in LED to direct light, diffuser with IP 65 protection, resistance to impact and corrosion, glare free and better uniformity and as per site requirement with and including PCC 1:2:4 type B1 as infoundation to installed Bolladd light fitting in the garden complete all as directed and specified.Make: Havells Model: BAMBOOBLS or equivalent in Philips/Wipro/Crompton as approved. |
| 66 | S&F of LED bulkhead Lights designed to complement the geometry of the area with modern design. complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified & directed.Make :- HavellsCat Part No.RUGBYGENXFTSor equivalent model of WIPRO / Philips / Bajaj and Jaquar as approved. |
| 67 | Taking down carefully after disconnecting electrical/water supply connections and transporting to the work shop for carry out the servicing / over hauling of the storage type electric water heaters (Geysers) of storage capacity 25 / 50 litres of any make / type by cleaing the inner surface of the tank / heating element with chemical to remove the scaling / rust & reassembling the same after replacing burnt out parts and refixing on its original position including testing complete all as specifed and directed . |
| 68 | Supply & fix in replacement heating element ISI marked of the following ratings as required at site including rubber washer/packing complete all as directed and specified.Make : \"RACOLD/THEETA / SWARNA as approved.(a) 1.5/2 KW |
| 69 | Supply &fix in replacementthermostat stem type ISI marked suitable for geysers 25 / 50 litres complete all as directed and specified. |
| 70 | Supply &fix in replacement 15 mm Heavy duty connecting pipe with two brass adaptors 18 \" long & fixing in position fir cold & Hot water/inlet connection complete all as directed and specified. |
| 71 | Supply & fix in replacement Gun metal Non-Return valve 15mm dia complete all as specified. |
| 72 | Supply &fix in replacement indicator lamp rectangular / round type suitable for 25 / 50 litres geysers complete all as directed and specified. |
| 73 | Supply and fix in repair pressure release valve 15mm dia complete all as specified. |
| 74 | Material & labour for painting of storage type water heater any capacity (25/50 litres) after preparation of surface and applying two coats of synthetic enamel paint, white externally complete all as directed and specified. |
| 75 | Taking down the defective ceiling fan of any sweep andmake after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running complete all as directed and specified and comprising of the following:-(a)Servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing. |
| 76 | (b)Re-winding the burnt/short circuited winding with same guage supper enameled copper wire to maintain speed at load. |
| 77 | ( c)Painting of ceiling fan by applying one coats of synthetic enamel paint after preparation of surface complete. |
| 78 | Taking down the repairable exhaust fan of 300 MM / 380 MM sweep, any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running complete all as directed and specified and comprising of the following:-(a) Servicing/overhauling the exhuast fan by thoroughly clelaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the resistance value. |
| 79 | (b) Re-winding the burnt/shourt circuited winding with same cauge supper enameled copper wire to maintain speed at load. |
| 80 | (c)Painting of Exhaust fan by applying one coat of synthetic enamel paint after preparation of surface complete. |
| 81 | Supply & fix in replacementball bearings for exhaust/ceiling fan of any sweep complete all as directed and specified. Make : SKF/NBC/FAG as approved |
| 82 | Supply & fix in replacement GUN METAL BUSH for exhaust / ceiling fan of any sweep complete all as directed and specified. |
| 83 | Supply and fix in repairs fan condenser of following sizes :-(a) 2.5 mfd |
| 84 | (b) 4 to 6 mfd |
| 85 | Supply anf fix in repair rubber reel, nut bolts, washer, split pin complete set by dismantling existing u/s items complete all as directed and specified. |
| 86 | Supply & Fixin replacement ceiling fan down rod of MS pipe 15mm bore 1/1.2 Mtr length including cutting/threading making tide for fixing providing check nuts wachers etc complete all as directed and specified. |
