Sub: Invitation Of Tender For Supply Of Equipment’S And Material At Various Department Through E Procurement Portal.-1 Rockwell cum Brinell Hardness Testers- Facility for Brinell and Rockwell tests with standard accessories and set of specimens. Fully automatic digital type, Load up to 250 kg. , Rockwell Scale- A, B, C , Hardness Resolution - 1.0 of a Rockwell Unit 2 Digital impact testing machine- Facility for Charpy and Izod tests, fully automatic digital type, along with standard accessories. Pendulum Drop Angle - 140 °C for Charpy Test and 87 °C for Izod Test, Distance of axis of hammer rotation and center - 825 mm 3 Bernoullis Theorem Apparatus- Supply & receiving chambers of 0.2 m. x 0.2 m. x 0.7 m. height with gauge glass & scale fittings for the measurement of total potential head, & interlinking duct made of thick transparent perspex sheet smooth variable cross section, quality transparent piezometer tubes to measure the pressure head along the duct, & a flow control valve. M.S. reservoir of size 0.9 m length x 0.55 m width x 0.45 m height, drain valve of 1⁄2 ” size & a bend. M.S. collecting as well as measuring tank of size 0.6 m length x 0.35 m width x 0.45 m height & drain valve of 1” size. A gauge glass & scale fitting are fitted on measuring tank for discharge measurement.1⁄2 HP high head monoblock pump for water circulation. Entire unit is powder coated with good colour combination 4 Venturemeter & Orificemeter Apparatus- Venturimeter 1” size having 13 mm throat diameter with 2 G.M. valves. Orificemeter suitable for 1” size pipe line &M.S. reservoir of size 0.4 m (w) length x 0.35m (h) width x 0.8 m (L) height. d/D ratio is 0.6 with 2 G.M. valves. M.S. collecting as well as measuring tank of size 0.5 m length x 0.35 m width x 0.35 m height drain valve of 1” size. A gauge glass 0.4 m height double column differential manometer. (without Mercury) & scale fitting are fitted on measuring tank for discharge measurement.1⁄2 HP high head monoblock pump for water circulation. Entire unit is powder coated with good colour combination. 5 Digital manometer - 0 to 400 mm of Hg 6 Point Load Index Tester (Digital)- Ref. Standard - IS:8764 Range : 0 to 50 kN Maximum Specimen Size : 80 mm Maximum Pressure : 70 MPa Operating Temperature:: -10 to +50 ℃ 7 Universal Automatic Compactor- Universal Automatic Compactor, IS : 2720 (P-vii & viii), IS : 10074-82 Motorized for 100 & 150 mm moulds. Two sets of rammer 2.6 kg x 310 mm drop & 4.89 kg x 450 mm drop as per ISS/ BSS. One CBR Mould with collar & perforated base plate. l/5th revolution per stroke of rotating base plate with Automatic blow counter. 230V, 1 Phase, 50 cycles, A.C. supply. 8 Soil Cone Penetrometer :Digital- Cone Penetrometer. Complete with Stainless Steel Test Cone. Digital Ref. Standards IS:2720 (Part 5) BS 1377 : digital penetration measurement gauge 0.01 mm precision, release button and automatic zeroing. Bench mounted apparatus to determine the liquid limit of soils BS1377. 30deg, 30mm long test cone. Manufactured from stainless steel and includes adjustable levelling feet. Electronic Timer Unit Penetration Range : up to 50 mm The unit is protected with an anti-surge fuse and is powered from electrical supply 9 Infra-Red Moisture Meter- Infra-Red Moisture Meter :Ref. Standard: IS:2720 (Part 2) Moisture Range : 0% to 100% Measuring Accuracy of Moisture : 0.5% Amount of Samples ≥ 0.5 g Weight of Measurement Samples : 0.5g - 60g 10 Digital Heating block (COD Digester)- Bores: 2 x 12 with 16 mm outer diameter Display Colored, backlit LCD touch screen Operation: Icon-based menu guidance via touch screen Temperature range: 40–160 °C (1 °C increments) Warm up time: From 20 °C to 160 °C within 10 minutes Time range: 0 h 01 min–9 h 59 min (increments 0 h 01 min),Temperature stability: ±1 °C , Interfaces: Bidirectional serial RS232, USB A (function) and USB B (Host), Operating range: 10–40 °C, max. 80 % relative humidity (non-condensing), Power supply: 110–230 V AC, 50 / 60 Hz, Power consumption: 300 / 550 W, Dimensions: 290 x 287 x 146 mm, Weight: 3.2 kg, Power cable, manual, data cable, software CD 11 Probes of HACH make for pH, and Conductivity- HACH-pH C201 Accuracy: ±0.02 pH , Application: Clean Samples Cable Length:1 m (3.28 ft), Electrode Type: Non-Refillable Gel Reference Element, semi-liquid gel Junction: Porous Pin Junction, Length: 175 mm (6.89 in.), Method Type: Laboratory: Non-Refillable Gel Reference Element, semi-liquid gel Parameter: pH, Probe, Type: Standard, Product Kit: Model: PHC201, Range: 0 - 14 pH, Reference Type: Ag/AgCl (double junction), Resolution: 0.001/0.01/0.1, Sample depth: 15 mm (0.59 in.) Sensor material: Epoxy, Sensor Type: pH Glass, Sodium (Alkalinity) error: <20% at pH 14 in 1 M NaCl Special Features: General purpose. Clean water samples. Temperature Accuracy: ±0.3 °C (±0.54 °F) Temperature Range:0 - 80 °C (32 - 176 °F), Temperature Resolution:0.1 °C (0.18 °F) Test requirements: Parameter ,Needed: pH, Minimum Sample Depth (mm): 15, Thermistor: ATC, Weight: 0.1 kg HACH-CDC40103 Accuracy: Cond: ±0.5% of reading, Salinity: ±0.1, ±1 digit, TDS: ±0.5% ±1 digit, Cable Length:3 m (9.84 ft), Electrode Type: Conductivity Cell; 4 Poles - Graphite, Length: 184 mm (7.24 in.), Method Type: Field: 4 Poles – Graphite, Parameter: Conductivity , Probe Type: Standard, Product Kit: Model: CDC401,Range: Conductivity: 0.0 μS/cm - 200 mS/cm,