| 1 | M&L for Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit or Caping-N-Casingwith and includingmodular switch, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required all as specified and directed(Group A) |
| 2 | M&L for Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduitor caping-N-casing including2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required |
| 3 | Suplying and fixing following modules swithch/ socket on the existing modules plate & switch box including connetions but excluding modules plate etc as requied.(a) 15/16 amp switch |
| 4 | (b) 3 pin 5/6 amp socket outlet |
| 5 | (c) 3 pin15/ 16amp socket outlet |
| 6 | (d) 2 way 5/6 amps switch |
| 7 | Supplying and fixing fowlloing size/ modules GI box along with modules base & cover plate for modular swithes in recessetc as requied. (a) 1 or 2 module (75mmx75mm) |
| 8 | (b) 3 modules (100mmx75mm) |
| 9 | (c) 4 modules (125mmx75mm) |
| 10 | (d) 6 modules (200mmx75mm) |
| 11 | (e) 8 modules (125mmx125mm) |
| 12 | Supplying and fixing 3 pin 5amp ceiling rose on the existing junction box/ etc as requied . |
| 13 | Material and labour for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dollyand specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore light grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point etc complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order.(ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order (For Main DBs) (iii) Item includes the cost of Charcoal and commercial salt. |
| 14 | Supplying and fixingPVCbatten / angle holder incl connection as reqd complete all as specified and directed |
| 15 | Supplying and fixing following way single pole and neutral, sheet steel MCB distribution board 240 valts on surface/recess complete, with tinned copper bus bar, neutral bus bar, earth bar, din bar,inter connection , powder pointed including earthing etc as requied (But with out MCB/RCCB/Isolater)(a) 6 way double door |
| 16 | (b) 8 Way double door |
| 17 | (c) 12 Way double door |
| 18 | Supplying and fixingof following ways surface/recess mounting,verticle type 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of200 Amp tinned copper busbar,common neutral link,earth bar, din ba for mounting MCBs and incomer) as requird.(Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.). 4Way(4 + 12) double door |
| 19 | S&F in replacement of MCB \"C\" Curve type, 10 kA, 5 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed. |
| 20 | All as srl item no 27.00 here in before but of 40amps capacity andSPN type. |
| 21 | All as srl item no 27.00 here in before but of 63amps capacity andSPN type. |
| 22 | Supply and fixing of rating four pole, 415 volts, isolator in the existing MCBDB complete with connections, testing and commissioning etc as reqd but of 100 amps capacity |
| 23 | Wiring for circuit/ submain wiring along earth wire with the 2x2.5 sq mm+1x2.5 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as requed.. |
| 24 | Wiring for circuit/ submain wiring along earth wire with the 2x4 sq mm+1x4 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as requed. |
| 25 | Wiring for circuit/ submain wiring along earth wire with the 2x6 sq mm+1x6 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as requed.. |
| 26 | Wiring for circuit/ submain wiring along earth wire with the 2x10 sq mm+1x10 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as requed.. |
| 27 | Wiring for circuit/ submain wiring along earth wire with the 4x6 sq mm+2x6 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as requed.. |
| 28 | Wiring for circuit/ submain wiring along earth wire with the 4x10 sq mm+2x6 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as requed.. |
| 29 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 30 | fixing onlypre-wired light fittings of LED/ flurecent/compact fluoverscent fittingwith all accessorieson ceiling/wall including connetion with 1.5 sqmm FRLS PVC insulated, copper inductor, single core cable and earthing etc as rwquied all as specified and directed. Note : Light fittings will be under Sch \"B\" store. |
| 31 | Fixing onlyExhaustfan of any sweep/typeincuding making all electric connections complete all as specified anddirected.Note : Exhaust fan will be issued under Sch \"B\" store |