| 87 | S & Fix PVC Body Exhaust fan AC single phase 220 to 240 volts 900 RPM of size 200 mm sweep with fixed on wall/ventilator andfixing arrangement complete all as specified & directed. |
| 88 | S & Fix PVC Body Exhaust fan AC single phase 220 to 240 volts 900 RPM of size 250 mm sweep with fixed on wall/ventilator andfixing arrangement complete all as specified & directed. |
| 89 | S & Fix LED RUBY (clear) 25 W LED Post top fitting, IP - 65 new genration, post top, energy saving, environmental friendly, long life aesthetically designed with symmentrical light distribution spun aluminium landscape luminaire with high powder LEDs as light source compartable for all gate piller and including GI pipe required to sizes to fixed at site by growting in wall/roof /piller/boundary wall andPCC foundation as per site requirement complete all as specified & directed.Make- Havells Model: CORALPT or equivalent in Philips/Wipro/Crompton as approved. |
| 90 | Supply and fix LED bulb /lamp 9w complete all as specified & directed. |
| 91 | Supply & fix 3 core 1.5 sqmm PVC insulated Sheathed multicore copper flexible cable connected with existing point complete all as specified & directed. |
| 92 | Supply & fix 3 core 3.5 sqmm PVC insulated Sheathed multicore copper flexible cable connected with existing point complete all as specified & directed. |
| 93 | Supply & fix 3 core 2.5 sqmm PVC insulated Sheathed multicore copper flexible cable connected with existing point complete all as specified & directed. |
| 94 | Supply & fix LED step light with die -cast aluminium hosing designed for rugged outdoor usage & IP 65 Protection BGSBL 9w LED WW complete all as specified & directed. |
| 95 | Supply and fix in replacement of LED drivers of 36 watts capacity for 2x2 LED light fittings complete all as specified & directed.Make: Havells / Bajaj or equivalent in Philips/Wipro/Crompton as approved. |
| 96 | Supply and fix in replacement of LED drivers of 8 to 12 watts capacity for LED lights complete all as specified & directed.Make: Havells / Bajaj or equivalent in Philips/Wipro/Crompton as approved. |
| 97 | Supply and fix in replacement bottom assemble of geyser any size all asspecified and directed. |
| 98 | Supply & fix PVC Box of size 4.5\" x 3\" suitable for 15 Amp switch-socket complete all as specified & directed. |
| 99 | Supply and fix 3 mm thick laminated sheet ISI mark cover fixed with brass screws and cup washers for mounting of plate mounting forhousing the switches, socket outlets, fan regulators etc complete all as specified & directed. |
| 100 | Supply and fix Double pole 30 mA RCCBs 25A for earth leakage protection all asspecified and directed. |
| 101 | Supply and fix Double pole 30 mA RCCBs 40A for earth leakage protection all asspecified and directed. |
| 102 | Taking out carefully existing defective sealed compressor of Split type AC 1.5/2 ton capacity by dismantling the same, supply and fixing new sealed compressor as per existing model and make including bracing, leak testing, vacuuming charging the oil, refrigerant as required to maintain design grill temperature, testing and commissioning in all respect all as specified and directed by Engineer-in-Charge. |
| 103 | All as per item No 85.00 above but for storage type water cooler of 40 to 60 liters capacity complete all as specified & directed. |
| 104 | M&L for taking down the existing defective fan/ blower motor and transporting to the work shop and dismantled burnt motor, removing the burnt winding & rewinding with super enameled copper wire of suitable size and gauge & replacement of unserviceable bearing of motor of following :-(a)Blower fan motorfor split type AC unit (indoor/cooling unit)Make :-USHA/ASIAN/TESLA/KELTRON/NEIL as approved. |
| 105 | (b) Condenser fan motor for water cooler 1/6 HP capacity. |
| 106 | (c) Condenser fan motor for split type AC unit condensing unit /out door unit) |
| 107 | Supply in repairs capacitors of following capacity:-(a) Capacitors 45-65 Mfd |
| 108 | (b) Capacitor 36 Mfd |
| 109 | Disconnecting and taking out the defective split type AC 1.5/2.0 ton capacity remote circuit complete and supplying and fixing new remote circuit (PCB) as per existing make/model complete all as specified and directed by Engineer-in-Charge. |
| 110 | Removing the damaged PUF insulation of suction pipe and supplying and fixing new thermal sleeve insulation for suction line including providing hard plastic tape over the thermal insulation for split type AC 1.5/2.0 ton capacity etc complete all as directed by Engineer-in-Charge. |
| 111 | Supply and fix in replacement overload protectors relays for the following:-(a) Water cooler |
| 112 | ( b) Split type AC |
| 113 | Taking out defective fan blade and supplying and fixing new blades for water cooler of 40/80/100 liters capacity complete all as directed by Engineer-in-Charge |
| 114 | Taking out defective push cock and supplying and fixing new push cock chromium plated brass, 15 mm bore of approved make for water cooler complete all as directed by Engineer-in-charge. |
| 115 | Taking out old PVC conduit condensation water pipe20mmdia from indoor unit to ground floor by using new PVC conduit ISI mark condensation water pipe 20mm dia, fixing/laying on wall by using clamps and insert into wall by making hole and grouting with cement mortar complete all as specified and as directed by Engineer-in-Charge. |
| 116 | Taking down old metallic socket neutral enclosures single pole with 2 pin and supply and fixing, new single pole and neutral enclosure with 2 pin and earth plug socket complete with one SP MCB-240 volts, 32 amps fixed on sheet metal encloser complete all as specified and directed by Engr-in-Charge. |
| 117 | Taking down Split type AC of any capacity / make/ model from existing position and carry out the servicing by cleaning the unit with water, tightening the terminal connections to avoid loose connections, applying the oiling/greasing to fan motor, bearings all as specified for smooth running including cleaning the air filter/check the thermometer setting etc complete all as specified & directed. |
| 118 | Taking down from existing position storage type water cooler of any capacity and make and servicing the same by cleaning of water tank, cleaning condensing unit by hand blower and including supply and replacement of damaged aluminium hinges, wiring with PVC insulated copper wire of same gauge, PVC drainpipe 25 mm dia, 1.5 m length, servicing/oiling/greasing of condenser motor with supply and replacement of mounting rubber bushes, tightening of all loose parts, contacts, wiring, nuts, bolts,complete including re-fixing in original position, testing and commissioning to the entire satisfaction of Engineer-in-Charge. |
| 119 | Supply and fix in replacement of relay suitable for water cooler complete all as specified & directed. |
| 120 | Supply and fix in replacement of relay suitable for split type AC of any capacity complete all as specified & directed.Make :- USHA/SHRIRAM/ ANNAPURNA as approved. |
| 121 | Supply and fix in replacement of auto cut thermostat for water cooler complete all as specified & directed. |
| 122 | Supply and charging / topping up refrigerant R-404,R-134Ato window type / split type AC complete complete all as specified & directed. |
| 123 | Supply and charging / topping up oil to window type /split type AC and Water cooler compressorsas directed by Engineer-in-charge. |
| 124 | Detecting of gas/refrigerant leakage in the system by pressure testing withnitrogen gas and rectifying the same by brazing if required replace the copper tube as required and vacuumising, recharging of refrigerant F-22 /F-12/Refron/Mafron as recommended by manufacture to maintain the design grill temperature by testing & commissioning including changing of compressor oil (CAPILA-D) for Split AC type AC 1.5/2 TR capacity complete all as specified and directed by Engineer-in-Charge. |
| 125 | All as per item No 103.00 here in before but for water cooler any type/capacity complete all as specified & directed. |
| 126 | Supply and charging / topping up refrigerant R-134 to water cooler complete all as directed by Engineer in charge. |
| 127 | Supply & fix 16 Amp Top 3 pin current rating 15 amp colour white complete complete all as specified & directed.Make :- Anchor / Havells as approved. |