Tender For Modification Of Existing Hanger In Flight Lab To Accommodate The Proposed Prototyping Facility ( Sh: Electrical Work ) - Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gl Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 2 Group C 3 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Erls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Erls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 4 Group C 5 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 6 3 X 1.5 Sq. Mm 7 3 X 2.5 Sq. Mm 8 6 X 10 Sq.Mm. 9 6 X 16 Sq.Mm. 10 Supply And Fixing Of 32 X 20 Mm Dlp Mini- Trunkingwhite-System With Independent Coveretc. As Required Complete. 11 Supply And Fixing Of Following Accessories Suitable For 32 Mm X 20 Mm Sizeplastic Trunking White System. 12 Internal / External Angle 13 Changeable Flat Angle 14 Supply And Fixing Of 105 X 50 Mm Dlptrunkingwhite-System But Without Cover And Partition Etc. As Required Complete. 15 Supply And Fixing Of Following Accessories Suitable For 105 Mm X 50 Mm Sizeplastic Trunking White System. 16 85 Mm Flexible Cover 17 End Cap 18 Internal Angles- Adjustable From 80°-100° 19 External Angles- Adjustable From 60°-120° 20 Flat Junction 21 Flat Angles 22 Separation Partitions 23 Joints For 85Mm Width Cover 24 Base Joints 25 S & F Following Size Of Steel Flexible Pipe Along With The Accessories On Surface Etc As Required 26 20 Mm 27 25 Mm 28 Supplying, Installation Of Clip-On Frame With Finishing Plate For 85Mm Cover For Dlp Plastic Trunking 105Mm X 50Mmetc. As Reqd. 29 6 Module 30 Supplying And Fixing Following Modular Switch / Socket On The Existing Clip-On Frame Fixed On 85Mm Cover Of 105 X 50 Mm Dlp Plastic Trunking Including Connections Etc. As Required Complete. 31 6 A Switch 32 20 A Switch 33 6 A Pin 2 / 3 Pin Socket Outlet 34 6 / 16 A 3 Pin Socket Outlet 35 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Lsolator ) 36 12 Way, Double Door 37 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 38 12 Way ( 4 + 36 ) , Double Door 39 Supplying And Fixing Following Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Single Pole 5 A To 32 A 41 Triple Pole 5 A To 32 A 42 Single Pole ( 40A-63A ) 43 Double Pole ( 40A-63A ) 44 Triple Pole ( 40A-63A ) 45 Four Pole ( 40A-63A ) 46 S & F Metal Enclosure Suitable For Dp / Tpnmcb / Dp Elcb On Surface Or Recessed Etc As Reqd. 47 Supply And Fixing Of Following Led Light Fixture With Efficiency >100 Lumen / Watt, P.F. >0.95, Thd<10%, Electronic Driver, Led Lamp, Reflector, Diffuser, Ms Body / Housing Holder Etc. Complete With All Fixing Accessories And Lamp As Required Complete. 48 36 Watt Recess Mounting Led Light Fixture 600 X 600 Mm 49 36 Watt Surface Mounting Led Light Fixture 300 X 1200 Mm 50 Fixing Of Rj-45 Modular Box With Cover Plate Or I / O Box For Interneton Surface / Recessed Cutting The Wall Making Good The Same As Required. ( Box And Cover Plate Will Be Supplied By Dept. ) 51 Laying Utp Cable Enhanced Cat 5 / Cat 6 Cable In Existing Steel Conduit Pipe / Gi Pipe / Raceway / Rcc Pipe As Reqd. The Cost Shall Also Include Numbering Of Networking Wire From Room To Rack As Reqd. ( Wire Will Be Supplied By Dept ) 52 Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 53 Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. 54 Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.L. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 55 Supply And Installation Of 400Mm Sweep Ac 230 / 250 Volts, 50 Hz Wall Mounting Revolving Fan With Brackets Etc Complete. 56 Supplying And Fixing Exhaust Fan Shutter For Following Sizes Exhaust Fan On Rag Bolts As Reqd Complete. 57 For 450 Mm / 18 Sweep 58 Supply, Installation Testing And Commissioning Of Following Seep, Copper Wound, 900 Rpm, 220 Volt Ac, 50 Hz Exhaust Fan In The Existing Openingetc As Required Complete. 59 450 Mm / 18 Sweep 60 S&F, Copper Tube / Reducer / Lugterminals Suitable For Following Size Of Conductor. 61 6 / 10 / 16 Sq.Mm. 62 Supplying Of One No. 3.5 X300.0 Sqmm Pvc Insulated, Xlpe Steel Armoured Aluminium Conductor Power Cable Of Grade 1.1 Kvas Required Complete In Following Manners. 63 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. 64 Above 185 Sq. Mm And Upto 400 Sq. Mm 65 Laying Of One Number Additional Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. 66 Above 185 Sq. Mm And Upto 400 Sq. Mm 67 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. 68 Above 185 Sq. Mm And Upto 400 Sq. Mm 69 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. 70 Above 185 Sq. Mm And Upto 400 Sq. Mm 71 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 72 3½ X 300 Sq. Mm ( 70Mm ) 73 Providing, Laying And Fixing Following Dia G.L. Pipe ( Medium Class ) In Ground Complete With G.L. Fittings Including Trenching ( 75 Cm Deep ) And Re-Filling Etc As Required 74 100 Mm Dia 75 Supplying And Fixing 63 Amps, 415 Volts, 3P+N+E Industrial Type, Socket Outlet, With 5 Pin Metal Enclosed Plug Top Along With 63 Amps C Series Four Pole Mcb, In The Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket As Required Complete. 76 Supplying & Fixingconnecting , Testing & Commissioning, Of Cubical Type Lt Panel Suitable For 440V, 3 Phase, 4 Wire 50 Hz Ac Supply System Fabricated In Compartmentalized ( Preferable ) Design From Crca Sheet Steel Of 2 Mm Thick For Frame Work And Covers. 3 Mm Thickgland Plate I / C Cleaning & Finishing Complete With Process For Powder Coating In Approved Shade, Having Suitable Capacity Extensible Type Fp Aluminium Alloy Bus Bars Of High Conductivity. Dmc.Smc Bus Bar Supports. Bottom Base Channel Of Ms Section Not Less Than 100Mm X 50M X 5Mm Thick, Fabrication Shall Be Done In Transportable Sections, Entire Panel Shall Have A Common Earth Bar Of Suitable Size At The Rear With 2 Nos Earth Solid Connections From Main Bus Bar To Switch Gears With Required 1.5 Sq.Mm. Zero Halogen Fire Retardant Low Smoke Insulated Copper Conductor S / C Cable, Cable Alleys, Cable Gland Plate In Two Half. 77 Incomer 78 400 Amp 35 Ka Fp Mccb 79 Out Goings 80 A- 100 A Tpn, 35 Ka-, Mccb - 4 Nos.B- 125 A, Tpn, 35 Ka, Mccb -2 Nos. C-160 A, Tpn, 35 Ka Mccb -1Nos. Note: Incomer Should Have Ryb, On-Off Indication Multifunction Meter With A, V, Pf, Kw, Kvah, Kwah Function And Microprocessor Based Release For Lsig Protection, Rotary Handle. All Out Goings Should Have On-Off Indication Adjustable Thermal Magnetic Release For Lsi Protection., Rotary Handle Etc.