Tender For Certain Misc B / R And E / M Repair To Md Accn Under Ge Narangi - Excavation In Trenches, N.Exc 1.5 M Wide And N.Exc 1.5 M In Depth For Laying Of Cable , Etc. N.Exc 10 Sqm On Planand Getting Out In Soft / Loose Soil Complete All As Specified And As Directed. 2 Returning Filling In Including Spreading, Levelling Watering And Well Ramming In Layers Not Exc 25 Cm Thickin Soft / Loose Soil Complete All As Specified And As Directed. 3 Removing Surplus Soil To A Distance Not Exc 50M And Depositing At Level Not Exc 1.5M Above The Starting Point Complete All As Specified And As Directed. 4 Dismantling Of Plain Or Corrugated Steel Sheeting, Any Gauge Or Any Thickness As In Roof Covering, Wall Cladding Etc., Completeall As Specified And As Directed. 5 S&F 0.63 Mm Thick Galvanised Corrugated Mild Steel Sheeting With Two Corrugation Side Lap, Fixed With L Type Or J Type Or Cranked Hook Bolts And Washers, In Roof Covering, Walls Cladding Etc, With Grade Of Zinc Coating 275 Complete All As Specified And As Directed. 6 Refixing Only Galvanised Corrugated Mildsteel Sheeting As Obtained From Dismantling Of Old Sheets Here In Before With Two Corrugation Side Lap, Fixed With & Including L Type Or J Type Or Cranked Hook Boltsin Roof Covering, Wall Cladding Etc., Complete All As Specified And As Directed. 7 S&F 0.63 Mm Thick Plain, Galvanised, Mild Steel Sheeting, In Ridges, Hips, Valley Gutters, Drip And Straight Flashings ( Length And Girth As Fixed ) With Grade Of Zinc Coating 275 Complete All As Specified And As Directed. 8 M&L For Pcc 1:3:6 Type C-1 ( Using 20 Mm Graded Stone Aggregate ) As In Fixing Of Hold Fast Or Bed Block Complete All As Specified And Directed. 9 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For Complete All As Specified And As Directed. 10 S&F For Framed Work Such As Grills, Gratings Etc., With Ends Of Bars Shouldered And / Or Riveted, Or Forget Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Frame Work Of Water Tanks And Similar Work Conforming To Fe 290, Gde-E-165 Completed All As Specified And Directed. 11 S&F In Repairs, Suspended False Ceiling Using E-Grid 2430, 180 Gsm ( Exposed Ceiling Suspension System ) Of Grid Size 600Mmx600 Mm With Main Runner 38 Mm X 24 Mm And Wall Angle 24Mm X 24Mm Using 4Mm Thick High Pressure Stean Crude Everest Non Asbestos Fiber Cement Plain Board ( E-Board Classic ) In & Including A Grid Of Gi System Duly Suspended With 4Mmdia Gi Wire Hanger Fixed With Steel Dash Fasteners Or Iron Purlin From The Roof With Adjustment Clip Providing Positions For Light Fixtures, Air Conditioning Diffuser And Ducts , Sprinkler , Smoke Detectors Etc.The Main Runners To Be Secured To Structural Soffits By Hanger @ 1220 Mm Maximum C / C. The Last Hanger At The End Of Each Main Runner Should Not Be Placed At More Than 450Mm From The Adjucent Wall, Flush Fitting 1220 Mm Cross Tee To Be Interlocked Between Main Runners @ 610Mm C / C, So As To Form 600Mm X 600 Mm Grid Complete All As Specified And As Directed. 12 Demolition Ofplain Cement Concrete In Ground Floors And Pavings Not Exceeding 15 Cm Thickness ( Below Or Above Ground Level ) Complete All As Specified And As Directed. 13 Demolition Of Cement Concrete ( Unreinforced ) Of Any Descriptionand In Any Position Not Otherwise Specifically Provided Forcomplete All As Specified And Directed. 14 M & L For 75Mm Thick Pcc 1:3:6, Type C2 ( Using 40Mm Graded Stone Aggregate ) As In Plinth Protection, Etc Finished The Surface Even And Smoothwithout Using Extra Cement Including Provision Of Joint Of Size 10 Mm Wide & 10 Mm Deep And Filling With Bitumen Mastic Jointfilling At Every 3M Length And At Corners Complete All As Specified And As Directed. 15 M&L For 25Mm Thick Pcc 1:2:4, Type B1 ( Using 20Mm Graded Stone Aggregate ) As In Floorfinished The Surface Even And Smooth Without Using Extra Cementcomplete All As Specified And As Directed. 16 M&L For50mm Thick Pcc 1:3:6, Type C-2 ( Using 40Mm Graded Stone Aggregate ) As In Sub Base Complete All As Specified And As Directed. 17 M&L For Pcc 1:3:6 Type C-0 ( Using 12.5Mm Graded Stone Aggregate ) As In Back Filling Of Pressed Steel Door / Window Frame Complete All As Specified And Directed. 18 M&L For Pcc 1:5:10 Type E-2 ( Using 40Mm Graded Stone Aggregate ) As In Filling Of Sunken Floors Complete All As Specified And Directed. 19 Demolition Of Brick Work Built In Cement Mortar Including All Quoins, Arches, Pillar Including Coping Etc. Complete All As Specified And As Directed. 