Tender For Procurement Of Different Rating Control Transformers For 2X600 Mw, Sstpp, Mppgcl, Dongalia., dongalia-Madhya Pradesh

Madhya Pradesh Power Generating Company Limited has published Tender For Procurement Of Different Rating Control Transformers For 2X600 Mw, Sstpp, Mppgcl, Dongalia.. Submission Date for this Tender is 23-01-2023. Lifting Equipment Tenders in dongalia Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

35338362
Corrigendum : Tender For Procurement Of Different Rating Control Transformers For 2X600 Mw, Sstpp, Mppgcl, Dongalia.
Open Tender
Indian
Madhya Pradesh
Dongalia
23-01-2023

Tender Details

Procurement Of Different Rating Control Transformers For 2X600 Mw, Sstpp, Mppgcl, Dongalia. , Control Transformer Of 5000Va Rating- 5000 Va Primary Volt- 440± 10% Secondary Volt- 240 Vregulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Lighting Transformer Of 3000Va Rating- 3000 Va, 3 Phase Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 440, Tapes At ± 2.5%, 5%, Type- An, Vector Group :- Dyn11 Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Service Building Chiller Control Transformer Of 2000 Va Rating- 2000 Va Primary Volt- 440± 10% Secondary Volt- 0-220 V & 0-220 V Secondary 1: 0-220 V ( 1.5A ) Secondary 2: 0-220V ( 7.0A ) Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Lt Buses Control Transformer Of 2000Va Rating- 2000 Va Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 240 Vac, Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Tg Eot Control Transformer Of 2000Va Rating- 2000 Va, Insulation Class F Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 110 Vac, 18.50Aregulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Cw Eot Control Transformer Of 1200Va Rating- 1200 Va, Insulation Class F. Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 110 Vac, 11A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Esp Rcp Control Transformer Of 1000Va Rating-1000 Va.Insulation Class F. Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 230-240 Vac, 4.2A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , St & Ut Oltc Control Transformer Of 500Va Rating- 500 Va, Insulation Class F. Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 55-0-55 Vac, 4.5A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Esp Ecp Control Transformer Of 500 Va Rating- 500 Va Primary Volt- 440± 10% Secondary Volt : -250 V Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Restistance Should Be More 50M Ohm , Condenser Mcc Control Transformer Of 400Va Rating- 400 Va, Insulation Class F. Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 230-240 Vac Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Esp Eot Control Transformer Of 300Va Rating. Rating- 300 Va Primary Volt- 415 ± 10%, 50Hz Secondary Volt- 110 Vac, 2.7A Type- An, Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Restistance Should Be More 50M Ohm , Wtp & Chlorination Hoist Control Transformer Of 300 Va Rating- 300 Va, Primary - 440V± 10%, 0.68A Secondary: -250 V, 2.68A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Restistance Should Be More 50M Ohm , Esp Ecp Control Transformer Of 250 Va Rating. Rating- 250 Va Primary - 440V± 10%, 0.73A Secondary: -250 V, 2.73A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Compressor , Dm , Rwis, Esp, Fire, Tac & Mill Hoist Control Transformer Of 250 Va Rating. Rating- 250 Va Primary - 440V± 10%, 0.73A Secondary: -110 V, 2.73A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Esp Rapcon Control Transformer Of 250Va Rating- 250 Va, Insulation Class F. Primary Volt- 440 ± 10%, 50Hz Secondary Volt- 24 Vac, 10.5A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Rwph & Filter Building Hoist Control Transformer Of 200 Va Rating. Rating- 200 Va Primary - 440V± 10%, 0.48A Secondary: -110 V, 1.81A Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Silo Modules Control Transformer Of 140Va Rating- 140 Va Primary Volt- 0 / 400 / 440 / 460, 50Hz Secondary Volt- 0 / 24 / 110 / 220 Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Naoh Dosing Panel Control Transformer Of 100Va Rating. Rating- 100 Va Primary Volt- 415 ± 10%, 50Hz Secondary Volt- 230-240 Vac, 0.50A Type- An, Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm , Esp Control Transformer Of 100 Va Rating- 100 Va Primary Volt- 440± 10% Secondary Volt- 24 V & 18 V Secondary 1: 0-24 V ( 3.2A ) Secondary 2: 0-18V ( 1.2A ) Type-An Regulation :- < 3.5% Efficiency :- > 95% , Pf :- 0.75 ( Lead / Lag ) Insulation Class F / 155°C Or H Single Phase Is-12021 Or Latest Revisions Of All Relevant Standards Available And Insulation Resistance Should Be More 50M Ohm

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 10-01-2023 First extension Date 23-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 19900.0 /-
Tender Value
INR 9.96 Lakhs /-