}

Tender For Annual Maintenance Contract Of Iip Staff Quarters Colony (Electrical Work) 2022-23, mohkampur-Uttarakhand

Statutory Bodies & Commissions/Committees has published Tender For Annual Maintenance Contract Of Iip Staff Quarters Colony (Electrical Work) 2022-23. Submission Date for this Tender is 28-12-2022. Coats and Jackets Tenders in mohkampur Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

35351611
Tender For Annual Maintenance Contract Of Iip Staff Quarters Colony (Electrical Work) 2022-23
Open Tender
Indian
Uttarakhand
Mohkampur
28-12-2022

Tender Details

Tender For Annual Maintenance Contract Of Iip Staff Quarters Colony ( Electrical Work ) 2022-23 - Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5Sqmm Frls Pvc Insulated Copper Conductor Single / Multi Core Cable In Surface / Recessed Steel Conduit Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point / With 1.5Sqmm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit ( Akg / M-Key ) , With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. 2 Group A 3 Wiring For Circuit / Submain Wiring Along With Earth Wire The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit ( Plaza / Kaliga ) As Required 4 2X1.5 Sq Mm + 1X1.5 Sq Mm Earth Wire 5 2X2.5 Sq Mm + 1X2.5 Sq Mm Earth Wire 6 2X4 Sq Mm +1X4 Sq Mm Earth Wire 7 2X6 Sq Mm + 1X6 Sq Mm Earth Wire 8 4X4 Sq Mm + 2X4 Sq Mm Earth Wire 9 Supplying And Drawing Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 10 3 X 1.5 Sq Mm 11 3 X2.5 Sq Mm 12 3 X 4 Sq Mm 13 3 X 6 Sq Mm 14 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recessed Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 15 20 Mm 16 25 Mm 17 32 Mm 18 Supplying And Fixing Metal Box Of Following Size ( Nominal Size ) On Surface Or In Recessed With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc As Required. 19 100 Mmx 100 Mmx 60 Mm Deep 20 180 Mmx 100 Mmx 60 Mm Deep 21 200 Mmx 125 Mmx 60 Mm Deep 22 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc As Required. 23 5 / 6 Amps Switch 24 2 Way 5 / 6 Amps Switch 25 15 / 16 Amps Switch 26 3 Pin 5 / 6 Amps Socket Oulet 27 6 Pin 15 / 16 Amps Socket Oulet 28 Bell Push 5 A 29 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Plate Etc As Required. 30 Supplying And Fixing Following Metal Box Of 180Mm X 100Mm X 60Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Fornt Including Providing And Fixing 6Pin 5A & 15 A Socket Outlet And 15 A Piano Type Switch, Connection, Painting Etc. As Required . 31 Supplying And Fixing 3 Pin, 5A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connection Etc As Required. 32 Supplying And Fixing Brass Batten / Angle Holder Including Connection Etc. As Required 33 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rod Of Standrand Lenght ( Up To 30Cm ) With 1.5 Sq.Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required 34 Painted Of Ceiling Fan In Installed Position With One Or More Coats Of Spray Painting With Synthetic Enamel Paint Of Apporved Brand And Manufactuer To Give An Even Shade, Including Cleaning Of Surface With Detergent Etc As Required. 35 Supplying And Fixing 5 Amps To 32 Amps Rating, 240V / 415V, C Curve, Miniture Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connection, Testingand Commissioning Etc. As Required 36 Single Pole 37 Siingle Pole And Neutral 38 Double Pole 39 Tripple And Neutral 40 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connetion, Testing And Commissioning Etc. As Required. 41 63 Amps 42 Supplying And Fixing Following Rating, Four Pole, 415V, Isolator In The Existing Mcb Db Complete With Connection, Testing And Commissioning Etc. As Reqired. 43 63 Apms 44 Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) 240 V , Residual Current Circuit Breaker ( Rccb ) Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc As Reqired. 45 63 A 46 Supplying And Fixing 32 / 40 Mm Dia X 2.00 Meters Long G.I Pipe ( Meidum Class ) Bracket For Mounting Of Fiuorscent / Hpmv / Hpsv Street Light Fitting On Pole Including Bendingshape, 2 Nos. 40 Mmx 3Mm Flat Iron Clamps With Nuts, Bolts Andthe Pipe To The Require Washer, Painting The Flat Iron Primer And Finish Piant Etc As Required. 47 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, 30Cm, Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding , Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise = 75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230V, 50Hz, Single Phase Ac Supply, Earthing Etc Complete As Required. 48 Supplying, Installation, Testing And Commissioning Of Passive Infrared ( Pir ) Technology Based Occupancy Sensor Having High Preformance, Non Regulating Programmable Type, Suitable For Connected Load Upto 10Amp, For Mounting Htight Up To 2.8 Mtr And For 5 Meter Diameter Coverage Area Along With Necessary Fixing Arrangements I / C Programming At Site Etc. Complete As Required 49 Supply Of Labour For Attending Day To Day Complaints Complaints Of Electrical Maintenance Work For Repair And Replacement Of All Electrical Accessories In Non Workingelectrical Fittings And Fixture ( Such Main Boards, Fans, Geysers Switches, Sockets, Light Fittings, Motors, Starters, Street Light, Energy Meters In Lab Buildings, Underground And Overhead Line Distribution Network Including Service Main, Operation And Maintenance 33Kv / 415V Substation And Power House ( 24 Hour Round The Clock ) All Other Electrical Work As Assigned By Site-Incharge. 50 Skilled Labour In Electrical Trade 51 Unskilled Labour In Electrical Trade 52 Attending Day To Day Complaints Of No Light / Non Working Points / Providing Temporary Connections, Hostel & Guest House, Dispensary, Water Supply, Club, Colony Street Etc As Required. 53 Attending Emergency Comapaints During Off Office Hour Of No Light / Non Working Points / Providing Temporary Connections In Iip Colony And Diip Bunglow Etc As Required. 54 Disconnecting, Removing, Repairing And Reinstallation Of Metal Halide / Led Fittings Etc On Street Light Pole For The Following Heights. 55 Height Upto 2 Meter 56 Height Upto 6.5 Meter 57 Supplying, Fixing And Commissioning Of Exhaust Fan Of 300 Mm Sweep 900 / 1400 Rpm Suitable For 230V 50Hz Ac Supply Complete With Blade, Regular, Frame And Moving System Etc As Required .The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 58 Supply And Replacemant Of Capacitor Of Ceiling Fans / Exhaust Fan / Wall Fan / Padestal Fan Of Size Of 2.5 To 4 Mfd Etc As Required 59 Supply And Fixing Of Following Led Energy Saving Surface / Pendent Mounting Led Lamp Fitting With Powder Coated / Batten With In Bulit Electronic Ballast With Decortive End Caps Etc. As Required. 60 1 X 4 X 20W Led Luminaries With Tube Rod. 61 2 X 4 X 20W Led Luminaries With Tube Rod. 62 Supplying And Fixing Following High Efficiency Led Tube Rod Lamps Led Luminaire In Existing Fitting Fixture With Connection Etc. As Required. 63 4 X 20W Led Luminaries Tube Rod. 64 Overhauling, Rewinding Oiling Greasing Of Ceiling Fan / Exhaust Fan / Pedsetal Fan / Wall Fan Of Any Size Including Supply And Replacement Of Ball Bearing / Bush Capacitor , Split Pin Rubber Wire, Shaft, Nut & Bolt 2X1.5 Sqmm Copper Connecting Wire, Cleaning Varnishing , Upto 300 Watt Etc Complete In All Respect As Required. 65 1400 Mm Ceiling Fan Rewinding 66 Supplying And Fixing 15 Watt, 6000K New Generation Led Post Of Lanturn Light Luminare Ip 65, Energy Saving, Enviornmental Friendly, Long Life Aesthetically Designed With Symmetrical Light Distribution, Spun Aluminium Lad Scape Luminaire With High Power Leds As Light Souce. Clear Cover Offers Bright Illumination For Different Application. ( Havells / Wipro / Philiphs / C&S ) . The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 67 S / R Of Following Watt Led Strret Luminaire, New Genration Energy Savin And Enviornmental Friendly Long Life Led Street Light Made Uo Of Pressure Die Cast Aluminium Housing With High Efficiency Led S Lighting Source And Toughened Glass Having Bottom Opening Seperate Driver Compartment With Ip 66 Protection And Impact Resistance Of Ik07. ( Bajaj / Havells / Philiphs / Wipro ) . The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 68 25 W Led Luminaire 69 30 W Led Luminaire 70 Supplying And Drawing Folowing Size Of Pvc Insulated Aluminium Flat Twin Core Weather Proof Cabe In Existing Pipe Or Surface Etc As Required. 71 2 X 6 Sqmm 72 Supplying And Installation Of Three Phase 4 Wire 10 A -60 A Isi Marked Electronic Class 1.0 50 Hz 3 X 240 V Ac Poly Carbonate Body Energy Meter 73 Supplying And Installation Of Single Phase 2 Wire 5 A -30 A Isi Marked Electronic Class 1.0 50 Hz 3 X 240 V Ac Poly Carbonate Body Energy Meter 74 Supply And Fabrication Of Sheet Steel Mcb Enclosure Fitted With Din Rail For Mcb Of Following Rating Complete With Connections Including Drilling Holes Etc As Required. 75 Four Pole Enclosure

Key Value

Document Fees
INR 590 /-
EMD
INR 17500.0 /-
Tender Value
INR 8.63 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail