}

Tender For 1 To 2 Repairing And Replacement Of Electrical Accessories, Light Fittings In Qtr. No. E-2, Delhi Fire Service Hqs Staff Quarters, Connaught Place, New Delhi., new Delhi-Delhi

Public Works Department has published Tender For 1 To 2 Repairing And Replacement Of Electrical Accessories, Light Fittings In Qtr. No. E-2, Delhi Fire Service Hqs Staff Quarters, Connaught Place, New Delhi.. Submission Date for this Tender is 21-12-2022. Storage Chests and Cabinets and Trunks Tenders in new Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

35293132
Tender For 1 To 2 Repairing And Replacement Of Electrical Accessories, Light Fittings In Qtr. No. E-2, Delhi Fire Service Hqs Staff Quarters, Connaught Place, New Delhi.
Open Tender
Indian
Delhi
New Delhi
21-12-2022

Tender Details

Tender For 1 To 2 Repairing And Replacement Of Electrical Accessories, Light Fittings In Qtr. No. E-2, Delhi Fire Service Hqs Staff Quarters, Connaught Place, New Delhi. - Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( A ) Group B 2 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel Conduit Including Dismantling As Required. ( A ) Group B 3 Wiring For Circuit / Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. ( A ) 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 4 ( B ) 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 5 ( C ) 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 6 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( A ) 3 X 1.5 Sq. Mm 7 ( B ) 3 X 4 Sq. Mm 8 ( C ) 3 X 6 Sq. Mm 9 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 A & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 10 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. ( A ) 12 Module ( 200 Mmx150 Mm ) 11 ( B ) 8 Module ( 125 Mmx125 Mm ) 12 ( C ) 6 Module ( 200 Mmx75 Mm ) 13 ( D ) 3 Module ( 100 Mmx75 Mm ) 14 ( E ) 1 Or 2 Module ( 75 Mmx75 Mm ) 15 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. ( A ) 5 / 6 A Switch 16 ( B ) 3 Pin 5 / 6 A Socket Outlet 17 ( C ) 15 / 16 A Switch 18 ( D ) 6 Pin 15 / 16 A Socket Outlet 19 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required. ( A ) 1 Or 2 Module 20 ( B ) 3 Module 21 ( C ) 6 Module 22 ( D ) 8 Module 23 ( E ) 12 Module 24 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) ( A ) 12 Way, Double Door 25 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Offollowing Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( A ) Single Pole 26 ( B ) Single Pole And Neutral 27 Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 V, Complete As Required 28 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 29 Supplying & Fixing Of 10 Watts Wall Mounted Mirror Led Luminaries ( 2 Ft. ) Working On 230Volts Ac Supply Complete With Connection & Testing Etc. As Required. 30 Supplying, Installation, Testing & Commissioning Of Led Surface Mounted 10 Watt Ip66 ( Waterproof ) Glarefree, Pressure Die Cast Aluminium Housing With Unbreakable Polycarbonate Diffuser Bulk Head Fitting. Total System Lumen Of 10W Led Should Be 550 Or Above In Cool Day Light ( 5700K To 6500K ) , Power Factor>0.95, Cri>75. Complete With All Accessories As Required I / C Connections With 1.5 Sq. Mm Pvc Copper Wire Etc. As Required. 31 Supplying, Installation, Testing & Commissioning Of 20 - 22 Watt Of 1200 Mm Long, 6500K Energy Efficient Led Wall Mounted Batten Light, Extruded Aluminum Heat Sink Provided For Efficient Heat Dissipation & Integrated Electronic Driver, Suitable To Work 230 Volt Ac Supply Complete With Connection Etc. With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. The Luminaries Shall Be Submitted With Lm-80 Report With A Life Of 50000 Hours @ L-70 And Led Photo Biological Safety Report Conforming To Iec 62471 & Led Source Manufacturer And Lm-79 Report From Nabl Accredited Lab. The Led Chip Should Be Of Cree, Nichia, Philips Lumiled, Osram, Edison Etc. Complete As Required. 