Tender For Welcome Maintenance And Misc B/R And E/M Items In Single/Md Offrs Accn Under Ge Jaipur At Jaipur Mil Stn, jaipur-Rajasthan

Military Engineer Services has published Tender For Welcome Maintenance And Misc B/R And E/M Items In Single/Md Offrs Accn Under Ge Jaipur At Jaipur Mil Stn. Submission Date for this Tender is 28-01-2023. Coats and Jackets Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

35548989
Corrigendum : Tender For Welcome Maintenance And Misc B/R And E/M Items In Single/Md Offrs Accn Under Ge Jaipur At Jaipur Mil Stn
Open Tender
Indian
Rajasthan
Jaipur
28-01-2023

Tender Details

Tender For Welcome Maintenance And Misc B / R And E / M Items In Single / Md Offrs Accn Under Ge Jaipur At Jaipur Mil Stn - Taking Down Cement Plaster On Brick / Stone Wall, Ceiling Etc Incl. Raking Outs Joints Hacking For Key Scrubbing With Water Complete All As Specified And Directed 2 M&L For Rendering 15Mm Thick On Fair Face Of Brick Or Concrete Surface In Cm ( 1:6 ) Surface Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed 3 M&L For Preparation Of Newly Plastered Or Unplastered Surface Of Wall And Applying Two Coats Of Exterior Emulsion Weather Proof Paint And One Coat Of Primer On Walls Complete All As Specified & Directed 4 M&L For Preparation Of Newly Plastered Or Unplastered Surface Of Wall And Applying Two Coat Of Interior Emulsion Weather Proof Paint And One Coat Of Primer On Walls Complete All As Specified & Directed 5 M&L For Preparing Old Painted Surfaces Of Steel Using Sand Paper Gentle Rubbing To Obtain Smooth Surfaces And Applying Two Coat Of Synthetic Enamel Paint Complete All As Specified. 6 M&L For Complete Removal Of Existing Treatment And Applying Two Coat Of Exterior Emulsion Weather Proof Paint And One Coat Of Primer On Walls Complete All As Specified & Directed 7 M&L For Complete Removal Of Existing Treatment And Applying Two Coat Of Interior Emulsion Weather Proof Paint And One Coat Of Primer On Walls Complete All As Specified & Directed 8 M&L For Complete Removal Of Existing Treatment And Applying Two Coat Of Interior Emulsion Weather Proof Paint And One Coat Of Primer On Ceiling Surface Complete All As Specified & Directed 9 M&L For Preparing Old Surface Of Wall And Applying Acrylic Paint On Wall, Jallie, Rcc Pillars Etc Complete All As Specified & Directed 10 M&L Forpreparation Of Surfaces And Applying Two Coat Of Varnishing To Old Wooden Surfaces Over 10Cmwidth Or Girth Complete All As Specified & Directed 11 M&L For Preparing Old Painted Surfaces Of Wood Or Wood Based Materials Over 10 Cm Width Or Girth Of Any Description & Applying Two Coat Of Synthetic Enamel Paint Complete All As Specified. 12 M&L For Complete Removal Of Existing Treatment Of Old Plastered Surfaces Of Wall And Applying Two Coats Of Distemper Oil Emulsion, White Or Tinted Complete All As Specified And As Directed 13 Dismantlingof Brick Work Built In Cement Mortar Including All Quions Arches Pillars Etc Complete All As Specified And As Directed 14 M&L Forbrick Work With Sub Class B Bricks Straight Or Curved On Plan Exc 6M Meanradius Brick Wallsbuilt In Cm 1:6 Complete All As Specified And As Directed 15 Dismantling Of Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided Complete All As Specified And As Directed 16 M&L For Framed Work Such As Grils, Grating Etc With End Of Bars Shoulders And Or Riveted Or Forged Into Spike, Framed Guard Bars , Barred Iron Doors, Ladders Framed Balusters, Walk Ways Rallings, Framed Work Of Water Tanks And Similar Works Conforming To Fe-290, Gde-165 Complete All As Specified And As Directed 17 M&L For Cement Concrete In Foundations, Filling And Mass Concrete In 1:3:6 Complete All As Specified And As Directed 18 M&L For Preparation New Steel Treated Or Untreated Surface Of Any Description Not Otherwise Described Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Complete