20 M&L For Brick Work With Sub Class ‘B’ Bricks ( Locally Available Best Quality ) Straight Or Curved On Plan Exceeding 6M Mean Radius, Built In Cement Mortar 1:6 Complete All As Specified And As Directed. 21 All As Per Item No.20 Above But Except Bricks. ( Serviceable Bricks Shall Be Obtained From Demolition Of Old Brick Work ) Complete All As Specified And As Directed. 22 M&L For Brick Work With Sub Class ‘B’ Bricks, ( Locally Available Best Quality ) Straight Or Curved On Plan To Any Radius In Half Brick Thick Wall, Built In Cement Mortar 1:4 Complete All As Specified And As Directed. 23 Taking Down Cement Plaster On Walls, Chajja Surfaces, Etc Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc Complete All As Specified And As Directed. 24 M & L For Rendering 10 Mm Thick In Cement Mortar ( 1:6 ) On Fair Faces Of Brick Work Or Concrete Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed 25 M&L For 15Mm Thick Rendering In Cement Mortar ( 1:4 ) , In Two Layers, Under Coat Of 10 Mm Thick & Top Of 5 Mm Thick, To Other Than Fair Faces Of Brick Or Concrete Wall Surfaces, Top Layer 5 Mm Thickmixed With Water Proofing Compound ( @ 2% By Weight Of Cement Or As Per ManufactureS Instructions ) , Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. Note :Water Proofing Compoundwill Be Measured And Paid Separately As Supply Only. 26 M&L For Rendering 5Mm Thick In Cement Mortar ( 1:3 ) On Fair Faces Of Rcc Concrete Surfaces And Including Applying Cement Slurry In Bottom Of Slab, Chajjas, Fin, Facias Etc. Complete All As Specified And As Directed. 27 M&L For Rendering 10Mm Thick Bedding Layer In Cement Mortar ( 1:4 ) Onroof Top, Sunken Floor Surfaces In Single Layer Mixed With Wpc @ 2% By Weight Of Cement For Laying Floor Finish Etc. Complete All As Specified And As Directed. ( Note: Wpc Shall Be Measured And Paid Seperately Under Relevent Item As Supply Only ) . 28 M&Lapplying Two Coats @ 1.50Kg Per Square Metre Per Coat Minimum Of Two Componenets Ofwater Proofing Treatmenton Rccroof / Wall / Sunken Surfaces Or Plastered Surfaces With Nito Proof 100 As Priming Coat And Nito Proof 120 Or 100 As Finishing Coat Of Forsoc Or Equivalent Approved Make 29 Supply Only Integral Water Proofing Compound Complete All As Specified And As Directed. 30 M&L For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coat Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And As Directed. 31 M&L For Preparation Of Newly Plastered Surfaces Of Ceiling And Applying Three Coats Of White Wash Complete All As Specified And Directed. 32 M&Lfor Preparetion Of New Plastered Surfacesof Walland Applying Two Coat Ofoil Bound Distemper Over A Coat Of Primercomplete All As Specified And Directed . 33 M&Lfor Complete Removal Of Existing Treatment Of Wall Surfaces, Applying Two Coat Ofoil Bound Distemper Over A Coat Of Primer Including 1Mm Thick ( Average ) Thick Wall Care Putty Sanding The Surface Till Smooth Finish Is Obtained Complete All As Specified And Directed . 34 M & Lfor Preparing New Surfaces Of Wood And Wood Based Materials Of Any Description Exceeding 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint ( Ordinary Tint ) Over A Coat Of Pink Primer Complete All As Specified And Directed. 35 M&L Preparation Of New Or Previously Untreated Surface Of Steeland Iron Work Of Any Description, Not Otherwise Described, Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint ( Ordinary Tint ) Over A Coat Of Red Oxide Primer Complete All As Specified & As Directed. 36 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frame ) Area N.Exc. 1.5 Sqm Each Including Builders Hardwarecomplete All As Specified And As Directed. 37 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frame ) Area Exceeding 1.5 Sqm But Not Exceeding 4 Sqm Each Including Builders Hardware Complete All As Specified And As Directed. 38 Taking Down Chowkats Or Framesarea Exceeding 1.5 Sqm But Not Exceeding 4 Sqm Each Including Builders Hardware Complete All As Specified And As Directed. 39 Taking Down Shutter Of Any Descriptionarea N.Exc 1 Sqmeachincluding Builders Hardware Complete All As Specified And As Directed. 40 Taking Down Shutter Of Any Descriptionexc 1 Sqm But N Exc 2 Sqm Each Includingbuilders Hardware Complete All As Specified Anddirected. 41 Taking Down Shutter Of Any Descriptionexc 1 Sqm But N Exc 2 Sqm Each And Refixing In Same Openingcomplete All As Specified Anddirected. 42 M&L For 2Nd Class Hard Wood Plain, Solid, Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered Put Together With Glue Pinnedat Joints Complete All As Specified And Directed. 