32 Supplying, Installation, Testing & Commissioning Of Energy Efficient Recessed Mounted Type 34W To 36W Full Window Glare Free Opal Diffuser Led Panel Luminaries Of Size 2 X 2 Feet ( Nominal Size ) Including Connections With 3 X 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. The Total System Wattage Not More Than Of 36W, Led Lumen Should Be = 3960 System Efficacy Of = 110 Lumen / Watt Colour Temperature 4000K To 5700K, Power Factor>0.95, Cri ( Ra ) >80, Thd <10%, With Apfc Driver Having Driver Efficiency >85%, Operating Voltage 150-270 Volts With Minimum 2.5Kv Surge Protection. The Luminaries Shall Be Submitted With Lm-80 Report With A Life Of 50000 Hours @ L-70 And Led Photo Biological Safety Report Conforming To Iec 62471 & Led Source Manufacturer And Lm-79 Report From Nabl Accredited Lab. The Led Chip Should Be Of Cree, Nichia, Philips Lumiled, Osram, Edison. 33 Supplying, Installation, Testing & Commissioning Of Energy Efficient Led Flood Light Luminaries Of System Wattages 100 Watt Complete With Mounting Brackets And Accessories On The Street Light Pole With Help Of Tower Wagon Including Connections Complete As Required. The Led Luminaries Should Confirm The Following Technical Specifications:-A ) Type Of Led: High Power Leds Nichia / Osram / Cree / Philipsb ) Driver Efficiency >85%C ) System Efficacy >110Lm / Wd ) Color Index ( Cri ) Ra>70E ) Color Temperature ( Cct ) Cool White: 4000°Kf ) Input Voltage. 140-270V Acg ) Frequency Range 50-60Hzh ) Power Factor ( Pf ) > 0.95I ) Surge Protection = 10Kvj ) Total Harmonic Distortion ( Thd ) < 10%K ) Working Environment 0°C To 50°C;10%-90%Rh L ) Working Lifetime: >50000 Hrs.M ) Ip Rating :- Ip66n ) Housing And Finish:-Epoxy Powder Coated Die Cast Aluminum Housing With Elegantly Designed Heat Sink For Efficient Thermal Management And To Excellent Corrosion Resistant, Cable Gland P49 Is Provided At Cable Entry Cover & High Quality Toughned Glass. 34 Supplying, Installation, Testing & Commissioning Of Energy Efficient Following Size Ceiling Fan Including Wiring The Down Rod Of Standard Length ( Up To 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Including Providing And Fixing Phenolic Laminated Sheet Cover On Fan Box Etc. As Required. ( A ) 1200 Mm Sweep Size 35 Supplying, Installation, Testing And Commissioning Of 400 Mm Sweep Size Heavy Dutywall Mounted Fan Complete With Inbuilt Electronic Regulator, Blade, Wire Lead With Moulded Plug Top Etc. As Required. 36 Supplying And Fixing, Fresh Air Fan Of 250 Mm Sweep Size Suitable For 220 Volts, 50 Hz, A.C. Supply, In The Exisitng Opening Including, Making The Hole To Suit The Size Of The Above Fan, Making Good The Damages, Connection, Testing, Commissioning Etc As Required. 37 Supplying, Installation, Testing & Commissioning Of 70 Litre Desert Cooler With Wood Wool Cooling Pads Having 3 Speed Control, Water Level Indicator, Oscillating Swing Control, Castor Wheels, Works On Inverter Suitable For Operation Of 230 Volts, 50Hz, Single Phase Ac Supply Etc. Complete As Required. 38 Supplying, Laying And Fixing Of Following Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Armoured Power Cable Of 1.1 Kv Grade Etc As Reqd. In The Following Manner: ( A ) 2 X 10 Sq.Mm On Wall Surface 39 ( B ) 4 X 16 Sq.Mm On Wall Surface 40 Credit Of Following Electrical Accessories Etc. Complete As Required. ( A ) Assorted Copper Wire / Cable 41 ( B ) Scrap Iron / Conduit / Box 42 ( C ) Switch / Socket ( Assorted Size ) 43 ( D ) Convention / Led Luminaires ( Assorted Size ) 44 ( E ) Wall Fan ( Assorted Size ) 45 ( F ) Fresh Air Fan ( Assorted Size ) 46 ( G ) Ceiling Fans Assorted Size 47 ( H ) Assorted Xlpe Aluminum Cable

Key Value

Document Fees
Refer document
EMD
INR 11891.0 /-
Tender Value
INR 5.94 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail