}

Tender For Provision Of Oxygen Charging Bay At 118 Hu At Af Under Ge Borjhar, borjhar-Assam

Military Engineer Services has published Tender For Provision Of Oxygen Charging Bay At 118 Hu At Af Under Ge Borjhar. Submission Date for this Tender is 04-02-2023. Coats and Jackets Tenders in borjhar Assam. Bidders can get complete Tender details and download the document.




Tender Notice

35615438
Corrigendum : Tender For Provision Of Oxygen Charging Bay At 118 Hu At Af Under Ge Borjhar
Open Tender
NCB
Assam
Borjhar
04-02-2023

Tender Details

Provision Of Oxygen Charging Bay At 118 Hu At Af Under Ge Borjhar - Surface Excavation Not Exceeding 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Soft / Loose Soil All As Specified And Directed 3 Excavation In Over Areas Not Exceeding 1.5M Deep And Getting Out In Soft / Loose Soil All As Specified And Directed 4 All As Per Item Sl No. 3 Above But Depth Exe 1.50 Mtr But Not Exe 3.00 Mtr 5 Material And Labour For Providing Plain Cement Concrete ( 1:4:8 ) Type D2 Using 40 Mm Graded Aggregate As In Foundation, Filling And Mass Concrete All As Specified And Directed. 6 Material And Labour For Providing Reinforced Cement Concrete M-25 Design Mix Using 20 Mm Graded Aggregate As In Fouondation Including Rafts, Footings, Foundation Beams, Plinth Beams, Bases Ofcolumns Etc All As Specified And Directed. 7 Mmaterial And Labour For Providing Reinforced Cement Concrete M-25 Design Mix Using 20 Mm Graded Aggregate As In Col Above Plinth Beam Up To Bottom Of Roof Beam Complete All As Specified And Directed. 8 Material And Labour For Providing Reinforced Cement Concrete M-25 Design Mix Using 20 Mm Graded Aggregate As Inroof Slab Supported On Beam / Wall Etc, Complete All As Specified And Directed. 9 Material And Labour For Providing Reinforced Cement Concrete M-25 Design Mix Using 20 Mm Graded Aggregate As Inroof Beam Completeall As Specified And Directed. 10 Material And Labour For Providing Reinforced Cement Concrete M-25 Design Mix Using 20 Mm Graded Aggregate As Inlintel Beam Completeall As Specified And Directed. 11 Material And Labour For Providing Reinforced Cement Concrete M-25 Design Mix Using 20 Mm Graded Aggregate As In Chajja Completeall As Specified And Directed. 12 Use And Waste Of Form Workto Sides Of Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams, And Similar Work Vertical Or To Batterfor Rough Finished Flat Surface Of Concrete All As Specified And Directed 13 Use And Waste Of Form Workto Sides Of Columns, Pillars, Posts, Struts, Pairs And Stanchions, Rectangular Or Square For Rough Finished Flat Surfaces Of Concrete All As Specified And Directed 14 Use And Waste Of Form Work To Sides And Soffits Offloor Or Roof Beams, Beam Hunching, Girders, Lintels, Cantilevers, Shelves Including Supports, Etcfor Rough Finished Flat Surfaces Of Concreteall As Specified And Directed. 15 M & L For Formwork To Sides& Soffit Of Chajja Etc Fair Finished Surfaceall As Specified And Directed. 16 M & L For Formwork To Sides& Soffit Of Roof / Floor Beametc Fair Finished Surface All As Specified And Directed. 17 M & L For Formwork To Sides& Soffit Of Roof / Floor Slabetc Fair Finished Surfaceall As Specified And Directed. 18 M & L For Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And Directed. 19 All As Per Item Sl No. 18Above But 8 To 10 Mm Dia 20 All As Per Item Sl No. 18Above But 8 To 10 Mm Dia As In Stirrups, Binders Etc 21 Returning, Filling In Trenches Including Spreading, Leveling Watering And Ramming In Layers Not Exceeding 25Cm All As Directed. 22 Removing Of Surplus Soil Not Exceeding 50 M And Deposited Where Directed At A Level Not Exceeding 1.50M Above The Starting Point All As Directed. 23 Material And Labour For Brick Work With Locally Available Sub Class ‘B’, Old Size, Best Quality Bricks, Straight Or Curved On Plan Exc 6 M Mean Radius Built In Cement Mortar ( 1:6 ) All As Specified And Directed. 24 M&L Brickwork In Cm 1:6 With Subclass B Bricks , Straight Or Curved On Plan To Any Radius In Half Brick Thick Walls Complete All As Specified & Directed . 25 Material And Labour For Earth Filling In Plinth Layer Incl Watering & Well Consolidation Complete All As Specified & Directed . 26 Material And Labour For Sand Filling Under Floors Or In Foundation Including Watering And Consolidation All As Specified And Directed. 27 Material And Labour For Providing Plain Cement Concrete ( 1:5:10 ) Type E2 Using 40Mm Graded Aggregate As In Sub Base Of Floor All As Specified And Directed 28 M & L For Polythene Film, 150 Micron Thick, Laid On Floor Complete All As Specified & Directed 29 M & L For Rendering 15 Mm Thick On Other Fair Faces Of Brick Worksurfaces In Cm ( 1:6 ) As In Internal Plastering, Finished Even & Smooth Without Using Extra Cement Complete All As Specified & Directed 30 M & L For Rendering 15 Mm Thick Onfair Faces Of Brick Worksurfaces In Cm ( 1:4 ) As In External Plastering, In Two Layers ( 10 + 5 ) Top Coat Of 5 Mm To Be Mixed With Wpc@ 3% Of Cement, Finished Fair & Even Complete All As Specified & Directed 31 M & L For Rendering 5 Mm Thick On Soffit Of Rcc Ceiling & Chajjasurfaces In Cm ( 1:3 ) , Finished Even & Smooth Without Using Extra Cementcomplete All As Specified & Directed 32 M & L For Preparing Thenew Plasterd Surface Of Ceiling & Applying Three Coats Of White Washing Complete All As Specified & Directed 33 Supply Only Integral Water Proofing Compound Isi Marked. 34 M & L For Preparing Thenew Plasterd Surface Of External Wall & Applying Two Coats Of Exterior Emulsion Paint Over A Coat Of Primer ( Camoflauge Pattern ) Complete All As Specified & Directed 35 M & L For Preparing Thenew Plasterd Surface Of Internal Wall & Applying Two Coats Of Oil Bound Distempering Over A Coat Of Primercomplete All As Specified & Directed 36 M & L For Pcc 1:2:4 Type B1 Using 20 Mm Graded Stone Aggregate As In Sub Base Of Floor 40 Mm Thick Finished Rough To Receive Tiling / Kota Stone Etccomplete All As Specified & Directed 37 Material And Labour For Screed Bed Or Bedding Layers 15 Mm Thick In Cement Mortar ( 1:6 ) For Laying Floor Finishes All As Directed. 38 Material And Labour For Screed Bed Or Bedding Layers Of 15 Mm Thick Cement Mortar ( 1:4 ) For Laying Floor Finishes All As Specified And Directed 39 M & L For Machine Cut Kota Stone Slab Flooring 20-25Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbingand Polishing Completeall As Specified And Directed 40 All As Per Item Sl No. 39 But In Vertical Surface Of Skirting. 41 M & L For Rendering 10 Mm Thick On Top Of Rcc Roofsurfaces In Cm ( 1:4 ) , & Applying 3 Mm Thick App Felt Incl Priming Surfaces With Bituminus Primer @ 0.40 Kg / Sqmcomplete All As Specified And Directed 42 S / F For Steel Rolling Shutters, With Out Ball Bearing, As Specified Including Top Cover, Anchoring Rod, Hasp And Staple And One Shop Coat Of Primer; Erected In Position As Indicated, Complete: Push Pull Or Manual Type. Thickness Of Laths Is 1.00 Mm Complete All As Specified And Directed . 43 S / F For Safety Lever Locks Mild Steel With 4 Levers For Rolling Shutters Complete All As Specified And Directed 44 M & L For Anodised Aluminium Frame ( Powder Coated ) For Doors, Windows, Ventilators Frame With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified 45 M & L For Anodised Aluminium Window And Ventilator Shutters ( Powder Coated ) , Side Hung Type Without Sash Bars, Aluminium Sections Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Anodised Aluminium Fittings Such As Peg Stays 150Mm Long ( 1 No. ) . Hinges Type B-21 100Mm Long ( 2 No. ) Suitable Handle ( 1 No. ) Complete All As Specified. 46 Supply And Fix Sheet Glass 3.0 Mm Thick Ordinary Quality And Glazing With Beads Not Exc. 0.50Sqm In Each Pane All As Specified And Directed. 47 M & L For Anodised Aluminium Door Shutters ( Powder Coated ) , Aluminium Section Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Ruber Neoprene Packing, Handles 2 Nos In Each Door, Hinges, Anodised Aluminum Snap Beading Screws Etcsupply And Fix Sheet Glass 3.0 Mm Thick Ordinary Quality And Glazing With Beads Not Exc. 0.50Sqm In Each Pane All As Specified And Directed. 48 S & F For Mortice Lock Four Lever Aluminium Body For Aluminium Door Complete All As Specified And Directed . 49 S & F For Floor Door Stopperaluminium Body For Aluminium Door 150 Mm Complete All As Specified And Directed .. 50 S & F For Door Closer Hydraulically Regulated, Designation No. 1 Universal Type, Suitable For Door Shutters Up To 700 Mm In Width And Of Weight Not More Than 35 Kg And Fixed. 51 M & L For Framed Brackets Of Angles Or Tees With Web And Flanges Cut To Shape, Drilled And Countersunk For Screw, Including Bending And Welding Angles, As Necessary, Gusset Plates, Riveting, Etc.. N Exc 10 Kg Each Brackets, Conforming To Fe.290.Gde-E-165 ( Brackets Over 10 Kg Each To Be Measured Under Structural Steel ) Complete All As Specified And Directed . 52 M & L For Mild Steel Plates, Plain Or Chequered, 5Mm Thick Or Over In Thickness In Available Sizes, Cut To Shape. Hole Drilled As Required Fixed In Position With Welding Or Nut Bolt Arrangement, All As Directed. 53 Material And Labour For Preparation Of New And Previously Un-Treated Steel Surfaces Of Any Description, Not Otherwise Described Over 10Cmwidth Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer All As Specified And Directed. 54 M & L For Hard Core Of Gauge N Exc. 63 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface As In Plinth Protection Complete All As Specified And Directed . 55 Material And Labour For Providing 75 Mm Thick Cement Concrete ( 1:3:6 ) Type Ci Using 40Mm Graded Aggregate As In Plinth Protection Surfaces Even And Smooth Without Using Extra Cement All As Specified And Directed. 56 M & L For Pcc 1:2:4 Type B2 Using 40 Mm Graded Stone Aggregate As In Foot Path 75 Mm Thick Finished Even & Smooth Without Using Extra Cement & Making Xpm Impression Whilest The Concrete Is Green Complete All As Specified And Directed . 57 S 7 F For Mild Steel Screw Bolts ( Machine Made ) Withhexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, & One Washer Complete All As Specified And Directed . 58 Excavation In Trenches Not Exceeding 1.50 Metre Wide And Not Exceeding 1.50 Metre In Depth And Getting Out In Soft / Loose Soil All As Specified Anddirected. 59 Schedule A / Boq Of E / M Works 60 Supply And Spread Sand In Trenches As Sand Cushioning To Underground Cable For Protection With Fine River Sand And Provide Required Cover After Punning Down Complete All As Specified And Directed.Note : For The Purpose Of Payment Only Punned Thickness Will Be Measured. ( Note: Thickness Of Sand Cushion After Punning Down Will Be Measured And Paid. ) 61 M&L For Common Burnt Clay Building Bricks ( Locally Available Best Quality ) , Sub-Class ‘B’ Designation 75 Of Size 230X115x75 Mm To Cover Lt Underground Cables , Laid Dry And Flat Abutting Each Other With Gaps Not Exceeding 10Mm Complete All As Specified And Directed. 62 M & L For Plain Cement Concrete ( 1:3:6 ) Type C-2 Using 40 Mm Graded Stone Aggregate In Foundation Of Pole / Strut / Mass Filling Including Necessary Form Work All As Specified And Directed By Engineer-In-Charge. 63 Supply, Laying Connecting And Testing Xlpe Insulated, Pvc Sheathed, Armoured Lt Electric Power Ug Cable Of Size 25 Sqmm 2 Core ( Heavy Duty ) , Aluminium Strandedconductor 1100 Volts Grade, Laid Through Duct / Pipe / In Trench Etc. Including Cable Glands & Lugs Complete All As Specified And Directed. 64 Supply, Laying Connecting And Testing Xlpe Insulated, Pvc Sheathed, Armoured Lt Electric Power Ug Cable Of Size 95 Sqmm 3.5 Core ( Heavy Duty ) , Aluminium Strandedconductor 1100 Volts Grade, Laid Through Duct / Pipe / In Trench Etc. Including Cable Glands & Lugs Complete All As Specified And Directed. 65 M&L 40 Mm Bore Gi Tubing“Light Grade” In Trenches / On Pole For Protection Of Cables Complete All As Specified & Directed By Engineer-In-Charge. 66 Supply, Install, Testingand Commissioning Outdoor Type Lt Feeder Pillar Of Suitable Size From Any Cpri Type Tested Manufaturermade Out Oftotally Encloseddust And Vermin Proof , Double Leaf Shutter In Front And Single Leaf Shutter In Rear Side Made Of 3.15 Mm Thick Crca Sheet, Duly Fabricated And Having Proper Locking Arrangement In Both Front And Rear Door Painted With Powder Coated Paint And Aluminium Bus Bar 400 Amps Suitable For 500 Volts, 50 Hz , 3 Phase 4 Wire System And Comprising With And Including Following Accesories And Mounted On Pcc Platform All Around The Panel Board Complete With The Following Items:-Incoming :- ( A ) Mccb, 4 Pole, 200 A, 415 V 25 Ka ( I / C ) With Adjustablethermal & Magnetic Release-1Nos. Make-Abb / Siemens / Legrand / Schneider ( B ) Lcd Multifunction Meter, Make-Abb / Siemens / Legrand / Schneider ( C ) On Load Changeover Switch Of Capacity 200 Amp.Make-Abb / Siemens / Legrand ( D ) Ct Coil Of Ratio 200 / 5A-Set Of 3.Make-Kappa / Ae ( E ) Phase Indicator Lamps ( Ryb ) -Set Of 3Make-Schneider, L&T, Seimens ( F ) Aluminium Bus Bar 4 Strip 67 ( G ) Internal Wiring For Panel Incl Insulators, Sleeves Etc Outgoing :- ( A ) Mccb, 4 Pole, 200 A, 415 V 25 Ka ( O / G ) With Adjustablethermal & Magnetic Release-1Nos. Make-Abb / Siemens / Legrand / Schneider 68 Supply, Install, Testingand Commissioning Outdoor Type Lt Feeder Pillar Of Suitable Size From Any Cpri Type Tested Manufaturermade Out Oftotally Encloseddust And Vermin Proof , Double Leaf Shutter In Front And Single Leaf Shutter In Rear Side Made Of 3.15 Mm Thick Crca Sheet, Duly Fabricated And Having Proper Locking Arrangement In Both Ront And Rear Door Painted With Powder Coated Paint And Aluminium Bus Bar 150 Amps Suitable For 500 Volts, 50 Hz , 3 Phase 4 Wire System And Comprising With And Including Following Accesories And Mounted On Pcc Platform All Around The Panel Board Complete With The Following Items:- 69 Incominga ) Mccb, 4 Pole, 100 A, 415 V 25 Ka ( I / C ) With Adjustablethermal & Magnetic Release-1Nos, Make-Abb / Siemens / Legrand / Schneider ( B ) Phase Indicator Lamps ( Ryb ) -Set Of 3.Make-Schneider, L&T, Seimens ( C ) Aluminium Bus Bar 4 Strip ( D ) Internal Wiring For Panel Incl Insulators, Sleeves Etcoutgoing ( A ) Mccb, 4 Pole, 100 A, 415 V 25 Ka ( O / G ) With Adjustablethermal & Magnetic Release-1Nos.Make-Abb / Siemens / Legrand / Schneider ( B ) Mccb, 3 Pole, 40 A, 415 V 16 Ka ( O / G ) With Adjustablethermal & Magnetic Release-3Nos.Make-Abb / Siemens / Legrand / Schneider 70 Material And Labour For Point Wiring With 1.5 Sqmm Fr Pvc Insulated And Sheathed Multi Stranded ( Frlsh ) Flexible Copper Conductor Cable Inand Incl Rigid Pvc Conduit Concealed / Pvc Surface Conduit With Sunk Cast Iron / Pressed Steel Terminal Boxes Ofadequate Size With Suitable Thickness Hylum Laminated Sheet , Coverofadequate Size For One Light Or One Fancontrolledby One Switch Incl 1.5 Sqmm ( Frlsh ) Pvc Insulated Andunsheathed Multi Stranded Flexible Copper Conductor Cable As Earth Wire ( Green Colour ) To Common Earth Dolly Complete All As Specified And Directed By Engr-In-Charge. Note:- ( A ) Unit Rate Include For Cutting Chases For Conduits And Sinking For Boxes And Making Good To Wall, Floors Etc ( B ) On Rcc Roof Ceiling Pvc Conduit Shall Be Provided On Surfaces For Fan Etc With Proper Fixing Clips All As Directed 71 All As Per Serial Item No 70 Here In Before But For One 3 Pin 5 Amp Socket Outlet On Independent Board. 72 All As Per Serial Item No 70 Here In Before But For One 3 Pin 5 Amp Socket Outlet On Same Board. 73 Material And Labour For Point Wiring With 4.0 Sqmm Fr Pvc Insulated And Sheathed Multi Stranded ( Frlsh ) Flexible Copper Conductor Cable Drawn In And Including Rigid Pvc Concealed Conduit Medium Grade Of Suitable Size With Sunk Cast Iron / Pressed Steel Terminal Boxes Of Adequate Size With Suitable Thickness Plastic Laminated Sheet, Cover For One 3 Pin Socket Outlet 15 Amp On Independent Board Including Continuous 4.0 Sqmm Copper Conductor Cable ( Frlsh ) ( Multistranded ) Pvc Insulated And Unsheathed Cable As Earth Wire To Common Earth Dolly, Complete All As Specified And Directed By Engr-In-Charge 74 Supply And Fixing Of Switch Piano Flush Type 240 Volts 6 Amps, Sp, One Way Complete All As Specifed / Directed. 75 Supply & Fixing Of Socket Outlet 3 Pin, 6A, Flush Type240 Volts ( Non Shuttered ) Complete All As Specified Directed. 76 Supply And Fixing Of Switch Socket Outlet Combination 5 Pin, 6 Amps, 240 Volts Flush Type ( Non Shuttered ) Complete All As Specified / Directed. 77 Supply And Fixing Switch Socket Out Let Combination Multipurpose 3 Pin, 6 / 16 Amps And ( With 3 Pin 6 Amps Outlet Also ) Flush Type ( Non Shuttered ) Complete All As Specified Directed. 78 Material And Labour For 100W Deluxe Fan Regulator With 5 Step Speed Control Isi Marked, Complete All As Specified And Directed By Engr-In-Charge 79 Material And Labour For Ceiling Rose Surface Bakelitetwo To Three Terminal Isolated Body Fixed On Pvc Round Block, 6A, Pilot 2 Plate, Complete All As Specified And Directed. 80 Supply And Fixing Of Led Fitting 1X18watts Including Tube Rod, 230 Volts, Bipin Holders Connector Block Etc.Complete With All Accessories Internally Pre-Wired And Includingprovision Of Pvc Round Block 7.5Cm Dia And 2 Cm In Depth ( 2 Nos ) For Mounting The Fittings And Electrically Connecting With Three Single Core 23X0.0076 Pvc Insulated Multistranded Copper Conductor Flexible Cable From Ceiling Rose To Light Fitting, Complete All As Specified And Directed. 81 Supply And Fix In Repairs Of Mcb Spn Db 4 Way Double Door, Glazed Type, Ip 43 Protection, Glazed Door, Isolated Neutral Bar, Insulated Bus Bar Assembly, Mechanical Strength Of Ik09, Complete All As Specified And Directed. Make- Legrand / Indo Asian / Havells Or Its Equivalent In Specified Makes In Ca. 82 Supply & Fix In Repair Of Mcbs Single Pole ( Spn ) 6 To 32 Amps With 10 Ka Breaking Capacity Of C Curve In Distribution Boards Confirming To Is / Iec 60898-1 ( Isi Merked ) Complete All As Specified And Directed. 83 Supply & Fix In Repair Of Mcbs Single Pole ( Sp ) 6 To 32 Amps With 10 Ka Breaking Capacity Of C Curve In Distribution Boards Confirming To Is / Iec 60898-1 ( Isi Merked ) Complete All As Specified And Directed. 84 M&L For Earthing Complete With Galvanized Steel Earth Plate Electrode 600X600x6mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metre Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Metre Below Normal Ground Level, Connected To Galvanized Earth Lead Wire 4.0 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanizediron Or Steel All As Shown In Electrical Plate No.5 Of Ssr Part-I ( 2009 ) Including Filling Of Charcoal Dust , Common Salt All Around Earth Plate Upto 150Mm, 20Mm Bore Gi Medium Grade Watering Pipe, 15 Mm Bore Light Grade Earth Lead Protection Pipe Upto Main Board, Funnel With Wiremesh, 40Mm Thickrcc 1:2:4 Type B-1 Using 20 Mm Graded Crushed Stone Aggregate Reinforced Withsuitable Handle And Angle Iron Frameand Necessary Excavation And Earth Work In Any Type Of Soil Etc. Complete All Asspecifiedand As Directed Includingtesting On Completion. ( Note: The Rate Quoted Include Cost Of Min 7.5 Metre Earthing Wire . ) 85 Supply And Fix Of Ceiling Fan 1200 Mm ( Minimum ) Sweep, With Service Value 6.00 Bee 5 Star Rated With Bldc Technology, Ac Single Phase 230 Watt, Suspected From Fan Hook And Including Electrically Connecting With Twisted Three Core Pvc Insulated Unsheathed Flexible Cord Of 0.75 Sqmm Copper Conductor From Ceiling Rose To Ceiling Fan Including Taking Down Of Old U / S Fan, Complete All As Specified And Directed. Note:- ( 1 ) Five Years Warranty Shall Be Given By Contractor For Bldc Ceiling Fan.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 24-01-2023 Tender ammendment Date 28-01-2023
2 28-01-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 48000.0 /-
Tender Value
INR 24 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail