Maintenance Of Various Sports Complexes.Sub Head : Supply And Replacement Of Swimming Pool Filtration Plant Related Equipments And Accessories At Siri Fort Sports Complex. - Removing Of Existing Filter Media, Repair And Servicing I / C Chnging The Lateral Pipe, Distribution System And Other Pipe Inside The Existing Filter Of Capacity Of125 M³ / Hr. Withfiltration Velocity Of Not More Than 40 M³ / Hr / M² And Working Pressure Of 2.5 Kg / Sq Cm, Complete As Per Technical Specification & Conditions Attached. 2 Supply, Installation, Testing & Commissioning Of Valves Battery Manifold Made In Pvc With Flanges For Connecting To Filters Consists Of Set Of 5 No. Butterfly Valves Of Size 140 / 160 Mm For Carrying Out Filteration, Back Washing, Rising And Shut Down Of Filters Including Valve Battery Supports Made Out Of Zinc Plated Steel And Support Brackets With Anti-Cortex Clamps Complete As Per Technical Specification & Conditions Attached. ( Dismantling And Rebate Of Old Item Included ) 3 Supply, Installation, Testing & Commissioning Of Support Brackets With Anti-Vibration Clamps And Accessories For Ø 140 / 160 Mm Pipe. Box Consists Of 2 Support Brackets Complete As Per Technical Specification & Conditions Attached. ( Dismantling And Rebate Of Old Item Included ) 4 Supply, Installation, Testing & Commissioning Of Zinc-Plated Steel To Support Valve Battery Fitted For Filters. Height 2.30 M. ( Required 2 Nos ) . Each Filter Complete As Per Technical Specification & Conditions Attached. ( Dismantling And Rebate Of Old Item Included ) 5 Supplying, Laying, Testing And Commissioning Of Following Media For Filters Complete As Per Technical Specification & Conditions Attached. ( Dismantling And Rebate Of Old Item Included ) A ) Sand 0.4 - 0.8 Mm ( Dismantling And Rebate Of Old Item Included ) 6 B ) Gravel 1- 2 Mm ( Dismantling And Rebate Of Old Item Included ) 7 Supply, Installation, Testing & Commissioning Of 10 Hp Monoblock Recirculation Pump With Cast Iron Body, Bronze Impeller To Be Operated On 415V, 3 Phase Ac Supply And Suitable For The Discharge Of 120-125 M3 / Hr Of Water Flow At A Head Of 12M With Base Frame, Pressure Gauge, Ss Strainer Including Foundation And Other Accessories ( Dismantling And Rebate Of Old Item Included ) 8 Supply, Installation, Testing & Commissioning Of Following Size Of Electronic Membrane Dosing Pumps ( Ip-65 Protection ) Floor / Wall Mounted Suitable For Operation On 220 V, 50 Hz With A Flow Rate Of 20 Liter Per Hour At Pressure Of 5 Bar With Transparent Polycarbonate Protection For Operation Panel Complete As Per Technical Specification & Conditions Attached. ( Dismantling And Rebate Of Old Item Included ) 9 Supply, Installation, Testing & Commissioning Of Semi Transparent Polyethelene Tank , Capacity Of Tank 500Lts Complete As Per Technical Specification & Conditions Attached. ( Dismantling And Rebate Of Old Item Included ) 10 Supply, Installation, Testing & Commissioning Of Agitators For Easy Installation In The Tanks, Length Of Stirring Rod 900Mm Complete As Per Technical Specification & Conditions Attached. ( Dismantling And Rebate Of Old Item Included ) 11 Supply, Installation, Testing & Commissioning Of The Following Size Of Pvc ( Unplasticised Polyvinylchloride ) Butterfly Valves / Ball Valves ( Level Operated ) Suitable For 10 Kg Per Sq Cm Pressure With Epdm Seat, Nuts, Bolts, Washer Etc. Complete As Per Technical Specification & Conditions Attached. ( Dismantling And Rebate Of Old Item Included ) A ) Supply, Installation, Testing & Commissioning Of Ball Valve Dia 63 Mm. ( Dismantling And Rebate Of Old Item Included ) 12 Supply, Installation, Testing & Commissioning Of Butterfly Valve Dia 160 Mm. ( Dismantling And Rebate Of Old Item Included ) 13 Supply, Installation, Testing & Commissioning Of 63 Mm Non Return Valve. ( Dismantling And Rebate Of Old Item Included ) 14 Supply, Installation, Testing & Commissioning Of 160 Mm Non Return Valve. ( Dismantling And Rebate Of Old Item Included ) 15 Supply, Installation, Testing & Commissioning Of Flange And Adaptor For 160 Mm. Complete As Per Technical & Conditions Attached. ( Dismantling And Rebate Of Old Item Included ) 16 Supply, Installation, Testing And Commisioning Ofthe Following Size Of Upvc ( Unplasticised Polyvinylchloride ) Pipes With Minimum 10 Kg / Cm2 Pressure Including Required Size Of Fittings I.E Coupling, Tees, Bends, Flanges, Complete As Per Technical Specification & Conditions Attached. ( Dismantling And Rebate Of Old Item Included ) A ) 63Mm Dia 17 160Mm Dia 18 315 Mm Dia 19 315Mm Dia - Delivery Header Line 20 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.A ) 2 X 2.5 Sq. Mm ( Dismantling And Rebate Of Old Item Included ) 21 B ) 4X10 Sq Mm ( Dismantling And Rebate Of Old Item Included ) 22 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. 23 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5 %, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.A ) 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness ( Dismantling And Rebate Of Old Item Included ) 24 Sitc Of 2 Hp Self Priming Pump To Priming The All Pumps With Following Specification. Outlet Size 50Mm, 2 Hp 1.5 K / W 3000 Rpm, Solidhandling Capacity 35Mm Head Range ( 3 To 14 Meter ) Discharge Range 600 To 1000 Lpm With Connection Testing Complete As Per Technical Specification & Conditions Attached ( Dismantling And Rebate Of Old Item Included ) 25 Sitc Of Heat Pump With Heating Outpur 210 Kw Including Compressor Of Similar Output And Filling Of Gas In Heat Pump For The Swimming Pool. Electric Load Input For Each Pump 40-46 Kw As Per The Manufacturer Specifications: ( Dismantling And Rebate Of Old Item Included ) 26 Supplying Of 400 Gm / Hr Ozonator 50X25 Meter Swimming Pool As Per The Following Specifications.Attached In Annexure-A ( Dismantling And Rebate Of Old Item Included ) 27 Replacing The De-Ozonization Material ( Media ) From The Existing Tanks. ( Dismantling And Rebate Of Old Item Included ) 28 Sitc Of Suction Sweeper Set And Cleaning Equipment As Per Following Specificaitons : Abs Body Self Priming Pump Of 2 / 3 Hp Power Capable For 30, 000 Lph And Having 50Mm Inlet And Out Let Connection, Pump Should Be With The Pot Strainer To Prevent The Leaves Etc And With A Tranparent Cover And The Key To Open The Cover. Ss-304, 4 Wheel Heavy Duty Trolley For The Pumpset, Cartridge Filter, Dol Starter, Hanging Provision For Cable And For The Rope, Suction Head Of Stainless Steel Of Size 900X200x150mm ( D ) With 50Mm Threaded Ss-304 Socketm 4 Nos Of Wheel, 2 Nos Of Wooden Brushes With Pvc Bristles, Cartridge Filter Of Dia 200Mm -250Mm And Height Of 900Mm With Cartridge, Pressure Gauge, Cover, Lid Etc Complete In All Respect Vertically Mounted On Trolley 20Mm Dia Nylon Rope - 100 Meter 2.5Mm2 X 3 Core Submerssible Cable - 100 Meter 50Mm Dia Blue Or Transparent Hose Pipe - 60 Meter ( Dismantling And Rebate Of Old Item Included )