43 M&L For 1.25Mm Thick Factory Made Pressed Steel Frames Of Size 105X60mm For Doors With Single Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc Complete All As Specified And Directed. 44 M&L For 1.25Mm Thick Factory Made Pressed Steel Frames Of Size 125X60mm For Doors With Single Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc Complete All As Specified And Directed. 45 S&F 30Mm Thick Flush Shutter, Solid Core Construction With Block Board Core And Plywood Face Panel, Commercial Type On Both Side Complete All As Specified And Directed. 46 S&F 30Mm Thick Second Class Hard Wood Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauge Etcwith Plain, Chamfered Or Rounded, Mitred Beads ( With Sash Bars ) For Securing Glass Etc, Sizes Of Members Of Shutters All As Specified In Ssr Part-I Section 8 Clause 8.24 ( B ) Complete All As Specified And Directed. 47 S&F 35Mm Thick Second Class Hard Wood Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauge Etcwith Plain, Chamfered Or Rounded, Mitred Beads ( Without Sash Bars ) For Securing Glass Etc, Sizes Of Members Of Shutters All As Specified In Ssr Part-I Section 8 Clause 8.24 ( A ) Complete All As Specified Anddirected. 48 S&F Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30Mm Thickcomprising Of Virgin Pvc Polymer Of K Value 58-60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibres ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Having Minimum Density Of 650Kg / Cum, Screw Withdrawl Strength Of 1800N ( Face ) And 900N ( Edge ) , Minimum Compressive Strength Of 50N / Sqmmmodules Of Elasticity 850N / Sqmm And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardent And Fixed With Ss Butt Hinge Of Required Sizewith Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws. ( Ssbuttt Hinge And Necessary Ss Screws Shall Be Measured And Paid Seperately ) . 49 S&F Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 18Mm Thickcomprising Of Virgin Pvc Polymer Of K Value 58-60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibres ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Having Minimum Density Of 650Kg / Cum, Screw Withdrawl Strength Of 1800N ( Face ) And 900N ( Edge ) , Minimum Compressive Strength Of 50N / Sqmmmodules Of Elasticity 850N / Sqmm And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardent And Fixed With Ss Butt Hinge Of Required Sizewith Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws. ( Ssbuttt Hinge And Necessary Ss Screws Shall Be Measured And Paid Seperately ) . 50 S&F Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door / Window / Ceosetory Windows And Other Frames / Chowkats Of Size 50X100mm Comprising Of Virgin Pvc Polymer Of K Value 58-60 ( Suspension Grade ) , Calcium Carbonate And Natural Fibres ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives ( Maximum Toxicity Index Of 12 For 100 Gms ) Febricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Fulll Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg / Cum, Screw Withdrawl Strength Of 2200N ( Face ) And 1100N ( Edge ) , Minimum Compressive Strength Of 58N / Sqmmmodules Of Elasticity 900N / Sqmm And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof, Water / Moisture Proof And Fire Retardent And Fixed In Position With Ms Hold Fast / Lugs / Ss Desh Fasteners Of Required Dia And Length. ( Ms Hold Fast / Lugs Or Ss Dash Fastener Shall Be Measured And Paid Seperately ) Note : For Wpc Solid Door / Window Frame Plus Minus 5Mm Tolerance In Dimension I.E Depth And Width Of Profile Shall Be Acceptable Complete All As Specified And Directed. 51 S&F Factory Made Solid Pvc Door Frame Of Size50 Mm X 47 Mm Made Out Of 5 Mm Plain Colour Pvc Sheet Reinforced With Mild Steel Square Tube Complete All As Specified And Directed. 52 S&F Factory Made Solid Panel Pvc Door Shutter 30Mm Thick ( Style ) Consisting Of Frame Made Out Of Ms Tube For Top And Bottom Rails, Ms Frames Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C’ Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stills And Plain Colour Pvc Sheet Top Rail, Lock Rail And Bottom Rail On Either Side And As Gap Insert For Top Rail And Bottom Rail, Paneling Of Plain Colour Pvc Sheet To Be Fitted In The Ms Frame Welded / Scaled To The Stiles And Rails With Suitable Pvc Sheet Beading And Jointed Together With Solvent Cement As Per Drawings And Specifications As Catered In Ssr Part – Ii 2004 Complete All As Specified And Directed. 53 S&F In Repair 18 / 19Mm Thick Block Boardsgrade 2 Quality Interior Grade Commercial Type Fixed With Screws To Timber Frame Work As In Cup Boards And Shelvescomplete All As Specified And Directed. 54 S&F Steel Window With Side Hung Shutterglazed Shutter Ibncluding Both Side Openable ( Outsude Glazed Window And Inside Fly Proof Window ) Including Box Type Hinges With Steel Handle And Steel Peg Stay Complete With Glazing Bars And 12 Mm Square Bar Or Round Bar Of Approved Design Welded To Steel Window Frame Dovetailed Or Welded Complete All As Specified And Directed. ( Guard Bar Or Square Bar Shall Be Measured And Paid Seperately ) . 55 S&F Steel Ventilators With Top Hung Shutters Includinghinges , Steel Peg Stay Complete All As Specified & As Directed . 56 S&F Stainless Steel Butt Hinges 100 Mm Long Complete All As Specified And As Directed. 57 S&F Stainless Steel Butt Hinges 75 Mm Long Complete All As Specified And As Directed. 58 S&F 100Mm Long Aluminium Anodised Barrel Tower Bolts Of Extruded Section Complete All As Specified And Directed. 59 S&F 150Mm Long Aluminium Anodised Barrel Tower Bolts Of Extruded Section Complete All As Specified And Directed. 60 S&F 150Mmsize Extrudedaluminium Handles, Cast Type, Anodised Complete All As Specified And Directed. 61 S&F 100 Mm Size Aluminium Alloyhandles, Cast Type, Anodised Complete All As Specified And As Directed. 62 S&F Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolt Of Extruded Section Or Cast Aluminium Alloy And Fixed 300Mm Long Complete All As Specified And Directed 63 S&Fin Repair Steel Helical Door Spring 300Mm Ordinary Rat Tail Rod Pattern Springs Includingroller And Roller Plate Complete All As Specified And As Directed. 64 S&Fin Repairharrison Rails Mild Steel Chromium Plated With Fixing Brackets, Stops, Rollers Etc. Complete All As Specified And As Directed. 65 S&Fin Repairpowder Coated Bracket For 25Mm Dia Curtain Rod Omplete All As Specified And As Directed. 66 S&F Stain-Less Steel Wire Cloth, 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40 Mm And Fixed With Stainless Wire Staples Complete All As Specified And As Directed. 67 S&F In Repair Stain-Less Steel Wire Cloth, 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40 Mm And Fixed With Stainless Wire Staples Complete All As Specified And As Directed. 68 Hacking Out Old Broken Glass ( Any Thickness, Quality Or Description ) From Wooden / Steel Frame Or Stone Concrete Or Brick Surrounds, Glazed With Putty Or Fixed With Beads Complete All As Specified And As Directed. 69 S & F 3Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square N Exc 0.5 Sqm In Each Pane Complete All As Specified And As Directed. 70 S&F 3Mm Thick Figured Glass, Pin Head Type And Glazing With Oil Putty In Squares N Exc 0.5 Sq.M In Each Pane Complete All As Specified And As Directed. 71 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding But Not Backing Complete All As Specified And Directed. 72 M & L For Coloured Non Skid Ceramic Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exc 0.06 Sqm But N.Exc 0.11 Sqm, Laid In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Colour Of Tile Over And Including 15Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And As Directed. 73 M&L For Glazed Light Coloured / Printed Ceramic Tiles 300X200x7mm / 350X250x7mm / 450X350x7mm Thick In Vertical Surfaces Such As Skirting, Dado Etc Set And Jointed In Neat Cement Slurry, Pointed In White Or Coloured Cement To Match Colour Of Tiles, Over And Including 10 Mm Thickrenderingincement Mortar 1:4 Complete All As Specified And As Directed. 74 Demolition Of Stone Slab And Tiles Of Any Description Or Thickness In Floor, Apron Etc Laid, Bedded And Pointed In Cement Mortar Complete All As Specified And As Directed. 75 M&L For18 To 20 Mm Thick Granite ( Table Rubbed And Polished ) In Steps, Jambs, Pillars, Window Cills, Cooking Platform And The Like Including Pointing In White Cement 1:2 Using Granite Dust With Admixture Of Pigment To Match With The Shade Of Granite Work Including Rounding Of Exposed Edges Of Granite Over And Including 15Mm Thick Backing Coat In Cement Mortar 1:4 Complete All As Specified And As Directed. 76 Taking Up Or Down 15 Mm Bore Gi Tubingfrom Trenches / Wall Including All Fittings Segregated, Cleaning And Stacking The Pipe For Reuse At Site If Required Complete All As Specified And As Directed. Note : Excavation And Earthwork If Any Shall Be Included In The Quoted Rate 77 S & F Gi Tubing 15Mm Bore, Medium Grade With All Fittings And Fixed Complete To Walls And Ceilings Or Laid In Floors Complete All As Specified And As Directed. 78 Refixing Old Serviceable 15 Mm Bore Steel Tubingand Connections As Obtained From Taking Down Including Provision Of New Fittings, In New Or Old Position Ofwalls, Ceiling, Floor Etc.Complete All As Specified And As Directed. 79 Taking Up Or Down 20 Mm Bore Gi Tubingfrom Trenches / Wall Including All Fittings Segregated, Cleaning And Stacking The Pipe For Reuse At Site If Required Complete All As Specified And As Directed. Note : Excavation And Earthwork If Any Shall Be Included In The Quoted Rate. 80 S & F Gi Tubing 20Mm Bore, Medium Grade With All Fittings And Fixed Complete To Walls And Ceilings Or Laid In Floors Complete All As Specified And As Directed. 81 Refixing Old Serviceable 20 Mm Bore Steel Tubingand Connections As Obtained From Taking Down Including Provision Of New Fittings, In New Or Old Position Ofwalls, Ceiling, Floor Etc.Complete All As Specified And As Directed. 82 S & Fin Repairs, Bib Taps, 15Mm Dia Cast Copper Alloy Chromium Plated, Fancy Type With Crutch Or Butter- Fly Handles Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed. 83 S&F In Repairs, Ptmt Bib Taps 15Mm Dia Standard Any Colour Screwed Doen For Iron Pipeand Fixed ( Minimum Weight 90Gms ) Complete All As Specified And Directed. 84 S & F In Repairs, 15 Mm Bore Pillar Taps, Cast Copper Alloy With Capstan Heads Chromium Plated Screwed Down High Pressure With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly Nuts Screwed For Iron Pipe And Fixed Complete All As Specified And As Directed. 85 S & F In Repairs, Stop Valves / Angular Stop Valve, 15Mm Dia, Cast Copper Alloy, Fancy Type, Chromium Plated, Screwed Down, High Pressure With Crutch Or Butterfly Handle Screwed Both Ends For Iron Pipe Or Unions Complete All As Specified And As Directed. 86 S&F In Repairs, Grating Doom 125M Dia With Waste Hole Of Ptmt ( Minimum Weight 40 Gms ) Complete All As Specified And As Directed. 87 S & F In Repairs, Waste Coupling Of Ptmt 40Mm ( Half Or Full Thread ) Complete ( Minimum Weight -60Gms ) All As Specified And As Directed. 88 S & F In Repairs, Waste Coupling Of Ptmt 32Mm ( Half Or Full Thread ) Complete ( Minimum Weight -45Gms ) All As Specified And As Directed. 89 M&L For Mild Steel Bands, Supports, Or Stays For Rainwater, Ventilating Pipes, Including Bolts If Required, Hooks ( Stay ) , Heavy, For Large Gates, Hooks And Pintle Hinges, Large Hasp And Staples, Chains, Hand Made Sliding Bolts, Clamps, Holdfasts, Wall Ties, Hooks For Hanging Fans, Plain Angle Claets For Securing Purlins To Wood Trusses Or Rafters, Knee Piece Inserts, Two Way Or Three Way Starps, Plate Washers And Similar Small Articles Quality Confirming Tofe290-Gde E-165 Complete All As Specified & As Directed. 90 S&F In Repair, Brasschromium Plated Tubular Towel Rail Of 20Mm Dia And 60Cm In Length, D Shaped, With Brass Chromium Platedbrackets Complete All As Specified And As Directed. 91 S&F In Repair Pvc Waste Pipe Of Size 40Mm Dia For Sink Complete All As Specified And Directed. 92 S&F In Repair Pvc Waste Pipe Of Size 32Mm Dia For Wash Hand Basin Complete All As Specified And Directed. 93 S & F In Repairs, 600 Mm X 450 Mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thck Ac Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified And As Directed. 94 Disconnecting Existing Tanks, Setting Aside ( Or Lowering If Required ) For Cleaning Etc. And Hoisting If Required Reconnecting And Refixingin Position, Cleaning, And Removing All Scale And Dirt Etc From Tanks And From Mouth Of Circulating Pipes Of Capacity Upto 500 Litresincluding Writing The Date Of Cleaning On Water Tank With White Paint Complete All As Specified And As Directed. 95 S & F In Repairs, 500 Litres Capacity Rotational Moulded Polye-Thylene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position All As Specified In Ssr Part I With And Including 20Mm Bore Dia Ball Brass Valves, High Pressure, With Polythene Float And Flynut Complete, Screwed For Iron Pipe Or Brass Ferrule And Fixed Etc Complete All As Specified And As Directed. 96 S & F In Repairs, Vitreous China Wash Hand Basin, Whiteflat Back Size 550 Mm X 400 Mm Including Brackets Including Pillar Tap, 15 Mm Bore Chromium Plated, Cast Copper Alloy With Capstan Heads, 32 Mm Waste Coupling Brass Chromium Platedsuitable For Wash Hand Basins, With Long Screwed Shanks And Fly Nuts Andpvc Waste Pipe, 15Mm Dia Pvc Connection Pipe Complete All As Specified And As Directed 97 S & F Inrepairs, Vitreous China SquattingpanOrissa Pattern Size 580 Mmx440 Mm White With Integral Foot Rest Etc. ( Excluding Cistern And Flush Pipe ) Including S Or P Trap And Provision Of Concrete Bedding And Making Good To Floor Complete All As Specified And As Directed. 98 S&F In Repairplastic Water Closet Seat, White, Closed Pattern With Flat Bottom And Cover With Mild Steel Chromium Plated Or Aluminium Hinging Device Complete All As Specified & As Directed. 99 S&F In Repair40mm Dia Spout Medium Grade 40 Cm Long Fixed In Top Of Sunkenslabsincluding Cutting Holes To Wall And Making Good With Cm 1:2 Complete All As Specified & As Directed. 100 S & F In Repairs, 10 Litres Capacity Pvc Valveless Syphonic Action Type, Flushing Cistern, Low Level, White Or Coloured, With Inlet, Ball Valve, Float And Handle Including Brackets Etc Complete All As Specified And As Directed. 101 S & F In Repairs, 125 Mm, Dia Chromium Plated, Swivel Type Shower Rose With 190 Mm Long Chromium Plated Shower Arm And Wall Flange Suitable For Fixing 15 Mm Bore Iron Pipe Complete All As Specified And As Directed. 102 S&F In Repair Chromium Plated Soap Dish Of Approximate Size 160X160x90mm Embedded In Wallcomplete All As Specified & As Directed. 103 S&F Pvc Connections 15Mm Dia With Ptmt Nuts Of Length 450Mm Complete All As Specified And As Directed. 104 S & F In Repairs, Sink With Drainage Board Made Of Stainless Steel 1Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortat To Dwarf Wall Or Including Fixing Cantiliver Brackets And Connecting Union To Pipe Overall Size 915 Mm X 460 Mm Bowl Size 410 Mm X 330 Mm X 160 Mm Complete All As Specified And As Directed. 105 S & F In Repairs, Stainless Steel Kitchen Rack Made Of 0.63Mm Thick Stainless Steel Sheet Of Size, 786Mmx914mmx254mm Fixed To Wall With Screws Complete All As Specified And As Directed. 106 S&F In Repairs, 110Mm Dia Pvc ( Swr ) Pipes, Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls Complete All As Specified And As Directed. 107 S&F 110 Mm Dia Pvc ( Swr ) Bends Of Any Radiuscomplete All As Specified And Directed. 108 S&F100mm Dia Cast Iron Spun Bends ( Any Radius ) Diminishing Pieces Or Tapers.Complete All As Specified And Directed. 109 S&F100mm Dia Cast Iron Spun Bends ( Any Radius ) With Oval Access Door Diminishing Pieces Or Tapers.Complete All As Specified And Directed. 110 S&F Pvc ( Swr ) Branch Piece, Single ( Single -Y ) Equal Or Unequal 110Mm Dia Complete All As Specified &Directed. 111 S&F In Repair Cast Iron Floor Trap 100Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete Type B-I ( 1:2:4 ) Complete All As Specified & As Directed 112 S&F In Repairs, Cast Iron ( Sand Cast ) Soil, Waste, And Vent Pipes 100Mm Bore Of Any Length With Or Without Earswith Cement Jointscomplete All As Specified And As Directed. 113 Taking Out Old Unserviceable Ug Cable Of Any Size / Type From Trenches / Wall / Roof Etc. For Necessary Repair / Replacement / Re-Laying Works Complete All As Specified And As Directed. 114 M&L For Relayingold Serviceable Ug Cable Of Any Size / Typealongwith Brick Protection, Sand Cushioning Etc As Obtained From Taking Up / Down Old Cable Here In Before Intrenches / Wall / Roof Etc. After Necessary Repair / Rerouting If Directedcomplete All As Specified And As Directed. 115 M & L For Xlpe Insulated, Pvc Sheathed, Armoured, Heavy Duty Electric Under Ground Cable, With Stranded Aluminium Conductor, 1100 Volts Grade Of Size 16 Sqmm 4 Core Laid In Trenches / Floor Or Fixed On Wall / Poleincluding Brass Compression Cable Glands, Terminal Lugs Etc, Complete All As Specified And As Directed. 116 M & L For Xlpe Insulated, Pvc Sheathed, Armoured, Heavy Duty Electric Under Ground Cable, With Stranded Aluminium Conductor, 1100 Volts Grade Of Size 10 Sqmm 4 Core Laid In Trenches / Floor Or Fixed On Wall / Poleincluding Brass Compression Cable Glands, Terminal Lugs Etc, Complete All As Specified And As Directed. 117 M & L For Xlpe Insulated, Pvc Sheathed, Armoured, Heavy Duty Electric Under Ground Cable, With Stranded Aluminium Conductor, 1100 Volts Grade Of Size 10 Sqmm 2 Core Laid In Trenches / Floor Or Fixed On Wall / Poleincluding Brass Compression Cable Glands, Terminal Lugs Etc, Complete All As Specified And As Directed. 118 M & L For Xlpe Insulated, Pvc Sheathed, Armoured, Heavy Duty Electric Under Ground Cable, With Stranded Aluminium Conductor, 1100 Volts Grade Of Size 6 Sqmm 2 Core Laid In Trenches / Floor Or Fixed On Wall / Poleincluding Brass Compression Cable Glands, Terminal Lugs Etc, Complete All As Specified And As Directed. 119 Supply And Spreading Clean Dry River Sand In Cable Trenches As In Cable Cushioning Complete All As Specified And As Directed. ( Note: Punnedthickness Shall Be Measured And Paid ) 120 M&L For Sub Class ‘B’ Old Size Well Burnt Brick Laid Flat In Trenches Over The Cable Forprotection Of Lt Cable Complete All As Specified And As Directed. 121 M& L For Manual Boring Under Roads / Hard Standingby Required T&P Without Disturbing The Top Surface Of The Road For Passingthe Cable In Gi Pipe Of 40 Mm To 80Mm Dia Complete All As Specified And As Directed. 122 M&L For Gi Pipe Light Grade 40Mm Bore With All Fittings Laid In Trenches Or In Floors, Including Taking Up / Down Old Pipecomplete All As Speciffied And As Directed 123 M&L Forerection And Fixing Of Steel Tubular Swaged Pole Type 410 Sp - 31 ( 9.00 Metres Long ) Confirming To Is- 2713 Part I To Iii 1980 With And Including Cast Iron Base Plate, Finial Taper Plug, Nuts, Bolts And Washers Etc. Fixed In Pcc Foundationduly Painted Painted With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer Including Preparation Of Surface And Including Dismsntling Of Old Pole Of Any Size And Description With Foundation, Pcc Coping Etc. Complete All As Specified And As Directed. 124 M&L For Cement Concrete 1:4:8 Type D-2 Using 40 Mm Graded Crushed Stone Aggregate As In Foundation Fillingand Mass Concrete Complete All As Specified And As Directed. 125 M&L For Pcc 1: 3 : 6 Type C-1 Using 20 Mm Graded Stone Aggregatefor Coping To The New / Existingsteel Poles Including Necessary Form Work Complete All As Specified And As Directed. 126 S &F Street Light Fitting Of60 Watt Led Made Ofpressure Die Cast Aluminium Housing With Toughned Glass And Leds With Secondary Optics And Ip 66 Protectionand Lens Embedded Pc Cover Having Top Opening Seperate Driver Compartment, Should Have Luminaire Efficacy =110 Lumens / Watt, Cri>70 , Pf > 0.95, Cct=5500, Ip66, Impact Resistance Ik 07 , Inbuiltprotection Against Lightning , Over Voltage , Short Circuit And Surge / Spike Protection Device Upto10 Kv Complete Also Tested For 440 Volt For 8 Hour Phase To Phase Without Any Damageincluding Taking Down Old Unserviceable Light Fittings Complete Allas Specified And As Directed.Make : Magic Cat Part No. Spor060c0805 Or Equivalent In Philips / Havells / Crompton ( Note : ( I ) Pvc Insulated Pvc Sheathed, Multistranded Aluminium Or Copper Conductor Cable Of Size 1.5 Sqmmx 3 Core From Light Fitting To Street Light Feeder ( Max 2.0 Mtr ) Deemed To Be Included In Quoted Rate. ( Ii ) Manufacturer’S Test Certificate Of Led Light Fitting In Respect To Lm 79 And Lm 80 Shall Be Submitted By The Contractor. ) 127 S &F Street Light Fitting O F 45 Watt Led Made Ofpressure Die Cast Aluminium Housing With Toughned Glass And Leds With Secondary Optics And Ip 66 Protectionand Lens Embedded Pc Cover Having Top Opening Seperate Driver Compartment, Should Have Luminaire Efficacy =110 Lumens / Watt, Cri>70 , Pf > 0.95, Cct=5500, Ip66, Impact Resistance Ik 07 , Inbuiltprotection Against Lightning , Over Voltage , Short Circuit And Surge / Spike Protection Device Upto10 Kv Complete Also Tested For 440 Volt For 8 Hour Phase To Phase Without Any Damageincluding Taking Down Old Unserviceable Light Fittings Complete Allas Specified And As Directed.Make Magic Cat Part No..Spor060c0805 Or Equivalent In Philips / Havells / Crompton ( Note : ( I ) Pvc Insulated Pvc Sheathed, Multistranded Aluminium Or Copper Conductor Cable Of Size 1.5 Sqmmx 3 Core From Light Fitting To Street Light Feeder ( Max 2.0 Mtr ) Deemed To Be Included In Quoted Rate. ( Ii ) Manufacturer’S Test Certificate Of Led Light Fitting In Respect To Lm 79 And Lm 80 Shall Be Submitted By The Contractor. ) 128 Supply And Fix In Repair3 Pole, 415 V Power Contactor Of Ac3 Rating 32 Amp With Built In Surge Suppressor, Rohscompliant Including Necessary Electrical Connection With Suitable Size Copper Conductor Cablecomplete All As Specified And As Directed. Make : L&T Cat Part No Cs94568 Or Equilvalent In Havells / C&S. 129 Drillling And Taping Ofci / Di Pipesin Position For Branch Connection Suitable For 15Mm Diacomplete All As Specified And As Directed. 130 Cutting Ci / Di Pipes Of 150Mm Bore And Reducing To Required Length Before Laying Oin Position For Insertion Of Newtee, Branches Etc Complete All As Specified And As Directed. 131 Scutting Ci / Di Pipes Of 100Mm Bore And Reducing To Required Length Before Laying Oin Position For Insertion Of Newtee, Branches Etc Complete All As Specified And As Directed. 132 S&F Gi Tubing 50 Mm Bore, Medium Grade With All Fittings Complete Laid In Trenches Including Taking Out Old Existing Pipeline Of Any Description And Sizecomplete All As Specified And As Directed. 133 S&F Gi Tubing 40 Mm Bore, Medium Grade With All Fittings Complete Laid In Trenches Including Taking Out Old Existing Pipeline Of Any Description And Sizecomplete All As Specified And As Directed. 134 S&F Gi Tubing 25 Mm Bore, Medium Grade With All Fittingscomplete Laid In Trenches Including Taking Out Old Existing Pipeline Of Any Description And Sizecomplete All As Specified And As Directed. 135 S&F Gi Tubing 25 Mm Bore, Medium Grade With All Fittings And Fixed Complete To Wall, Ceiling Including Taking Out Old Existing Pipeline Of Any Description And Sizecomplete All As Specified And As Directed. 136 S&F Gi Tubing 20 Mm Bore, Medium Grade With All Fittingscomplete Laid In Trenches Including Taking Out Old Existing Pipeline Of Any Description And Sizecomplete All As Specified And As Directed. 137 S&F Gi Tubing 20 Mm Bore, Medium Grade With All Fittings And Fixed Complete To Wall, Ceiling Including Taking Out Old Existing Pipeline Of Any Description And Sizecomplete All As Specified And As Directed. 138 S&F Gi Tubing 15 Mm Bore, Medium Grade With All Fittingscomplete Laid In Trenches Including Taking Out Old Existing Pipeline Of Any Description And Sizecomplete All As Specified And As Directed. 139 S&F Gi Tubing 15 Mm Bore, Medium Grade With All Fittings And Fixed Complete To Wall, Ceiling Including Taking Out Old Existing Pipeline Of Any Description And Sizecomplete All As Specified And As Directed. 140 S & F In Repairs 50 Mm Bore Gun Metal Globe Or Gate Valve Cast Copper Alloy, Screwed Down, High Pressure With Iron Wheel Headscrewed Both Ends For Iron Pipecomplete All As Specified And As Directed. 141 S & F In Repairs 40 Mm Bore Gun Metal Globe Or Gate Valve Cast Copper Alloy, Screwed Down, High Pressure With Iron Wheel Headscrewed Both Ends For Iron Pipecomplete All As Specified And As Directed. 142 S & F In Repairs 25 Mm Bore Gun Metal Globe Or Gate Valve Cast Copper Alloy, Screwed Down, High Pressure With Iron Wheel Headscrewed Both Ends For Iron Pipecomplete All As Specified And As Directed. 143 S & F In Repairs 20 Mm Bore Gun Metal Globe Or Gate Valve Cast Copper Alloy, Screwed Down, High Pressure With Iron Wheel Headscrewed Both Ends For Iron Pipecomplete All As Specified And As Directed. 144 S & F In Repairs 15 Mm Bore Gun Metal Globe Or Gate Valve Cast Copper Alloy, Screwed Down, High Pressure With Iron Wheel Headscrewed Both Ends For Iron Pipecomplete All As Specified And As Directed. 145 Materials And Labour Forrun Leadjoints Suitable For 200 Mm Bore Cast Iron Spigot And Socket End Pipes And Fittingsincluding Dismantling Of Old Worn Out Joint By Burning Out Old Lead Etc Andtesting Complete All As Specified And As Directed. 146 Materials And Labour Forrun Leadjoints Suitable For 150 Mm Bore Cast Iron Spigot And Socket End Pipes And Fittingsincluding Dismantling Of Old Worn Out Joint By Burning Out Old Lead Etc Andtesting Complete All As Specified And As Directed. 147 Materials And Labour Forrun Leadjoints Suitable For 100 Mm Bore Cast Iron Spigot And Socket End Pipes And Fittingsincluding Dismantling Of Old Worn Out Joint By Burning Out Old Lead Etc Andtesting Complete All As Specified And As Directed. 148 Materials And Labour Forrubber Or Fibre Board Gasket For Flanged Joints For Size 150Mm Dia Pipe Complete All As Specified And As Directed. 149 Materials And Labour Forrubber Or Fibre Board Gasket For Flanged Joints For Size 100Mm Dia Pipe Complete All As Specified And As Directed. 150 Materials And Labour Forci Fittings For Spigot And Soket Pipes Of Size Upto 150Mm Bore Such As Bends, ( Any Type, Radius And Angle ) Tapers Any Type ( Straight, Bend, Increasing Or Decreasing Or Double Socket Etc. ) Tee Pieces Single Branch Y Junction, Double Branch, Cross ( All Sockets Or Socket And Spigot ) Collars Caps And Plugs Complete All As Specified And As Directed. 151 S&F In Repairs, Sluice Valve ( Heavy Duty ) With Heavy Duty Stainless Steel Spindle Conforming To Is 14846 ( 2000 ) Both End Flanged Class Pn 1.6 Of Size 150 Mm Dia Including Necessary Nuts, Bolts Washers And Gasket Complete All As Specified And As Directed. 152 S&F In Repair20mm Dia Ballbrass Valves High Pressure Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ballscrewed For Iron Pipe ( Minimum Weight 210 Gms ) Complete All As Specified & As Directed.