All As Specified And As Directed 19 M&L For 16-18Mm Thick Dholpur Stone Cladding Gang Saw Cut With Machine Cut Edges, Uniform Colour Of Each Stone Size Exceeding 0.25 Sqm Area And Not Exceeding 0.5 Sqm Fixed With And Including One Number Ss Clamps ( Grade -202 ) Of Flat30mm X 2Mm, 150Mm Long Made To Shape In Each Slab, Making V Groove At Top And Bottom Of Stone And Drilling Hole For Hold Fastener, Polishing, Rubbing & Including Silicon Treatment Complete All As Specified And As Directed 20 S&F In Repair Precast Cement Concrete Louvres And Jallies, Type B0, 1:2:4 U ( Sing 12.5Mm Garded Stone Aggregate ) Set In Cm 1:4 Including Pillars For Finshing At Regular Interval Complete All As Specified And As Directed ( Pre Cast Frame Shall Be Measured Separately And Paid For Under Respective Item ) 21 Demolition Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc., Laid, Bedded And Pointed In Any Mortar Complete All As Specified And As Directed 22 M&L For Machine Pressed Precast Concrete Interlocking Paver Block Of Approved Shape And Size Confirming To Is 15658-2006 Of 60Mm Thickness, M-35 Grade, With Grey Cement And Pigment Laid Over And Including 25Mm Thick Sand Cushion Complete All As Specified And Directed 23 M&L For Pre-Cast Cement Concrete Block Masonry With Solid Blocks, Exc 10 Cm In Width And Setting In Mortar Complete Type 1:2:4 Set In Cement Mortar Complete All As Specified And Directed 24 M&L For 75Mm Thick Cement Concrete Type D-2, 1:4:8 Complete All As Specified And Directed 25 M&L For Chequered Cement Concrete Tiles 20Cmx20cmx25mm Thick, Set, Jointed And Pointed In Neat Cement Slurry In Floors With Grey Cement And No Pigment Over And Incl 15 Mm Screed In 1:6 Complete All As Specified And Directed 26 Taking Down Chowkhats Or Framesexc. 1.50Sqm Each But N Exc 4 Sqm With Shutter ( Without Taking Of Shutter From The Frame ) Complete All As Specified And Directed 27 M&L For Anodised Aluminium Frame For Doors, Window, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Ccomplete All As Specified And Directed 28 S&F 2Nd Class Hard Wood Plain, Solid, Straight Chowkhats And Frame, Wrought, Framed Rebated On The Solid, Rounded Or Chamferd Put Together With Glue Pinned At Joints Complete All As Specified And Directed 29 M&L For 2Nd Class Hard Wood 35Mm Glazed And Skelton Shutter Open Rebated And Prepared To Receive Glass, Gauge Etc. ( Without Sash Bars ) Edges Of Framing Plain Chamfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass Etc. Complete All As Specified And Directed 30 S&F Plain Framed Panelled Shutters 2Nd Class 30Mm Thick ( Any Numbers Of Panel ) With Panel Of Timber Flat On Both Sides ( Feather Edged Or Of Veneered Particle Board Medium Density, Wood Particle Board With Commercial Faces Veneers, And Fixed To Chowkhat Complete All As Specified And Directed 31 S&F 30 Mm Thick Preliminated Particle Board Interior Grade Prelaminated One Side With Decorative Choice Lamination & Other Side Balancing White Lamination Fixed With Screwed To Timber Frame Work As In Shelves In Kitchen, Almirah, Cup Boards Complete All As Specified And Directed. 32 S&F Solidpvc Door Frame Of Size 50Mmx47mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With Ms Square Tube All As Specified And Approved. 33 S&F Factory Made Solid Panel Pvc Door Shutter Withms Square Tube30mm Thick ( Style ) Consisting Of Frame Made Out Of Ms Tubes For Top And Bottom Rails Ms Frame Shall Be Covered With Heat Moulded Plain Colour Pvc Sheet Stirip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top, Lock And Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail .Panelling Of Plain Colourpvc Sheet To Be Fitted In The Ms Frame Welded / Sealed To The Stiles And Rails With Suitable Pvc Sheet Beading And Joined Together With Solvent Cement & Fix In The Frame At Site Complete All As Specified And Directed 34 S&F Butt Hinges Stainless Steel With Screw Fixed Of 100Mm Size Complete All As Specified And Directed 35 S&F Aluminium Anodised Barrel Tower Bolt Of Extruded Section Of 150Mm Complete All As Specified And Directed 36 S&F Aluminium Handles Cast Type Anodised Of 150Mm Complete All As Specified And Directed 37 Taking Down Or Up, 15 Mmboregalvanisedsteel Tubing And Connections Including Cleaning For Refixing Or Removalcomplete All As Specified And Directed. 38 S&Fgi Tubing Medium Grade With All Fitting And Fixedto Walls & Ceilings Or Laid In Floors, Bore Of Pipe 15Mmcomplete All As Specified And Directed. 39 Taking Down Or Up, 20 Mmboregalvanisedsteel Tubing And Connections Including Cleaning For Refixing Or Removalcomplete All As Specified And Directed. 40 S&Fgi Tubing Medium Grade With All Fitting And Fixedto Walls & Ceilings Or Laid In Floors, Bore Of Pipe 20Mmcomplete All As Specified And Directed. 41 M&L For Cutting Chases, Pinning In Making Good To Facing Where Requried And Pointing In Cement Mortar 1:3 To Ends Or Edge Of Landings, Steps, Cills, Sunshade, Shelves, Lintel Etc. Tubes Or Concealed Conduit Etc. And Making Good, Cutting Not Exc 10 Cm Girth Complete All As Specified And Directed. 42 S&F In Repair 1000 Litre Capacity Rotational Moulded Polyethylene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position Complete All As Specified And Directed. 43 S&F In Repair 500 Litre Capacity Rotational Moulded Polyethylene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position Complete All As Specified And Directed. 44 S&F In Repair 15Mm Ball Valve High Pressure Of Ptmt With Epoxy Coated Almn Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixedfixed Complete All As Specified And Directed. 45 Disconnecting Existing Tanks, Capacity 500 Ltr Setting Aside ( Or Lowering If Required ) For Repair And Cleaning Etc. And Hoisting If Required, Cleaning And Removing All Scale And Dirt, From Tanks And From Mouth Of Curculating Pipe And Reconnecting And Re-Fixing In Position Complete All As Specified And Directed. 46 Disconnecting Existing Tanks, Capccity 1000 Ltr Setting Aside ( Or Lowering If Required ) For Repair And Cleaning Etc. And Hoisting If Required , Cleaning And Removing All Scale And Dirt, From Tanks And From Mouth Of Curculating Pipe And Reconnecting And Re-Fixing In Position Complete All As Specified And Directed. 47 Taking Down Existing Roof Treatment Complete Including Pcc And Properly Clean The Surface To Remove Loose Particles With Wire Brushes And Removing The Debris Out Side Of Mod Land Complete All As Specified And Directed. 48 M&L For Screed Plaster 15 Mm Thick In Cm 1:4 On Roof Surface Complete And Finished The Surface Even And Smooth Without Using Extra Cement Etc. Complete All As Specified And Directed 49 M&L For 3 Mm Thick ( Min ) Layer Of App Based Polymeric Membrane, Weighing Not Less Than 3.5 Kg / M2 Reinforced With Polyster Non Woven Fabric ( Weighing Not Less Than 150 Gms / Sqm ) . The Surface Shall Be Painted With One Coat Of Polymeric Primer @ 0.40 Kg Per Sqm, Conforming To Is: 3384 Before Laying Of Membrabe. Side Over Laps Shall Be 75Mm And The End Lap Shall Be 100Mm And All Over Laps And Joints Shall Be Sealed By Torch Application.For Parapets, Membrane Shall Be Taken To A Height Of Minimum 60Cm And Then Inserted Inside The Parapet Groove All As Per Manufacturer Instructions Andapplying One Coat Of Bitumen @ 1.2 Kg / Sqm On App Membrane. The Top Layer Shall Be Painted With Two Coats Ofaluminium Paint Complete All As Specified And Directed. ( The Work Shall Be Carried Out By Authorised Applicator ) 50 M&L For 25 Mm Thick Cement Concrete Type B-0, 1:2:4 ( 12.5 Mm Graded Stone Aggregates ) On Roof Surface Complete All As Specified And Directed 51 Dismantlingexisting Terrazo Dado / Flooring Or Tilles In Bath, Wc And Kitchen Etc. Complete All As Specified And Directed 52 M And L For Vitrified Ceramic Tiles 9-10Mm Thick ( Square / Rectamgular ) Polished, Area Of Each Tiles Exc. 0.36 Sqm But N Exc 0.42 Sqm In Floorsset And Jointed In Neat Cement Slurry And Pointed Incoloured Cement To Match The Floor Laid Over & Including 15Mm Thick Screed In Cement Mortar 1:6 Complete All As Specified And Directed 53 All As Per Item No. 52Above But On Vertical Surface Over & Including 10 Mm Thick Rendering In Cm ( 1:4 ) Complete All As Specified And Directed 54 M&L For Coloured Non Skid Ceramic Tiles 300Mm X 300Mm X 7Mm Thick In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match Over & Including 15Mm Thick Screed Bed In Cm 1:6 Complete All As Specified And Directed 55 M And L For Coloured Glazed Ceramic Tiles350mm X450mm X7mm Thickset And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Flooras On Vertical Surfaces Laid Over & Including 10Mm Thick Cement Screed In 1:4 Complete All As Specified And Directed 56 Hacking Out Old Broken Glass ( Any Thickness, Size, Quality Or Description ) Fromwooden Frame Or Stone Concrete Or Brick Surrounds Glazed With Putty Or Fixed With Beads Complete All As Specified And Directed 57 M And L For Sheet Glass 3Mm Thick Ordinary Quality And Glazing With Oil Putty In Square Not Exc.0.5Sqm In Each Pane Complete All As Specified And Directed 58 S&F Wire Netting Of Stainless Steel Wire 1.4 Mm Dia Fixed With Tinned Tack Of Stainless Steel Wire Steple Size Of Mess 12 Mm Complete All As Specified And Directed 59 S&Fpvc Valve Less, Symphonic Action Type, Flushing Cistern, Low Level White With Inlet, Ball Valve, Float And Handle Including Brackets 10Litres Complete 60 S&F Pvc Connection 15Mm Size With Brass Nuts And Spanner Of Length 600Mm Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 61 S&F Cast Iron Floor Trap 75Mm Incl. Cp Grating And Removing Of Old Trap Any Type And Shape Complete All As Specified 62 S&F Angle Cock ( Spiro ) 15 Mm Dia Cp Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 63 S&F Concealed Stop Cock With Flange 15 Mm Dia Cp Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 64 S&F Floor Door Stopper Of Brass Body And Tongue, Anodised, With Hard Drawn Steel Spring, Fixed In Floor; Overall Length Of Cover Plate 150Mm Complete All As Specified And Directed 65 S&F Brass Handle Cast Type, Polished Bright Any Size And Any Shape Complete All As Specified And Directed 66 S&F Brass Sliding Door Bolts 250 Mm Long With Sand Or Die-Cast Brass Hasp, Steple ( Bolt Type ) And Fixing Bolt With Rolled Or Drwan Brass Bolts And Fixed Complete All As Specified And Directed 67 Dimantling Pipes Of Any Description Fixed To Wall Or Laid Under Floor Complete All As Specified And Directed 68 S&F Pvc ( Swr ) Single Socketed In Any Length With Rubber Ring Joint Fixed With Wall, Floor Of 75Mm With Suitable Ss Clamp Complete All As Specified And Directed 69 S&F Pvc ( Swr ) Single Socketed In Any Length With Rubber Ring Joint Fixed With Wall, Floor Of 110Mm With Suitable Ss Clapm Complete All As Specified And Directed 70 S&F One Piece Closet With Integrated Cistern, Seat Cover And Twin Flushing Fittings Ewc Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 71 S&F Concealed Cistern In Wall With Top Push Know Suitable For All Type Wall Hung Wc Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 72 S&F Art Basin Most Popular Counter Top Wash Hand Basin Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 73 S&F 200 Mm Square Rain Shower With Cp Arm 150 Mm Long Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 74 S&F Hand Shower Abs Multi Flow With 1.5 Mtr S.S Flexible Tube & Hooks Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 75 S&F Health Faucet With 1 Mtr S.S Tubes And Hooks Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 76 S&F Sink Mixer With Regular Spout 15 Mm Bore Dia Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 77 S&F Wall Mixer With L-Bend For Overhead Shower 15 Mm Bore Dia Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 78 S&F Single Lever Basin Mixer W / O Pop Up Waste System 15 Mm Bore Dia Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 79 S&F Glass Shelf 300 Mm With Brass Screw All As Specified And Directed. ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 80 S&F Corner Glass Shelf 200 Mm Size With Brass Screw Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 81 S&F Looking Mirror Double Arm Wall Mounted Reversible Plain / Magnifying ( X3 ) Pivotal Mirror With Brass Screw Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 82 S&F Looking Mirror 600Mm X 450 Mm With Frame And S S Clamp Suitable Size Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 83 S&F Grab Bar 300 Mm Long Stainless Steel With Fixing Brass Screw Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 84 S&F Soap Dish Stainless Steel With Fixing Brass Screw Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 85 S&F Toilet Paper Holder Stainless Steel With Suitable Fixing Arrangements Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 86 S&F Tumbler Holder Stainless Steel With Suitable Fixing Arrangements Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 87 S&F Towel Rack Stainless Steel With Suitable Fixing Arrangements Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 88 S&F Towel Rail Stainless Steel With Suitable Fixing Arrangements Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 89 S&F Towel Ring Stainless Steel With Suitable Fixing Arrangements Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 90 S&F Bib Cock With Flange 15 Mm Bore Stainless Steel With Suitable Fixing Arrangements Complete All As Specified And Directed ( Make-Kubix Prime Series - Jaquar / Equivalent In Kohler As Approved By Ge ) 91 S&F Granite 19 Mm Thick Of Any Type Work Table Rubbed And Polised In Steps, Jambs, Pillars, Window Cill, Cooking Plateforms And Like In Cement Mortar 1:4 Including Pointing Cement Mortar 1:2 Using Marble Dust With Admixure Of Pigments To Match With Shade Of Granite Complete All As Specified And Directed 92 S&F Rough Cast Wired Glass, 6.4 Mm Thick And Glazing With Oil Putty In Square Size Exc 0.50 Sqm But N Exc 0.75 Sqm With Solar Control Film 25 Micron Reflactive Type To Glass Panes As Per Instruction Manufacturer Complete All As Specified And Directed 93 S&F Sinks With Drainage Board Made Of Stainless Steel1.00Mm Thick Sheet For Kitchen With Plug Washerwaste Pipe, Mild Steel Bracketsconnecting Unionover All Size 915 X 460Mm With Bowl Size 410Mm X330mm X160mm But Fixed In Repair Incl Removing Existing Vitreous China Sink With Fittings Complete All As Specified And Directed 94 Supply And Fixing Newfrp Cable Tray Of Follwing Sizes Perforated Type For Laying Pvc / Xlpe Cable In Trecnch / At Wall / Under The Floor Including All Connecting Aceesories As Required Complete All As Specified And Directed ( A ) 100Mmx 50Mmx 3Mm Size 95 All As Per Item No. 94 Above Butsize 200Mmx 50Mmx 3Mm 96 M&L For Submain Wiring Alongwith Earth Continuity Conductor With Pvc Insulated Frls Multistranded Copper Conductor Cable ( Phase - Red, Neutral - Black, Earth - Green ) Drawing Into Andincluding Concealed Rigid Non Metallic Pvc Conduit, Medium Grade, Isi Marked Ivory Colour Along With Accessories Of Following Nominal Sizes:- ( A ) 2X4 Sqmm + 1X4 Sqmm Earth Wire In 20 Mm Dia Conduit. 97 ( B ) 2X6 Sqmm + 1X6 Sqmm Earth Wire In 25 Mm Dia Conduit. 98 ( B ) 2X10 Sqmm + 1X10 Sqmm Earth Wire In 50 Mm Dia Conduit. 99 ( A ) 4X4 Sqmm + 1X4 Sqmm Earth Wire In 50 Mm Dia Conduit. 100 ( B ) 4X6 Sqmm + 1X6 Sqmm Earth Wire In 50 Mm Dia Conduit. 101 ( B ) 4X10 Sqmm + 1X10 Sqmm Earth Wire In 50 Mm Dia Conduit. 102 Taking Down Carefully Sub Main Wiring With Pvc Casing Capping / Pvc Surface Conduit And Making Good Disturbed Surfaces Complete. 103 M& For Rewiring Of Buzzer System Of Cap Upto 12 Modulewith 1.5 Sqmm Including Cutting, Jointing As Required For Desired Logic Of Buzzer System Including Testing And Commissioning Ofelectric Circuitas Required 104 S&F In Repair 20 Amp, Single Pole And Neutral, Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top In Power Coated Crca Steel Sheet Enclosure Recess Mounted With Chained Metal Cover For The Socket Outlet With And Including One Number Single Pole C Series Mcb 16 Amp As Required. Make - Legrand Cat Ref No 507811 & 408592 Or Equivalent In Hager Or Schneider As Approved By Ge 105 S&F In Repair Mcb Distribution Board, Powder Coated, Crca Steel Sheet, Degree Of Protection Ip 43 - Ik 09 With Reversible Double Door, Recess Mounted, Having Insulated 100 Amp Tinned Copper Bus Bar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnection, Earthing Connection, Blanking Plates In Unused Spaces As Required With Following Ratings & Ways:-Spn, 240 Volts, 4 Ways. Make - Legrand Cat Ref No 507610 Or Equivalent In Schneider Or Hager As Approved By Ge 106 Spn, 240 Volts, 12 Ways. Make - Legrand Cat Ref No 507612 Or Equivalent In Schneider Or Hager As Approved. 107 Supply And Laying Cable Xlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cable ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Following Sizes : ( A ) 16Sqmm4 Core, 1.1 Kv 108 ( B ) 25 Sqmm4 Core, 1.1 Kv 109 M&L For Cable Jointing Kit For Upto 1.1 Kv ( Earthed ) Grade Cable For Indoorheat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3.5 Core Xlpe Armoured Aluminium Conductor Cable Of Following Size :- ( A ) 16 Sqmm 4 Core 110 ( B ) 25 Sqmm 4 Core 111 Supply And Fixing Mccb 125 Amp, 4 Pole, 16 Ka ( Ics=100% Icu ) Thermally Adjustable Between 70% To 100% With Spreader Links On Both Sides As Per Legrand Cat Ref No. 420016 Or Equivalent In Schneider Or Hager As Approved By Ge 112 Supply And Fixing Mccb 160 Amp, 4 Pole, 16 Ka ( Ics=100% Icu ) Thermally Adjustable Between 70% To 100% With Spreader Links On Both Sides As Per Legrand Cat Ref No. 420017 Or Equivalent Inschneider Or Hager As Approved By Ge 113 Supply And Fixingmccb 63 Amp, 4 Pole, Icu 16 Ka ( Ics=100% Icu ) , Electronic Release And Adjustable Between 40% To 100% With Spreader Links On Both Sides As Per Legrand Cat Ref No. 420013 Or Equivalent In Schneider Or Hager As Approved By Ge 114 M&L For Supplying, Installation, Testing & Commissioningoutdoorbus Bar Chamber Pedestal Type Suitable For 415V, 3 Phase, 4 Wire 50 Hz, Ac Supply Systemfabricated In Compartmentalized Design From Stainless Steel Sheet ( Ss 316 ) 2.0 Mm Thick Totally Enclosed, Dust, Weather & Vermin Proof Duly Painted And Consisting With Tpn Copper Bus Bars Of Rating 1.5 Times That Of Controlling Mccb Supported On F Class Smc Insulatorswith 4 Outgoing And One Mccb Tpn250 Amp, 25 Ka Rupturing Capacity And One 16 Amp Socket Test Point Controlled By Switchincluding Necessary Fixed In Pcc 1:3:6 Using 20 Mm Graded Stone Aggregate Including Danger Plate Etc Including Taking Down Old Complete All As Directed 115 M&L For Supplying, Installation, Testing & Commissioningoutdoorbus Bar Chamber Pedestal Type Suitable For 415V, 3 Phase, 4 Wire 50 Hz, Ac Supply Systemfabricated In Compartmentalized Design From Stainless Steel Sheet ( Ss 316 ) 2.0 Mm Thick Totally Enclosed, Dust, Weather & Vermin Proof Duly Painted And Consisting With Tpn Copper Bus Bars Of Rating 1.5 Times That Of Controlling Mccb Supported On F Class Smc Insulatorswith 4 Outgoing And One Mccb Tpn100 Amp, 25 Ka Rupturing Capacity And One 16 Amp Socket Test Point Controlled By Switch Including Necessary Fixed In Pcc 1:3:6 Using 20 Mm Graded Stone Aggregate Including Danger Plate Etc Including Taking Down Old Complete All As Directed 116 M&L For Pipe In Pipe Chemical Earthing With Gi Pipe Electrode 3.0 M Long Having Outer Pipe Dia 80 Mm & Inner Pipe Dia 50 Mm Duly Filled With Highly Conductive And Anti Corrosivecompound Of Required Quantity Having Chemical Composition Bentonite 40%, Copper Sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc Sulphate 10%, Aluminium Sulphate 10% Burried In Ground By Digging A Bore Of 150 Mm Dia Surrounded By Soil Friendly Backfill Compound Non Soluble In Water Including Connection With Galvanised Earth Strip 32 X 6 Mm, Making Pcc Pit Of Size 0.3 M X 0.3 M X 0.3 M ( Inner Size ) In Mix 1:3:6 Type C1 With Rcc 1:2:4Type B-1, 40 Mm Thick Cover Reinforced With 8 Mm Dia Ms Bars 3 Nos Both Ways With Lifting Hook Made Out Of 8 Mm Dia Bar And Testing On Completion To Achieve Value Not More Than 2.0 Ohm Complete. ( Note - Gi Strip Size 32X6 Mm Upto 7.5 M Included In The Item ) . 117 S&F In Repair Mcb Distribution Board, Tripple Pole And Neutral ( Vtpn ) Powder Coated Crca Steel Sheetsuitable For Mccb Incomer Upto 160 Amp, 4 Way, 415 Volts, Degree Of Protection Ip 43 - Ik- 09 With Reversible Double Door, Recess Mounted, Having 250 Amp Insulated Tinned Copper Bus Bar, Neutral Busbar, Earth Bar, Din Bar, Detachable Gland Plate, Interconnection, Earthing Connection, Blanking Plates In Unused Spaces As Required. Make- Legrand Cat Ref No 507745 Or Equivalent In Schneider Or Hager As Approved By Ge. Note For Mcbs & Mcb Dbs:- Mccbs, Mcbs & Mcb Dbs Shall Be Of The Same Make. 118 S&F Mcbs OfC Series Having Breaking Capacity 10 Ka, Isi Marked Including Required Wiring Connections With Copper Lugs Of Suitable Size Provided In Mcb Dbs Of Following Ratings:- ( A ) Single Pole 6 To 32 Amp. Make - Legrand Cat Ref No 408587 To 408595 Or Equivalent In Schneider Or Hager As Approved By Ge 119 ( B ) Doublepole 10 To 32 Amp. Make - Legrand Cat Ref No 408631 To 408636 Or Equivalent In Schneider Or Hager As Approved By Ge 120 ( C ) Doublepole, 40 To 63 Amp. Make - Legrand Cat Ref No 408637 To 408639 Or Equivalent In Schneider Or Hager As Approved By Ge 121 ( D ) Four Pole 40 To 63 Amp. Make - Legrand Cat Ref No 408700 To 408702 Or Equivalent In Schneider Or Hager As Approved By Ge 122 M&L For Brick Work With Sub-Class B Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Thick Walls Built In Cement Mortar 1:4 And Plastering 10 Mm Thick In Cm 1:4 And 2 Coats Of White / Colour Washing To Match The Surface Complete. 123 S& F In Repair Integral Led Flood Light 50 W 3000 K ( Ww ) Warm Whitewith Driver Inside A Pdc Housingphilips Cat Part Nocvp 182 Led 50 W Cw Fg S1 Psu Gr Or Equivalent To Havells / Cg As Approved By Ge. 124 S& F In Repair Integral Led Flood Light 20 W 3000 K ( Ww ) Warm Whitewith Driver Inside A Pdc Housingphilips / Havells / Cg As Approved By Ge. 125 S& F In Repair Integral Led Fountainlight 50 W 3000 K ( Ww ) Warm Whitewith Driver Inside A Pdc Housingphilips Psu Gr Or Equivalent To Havells / Cgas Approved By Ge. 126 Supply And Fixingin Repair Led Based Bollard 10 Wattwith Ms Pipe Housing With Glare Free Pmha Difuser, Ip 65 Hight Of Light 1 Mtr Includingmortar Base And Connetion Wire Of Suitabe Size Complete All As Directed. 127 M&L For Taking Out Pressure Pump Of Any Capacity Upto 2 Hp & Any Make From Foundation Including Cutting / Dismantling And Fixing At New Location In Pcc Including Jointing / Connecting Electrical Connection Or As Directed. 128 Supply And Fixing Cover Shed For Pressure Pump Set1 Mtr X 0.75 Mtr Including Pcc For Pole For Fixing In Foundation Or All As Specififedand Directed. 129 Supply And Fixing In Repairled Bulb 12 Watt Warm White Complete All As Directed. 130 S&F In Repair Recess Mounted Led Panel Of Round Shaped, Cap 12 W, Long Life 25000 Burning Hours Including Making Connection Complete All As Directed. 131 Supply And Fixing Of 1100 Volts Grade Heavy Duty Cable Pvc Insulated Copper Conductor And Over All Sheathed In Service Connection Including Fixing In Wall As Reqiredwith Twin Core Cables Stranded Conductor Of Size 4 Sqmm Complete All As Directed. 132 All As Per Item No 120.01 But Size 6 Sqmm 133 All As Per Item No 120.01 But Size 10 Sqmm 134 Supplying And Fixing Energy Efficient Recessed Mounted Led Luminaire Suitable For 2X2 Grid Ceiling With Flat Diffuser And Lumen Output Of 3300 Lumens Having Constant Current Electronic Driver Duly Connected With 0.5 Sqmm White Colour Pvc Insulated & Sheathed Three Core Flexible Multi Stranded Copper Conductor Cable As Required. 135 M&L For Taking Old Serviceable Pvc / Xlpe Cable Any Size Any Makefrom Wall / Trench / Floor And Relaying Same To New Loaction / Cable Trench / Floor / Wall Including Jointing Connecting Complete All As Directed 136 M&L For Point Wiring With 1100 Volts Grade Pvc Insulated Frls Multistranded Copper Conductor Cable 1.5 Sqmm ( Phase-Red, Neutral-Black ) And Earth Continuity Conductor 1.5 Sqmm ( Green ) Drawn Into And Including Concealed Rigid Non Metallic Pvc Condiut Medium Grade Not Less Than 20Mmdia Isi Marked Ivory Colour With All Conduit Fittings / Fixing Accessories And Unwelded Sunken Galvanised Pressed Steel Terminal Boxes Of Thickness Not Less Than 1.0 Mm Or Mounting Modular Cover Plate & Frame For Mounting Switches, Scokets, Fan Regulators As Required For One Light Point Controlled By One Switch Including Taking Down Of Old Complete All As Directed 137 All As Per Item No. 123 Here-In-Before But One Fan Point Controlled By One Switch. 138 All As Per Item No. 123 Here-In-Before But One Socket Outlet 6 Amp Controlled By One Switch On The Same Board With Other Switches. 139 All As Per Item No. 123 Here-In-Before But One Socket Outlet 6 Amp Controlled By One Switch On Indepdendent Board. 140 M&L For Point Wiring With 1100 Volts Grade Pvc Insulated Frls Multistranded Copper Conductor Cable 4.0Sqmm ( Phase - Red, Neutral - Black ) And Earth Continuity Conductor 4.0 Sqmm ( Green ) Drawninto Existing Concealed Conduit Andterminated In And Including Modular Metal Flush Boxes For Mounting Modular Cover Plate & Frame For One Socket Point 16 Amps Controlled By One Switchincluding Taking Down Of Old Complete All As Directed 141 S&Fmodular Switch One Way 6 Amp 1 Module All As Per Legrand Britzy Cat Ref No. 673401 Or Equivalent As Approved By Ge. 142 Supplying And Fixingmodular Socket6 - 2 / 3 Pin Combined 2 Moduleall As Per Legrand Mylinc Cat Ref No. 675555 Or Equivalent As Approved By Ge. 143 Supplying And Fixing Modular Switch One Way 16 Amp 1 Module All As Per Legrand Mylinc Cat Ref No. 675511 Or Equivalent As Approved By Ge. 144 S&F Modular Socket 6 / 16 Amps, 2 / 3Pin Combined 2 Module Ac 230 Volts. 145 S&F Modular Fan Regulator 120 Watts, 2-Module Ac 230 Volts. 146 M&L For Replacement Of Copper Tubes Of Size 1 / 4 And 3 / 8 Suitable For Any Type And Capacity Air Conditioner Complete All As Specified And Directed. 147 M&L For Replacement Of Pvc Insulated Sheathed Flexible Round, 3 Core Cable With Copper Conductor Of Size 80 / 0.20 For Ac Complete All As Specified And Directed. 148 M&L For Replacement Of Sheet Metal Enclosure, Single Pole & Neutral With Two Pin & Earth Plug And Socket With One Mcb Single Pole 20 Amp, 240 Volts Complete. 149 M&L For Replacement Of Damaged Insulation Of Size 1 / 4&3 / 8, 1 / 2&5 / 8For Split Ac Complete As Per Existing Site Complete All As Specified And Directed. 150 M&L For Replacement Of Voltage Stabilizer 04 Kva To 5 Kva, Input Voltage Range 90 Volt To 220 Volt And Output Voltage 220 Volt To 230 Volt Ac + 2% Variationof Voltage Complete With Accessories Etc Complete All As Specified And Directed. 151 M&L In Repair Mounting Frame / Stand Suitable For Outdoor Unit Of Split Ac Of Any Size All As Specified And Directed. 152 Schedule Of Credit

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 09-01-2023 Amendment BOQ 21-01-2023
2 21-01-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 82000.0 /-
Tender Value
INR 41 Lakhs /-